Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹39.3 LAccepted-AOC C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹40.0 L+₹45,829 (1.16%)Rejected-Finance | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹40.8 L+₹1.3 L (3.24%)Rejected-Finance RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | L-3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical Documents are not in order |
Tender Value
₹42.6 L
EMD Value
₹85,300
Closing Date
25 Feb 2023, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
PROVN OF TA AND GUN STORES AT CERTAIN UNIT AT HATTIGOR AND SPL REP TO BLDG NO ET-46, ET-75 AND ET-76 BATHROOM AND ET-70, ET-71 AND ET-73 TOILET AT CERTAIN UNIT AT DARRANGA UNDER GE RANGIA
2023_MES_578274_1
8653/E8
Open Tender
Civil Works
Item Rate
180 days
TAMALPUR AND DARRANGA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE Rangia
₹85,300
Yes
9 Mar 2023
31 Jan 2023
27 Feb 2023
31 Jan 2023
25 Feb 2023
8 Feb 2023
31 Jan 2023 - 4 Feb 2023
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for Brick Work with subclass ‘B’ bricks, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L for Brick Work with subclass ‘B’ bricks, Straight or Curved on Plan to any radius in half brick thick walls built in Cement Mortar 1:4, complete all as specified and as directed.
M&L for RCC (nominal mix) type B1 (1:2:4) 20mm graded aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for RCC (nominal mix) type B1 (1:2:4) 20mm graded aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engineer-in-charge.
M&L for RCC (nominal mix) type B1 (1:2:4) 20mm graded aggregate as in chajja, complete all as specified and as directed by Engineer-in-charge.
M&L RCC (nominal mix) type B-1, 1:2:4 (20 mm graded Agg) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; finished in rough surfaces vertical or to batter, complete all as specified and as directed by Engineer-in-charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to chajjas and similar items including edges as in fair finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick rough finished surfaces of concrete flat, complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as per specified and as directed by Engineer-in-charge.
M&L rendering 15 mm thick in cement (1:4) finished even and smooth without using extra cement on brick surface on external surface with WPC @ 3% by weight of cement. (WPC shall be measured and paid seperately).
Supply only integral water proofing compound.
M&L rendering 10mm thick on other than fair faces of brick work or concrete block surface in cement mortar 1:6, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L preparing new plastered surfaces of walls and applying three coats of white lime wash, complete all as specified and as directed by Engineer-in-charge.
M&L preparing plastered surfaces and applying two coats of cement based paint over a coat of primar on external surfaces of walls, complete all as specified and as directed by Engineer-in-charge.
S&F exposed GI powder coated snap grid frame of false ceiling 600 X 600 mm size of wall angle 25 X25 X 0.30mm size cross Tee 22 X 35 X 0.60mm with 2mm dia GI suspender fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm including supply and fixing of 4 mm thick pre painted E- board in false ceiling including fixing arrangement from roof, complete all as per specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation and protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge.
M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge.
M&L for 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing laid in alternate bays incl finishing the surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in footpath/ hard standing/pavings/plinth protections, laid in alternate bays finished even and smooth using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L Machine cut kota stone slab flooring 15-18mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and smooth polishing laid over 15mm thick screed bedding layer in CM 1:6 for laying in floor etc complete all as specified and as directed by the Engr-in-charge
M&L Kota stone slab 15-18mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including 10mm thick screed bed in cement mortar 1:4 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed. all as specified and as directed.
S&F Pressed steel frames (125x60) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, and inside filled with PCC 1:3:6 (12.5mm graded stone aggregate) etc., complete all as specified in SSR Pt-I,
S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
M&L for Preparation of newly untreated wood or wood base surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of Synthetic Enamel paint over a coat of zink chromate primar prime, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new steel surfaces exceeding 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engr-in-Charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars , dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
S&F MS framed work as grills, gratings etc.. with ends of bars shouldered or riveted, framed guard bars and similar work conforming to Fe -290 Gde E-195, complete all as per specified and as directed by Engineer-in-charge.
S&F steel ventilators with top hung shutter including hinges, steel peg stay complete, complete all as per specified and as directed by Engineer-in-charge.
S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane, complete all as per specified and as directed by Engineer-in-charge.
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F 125 mm long Stainless steel butt hinges medium weight clod rolled and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as per specified and as directed by Engineer-in-charge.
S&F, double legged door stopper of size 150mm of aluminium alloy with rubber complete all as specified and as directed.
S&F Prepainted galvalume aluminium zince coating GI based orrugated/ Semi-corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as per specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zince coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as per specified and as directed by Engineer-in-charge.
S&F MS steel work in tubular trusses including special shaped washers etc., complete using but ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 with one shop coat of zinc chromate primer paint, complete all as per specified and as directed by Engineer-in-charge.
S&F Mild steel , flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, wind ties, clamps and similar small articles etc., complete all as per specified and as directed by Engineer-in-charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.), any gauge, thickness, including nainital or similar pattern roof coverings.
Demolition of brickwork / block masonry built in cement mortar including all quoins, arches, pillars etc., complete all as per specified and as directed by Engineer-in-charge.
Taking down cement plaster of any description incl raking out joints, haking for key scrubbing down with water etc, complete all as per specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L for demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 6-8 mm dia. cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for Dismantling frammed Truss span n.exc. 10m (wooden), complete all as per specified and as directed by Engineer-in-charge.
S&F Mild steel work in hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-charge.
M&L Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile 400x400mm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
S&F Coloured Glazed ceramic tiles 350 x 250 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 10 mm thick screed bed or bedding layers in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
S&F in-repair 15 mm bore Galvanized Steel tubes, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair 20 mm bore Galvanized Steel tubes, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair 25 mm bore Galvanized Steel tubes, medium grade water supply pipes etc., fixed to walls and ceilings or laid in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair 15 mm bore Chromium plated bib taps, fancy type, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F in repair 15mm stop/angle cock cast copper alloy, fancy type with chromium plated for iron pipe or for unions complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair 2 in 1 Bib Taps 15 mm Bore, Cast Copper Alloy,with crutch or butterfly screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed, complete all as specified and as directed.
S&F in repairs Vitreous China wash down water closet pan 580 x 440 mm (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete as specified and as directed by Engineer-in-Charge.
S&F in-repair Vitreous China squatting pan "Orissa" patern size 580x440mm white with integral foot rest including connection to trap and to flushing pipe, anti-syphonage pipe, etc including 'P' or 'S' trap complete all as per specified and as directed by Engineer-in-charge.
S&F PVC valveless, syphonic action type, flushing cistern 10 ltrs capacity, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F 15mm dia PVC connection pipe with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-charge.
S&F in-repair 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints and necessary fittings laid in trenches or in floors complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints and necessary fittings laid in trenches or in floors complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of brass chromium plated Tubular towel rail, 600mm long, 20mm dia, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of CP Soap dish, any type of size 160 x 160x 90mm fixed to plugs with chromium plated brass screws complete all as specified and as directed by Engineer-in-charge.
S&F in-repair 150 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints and necessary fittings laid in trenches or in floors complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore, complete all as per specified and as directed by Engineer-in-charge.
Taking down chowkhats with shutters but not exceeding 1.5 Sqm each (without taking of shutters from the frame), complete all as per specified and as directed by Engineer-in-charge.
S&F factory made PVC door frame with shutter made of 50x47 of 5mm thk pvc sheet reinforced with MS square tube (frame) and of 30mm thk soild panel shutter consisting of frame made out of MS tubes at top & bottom rails, covered with heat moulded 'C' channel and jointed togehter with solvent cement, supplying & fixing in the frame at site as per specification complete all as specified and directed.
S&F 100 mm long extruded Aluminium alloy anodised Butt hinges with galvanized mild steel hinges, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F 200 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified.
S & F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms), including fixing to steel pipe or union, complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light or fan point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 81 above but for 3 pin socket outlet point controlled by one 5/6 Amp, one way switch on the same board.
All as per serial item No. 81 above but for 3 pin socket outlet point controlled by one 5/6 Amp, one way switch on the independent board.
All as per serial item no. 81 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket on independent boards.
Supply and fix switch piano flush type, 5/6 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fix socket outlet 3 pin 5/6 Amp flush type complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 15/16 Amp 3 pin flush type, complete all as specified and as directed by Engineer-in-charge.
S&F of box type surface and wall mounted LED 22 Watts, (Decorative) Light Fitting (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 240 Volts, complete with all accessories internally pre-wired and necessary mounting arrangements, with and including of new 2 Core multi-stranded Copper Conductor of size 0.5 Sqmm from Ceiling Rose to Fitting including LED Tube 4'x20 Watts, complete all as specified and as directed
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 20 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, complete all as specified and as directed.
S&F of security light bracket made out of 25 mm dia GI pipe 1.00 m long, light grade, bend to required shape with two pair of MS flat iron clamp of 50mm x 6mm with siutable nut-bolt and washer, complete all as per specified and as directed by Engineer-in-charge.
S&F of Sheet Metal Enclosure MCB DB SPN, 2 way 240 volt, with 200 Amps rated Bus-bar, single door type MCB DB suitable for mounting incoming and outgoing MCBs double pole/ single pole complete all as specified and as directed.
S&F of MCB Single Pole & Neutral (SPN), 'C' Curve, 20-40 Amps, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed.
Supply and fixing of 1100 volts grade heavy duty cable, PVC insulated aluminium stranded condcutor with inner sheathed of PVC tape and over all PVC sheathed for service connection suspended by insulating hangers not more than 01 mtr apart including 4mm dia suspension wire and 4Sqmm twin core cable flat or circular complete including taking down old service connection all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 5/6 Amp 3 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED tube light fittings1 x 20 Watt,220 V, AC decorative box type with driver holder including LED tube rodconnecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with 200 Amps rated Bus-bar, double door type MCB DB suitable for mounting incoming and outgoing MCBs double pole/ single pole complete all as specified and as directed.
S&F of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed.
Supply and fixing ceiling fan having sweep size of 1200 mm, 240 volt, energy efficient, 3 blades, down rods, electronic regulator with inetrnal pre-wired including accessories such as hook, nuts, bolts, etc. min air delivery 210 CFM with service value 6.00 BEE. five star rated with brushless direct current motor (BLDC), complete all as per specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
Supply, fixing, laying & testing of 10 Sqmm 2 core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade cable, complete all as specified and as directed by Engineer-in-charge.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F GI tube 40 mm bore (dia) light grade fixed to wall, ceiling or laid in floor/ trenches for cable protection, complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S SWMKHWR ENTERPRISE
M/S NARAYAN ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .