Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | L1 | Accepted-AOC RATES QUOTED ARE REASONABLE | |
| 2 | L2₹44.8 L+₹29,123.84 (0.65%)Rejected-Finance | L2 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 3 | L3₹48.0 L+₹3.4 L (7.72%)Rejected-Finance | L3 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 4 | L4₹48.3 L+₹3.8 L (8.56%)Rejected-Finance | L4 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 | |
| 5 | L5₹48.3 L+₹3.8 L (8.57%)Rejected-Finance | L5 | Rejected-Finance RATES QUOTED ARE HIGHER THAN L1 |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
7 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SEA BIRD KARWAR
GARRISON ENGINEER SEA BIRD KARWAR
REPAIR TO ROOF, CEILING AND OTHER CONNECTING WORKS AT LITTLE BINAGA, KAMAT BAY, BAITHKOL, ANJADEEP, VIVEKANAND NAGAR, KADAMBA VANAM AREA, SANKRUBAGH, ARGA, MO, NSRY AND CORE AREA AT NAVAL BASE KARWAR
2022_MES_529384_3
8909/E8
Open Tender
Civil Works
Item Rate
330 days
KARWAR
AS PER REVISED NIT
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER SEA BIRD KARWAR
₹99,400
Yes
6 Jan 2023
20 Oct 2022
9 Nov 2022
20 Oct 2022
7 Nov 2022
25 Oct 2022
20 Oct 2022 - 22 Oct 2022
60 days
Amount
Dismantling of single layer Mangalore pattern or similar tiles in roofing all as specified and as directed.
M&L for roof tiles, mangalore pattern class 'AA', interlocking at side joints, laid dry complete all as specified and as directed.
All as per Srl item No 02 above but except tiles
M & L for ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
Demolition of cement concrete of any description and any position all as specified and as directed.
M & L for cement concrete type B0, 1:2:4 (12.5 mm graded aggregate) as in roof kerbs or mud stops, or beading for tiles etc chamfered at edges complete all as specified and as directed.
Dismantling/taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distance exceeding 200m & not exceeding 250m all as specified and as directed
M & L for providing 15 mm thick rendering over roof slab in Cement Mortar (1:4) mixed with water proofing compound @ 3% by weight of cement ,finished even and smooth without using extra cement all as specified and as directed.
M&L for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 Kg/lit, @ 0.40 ltrs/Sqm, providing and laying 03 mm thick APP modified water proofing membrane weighting not less than 3.50 Kg/Sqm of approved make including minimum 10 cm side lap and 15 cm end lap, laid and pasted with blue flame torching applications and finally finishing with two coats of solar reflective bituminous aluminium paint @ 0.1.Kg/Sqm all as specified and as directed.
M & L for applying two coats of water proofing coating system by applying shalicryl-215 of STP Ltd/Rain coat 601 of DR fixit / Barrier coat of Araldite over a coat of respective primer including preparation of new/old plaster surface by complete removal of existing treatment including filling of crack with respective crack filler all as per manufacturers instructions all as directed.
Supply only Integral Water proofing compound complete all as specified and as directed.
Dismantling of galvalume aluminium zinc coating GI based plain or corrugated steel sheets of any thickness in roofing all as specified and as directed.
S&F Pre- painted Galvalume Aluminium Zinc coating GI based corrugated steel sheets 0.5 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre- painted Galvalume Aluminium Zinc coating GI based plain steel sheets 0.5 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation) or insulation boards /slab /blankets of any description and thickness including frame/grid of any description all as specified and as directed
M&L for anodised aluminium snap grid (minimum 15 microns anodisation) of size 605 x 605 mm with anodized aluminum angle of size 40mm x 25mm x 2mm thick weighing 0.36 Kg per running meter and anodized aluminum main and cross T of size 36.50 x 23.50 x 1.50 mm thick weighing 0.254 Kg per running meter and 23.50 x 23.50 x 1.50 mm thick weighing 0.202 Kg per running meter respectively for false ceiling all as specified and as directed
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long suitable for size of snap grid 605 x 605 mm complete all as specified and as directed
M&L for PVC insulation panels of 10mm thickness with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of aluminium/ G.I./M.S. as per specification and drawing in ceiling fixed with screws on snap grid all as per manufacturer instructions.
M&L for perforated particle board/tiles for insulation and acoustic purposes of size 60 cm x 60 cm,12 mm thick fixed with staples on snap grid in ceiling all as specified and as directed.
Taking down cement plaster on brick or concrete surfaces of wall/ceiling and likes including racking out joints, hacking for keys scrubbing down with water etc any description including removal of rubbish outside MoD land, complete all as specified and as directed. Note : The rate quoted by the Contractor is deemed to be included necessary scaffolding and form works.
M & L for rendering 15mm thick in CM (1:4) on fair faces of concrete surfaces and finished even and smooth without using extra cement and mixed with water proofing compound @ 3% by weight of cement complete all as specified and as directed
M & L for applying two coats of exterior emulsion weather proof paint including preparation of surfaces on new plastered surfaces of walls all as specified and as directed.
Taking up or down GI tubing and connections 25mm bore including cleaning or removal to store all as specified and directed
Taking up or down GI tubing and connections 32mm bore including cleaning or removal to store all as specified and directed
S&F GI tubing 25 mm bore medium grade, galvanised, ISI marked with all fittings and fixed complete to walls and ceillings or laid in floors all as specified and as directed
S&F GI tubing 32 mm bore medium grade, galvanised, ISI marked with all fittings and fixed complete to walls and ceillings or laid in floors all as specified and as directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc all as specified and as directed.
M&L for PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall 110mm bore all as specified and directed.
S&Fixing 110 mm dia PVC(SWR) bend all as specified and as directed
S&F PVC (SWR) bends of any radius for 100mm bore provided with access door all as specified and as directed
Dismantling of PVC/ RCC water storage tank of capacity exceeding 250 litre but not exceeding 500 litre, including removal of rubbish outside MoD land, complete all as specified and as directed..
Dismantling of PVC/ RCC water storage tank of capacity exceeding 500 litre but not exceeding 1000 litre, including removal of rubbish outside MoD land, all as specified and as directed.
S&F Rotational moulded PVC, double layered, water storage tanks of capacity no exc 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position incl tank cover complete all as specified.
S&F Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, including tank cover, complete all as specified.
S & F in repair 25 mm dia Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 455 gms), screwed & suitable for iron pipe 25 mm bore, complete all as specified.
Draining out water, cleaning and removing accumulated slufge/dirt scales from tank bottom, side and from moiths of circulating pipes of service tank of capacity not exceeding 500 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " CLEANED ON ( DATE)" height of the words 100mm, complete all as specified and as directed.
Draining out water, cleaning and removing accumulated sludge/dirt scales from tank bottom, side and from mouths of circulating pipes of service tank of capacity exceeding 500 ltrs but not exceeding 1000 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " CLEANED ON ( DATE)" height of the words 100mm, complete all as specified and as directed.
S & F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conf to Fe-410-w or E-250 quality. A complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of new steel surfaces of any description exc 10cm in width or girth complete all as specified and directed.
VITTAL P NAYAK
H S krishna Electricals
KVL CONSTRUCTION
VKD CONSTRUCTION
M/S KVG CONSTRUCTIONS
M/S SUMEET MADHAV ASNOTIKAR
Bidder Name
LEKSHMI ENGINEERS
KVL CONSTRUCTION
M/S KVG CONSTRUCTIONS
VKD CONSTRUCTION
H S krishna Electricals
M/S SUMEET MADHAV ASNOTIKAR
VITTAL P NAYAK
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .