Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance MIRZAPUR MUMTAZ NAGAR AYODHYA AYODHYA UTTAR PRADESH 224001 | AYODHYA | UTTAR PRADESH | 224001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical All Pre Qualifying conditions Not Fulfilled |
| 5 | Rejected-Technical | Rejected-Technical All Pre Qualifying Condition Not Fulfilled |
Tender Value
Refer Docs
EMD Value
₹60,200
Closing Date
6 Jun 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S.E, EUCC-V, LESA, Cis-gomti,Lucknow
Room No.61, LESA Bhawan Near Residency Park, Kaiserbagh, Lucknow
As per tender specification
2024_MVVNL_919824_1
56/EUCC-V/LESA/2023-24
Open Tender
Electrical Works
Fixed-rate
60 days
33/11 kv S/S Jaitikhera
As per tender specification
2 documents required · 2 mandatory
₹3,540
A/c. No. 10101985364, IFSC CODE No.SBIN0003347,SBI
₹60,200
18 Jul 2024
30 Mar 2024
6 Jun 2024
30 Mar 2024
6 Jun 2024
30 Mar 2024
Amount
Safe Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dump store and JE dump store to work site within municipal areas.
33 KV Line Isolator
33 KV Bus Isolator 800 Amp
33 KV Lightening Arrester 400 Amp.
33 KV VCB 800 Amp, 750 MVA
33 KV Current Transformer 400/200/1A
33 KV Current Transformer 200/100/1A
33 KV PT 33KV /110V
ACSR Panther Conductor for Bus Bar
Disc Insulator B&S type 70 KN
Disc fitting 70 KN (B&S type)
33 KV Control Pannel double Circuit for Transformer
33 KV Control Pannel single Circuit feeder
Cost of 11/0.4 Transformer 63 KVA
11 KV Incoming VCB 600/300/5A, 350 MVA
11 KV Out going VCB 200/100/5A, 350 MVA
11 KV VCB B/C, 350 MVA
11 KV 3x300 mm2 XLPE Cable
11 KV 3x185 mm2 XLPE Cable
11 KV 3x70mm2 XLPE Cable
11 KV 3x300mm2 Outdoor Termination Kit
11 KV 3x300mm2 Indoor Termination Kit
11 KV 3x185mm2 Outdoor Termination Kit
11 KV 3x185mm2 Indoor Termination Kit
11 KV 3x185mm2 Straight through
11 KV 3x70mm2 Out Door Termination Kit
11 KV 3x70mm2 In Door Termination Kit
LT Cable 3.5x70/35 mm2
Battery Charger Complete 24 Volt
Battery Set 24 Volt
ST pole 11 mtr long
ST pole 9 mtr long
M.S.channel 100x50 sq mm
M.S.Angle 65x65x6 sq mm
11 kv pin insulator
11 kv pin with nut
M S Earthing Rod 20x2500 mm
1x240 LT XLPE Cable
Rail 105 lb 9 mtr long
M.S.Channel 125x65x6 mm
MS Angle 75x75x6, 2.6M 2 Nos Total [email protected] Kg./M with wastage
MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr.
Top channel 100x50mm
MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge [email protected] Kg./M
MS Round of 32mm dia for making MS earth electrode 32x3000mm. [email protected] Kg./M
Earthing of substation Switchyard.
Checking of soil resistivity of S/S land and if required take necessary measure to make soil resistivity as per norms.
Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM)
Cutting ,fabrication and driving of earth electrode of size 32x3000 mm
Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor )
Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms.
Construction of Power T/F plinth suitable for 33/11KV 5 MVA power T/F of size 4.46x3.46x1.3 m having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6:12 (cement, fine sand & brick ballast) as well as 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 nos rail pieces 4.46 mtr long as per drawing/practice the plinth shall be finished in all respect. (All materials Provided by contractor)
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4Nos foundation volts for erection of 33KV VCB.(All materials Provided by contractor)
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting of structure complete.(only M.S channel and angle provided by the deptt)
Lightning Arrestor/ CT structure/ PT structure : - Fabrication of lightning arrestor/CT structure/ PT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect and painting of structure complete.
33kv busbar : - making of busbar with rail pole. by using ACSR panther conductor and disc fitting as per RESSPO drawing with the help of M.S channel. Also including of grouting of rail pole, plinthing and painting of all structure . earting of rail pole. (all material provide by contractor except centralised above matarials)
Fabrication & erection of 11 KV cable Exposure type double pole with the provission of bus bar with fixing of necessary clamps and other accessories like danger board, number plate, barbed wire, 9 no. pin insulators with pins, 2 No. MS-CHANNEL & 2no. MS angle for supporting the hoisting on Pole.Its jumpering by single core PVC aluminium cable with proper size of lug. Painting of double pole with one coat of red oxide & two coats of enamel paints (ISI mark). Its grouting in ratio 1:4:8 & plinthing 300 mm above ground level WITH EARTING OF POLES. (All material to be arranged by contractor except steel,pole,PVC aluminium cable,earthing rod,Pin & Pin insulator).as per RESPO norms. .
Fabrication & erection of S/S type double pole on 11 mtr. long ST-Pole with fixing of top/MS-Channel 100x50 mm, MS-angle 65x65x6 mm, Pin insulator with pin with arrangement of Bus bar and fixing of D.O. fuse set as per Respo norms. Its grouting in ratio 1:4:8 & plinthing 300 mm above ground level With earthing of poles (All materials will be provided by contractor except ST-pole, MS- channel, MS- Angle, Pin insulator and Pin and earthing rod).
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
Fabrication & Erection of Neutral Stand structure with foundation with painting
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
33 KV VCB
CT 200/100/1-A & CT 400/200/1A
33 KV lightning Arrestors
Bus/Line Isolator
33 KV PT 33KV /110V
Connecting 5 MVA Power Transformer to 33 KV & 11 KV line & jumpering by 1x630 Sqmm. cable including with fixing of connector & Al. lugs (Required connectors, PG clamps & Al. lugs will be provided by contractor).
Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut &Bolts from 33KV bus bar & 33KV cable to T/F (with copper L piece) complete work.(2 no. T/F bay)
Laying of double circuit 11KV 3x300 sq mm XLPE cable in construted trench with proper ferrurling. Cable trench should filled by fine sand.
Laying of D/C 11 KV, 3x185 sq mm XLPE cable in normal soil by digging of trench of suitable size & it's boxing with brick & sand and properly levelling & ramming after laying of cable etc. (All required materials will be provided by contractor except 11 KV cable)
Laying of D/C LT 3.5x70/35 sq mm XLPE cable in normal soil by digging of trench of suitable size & it's boxing with brick & sand and properly levelling & ramming after laying of cable etc. (All required materials will be provided by contractor except LT cable)
Laying of D/C 11 KV, 3x70 sq mm XLPE cable in normal soil by digging of trench of suitable size & it's boxing with brick & sand and properly levelling & ramming after laying of cable etc. (All required materials will be provided by contractor except 11 KV cable)
Hoisting, jumpering, clamping of 11KV 3x300/3X185/3X70 sq mm XLPE cable on cable stand/panel with proper taping with the help of empire tape. PVC tape and connectors.
Hoisting, jumpering, clamping of 11KV 3x300/3X185/3X70 sq mm XLPE cable on DP with proper taping with the help of empire tape. PVC tape and connectors.
Construction and fixing of trench cover0.5 M wide 5 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench 800 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system.
2x2.5 sq mm
4x2.5 sq mm
6x2.5 sq mm
Earthing of All Substation equipment and 5 MVA T/F body and neutral by way of boring and lowering of G.I pipe 1.5" dia up to water level and minimum 20 M deep from the ground level connection in between GI pipe and T/F with GI strip of size 50x6 mm.
Supply and installation of fire bucket set (one no stand and four no bucket filled with sand )at suitable place as per RESPO Norms
Supply and installation of fire extinguisher 5kg dry chemical powder at suitable place as per RESPO Norms
Supply and installation of fire extinguisher Co2 type 4.5 Kg at suitable place as per RESPO Norms
supply of rubber mat (2x1.5 mtr)
supply of furniture
office table
chair(steel make/wooden)
3 seater airport model chair
sitting bench
Complete work of fixing of inertlocking tils in swithchyard area. (All the materials shall be provided by contracter)
Complete work of fixing of gravels in swithchyard area. (All the materials shall be provided by contracter)
complete switchyard fencing with toe wall
Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement, erection, grouting, commissioning & complete testing of the same as per RESPO Norms
33kv Feeder control panel/double circuit T/F control pannel
11KV I/C pannel
11 KV O/G Pannel
11KV B/C pannel
Digging of pit of size 3x2x1 mtr. for making straight through joint 11 KV work involved filling of soil levelling and ramming of the same.
High Pressure Testing
Safe Dragging, loading, carriage and unloading of balanced materials with proper stacking from site to JE dump store/Lesa store after completion of work.
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
Hindustan Electric Work
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .