Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 4TH FLOOR 4B P 118 PS PHOOL BAGAN CIT ROAD SCHEME VI M KOLKATA KOLKATA WEST BENGAL 700034 | KOLKATA | WEST BENGAL | 700034 | Accepted-Technical Meeting eligibility criteria as per NIT |
| 2 | Accepted-Technical A 6 200 EAST GOKALPURI LONI ROAD EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | Accepted-Technical Meeting eligibility criteria as per NIT |
| 3 | Accepted-Technical 101 BLOCK QP MAURYA ENCLAVE PITAM PURA NORTH WEST DELHI DELHI 110088 | NORTH DELHI | DELHI | 110088 | Accepted-Technical Meeting eligibility criteria as per NIT |
| 4 | Accepted-Technical 502 5TH FLOOR BUILDING NO 72 LAKSHMI BHAVAN NEHRU PLACE NEW DELHI 110019 | SOUTH EAST | DELHI | 110019 | Accepted-Technical Meeting eligibility criteria as per NIT. |
| 5 | Rejected-Technical | Rejected-Technical Not meeting eligibility criteria as per NIT. |
Tender Value
₹64.7 L
EMD Value
₹1.9 L
Closing Date
15 Jun 2026, 6:00 pmClosed
DGM (Engg-E), AAI, Goa Airport
Goa International Airport, Goa-403801
Facade City side Lighting System at Goa Airport
2026_AAI_278350_1
AAI/GOA/DGM(E)NIT-03/2026-27
Open Tender
Electrical Works
Item Rate
120 days
Goa International Airport
As per NIT
17 documents required · 17 mandatory
₹1,180
₹1.9 L
8 Jul 2026
22 May 2026
17 Jun 2026
23 May 2026
15 Jun 2026
23 May 2026
23 May 2026 - 27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB/ RGBWW/ RGBNW/RGBA/RGBW (as per site requirement) Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing, powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 5/10/15/20/25/30/40/45/60 degree. Luminaire should have efficacy of minimum 35 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime of complete luminaire(LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories, Integral male/female water proof connectors IP 68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, RoHS Compliance.
a) 150 Watt | 30 | Each | - | - |
| 2 | Supplying Installation, Testing and Commissioning of Circular/ Rectangular/square LED RGB/ RGBWW/ RGBNW/RGBA/RGBW (as per site requirement) Facade Floodlight/ Projector luminaire for facade lighting with Pressure Die-cast aluminium housing, powder-coated finish, with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, the scale shall be provided for rotation degrees. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection and impact resistance of IK 07. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 5/10/15/20/25/30/40/45/60 degree. Luminaire should have efficacy of minimum 35 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. Lifetime of complete luminaire(LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS: (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories, Integral male/female water proof connectors IP 68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, RoHS Compliance.
b) 100 Watt | 120 | Each | - | - |
| 3 | Supply, installation, testing and commissioning of suitable size outdoor type double door enclosure made out of powder coated CRCA sheet of thickness not less than 1.6 mm, with connectors, Programming and commissioning of items consisting of following items: i) FP MCB 63 Amps as incomer - 01 No ii) FP MCB 32 Amps as outgoing - 04 Nos iii) DMX controller with power supply unit, USB and ethernet/RJ45 connectivity, DMX512 output, with push button panel / mobile application user interface | 2 | Set | - | - |
| 4 | Supply, installation, testing and commissioning of DMX splitter cum booster with power adapter suitable for bi-directional DMX/RDM communication, addressing and DMX control of color changing DMX luminaires etc as required. | 5 | Set | - | - |
| 5 | Supply and making termination of DMX/RDM cable by means of suitable connectors complete as required. | 138 | Set | - | - |
| 6 | Supply and laying of DMX cable for control in existing pipe, cable tray etc as required. | 650 | RM | - | - |
| 7 | Supply of LT power cable 1.1 kV grade Copper conductor XLPE insulated PVC sheathed armoured cable conforming to IS 7098 (Part-I) - 1988 with up to date amendment as required. (a) 4 core × 10 sq.mm | 450 | Mtr | - | - |
| 8 | Supply of LT power cable 1.1 kV grade Copper conductor XLPE/PVC insulated PVC sheathed unarmoured/flexible cable conforming to IS 7098 (Part-I) - 1988 with up to date amendment as required. (a) 3 core × 2.5 sq.mm | 150 | RM | - | - |
| 9 | Laying and fixing of one number PVC/XLPE insulated and PVC sheathed aluminium/copper conductor power cable of 1.1 kV grade, of size not exceeding 35 sq.mm on surface/on cable tray with cable tie as required. | 550 | RM | - | - |
| 10 | aying of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1 kV grade of size not exceeding 35 Sq. mm in the existing RCC/HUME/STONEWARE/METAL/HDPE pipe as required. | 200 | RM | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tenderdocument.pdf
Tender Documents • 12.11 MB
BOQ_325014.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .