Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 CrAccepted-AOC MATERE HOUSE SEC NO 14 PRADHIKARAN PUNE MAHARASHTRA INDIA 412105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹7.1 Cr+₹100.0 L (16.5%)Rejected-Finance PLOT NO 13 3RD FLOOR BANSAL PLAZA SECTOR 6 COMMERCIAL COMPLEX DWARKA NEW DELHI 110075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹8.2 Cr+₹2.1 Cr (35.2%)Rejected-Finance 3RD FLOOR B K ENCLAVE MOTILAL NEHRU ROAD PAN BAZAR GUWAHATI KAMRUP METROPOLITAN KAMRUP METRO ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | L4₹8.4 Cr+₹2.3 Cr (38.3%)Rejected-Finance 20 SC BOSE COLONY GALI NO 02 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Other than L1 bidder | |
| 5 | Rejected-Technical 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | - | Rejected-Technical No remarks in WLR of CESWC QE Dec 2024 |
| Sl No | Description | Qty | Unit | M K ENGINEERS CO. L4 | V M MATERE INFRASTRUCTURES INDIA PVT LTD L1 | M/S RADIUS SYNERGIES INTERNATIONAL PVT LTD L2 | Purbanchal Synergies Pvt. Ltd L3 |
|---|---|---|---|---|---|---|---|
| .10SCHEDULE "A" PART I (Smart energy Meter work) | |||||||
| 1.00 | Taking down existing energy meters carefully from existing meter box after disconnecting the power supply by deploying of skilled manpower, carefully opening connection from terminals and depositing in E/M stores for safe custody. Also ensure proper database w.r.t. locations of meters alongwith it's final readings before effecting disconnection of the meters & being removed from wall and providing the same to MES for final settlement for all the meters complete all as directed. | 2,106 | Each | 400 ₹8,42,400 | 200 ₹4,21,200 | 368.75 ₹7,76,587.5 | 100 ₹2,10,600 Lowest |
| 2.00 | Taking down existing ammeter, voltmeter, multifuction meter including CT/PT if any from existing electrical LT Panel after disconnecting the power supply carefully from existing LT Panel by deploying of skilled manpower complete all as directed by the Engr in charge. | 620 | Each | 500 ₹3,10,000 | 200 ₹1,24,000 | 737.5 ₹4,57,250 | 100 ₹62,000 Lowest |
| 3.00 | Supply , installation, testing and comissioning of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current,single phase, 2 wires Smart Energy Meter of rating 240 Volt, 5/10-60 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I . The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter complete all as specified and directed.
Note:
Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. | 1,436 | Each | 8,500 ₹1,22,06,000 | 7,000 ₹1,00,52,000 | 10,112.5 ₹1,45,21,550 | 4,850 ₹69,64,600 Lowest |
| 4.00 | Supply , installation, testing and comissioning of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter complete all as specified and directed.
Note:
Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. | 456 | Each | 10,500 ₹47,88,000 | 10,000 ₹45,60,000 | 12,472.5 ₹56,87,460 | 7,100 ₹32,37,600 Lowest |
| 5.00 | Supply , installation, testing and comission of Smart energy Meter (IS-16444), AC whole current,three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S ,415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner . The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter should be based on RF Mesh communication technology or Cellular communication technology.The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. Including the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete all as directed.
Note:
Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. | 490 | Each | 20,000 ₹98,00,000 Lowest | 20,000 ₹98,00,000 Lowest | 21,175 ₹1,03,75,750 | 24,500 ₹1,20,05,000 |
| 6.00 | Supply , Installation and fixing Smart energy prepaid single phase meter with following specification : - AC Single phase, two wire ,tamper proof ,static meter of class 1.0, 240 V, 50 Hz , 10- 60 A conforming to IS - 16444: 2015 (Reaffirmed 2020) and relevant IEC standards with inbuilt 865-867MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility , anti- tamper features, microprocessor and LED/LCD based circuitry, enclosed in polycarbonate box. The meter should support the following data :
(i) 30 min instantaneous data for voltage,current,Power factor ,power,cumlative energy and frequency ,30 load survey load data for energy ,monthly billing survey for cumulative energy and max demand.
(ii) Meter connect / disconnect functionality operable from prepaid billing software.
(iii) The meter should support open communication protocol DLMS with the software. | 304 | Each | 8,500 ₹25,84,000 | 10,000 ₹30,40,000 | 10,112.5 ₹30,74,200 | 4,850 ₹14,74,400 Lowest |
| 7.00 | Supply, Installation and fixing Smart energy prepaid 3 phase meter with following specification : - AC three phase, four wire ,tamper proof ,static meter of class 1.0, 415 V, 50 Hz , 10- 60 A conforming to IS - 16444: 2015 (Reaffirmed 2020) and relevant IEC standards with inbuilt 865-867MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility , anti- tamper features, microprocessor and LED/LCD based circuitry, enclosed in polycarbonate box. The meter should support the following data :
(i) 30 min instantaneous data for voltage,current,power factor ,power,cumlative energy and frequency ,30 load survey load data for energy ,monthly billing survey for cumulative energy and max demand.
(ii) Meter connect / disconnect functionality operable from prepaid billing software. (iii) The meter should support open communication protocol DLMS with the software.
Note For item No.3 to 7 : -
(i) Smart energy prepaid meter shall meet minimum specification criteria as per particular specification for Scope of work and Tech specification.
(ii) Bidder shall provide replacement warranty of 5 years from the date of activation of smart energy meter for any type of Defect/ fault/ Error in reading/ Non functioning of smart feature.
(iii) The smart energy meter shall not have built in soft keys for recharging through token system. | 40 | Each | 10,500 ₹4,20,000 | 15,000 ₹6,00,000 | 12,472.5 ₹4,98,900 | 7,100 ₹2,84,000 Lowest |
| 8.00 | Data Concentrator Unit (DCU) for RF meters - Outdoor type DCU based Monitoring / controlling panel of suitable size made out of 1.6 mm thick CRCA sheet. The DCU panel shall be able to monitor and control upto 50 meters over RF mesh and shall consist of the following equipments.
(i) DCU shall have (commercial grade) minimum 1Ghz processor with 256 MB RAM, with suitable, 02 Nos. RS485 communication ports, 1 No. Ethernet port. DLMS, Modbus, IEC104 and DNP3 compatibility, Aux. supply 230V DC, Program memory backup facility for 180 days, Real time clock, Operating temperature range 0 to 70·degree celcious. with inbuilt GPRS modem (4G enabled with at least 150MBPS speed) with suitable external antenna, capable of sending data remotely and SMS as well. The DCU shall be NABL certified as per IEC 61010-1 (clause 6.8}-Dielectric and IEC 60255-27 (clause 10.5.3) -Impulse testing.
The DCU shall have a remote webpage; the remote webpage shall have capability to integrate 50 such DCUs. The webpage standard design shall be capable of sending and receiving data for meter monitoring and control using a web link over Internet connection.
(ii) Surge Protection device
(iii) Suitable MCB
(iv) 0.5 Sqmm multistranded internal wiring with ferruling suitable lugs.
The modem shall be inbuild type and have following features:
(i) GPRS Multi-slot GPRS class 10/8; GPRS station class B
(ii) Power Class 4 (2 W@ 850/900 MHz) and Power Class 1 (1 W@ 1800/1900 MHz)
(iii) QMI and MBIM enabled
(iv) Auto restore -time reset | 15 | Each | 82,000 ₹12,30,000 Lowest | 1,00,000 ₹15,00,000 | 1,10,625 ₹16,59,375 | 1,25,000 ₹18,75,000 |
| 9.00 | Supply and Installation of Single phase meter as repeaters ( will be required wherever RF signal strength is low). | 10 | Each | 18,000 ₹1,80,000 | 10,000 ₹1,00,000 | 10,325 ₹1,03,250 | 4,850 ₹48,500 Lowest |
Tender Value
₹7.7 Cr
EMD Value
₹7.1 L
Closing Date
27 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, SHILLONG MEGHALAYA
PROVN AND UPGRADATION OF SMART PREPAID METERS IN VARIOUS MIL STN UNDER CHIEF ENGINEER SHILLONG ZONE
2024_MES_684650_2
89804/SHL/E8
Open Tender
Civil Works
Item Rate
3285 days
dinjan
All as per tender document
2 documents required · 2 mandatory
₹3,000
GE DINJAN
₹7.1 L
Yes
4 Aug 2025
6 May 2025
29 May 2025
7 May 2025
27 May 2025
13 May 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.1 | SCHEDULE "A" PART I (Smart energy Meter work) | - | - | - | - |
| 1 | Taking down existing energy meters carefully from existing meter box after disconnecting the power supply by deploying of skilled manpower, carefully opening connection from terminals and depositing in E/M stores for safe custody. Also ensure proper database w.r.t. locations of meters alongwith it's final readings before effecting disconnection of the meters & being removed from wall and providing the same to MES for final settlement for all the meters complete all as directed. | 2,106 | Each | 100 | ₹2,10,600 |
| 2 | Taking down existing ammeter, voltmeter, multifuction meter including CT/PT if any from existing electrical LT Panel after disconnecting the power supply carefully from existing LT Panel by deploying of skilled manpower complete all as directed by the Engr in charge. | 620 | Each | - | - |
| 3 | Supply , installation, testing and comissioning of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current,single phase, 2 wires Smart Energy Meter of rating 240 Volt, 5/10-60 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I . The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter complete all as specified and directed.
Note:
Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. | 1,436 | Each | - | - |
| 4 | Supply , installation, testing and comissioning of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter complete all as specified and directed.
Note:
Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. | 456 | Each | - | - |
| 5 | Supply , installation, testing and comission of Smart energy Meter (IS-16444), AC whole current,three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S ,415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner . The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter should be based on RF Mesh communication technology or Cellular communication technology.The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. Including the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete all as directed.
Note:
Bidder shall procure meter from three different manufacturer having minimum quantity of any one make shall not be less than 30% of total meter. | 490 | Each | - | - |
| 6 | Supply , Installation and fixing Smart energy prepaid single phase meter with following specification : - AC Single phase, two wire ,tamper proof ,static meter of class 1.0, 240 V, 50 Hz , 10- 60 A conforming to IS - 16444: 2015 (Reaffirmed 2020) and relevant IEC standards with inbuilt 865-867MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility , anti- tamper features, microprocessor and LED/LCD based circuitry, enclosed in polycarbonate box. The meter should support the following data :
(i) 30 min instantaneous data for voltage,current,Power factor ,power,cumlative energy and frequency ,30 load survey load data for energy ,monthly billing survey for cumulative energy and max demand.
(ii) Meter connect / disconnect functionality operable from prepaid billing software.
(iii) The meter should support open communication protocol DLMS with the software. | 304 | Each | - | - |
| 7 | Supply, Installation and fixing Smart energy prepaid 3 phase meter with following specification : - AC three phase, four wire ,tamper proof ,static meter of class 1.0, 415 V, 50 Hz , 10- 60 A conforming to IS - 16444: 2015 (Reaffirmed 2020) and relevant IEC standards with inbuilt 865-867MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility , anti- tamper features, microprocessor and LED/LCD based circuitry, enclosed in polycarbonate box. The meter should support the following data :
(i) 30 min instantaneous data for voltage,current,power factor ,power,cumlative energy and frequency ,30 load survey load data for energy ,monthly billing survey for cumulative energy and max demand.
(ii) Meter connect / disconnect functionality operable from prepaid billing software. (iii) The meter should support open communication protocol DLMS with the software.
Note For item No.3 to 7 : -
(i) Smart energy prepaid meter shall meet minimum specification criteria as per particular specification for Scope of work and Tech specification.
(ii) Bidder shall provide replacement warranty of 5 years from the date of activation of smart energy meter for any type of Defect/ fault/ Error in reading/ Non functioning of smart feature.
(iii) The smart energy meter shall not have built in soft keys for recharging through token system. | 40 | Each | - | - |
| 8 | Data Concentrator Unit (DCU) for RF meters - Outdoor type DCU based Monitoring / controlling panel of suitable size made out of 1.6 mm thick CRCA sheet. The DCU panel shall be able to monitor and control upto 50 meters over RF mesh and shall consist of the following equipments.
(i) DCU shall have (commercial grade) minimum 1Ghz processor with 256 MB RAM, with suitable, 02 Nos. RS485 communication ports, 1 No. Ethernet port. DLMS, Modbus, IEC104 and DNP3 compatibility, Aux. supply 230V DC, Program memory backup facility for 180 days, Real time clock, Operating temperature range 0 to 70·degree celcious. with inbuilt GPRS modem (4G enabled with at least 150MBPS speed) with suitable external antenna, capable of sending data remotely and SMS as well. The DCU shall be NABL certified as per IEC 61010-1 (clause 6.8}-Dielectric and IEC 60255-27 (clause 10.5.3) -Impulse testing.
The DCU shall have a remote webpage; the remote webpage shall have capability to integrate 50 such DCUs. The webpage standard design shall be capable of sending and receiving data for meter monitoring and control using a web link over Internet connection.
(ii) Surge Protection device
(iii) Suitable MCB
(iv) 0.5 Sqmm multistranded internal wiring with ferruling suitable lugs.
The modem shall be inbuild type and have following features:
(i) GPRS Multi-slot GPRS class 10/8; GPRS station class B
(ii) Power Class 4 (2 W@ 850/900 MHz) and Power Class 1 (1 W@ 1800/1900 MHz)
(iii) QMI and MBIM enabled
(iv) Auto restore -time reset | 15 | Each | - | - |
| 9 | Supply and Installation of Single phase meter as repeaters ( will be required wherever RF signal strength is low). | 10 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 0.27 MB
Tenderdocument.pdf
Tender Documents • 3.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .