Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Being first lowest | |
| 2 | L2₹34.6 L+₹30,993 (0.90%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹39.9 L+₹5.6 L (16.2%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹40.0 L+₹5.7 L (16.5%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹42.3 L+₹8.0 L (23.3%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
₹46 L
EMD Value
₹96,000
Closing Date
21 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
SPL REPAIR TO BLDG NO P-48 AND P-52 AT LGJ MIL STN
2024_MES_643577_1
8934-66/GE/2023-24
Open Tender
Civil Works - Canal
Item Rate
180 days
GE Lalgarh Jattan
As per tender document
8 documents required · 8 mandatory
₹500
Yes
GE Lalgarh Jattan
₹96,000
Yes
16 May 2024
22 Feb 2024
23 Mar 2024
22 Feb 2024
21 Mar 2024
7 Mar 2024
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position complete all as directed by Engineer-in-Charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:6) on any face of walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified & directed by Engr-in-charge.
Material and labour for preparation of new plastered surface of walls/pillars/cornices by sand papering or by any other mean and after preparing the surfaces applying two coats of oil bound distemper over and including 3mm thick wall care putty as approved tint/colour over a one coat of priming paint/wall care putty complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment and applying two coats of oil bound distemper over and including 3mm thick wall care putty after preparation of plastered or pointed surface of walls/pillars/cornices by sand papering or by any other means as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for preparation of old plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying two coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surface of walls/pillars /cornices by sand papering or by any other mean and after preparing the surfaces applying two coats of cement base paint as approved tint/colour over a one coat of priming paint complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment from old plastered or unplastered surfaces and applying two coats of cement base paint after preparation of plastered or pointed surface of walls/pillars/cornices by sand papering or by any other means as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Providing and Applying rising damp proof coating system with single component ready to use damp proof coating Roff Hydamp 1. Preparation :- Throughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc all large voids and hallow portions must be removed and re-plastered non moving cracks having width upto 5mm must be filled with polymer based crack filler. 2. Application :- Apply the first coat of Dr. fixit dampguard classic with a paint brush directly on the prepared surfaces by mixing (1 part base : 1 part hardner : 1 part of water), allow to dry for a minimum 2-3 hrs. apply one part of Dampguard mixed chemical and 2 parts of OPC white cement / Birla putty and make the putty, apply putty on the entire surface area, allow to dry for at least 3-4 hrs, apply the final coat of air cure 48 hrs proceeds for paints.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
Material and labour for joint free Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement over and including 15mm thick screed base in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles (jointless) 7 to 8 mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles (jointless) 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, laid in floor. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick rendering in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L joint free glazed ceramic coloured tiles (350 x 250)/(450 x 350) mm x 7mm thick as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
Material and labour 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding the edges half round on exposed side over and including 20mm thick screed base in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge, as in steps, cooking platform, and other similar situations complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25 mm thick and size not less than 55cm x 55cm over and including 15 mm thick cement screed base in CM (1: 6 ) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed.
M & L for machine cut kota stone slab 20-25 mm thick on vertical surfaces laid over and including 10 mm thick backing coat in cement morter 1:4 laid & and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified & directed.
Formwork to sides and soffits of chajjas, troughs and similar items (horizontal or sloping) rough finished complete all as specified and as directed by Engineer-in- charge.
Material and labour for reinforced cement concrete nominal mix type B0, 1:2:4 using 12.5 mm graded stone aggregate as in chhajjas and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
M&L for 75 mm thick PCC type C-2,1:3:6 using 20 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
M&L for continous brick edging; with fly ash bricks old size bricks, with width equal to the width of the brick; liad dry on end vertically complete all as specified and directed by Engr-in-Charge.
Material and labour for water proofing treatment to RCC sunken slab and adjoining verticle surface (n.exc 45cm depth of sunken) specified as under and as directed by Engr-in-charge:- (i) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (ii) applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as directed by the Engineer-in-Charge. (iii) Material and labour for creating fillet caving 50x50mm with polymer modified mortar on the junction of slab and wall as per manufacture instructions, (iv) Applying 1st coat of two components modified polymer coating on horizontal and verticle surfaces. (v) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (vi) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. (vi) Joining the sanitary pipe with the water proofing tape having bridging ability of more then 1.5 mm. (vii) filling the gap between the wall opening and sanitary pipe with non shrink cementatious grout. NOTE:- Complete treatment to be carried out by authorised applicatior of waterproofing manufacture. Make : Dr Fixit/Fosroc/BASF/STP
Material and labour for PCC(1:5:10), type E-2 using 40 mm graded stone aggregate as filling in sunken floor/bottom and sides of wall complete all as specified and as directed by Engineer-in-charge.
Dismantling of brick tiles in floor laid dry and pointed in cement mortar complete all as specified and directed by Engineer-in-Charge.
Demolition of mud in roof, any thickness, including plaster and leeping complete all as specified and directed by Engineer-in-Charge.
M&L for 40 mm thick cement concrete type B0, 1:2:4 (12.5 mm graded stone aggregate) as in roof padding and laid in slope 1:40 complete all as specified.
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane, reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Make : STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal Bitumen.Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
M & L for cement concrete tiles 25cm x 25cm x 22mm thick, m a c h i n e pressed with grey cement and pigment over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment and no pigment in floors/roof, and cut and polished complete all as specified and directed.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in coping, roof kerb, bed block, blocks for hold fast,fixing of pipe & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for repair to damage RCC coloumns/Beam/Slab/Chajja by using micro mortar and concrete in Following Stages :- (a) Removing the mortar and loose concrete from RCC elements. (b) Cleaning the rusted reinforcements and applying rust removal. (c) Inserting the addl reinforcements in case the coves sectional area reduction is more than 20 percent by welding the reinforcement with existing bars and supporting adequate on walls if reqiurd with grout. (d) Providing micro morter and concrete over bond coat to cover the reinforcements and slet surface. (e) Providing adequate formwork and scaffolding if required. (f) Curing the surface. Note :- (i) Rust removal, bonding agent, grout, micro mortar and concrete and related chemicals shall be of Dr Fixit/BASF and STP (ii) Work is to be got executed from authorised applicator of the company. (iii) Steel reinforment shall be measured and paid separately
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each and removing from site complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each and removing from site complete all as specified and as directed by Engineer-in- charge.
Taking down shutters of any description area exceeding 1.0 sqm but not exceeding 2.0 sqm each leaf and refixing in the same opening after necessary easing, adjustments etc. complete all as specified and as directed by Engineer-in- charge.
S & F fiber glass reinforced plastic (FRP) door frame (ISI marked) of cross-section 90mm x 45mm (minimum) having single rebate to receive shutter of 30mm thickness. The laminate door frame moulded with fire retardant grade unsaturate polyster resin and chopped strand mat (CSM), door frame laminate shall be 2mm thick, filled with core material and shall be filled with suitable wooden block for fixing hinges and other Hardware accessories, the frame shall be covered with fiber glass from all sides. MS stay shall be provided at the bottom to stand by the frame complete all as specified and directed by Engineer-in-Charge.
S & F 30mm thick glass fiber reinforced plastic (FRP) panelled door shutter (ISI marked) of required colour made with fire retardant grade unsaturated polyester resin moulded to 3mm thick FRP laminate for forming hollow rails and styles, filled with core material, wooden frame alround and suitable wooden block for fixing of hard ware accessories made out of seasoned wood inside as required, cast monolithically complete all as specified and directed by Engineer-in-Charge.
M & L for rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting of other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel handing door fitttings (exclusive or steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing confirming to Fe-410 W (Gde-E-250) complete all as specified and directed by Engr-in-charge.
M&L for 35 mm thick factory made, 2nd class hard wood , plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood (Hollock / Bonsom) open rebated and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8.20 (a) and fitted to chowkhats complete all as specified & directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply and fixing 100mm long butt hinges stainless steel medium weight complete all as specified & directed by Engineer-in-charge.
S&F for 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and directed by Engineer-in-Charge.
S&F for 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed by Engineer-in-Charge.
S&F for 100 mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engineer-in-Charge.
S&F for 150 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing mild steel sliding door bolts 300mm long plate type, stove enameled black, with bright bolt not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
S & F 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed all as specified & directed.
Supply & fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed with stainless steel wire staples all as specified & directed by Engineer-in- charge
Supply & fixing, 4mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge.
S & F 150mm long floor door stopper of aluminium alloy body and tongue,anodised with hard drawn steel spring complete all as specified & directed.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for Preparation of old wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified & directed by Engineer-in- charge.
S&F for powder coated aluminium frame for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of poweder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete in all respect all as specified & directed by Engr-in-Charge. Make of Al Section : Jindal / Hindalco / NALCO
S&F for powder coated anodised aluminiumdoor/window/ ventilator shutters,, aluminium sections weighing exc 0.55 Kg/m including necessary necessary joining cleats, glazing clips, rubber neoprene packing, handles 1 Nos in each door, hinges (02 Nos), anodised aluminium snap beading, screws, complete all as specified Make of Al Section : Jindal / Hindalco / NALCO
supply & fixing, Figured glass, pin head type 4 mm thick and glazing with oil putty in squares not exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290-0 or grade E- 165 complete all as specified and as directed
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described not exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
S&F in repairs for stainless steel drapery rods, standarad quality, not less than 28mm dia with heads, brackets and boths ends stainless caps , etc. all as specified and direced.
S&F in repairs for sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with cromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S&F in repair aluminium hat pegs, solid body, 125 mm to 175 mm (4 legs) complete all as specified and directed by Engineer-in-Charge.
S&F in repair tubular towel rail, Aluminium anodised, 20 mm dia, 'D' type, 60cm long between flanges complete all as specified and as directed by Engineer-in-Charge.
S&F in repair chromium plated fancy type soap dish complete all as specified and directed by Engineer-in-Charge
Supply & fixing in repair vitreous China squatting pan 'Orissa' pattern of size 580mmx440mm white with integral foot rests (excluding flushing cistern) but including CI 'P' trap set in and including concrete bed fixed to existing surface complete all as specified and directed by Engineer-in-Charge.
S&F in repair for PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle flush pipe 32mm dia, for low level cistern of polyethylene of low or high density or PVC, and connection to pipes complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash hand basin coloured Flat back of size 580x450mm, including 32mm dia chromium plated waste coupling long screwed shank and fly nut, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified .
Supply & fixing in repair pillar tap cast copper alloy with capstan head, chromium plated, fancy type screwed down, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply and fix in repair bib taps, cast copper alloy fancy type chormium plated long body fancy type. with Capastan head screwed down screwdd for iron pipe of brass ferrule, and fixed in 15 mm bore dia of pipe complete all as specified and directed by Engr-in-charge.
S&F in repair CP stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair stop cock fancy type cast copper alloy,chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe suitable for size 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve shall be as given in SSR or in relevant IS.
Supply & fixing in repair shower rose 125mm size brass chromium plated with sweivel joint including fixing to steel pipe or union fixed complete all as specified & directed by Engineer-in-charge.
Supply & fixing in repair 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Dismantling of water tanks of capacity exc 250 ltr but n exc 500 ltr and removing from site complete all as specified & directed.
Supply & fixing rotational moulded polyethylene water storage tank (cylindrical vertical tripple layered with closed top), ISI marked hoisted and fixed in position of capacity 500 litres including out let connection complete all as specified & directed by Engineer-in-charge.
S&F in repair for gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 15mm bore complete all as specified and directed
S&F in repair for gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore complete all as specified and directed
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed in 25mm dia bore pipe complete all as specified and directed.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe complete all as specified and directed by Engr-in-charge.
,---ditto--- all as per srl item No 85 above but 20mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
,---ditto--- all as per srl item No 87 above but 20mm dia pipe complete all as specified and directed by Engineer-in-Charge.
,---ditto--- all as per srl item No 87 above but 15mm dia pipe, Fixing only tubes, any grade, to walls and ceilings or laying in floors
,---ditto--- all as per srl item No 88 above but 20mm dia pipe Fixing only tubes, any grade, to walls and ceilings or laying in floors
Dismantling and Disconnecting of existing cast iron pipes 75/100 mm bore fixed to wall or laid in trenches, incl all fitting & accessories if required complete all as specified and directed by EIC.
Taking down eaves gutters and rainwater pipe (any size or pattern) including all connected fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-Charge.
S&F 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed to walls, ceilings or in floors complete all as specified &directed.
S & F in repair stainless steel kitchen plate rack made out with 1 mm thick sheet of size 24"x24"x 10" including taking down existing wooden plate rack complete all as specified and directed by Engineer-in-Charge
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S & F 100 bore of spun cast, cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast iron complete all as specified and directed.
S & F cast iron 100 mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F cast iron 100 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S & F 75mm bore of spun cast, cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast iron complete all as specified and directed.
M & L in repairs of outlet 75 mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1, (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S & F cast iron 75 mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F cast iron 75 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base below floor etc. complete all as specified and as directed by Engr-in-Charge.
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80mm thickness M-35 grade with over sand cushion all as specified and directed. Note: sand filling paid seperately.
Supply only for sand filling under interlocking tiles or in foundation including watering and consolidation all specified and directed
M & L cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in benching /haunching manhole including forming channels Complete all as specified.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:4 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge.
Demolition of brick work or stone /boulders masonry built in cement morter including all quoins, pillars,arches etc but excluding ashlar facing,dressed stone work and precast concrete article including cleaning and stacking servicable brick for re-use and blance removing rubbish from the site complete all as specified & directed.
M&L for brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L in repair for 19mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed by Engineer-in-Charge.
M&L Rolled mild steel in Stairs (framed) including stringers, treades, landing,balusters, hand rails etc. including cleats, brackets, Fe-290 (Gde E- 165) etc.complete all as specified and directed by Engineer-in-Charge.
Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches on PCC bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Cutting into existing manholes for connecting new drains,150 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with Fly Ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sockets, regulator, rusted conduit etc and making good disturbed surfaces of walls and floors etc to match with the existing all as specified and directed by Engineer-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer in Charge.
Taking down sub main wiring for one light point contincluding conduit/casing capping of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces
M&L point wiring for one light point controlled by one switch with 1.5 Sqmm (nominal cross section area) PVC insulated unsheathed multistranded copper conduct cable in and including medium grade rigid PVC concealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3 mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and 1.5 Sqmm single core PVC insulated unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly and making good diturbed surfaces in cement motar 1:3 complete all as specified and directed.
,---ditto--- all as per srl item No 123 above but for one ceiling/exhaust fan point controlled by one, one way switch and regulatorcomplete all as specified & directed
,---ditto--- all as per srl item No 123 above, but for for bell point controlled by one bell push complete all as specified & directed
,---ditto--- all as per srl item No 123 above, but for 3 pin 5 Amp socket outlet on the same board with other switch, sockets complete all as specified and as directed.
,---ditto--- all as per srl item No 123 above, but for one 3 pin 5 Amp socket outlet on independent board complete all as specified & directed
,--ditto--- all as per Serial item No 123 above, but for Two way point controlled by two way switch complete all as specified and directed by Engr-in-Charge.
,---ditto-- all as per item No.123 above but point wiring with 4 sqmm multi stranded conductor cable and 2.5 sqmm unsheathed copper conductor earth wire for two in one 5 pin 15 Amp socket outlet on indep board.
Supply and fix piano swith flush button single pole one way 5 Amps complete all as specified and directed
Supply and fix piano socket 2 in 1, 2/3 pin 6 amp flush type 250 volts AC complet all as specified and as directed
Supply and fix piano socket 2 in 1, 2/3 pin 5 amp flush type 240 volts AC complet all as specified and as directed
Supply and fix piano swith 15 amp flush type 240 volts AC complete all as specified and directed
Supply and fix piano swith flush button single pole two way 6 Amps complete all as specified and directed
Supply & fix batton integrated LED light fitting 1 x20 integral sleek polycarbonate LED channel with white acrylic cover to roof/ceiling/wall with necessary wooden/PVCblocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting complete all as specified and directed including taking down old one. Note : (i) with lumen efficiency in excess of 100 Lumans per watt and driver effeciency >85% (withpf>0.95) (ii) CRI >80
Supply and fix lamp hold insulated body with back plae for angle/batten fitting with LED of 09 watt complete all as specified and directed by Engr-in-Charge.
Supply & fixing bell push flush button 5/6 Amps, 230 volts all as specified & directed.
M & L for Modular Bell push switches 6Amp 1 module, 230 volts AC single pole complete all as specified and directed by Engr-in-Charge.
M & L for Ceiling rose surface bakelite two to three terminals/plate 5 amps, 3 phase/PVC/ polycarbonate, isolated body etc complete all as specified and directed by Engr-in-Charge.
S & F stepped type electronic fan regulator flush type 80/100 watt on the existing phenolic laminated sheet, suitable for 1200/1400mm sweep ceiling fan working on 230 volt AC as reqd etc all as specified and as directed by Engr-in-charge.
Supply and fix verticle MCB DB 3 phase Triple pole and neutral (TPN) for 415 volts, 4 ways, double door with bus barrating 200 Amp vertical type dust and vermin proof, including fixing on wooden board or recessed on wall complete all as specified and directed
Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door complete all as specified and directed
Supply and fixing MCB single pole 240 volt 5-32 amps 10 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
Supply and fixing MCB SPN 240 volt 5 to 32 amps 10 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
Supply and fixing MCB single pole 240 volt 40 amps 10 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
Supply and fixing PVC Blanking Plates with internal lock complete all as specified and as directed.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLS PVC insulated multistrand copper conductor drawn through and including PVC conduit 25mm dia (heavy duty) including one run 4 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, junction box, terminal box, tee, bend etc. including taking out/down rusted conduit, including making good disturbed surfaces of walls/ceiling etc. complete all as specified and as directed by Engineer-in-charge. Note :-Two run of 6 Sq mm, one run of 4 sqmm copper wire and one run conduit shall be measured as one length.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
Supply and fix sheet metal incl single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volts Complete incl necessary fixing arrangement and all incoming and outgoing electric connection all as specified and directed by Engr-In-Charge
M&L for repair to door hinges of MS housing of size 900x600 mm incl necessary welding and painting the panel with two coat of synthatic enamelled paint over a coat of red oxide primer complete all as specified and as directed.
Supply & fix fresh air fan 230 mm sweep, single phase 230v 50 Hz plastic body with louvers, including grouting with fasteners, nuts/bolts etc complete all as specified and directed by Engineer-in-Charge
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) after dismantling old items fan, sealing cable end, blades and removing fan and blades to deposite to MES store etc complete all as specified and directed by Engineer-in-Charge
S&F exhaust fan 300 mm sweep with steel body louvers AC single phase 230/240 volts after dismantling old items deposite to MES store etc complete all as specified and directed by Engineer-in-Charge
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
ram rattan dass aggarwal
M/S Shree Ram Enterprises
PAREEK AND COMPANY
Aggarwal brothers and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .