Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹94.6 LAccepted-AOC | 1st | Accepted-AOC responsive bidder | |
| 2 | 2nd₹96.4 L+₹1.8 L (1.86%)Rejected-Finance NOT AVAILABLE | NEW DELHI | DELHI | 110001 | 2nd | Rejected-Finance higher than lowest bidder | |
| 3 | 3rd₹96.4 L+₹1.8 L (1.87%)Rejected-Finance | 3rd | Rejected-Finance higher than lowest bidder |
Tender Value
₹91.0 L
EMD Value
₹1.8 L
Closing Date
13 Dec 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Moga
Room no. 312 Jhelum cheenab building DAC Complex Moga
Aug. of Wss at vill. Talwandi Mallian
2021_WSS_77118_1
2021/Nabard/TalwandiMallian/1
Open Tender
Civil Works - Water Works
Item Rate
270 days
Vill. Talwandi Mallian
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
₹1.8 L
11 Jan 2022
23 Nov 2021
13 Dec 2021
23 Nov 2021
13 Dec 2021
23 Nov 2021
90 days
Amount
Repair of Existing OHSR 30000 glns. Capacity (Zone-1)
Providing & fixing Top Jali complete
Providing & fixing manhole cover with locking arrangement complete
Repair of Expansion joints of 4 no.
Prov. Aluminium ladder in side tank portation
Repair of tank side wall, dome and riling and lighting conductor etc complete in all respect
Construction of New RCC OHSR- Zone-11
Constructing one No. of 50 KL (50000 litres) Capacity with sill level not less than 17.00m height upto FSL 20.00 mtr ground level, complete with external RCC stair case with landing slabs at each staging, RCC roofs, ventilator, single manhole cover, lightening conductor, plinth protection, water level Control device, to be connected to existing pipeline network etc. complete duly tested and handed over in proper working order to the satisfaction of Engineer-Incharge. The construction of OHSRs shall be as per standard drawings/design of DWSS. Cost of conducting soil bearing capacity test shall be borne by the bidder. However, if (i) the height of Sill Level and FSL of OHSR to be constructed is more than the standard drawings/design. (ii) the bearing capacity at site after allotment comes out to be less than 8.75 t/sq.m. Then the contractor shall submit revised design from reputed Engineering Institute to fulfill the requirements of additional height and less Bearing Capacity at site. However, key parameters of OHSR like tank portion diameter and center to center distance of columns etc. shall NOT be reduced. The revised structural design shall NOT be downward revised in any case. The responsibility for structural safety of OHSR(s) shall be of the contractor. Nothing extra shall be paid to the contractor on account of increase in height of OHSR and cost of submission of revised design/drawings. However, in case of variation due to upward revision in the design due to lesser bearing capacity encountered at site than 8.75t/sqm, then the additional quantities for items of work which that could have to be executed on account of less Bearing Capacity than 8.75 t/sqm shall be paid at CSR plus ceiling premium applicable at the time of tendering. The lump sum rates should also included the cost of all material like cement, steel, fine aggregate, coarse aggregate, scaffolding, shuttering labour etc, whatsoever. Providing and installing inlet, outlet, scour and over flow D/F DI Pipes as per (IS 8329 with latest amendments), including the cost of DI Specials like Duck foot bend, DI Double Flange S.Vs., one each with inlet, outlet, scour pipe along with construction of suitable size haudies and C.I/D.I D/F expansion Joints, Bell mouth and Flanged Puddle Collar. All the pipes & specials shall be duly ISI marked. These lump sum rates shall also include lightening conductor, aluminum and steel ladder, Prov. & fixing GI railing, nut and bolts and all other specials and accessories whatsoever, complete in all respects to the entire satisfaction of Engineer-in-charge
Pumping Main- Zone-II
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (CSR item 28.1, 28.13 (iv) & 28.18)
110mm o/d pipe of 10 kgf. / sqm.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) (CSR item No. 28.27 A (b))
100mm i/d sluice valves flanged
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (2 no. each of size 0.9m x 0.9m (CSR item No. 28.66(b))
Dist. System - Zone-I
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mannual Earth work). (CSR item 28.1, 28.13 & 28.18 )
PVC pipe 63 mm 6kgf/squm o/d
PVC pipe 90 mm 6kgf/squm o/d
PVC pipe 110 mm 6kgf/squm o/d
PVC pipe 160 mm 6kgf/squm o/d
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mech. Earth work). (CSR item 28.1, 28.13 & 28.18 )
PVC pipe 63mm o/d 6kgf/squm
PVC pipe 90mm o/d 6kgf/squm
PVC pipe 110mm o/d 6kgf/squm
PVC pipe 160mm o/d 6kgf/squm
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous coruse 50 to 75 mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respacts as per analysis A-26. NOTE:- Contractor shall quote rates only for dismantling mattle road and back filling with excavated earth, fully compacted. The restoration of the mattled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/Pnnchayti Raj.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge) (CSR item No. 28.27 (a))
80 mm I/d sluice valves flage
100 mm I/d sluice valves flage
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 14No. With each of Size 0.6m x 0.6m (CSR item 28.66)
Connection of new pipe line with existing pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects.
Dist. System - Zone-II
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mannual Earth work). (CSR item 28.1, 28.13 & 28.18 )
PVC pipe 63 mm o/d
PVC pipe 90 mm o/d
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mech. Earth work). (CSR item 28.1, 28.13 & 28.18 )
PVC pipe 63mm o/d
PVC pipe 90mm o/d
PVC pipe 110mm o/d
PVC pipe 160mm o/d
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous coruse 50 to 75 mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respacts as per analysis A-26. NOTE:- Contractor shall quote rates only for dismantling mattle road and back filling with excavated earth, fully compacted. The restoration of the mattled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/Pnnchayti Raj.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge) (CSR item No. 28.27 (a))
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 8 No. With each of Size 0.6m x 0.6m (CSR item 28.66)
Connection of new pipe line with existing pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects.
Water Connection - Zone-I with watermeter
Providing proposed water connection to house hold up to wall (, providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.00+2.50 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVC clamp complete and Providing, fixing & jointing water meter of approved make as per IS:779/94 in G.I. Pipe line including cutting and threading pipe, Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats including specials etc. complete in all respects.
Water Connection - Zone-II with watermeter
Providing proposed water connection to house hold up to wall (, providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVC clamp complete and Providing, fixing & jointing water meter of approved make as per IS:779/94 in G.I. Pipe line including cutting and threading pipe, Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats including specials etc. complete in all respects.
Chlorinator for Zone-I and II
Prov. & Instaling , testing & commissioning one No Electronically actuated, Diaphram Operated , Metering System, Chemical Dosing Chlorinator , suitable for delivering 0.5 to 6 liter of Bleaching Powder solution /Sodium Hypo soiution per our under maximum delivery pressure up to 7 Kg.cm 2 ,and suction lift not less than 1.5 m ,as per DWS stanard specifications.
Repair of Pump Chamber for Zone-I
Repair of existing brick masonry pump chamber of size 3.05 x 3.66 mtr. . complete in all respect as per W/S & Sanitation Deptt. standard design & drawings. (Detail Attached)
CI fitting for Zone-II
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 1 & Drawings D-12 & D-17.
Construction of V- Notch Houdi (Size 1.80 x 0.90 m) excluding cost v – notch as per standard design & drawings of Public health Department
Development of Water Works for Zone-I
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6) 61+61+61+61 MTRS
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-7
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-3.
Repair of existing MS Sign Board including painting and writing etc.. as per standard size of DWSS as per analysis A-24 & Drawing D-20
Development of Water Works for Zone-I
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7 & Analysis A-10.
Repair of existing MS Sign Board including painting and writing etc.. as per standard size of DWSS as per analysis A-24 & Drawing D-20
Markanda Electrical Works
Sarwan Kumar Saini
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .