Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Contract is awarded to M/s Sai Construction | |
| 2 | L2₹31.8 L+₹3.4 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest quoted rate | |
| 3 | L3₹46.4 L+₹18.1 L (63.9%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest quoted rate |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
1 Feb 2024, 6:00 pmClosed
Shri Prakash G Kaleka AE (QSandC) AGE (Contracts)
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIR / MAINT OF DG SETS, VOLTAGE STABILIZERS, WASHING MACHINES, AIR COMPRESSORS, SECURITY LIGHTS, REFRIGERATORS, WATER COOLERS, WINDOW/SPLIT ACS, DESERT COOLERS, DEEP FREEZERS ETC AT AURANGABAD UNDER GE (SOUTH) AHMEDNAGAR
2024_MES_635641_1
8138/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AURANGABAD
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
23 Feb 2024
3 Jan 2024
3 Feb 2024
3 Jan 2024
1 Feb 2024
17 Jan 2024
3 Jan 2024 - 10 Jan 2024
Amount
M&L for checking, inspection, maintanance and servicing of 100 KVA DG set complete including replacement of unserviceable spare parts of the DG set (comprising of Engine/ Alternator/ Control panel) for smoth functioning complete all as per Manufacturer's instructions and all as specified and as directed. A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tension properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) Checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) Checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings. B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes. NOTES (a) Cost of Spare parts required shall be paid and measured separately (b) Servicing/routine check up shall be carried out through authorised service centre of Manufacturer (c) Make of spares shall be as recommended by authorise service centre of Manufacturer.
All as per serial Item No 1 but for 40/30 KVA DG Set
All as per serial Item No 1 but for 15 KVA DG Set
S&F in repairs, Oil Filter Element with 'O' ring washer for 100 KVA DG Set as per sample complete all as specified and as directed .
All as per serial item No 4 but for 40/30 KVA DG Set
All as per serial item No 4 but for 15 KVA DG Set
S&F in repairs, Fuel filter Element (Primary & Secondary) as per sample for 100 KVA DG Set complete all as specified and as directed .
All as per serial item No 7 but for 40/30 KVA DG Set
All as per serial item No 7 but for 15 KVA DG Set
S&F in repairs, Air Cleaner Assembly (inner & outer) as per sample suitable for 100 KVA DG Set complete all as specified and as directed
All as per serial item No 10 but for 40/30 KVA DG Set
All as per serial item No 10 but for 15 KVA DG Set
S&F in replacement, fuel pipe with banjo bolt at both side suitable for 100 KVA DG sets complete all as specified and as directed.
All as per serial item No 13 but for 40/30 KVA DG Set
All as per serial item No 13 but for 15 KVA DG Set
S&F in replacement, 'V' belt for radiator/water pump as per sample suitable for 100 KVA DG Sets complete all as specified and as directed.
All as per serial item No 16 but for 40/30 KVA DG Set
All as per serial item No 16 but for 15 KVA DG Set
S&F in repairs, Dynamo as per sample of 100 KVA DG set complete all as specified and as directed .
All as per serial item No 19 but for 40/30 KVA DG Set
M&L for changing /toping up of best quality of engine oil 20W40/10W30 type for various type/capacity DG set including removing of old burnt engine oil from DG Sets complete all as specified and as directed
S&F in replacement, water pump assembly for 100 KVA DG sets complete all as specified and as directed.
All as per serial item No 22 but for 40/30 KVA DG Set
S&F in replacement, self starter for 100 KVA DG Set complete all as specified and as directed.
All as per serial item No 24 but for 40/30 KVA DG Set
Supply and filling distilled water in batteries of DG set complete all as specified and as directed.
S&F in replacement, auotmatic voltage regulator (AVR) 24 volt suitable for 100 KVA DG Sets complete all as specified and as directed.
All as per serial item No 27 but for 40/30 KVA DG Set.
All as per serial Item No 27 but for 15 KVA DG Set.
S&F in replacement, lub oil pump suitable for 100 KVA DG Sets complete all as specified and as directed.
All as per serial item No 30 but for 40/30 KVA DG Set
All as per serial item No 30 but for 15 KVA DG Set
S&F in replacement, air hose set with all necessary fittings for 100 KVA DG Sets as per sample complete all as specified and as directed.
All as per serial item No 33 but for 40/30 KVA DG Set
All as per serial item No 33 but for 15 KVA DG Set
S&F in replacement, fan hub assembely for 100 KVA DG Set complete all as specified and as directed.
All as per serial item No 36 but for 40/30 KVA DG Set
S&F in replacement, water hose pipe set with all necessary fittings for 100 KVA DG set as per sample complete all as specified and as directed.
All as per serial item No 38 but for 40/30 KVA DG Set
All as per serial item No 38 but for 15 KVA DG Set
M&L for taking out burnt winding of exciter of 100 KVA DG set with and including rewinding copper wire of super quality of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and as directed.
All as per serial item No 41 but for 40/30 KVA DG Set
All as per serial item No 41 but for 15 KVA DG Set
M&L for cleaning of radiator for 100 KVA DG sets by using Keroscene oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush including necessary welding/brazing work to the leakage if required complete all as specified and as directed.
All as per serial item No 44 but for 40/30 KVA DG Set
All as per serial item No 44 but for 15 KVA DG Set
M&L for complete wiring to LT panel of DG set of any capacity with all connected items and replacement of voltmeter, ammeter,RPM & HRS meter with digital display, oil pressure gauge, oil temperature gauge, solenoid switch, LED type indicator lamp set of three including CT PT for 3 phase amperemeter upto capacity of 60 Amp including taking down old wiring and voltmeter, ammeter, RPM & HRS meter with digital display, oil pressure gauge, oil temperature gauge, solenoid switch, LED type indicator lamp set of three complete all as specified and as directed.
S&F in replacement, oil pressure gauge DG set of capacity up to 100 KVA complete all as directed.
S&F in replacement of thermostate valve suitable for 100 KVA DG Sets complete all as specified and as directed.
All as per serial item No 49 but for 40/30 KVA DG Set
All as per serial item No 49 but for 15 KVA DG Set
S&F in replacement, oil seal front and rear suitable side for 100 KVA DG Sets complete all as specified and as directed .
All as per serial Item No 52 but for 40/30 KVA DG Set
All as per serial Item No 52 but for 15 KVA DG Set
S&F in replacement, battry terminal for DG set complete all as specified and as directed .
Supplying and laying 2.50mm thck synthetic rubber insulated mat of size 2m x 1m for voltage up to 11 KV for electrical purpose as per IS 15652-2006, (Superseding IS-5424) suitable for electrical shock safety complete all as specified and as directed .
M&L for calibration of FIP including supply & fix in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing for 100 KVA DG Set complete all as specified and as directed.
All as per serial item No 57 but for 40/30 KVA DG Set
M&L in replacement, exhaust silencer of 100 KVA DG set complete all as specified and as directed.
All as per serial Item No 59 but for 40/30 KVA DG Set
Supply and filling of best quality Coolant liquid for DG set of any capacity and at any location complete all as specified and directed.
S&F in replacement, radiator cap for 100 KVA DG set all as specified and as directed.
S&F in replacement, radiator cap for 40/30 KVA all as specified and as directed.
S&F in replacement, outer glass and gasket as required at site for 100 KVA all as specified and as directed.
S&F in replacement, solenoid switch for 100 KVA DG sets all as specified and as directed.
S&F in replacement, solenoid switch for 40/30 KVA DG sets all as specified and as directed.
S&F in replacement, solenoid switch for 15 KVA DG sets all as specified and as directed.
S&F in replacement battery cable assembly with copper conductor multistranded RED and BLACK colour 2m long, 16 sqmm for connection to self starter unit to battery unit complete all as specified and as directed.
M&L for draining out from the fuel tank of 100 KVA DG Set and keeping it in a separate container, cleaning the fuel tank all internally & externally by removing all the accumulated sediments, leak testing the tank and welding/brazing including one coat of black synthetic enamel paint over a coat of red oxide primer and refixing the tank to its original position & refilling the fuel back into the tank complete all as specified and as directed.
All as per serial item No 69 but for 40/30 KVA DG Set
All as per serial Item No 69 but for 15 KVA DG Set
M&L for prepration of old surfaces of 100 KVA DG set by rubbing with fine emery paper and making the surface smooth and painting the same with two coats of super quality synthetic enamel paint by spray gun fully matched with its original colour and making good entire DG Set ( Engine, Alternator, foundation, Diesel Tank and Radiator unit including canopy) with and including marking SM/MES No on DG Set with diffrent paint maintaning colour code complete all as specified and as directed.
All as per serial item No 72 but for 40/30 KVA DG Set
S&F in replacement, display board (double sided) of size 1.0m x1.0m x 0.30m made with flax material mounted on suitable iron frame & printing of installation detail both side of the board, Printing detail/ installation detail provided by JE/AGE including fixation of 4x20 Watt LED light inside the board and also arrangement connection wire from the nearest LT panel/pole complete all as specified and as directed.
M&L for denting, welding/fixing of hinges, replacement of damaged door (made up of 3.15mm thick steel sheet) of indoor/outdoor panel door of various capacity, preparation of old/new surfaces of panel box and applying two coats of synthetic enamel paint all as specified and as directed.
M&L in replacement for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2020(Part-I) complete all as specified and directed.
S&F in replacement, on load change over switch, 415 Volt in sheet metal enclosure, 4 Pole of capacity, 63 Amps with connecting acessories complete all as specified and as directed.
S&F in replacement, on load change over switch, 415 Volt in sheet metal enclosure, 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and as directed .
S&F in repairs, power contactors of AC1 upto 210 Amps 3 Pole 415 volts all as specified and as directed.
S&F in repairs, power contactors of AC 3 upto 210 Amps, 3 Pole, 415 volts all as specified and as directed.
S&F in replacement, post top lantern LED type 20 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including suitable size of GI pipe as per lamp size including connection and testing complete all as specified and as directed .
Taking down old unserviceable street light fittings from street light poles of any type/gun shed for repairs and refixing the same in existing position after repair including testing complete all as specified and as directed. Note- Parts/Items as required for repairs and replacement shall be measured and paid separately under respective item.
S&F in replacement, driver for LED street light, 20 Watt to 50 Watt complete all as specified and as directed.
S&F in replacement, driver for LED street light, 50 Watt to 160 Watt complete all as specified and as directed.
S&F in replacement, bracket for street light, made out of GI pipe, medium grade of suitable size (40 mm dia and 1.2 mtr long), bent to shape, fixed with and including necessary heavy duty clamps of suitable size including painting the clamps with two coats of synthetic enamel paint over a coat of primer all as specified and as directed.
S&F in replacement, LED street light fitting 60 Watt, 230 Volt, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including PVC copper wire 1.5 sqmm of suitable length for connection of street light from overhead conductor /junction box complete all as specified and as directed.
All as per serial item No 86 above but for 70 Watt 230 V AC street light .
All as per serial item No 86 above but for 90 Watt 230 V AC street light .
All as per serial item No 86 above but for 120 Watt 230 V AC street light .
S&F in replacement, LED flood light fitting 70 Watts, having pressure die cast housing with IP 65 efficient high outout emitter LED for better distribution, protection with heat resistant toughned glass with individual LED lenses complete including making connection with flood light box or OH line using PVC insulated and sheathed single core multi stranded aluminium conductor cable of size 1.5 sqmm including MS clamps nuts, bolts and washers of required size complete all as specified and as directed.
All as per serial item No 90 above but for 100 Watts, 230 Volts AC LED flood light fitting
All as per serial item No 90 above but for 120 Watts, 230 Volts AC LED flood light fitting
S&F in replacement, FRP Junction box, light weight, low corrosive suitable for pole mounting including MCB SP 6/10 Amps, box size not less than 250x200x100 mm including necessary connection for loop in and loop out cable connector and suitable size for cable glands complete all as specified and as directed.
S&F in replacement, timelite distribution board with 40 Amp 3 pole 230 Volt type digital Astro type timer light switch along with 40 Amps contactor, MCB, TPN 40 Amps and all other accessories i.e lugs, cable connection etc all as specified and as directed.
S&F in replacement, analog street light timer switch (with battery back up) electronic type with digital display suitable for Indian region longitude/latitude with 24 hours operation settings including single phase contactor suitable for current capacity 16 Amp with 1 change over complete with all accessories and prewired suitable for a panel / pole mouting box complete all as specified and as directed.
Supply, laying and testing 50 Sqmm 3.5 Core, XLPE insulated, PVC sheathed, ISI marked, earthed system, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade, laid in trenches /wall/ floor/pole complete and making connection including suitable size aluminium lugs including taking out existing cable and cable covers all as specified and as directed.
All as per serial item No 96 but 35 Sqmm 3.5 Core, XLPE Cable
All as per serial item No 96 but 25 Sqmm 3.5 Core, XLPE Cable
All as per serial item No 96 but 16 Sqmm 2.0 Core, XLPE Cable
All as per serial item No 96 but 10 Sqmm 2.0 Core, XLPE Cable
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations/laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and deposting where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for Double Walled Corrugated (DWC), HDPE pipe of outer dia 50mm and internal dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches, suitable for cable protection of size 2 core 10 sqmm to 3.5 core 70 Sqmm complete all as specified and as directed.
S&F in replacement, globe LED post top in spherical shape polycarbonate opal and clear diffuser with IP 65/66 protevtion of 25 watt in warm white colour with suitable size of GI pipe, length as per site requirement for fixing of lights including PCC base for fixing of lights with proper nut, bolts & electric connection wire complete all as specified and as directed.
S&F 1100 volts grade heavy duty multi stranded aluminium solid conductor cable, PVC insulated served with inner sheathing of PVC tape and overall PVC sheathed in service connection flate/circular cable of sizes 4 Sqmm 2 core laid and jointed in position including taking out existing service cable all as specified and as directed.
All as per serial item No 106 but 6 Sqmm 2.0 Core, PVC cable
Disconnecting electric and water supply connection of centrifugal pump of any capacity for repairs such as cleaning, servicing, repair of leakage/ unserviceable parts any type and reconnecting all electric and water supply connections and testing complete all as specified and as directed. Note : Cost of repair, servicing and spare parts shall deemed to be included in the unit rate quoted.
Taking out old unserviceable submersible sewage pump set of capacity 40 HP from underground sewage sump by means of chain pully and transporting to authorised workshop for repair and rewinding the motor with super enamelled insulated copper wire of existing gauge including insulated packing, liquid compound, differential oil-4.5 ltrs, repalcement of oil seal and motor/pump bearing, replacement/repair of motor and pump shaft made out of high quality stainless steel and re-assembling and installing back at it's original position, aligning, testing and commissioning on full load for 8 hrs continuous running all as specified and as directed.
Disconnect electric supply, dismantling coupling and remove compressor upto 40 HP, shifting to local workshop for repair / servicing, opening up the compressor unit, dismantle and remove damaged twin lobo air compressor, piston, piston connecting rod, rings etc and replace with new one, reconditioning / welding / filling / grinding / lathework to shaft of the compressor unit, supply & replace suitable size bearing of make : SKF - 2Nos, drain out the out dated compressor oil, cleaning the oil chamber thoroughly by removing the sludges from the oil sump, replace with new compressor oil of specified gravity - 4 Litres, supply & replace air filters of suitable size - 2 Nos, reassembling with new gasket set, transporting back to the original location, coupling, aligning, supply and replace worn out V - belts ( B-72) of make : Fenner - 3Nos, and reinstalling at sie, connecting, testing & commissioning complete all as specified and as directed.
Taking LT shutdown, dismantling and removing the 10 HP, 3 phase electric motor from existing foundation / position, shifting to authorized workshop for repair work, removing the burnt winding, cleaning rotor / stator slots, rewinding the motor with super enamelled copper wire of the size equivalent to the original winding including insulated packing materials, varnishing, heating, drying etc, replacing the bearings, reassembling the motor, transporting to site of work and reinstalling back at it's original position, aligning, testing and commissioning on full load for 8 hrs continuous running complete all as specified and as directed.
Taking LT shutdown, dismantling and removing the upto 5/5.5 HP, 3 phase electric motor from existing foundation / position, shifting to authorized workshop for repair work, removing the burnt winding, cleaning rotor / stator slots, re-winding the motor with super enamelled copper wire of the size equivalent to the original winding including insulated packing materials, varnishing, heating, drying etc, replacing the bearings, reassembling the motor, transporting to site of work and reinstalling back at it's original position, aligning, testing and commissioning on full load for 8 hrs continuous running complete all as specified and as directed.
M&L for scrapping the old painting and removing the grease, oil, dirt etc, filling the cavities of exposed surfaces of pump, motor,sand filter,ladder, gate and pipe line and spray painting with two coats of super enameled anti corrosive paint of approved colour (according to colour code at STP area ), over a coat of primer after taking proper shutdown of LT pannel and restoring of supply after completion of the work all as specified and as directed.
M&L for cleaning vegetation/grass and bushes with roots in the STP installation area, removing the garbage and deposited at distance not exceeding 100m all as specified and as directed .
M&L for filter media plastic round pieces which is use in fabrication tank to settled down bacteria in it complete all as specified and as directed.
Cleaning, checking and servicing of aerobic tank open well of size 5 m dia and 12 m depth, disposal of wastage away from STP area and necessary connected works for proper working system complete all as specified and as directed.
Cleaning, checking and servicing of collection sump of size 5 mtr dia and 12 mtr depth, disposal of wastage away from STP area and necessary connected works for proper working system complete all as specified and as directed.
Cleaning, checking and servicing of equilization tank of size 13 mtr dia and 3 mtr height, disposal of wastage away from STP area and necessary connected works for proper working system complete all as specified and as directed.
Cleaning, checking and servicing of chamber and Fab - I tank of size 5 mtr dia and 6 mtr height, disposal of wastage away from STP area and outgoing pipe net and to stop flow of filter media from fabrication tank to tube settler tank complete all as specified and as directed.
Cleaning, checking and servicing of chamber and Fab - II tank of size 5 mtr dia and 6 mtr height, disposal of wastage away from STP area and outgoing pipe net and to stop flow of filter media from fabrication tank to tube settler tank complete all as specified and as directed.
Cleaning, checking and servicing of sludge tank of size 2mtr x 2mtr x 5mtr depth, disposal of wastage away from STP area and outgoing pipe net and necessary connected works for proper working system complete all as specified and as directed.
Cleaning, checking and servicing of sludge sump, tube settler tank and resetelling the tube setter tank of size 6.5mtr dia and 5 mtr height, disposal of wastage away from STP area and outgoing pipe net and necessary connected works for proper working system complete all as specified and as directed.
Cleaning, checking and servicing of primary, secondary & filter tank of size 10mtr x 6mtr x 3mtr height, disposal of wastage away from STP area and outgoing pipe net and necessary connected works for proper working system complete all as specified and as directed.
Thorough checking and servicing of pressure sand filter and pressure activated carbon filter complete all as specified and as directed.
S&F in repairs, PVC flexible hose pipe 100 mm bore complete all as specified and as directed.
M&L for removal of blockage and leakage of pipe line, checking and servicing from sludge sump to sludge tank to centrifugal pump set, taking down and refixing of pipe line after clearing the blockage of pipe line in STP area and necessary connected works for proper working system all as specified and as directed.
Repair/servicing of pressure pump any type and capacity complete all as specified and as directed.
S&F in repairs, 200AH Battery, 12 volts all as specified and as directed
S&F in replacement, LED security light for buildings with single piece new generation energy saving and environmental friendly long life LED, 35 Watt, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07 and all acessories including one bracket made of light grade GI Pipe 32 mm dia, 1.5 mtr long fixed to wall/ pole with two clamps made out of mild steel flat iron 40 mm x 5 mm and connected to nearest electric supply with and including three core 1.5 sqmm aluminium conductor cable of suitable length complete all as specified and as directed.
S&F galvanised,40 mm bore, steel tubing, light grade, ISI marked for protection of under ground cable on pole/wall/under road including taking out old unserviceable pipe complete all as specified and directed by engr in Charge.
Taking down High mast light of any length for repairs or carried out general maintenance including greasing, oiling to electric motor/steel wire rope etc and replacement / tightining of nuts & bolts , including all other repair as per site requirement etc including refixing in its original position and testing on completion complete all as specified & directed. Note : Greasing/Oiling/Nut bolts & all other minor parts shall deemed to be included in the unit rate quoted.
S&F in replacement, MCCB 4 Pole, 63 Amps, 16 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed.
S&F in replacement, MCCB 4 Pole , 125 Amps , 16 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed.
S&F in replacement , MCCB 4 Pole , 160 Amps , 36 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed.
S&F in replacement , MCCB 4 Pole 200 Amps , 36 KA current carring capacity with adjustable thermal magnetic release all as specified and as directed.
S&F in replacement of MCB C Curve TPN 40-100 Amps, 415 V complete all as specified and as directed.
S&F in repairs, 3 pole power contactor ML-3 having AC3 Rating 40 Amps with 2 NO + 2 NC auxilliary contacts, all as specified and as directed.
Disconnecting electric connection, taking out and transporting to workshop old unserviceable motor from High Mast light of capacity 2/3 HP for repair/replacement, opening up the motor and rewinding with suitable gauge of super enamelled copper wire of 'F' class insulation , warnishing heating & replacement of worn out parts such as motor bearings, fan blade, reassembling after painting by preparing the surface, scrapping the old painting and removing the grease, oil, dirt etc, filling the cavities, spray painting with two coats of super enameled anti corrosive paint of approved colour, over a coat of primer transporting the repaired motor back to the original location, reinstalling, testing & commissioning complete all as specified and as directed. Note :- Any nut/bolts/ studs and packing required shall deemed to be included in the rates quoted.
S&F winch handle of suitable dia & size for opearating high mast light up & down complete all as specified & as directed.
S&F in replacement, steel wire rope of 6 mm dia 7/19 gauge including greasing ,oiling tightining of nuts & bolts etc for high mast light of any length complete all as specified and as directed.
Disconnecting electrical connection, dismantling the accessories carefully of 1.5 tonne air conditioner (Window/Split type) and transporting to workshop if required for repairs, cleaning the air filters and exposed surface and refixing the air conditioner in its original position after repairs and testing all as specified and as directed. Note : (a) The parts to be replaced shall be make of AC under repair (b) Spare parts shall be measured and paid separately as supply and fixed in repairs.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of window type Air conditioner 1.5/2.0 Ton capacity, any make & model and supply and fixing new compressor of same make as existing for window type air conditioner 1.5/2.0 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed .
Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 1.5/2.0 Ton capacity any make & model and supply and fixing new compressor of same make as existing for split type air conditioner 1.5/2.0 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed .
S&F in repairs, starting relay for 1.5/2.0 TR air conditioner complete all as specified and as directed.
S&F in repairs, gas regulating valve for 1.5/2.0 TR air conditioner complete all as specified and as directed.
S&F in repairs, over load protection relay for 1.5/2.0 TR air conditioner complete all as specified and as directed. .
S&F in repairs, thermostate switch for 1.5/2.0 TR air conditioner complete all as specified and as directed. .
S&F in repairs, starting capacitor 80/100 Mfd for 1.5/2.0 TR air conditioner all as specified and as directed. .
S&F in repairs, running capacitor 36 Mfd for 1.5/2.0 TR air conditioner complete all as specified and as directed. .
S&F in repairs, front panel PVC grill type for 1.5/2.0 TR air conditioner complete all as specified and as directed. .
S&F in repairs, air filter for 1.5/2.0 TR air conditioner complete all as specified and as directed.
Supply only in replacement, remote control as per existing model suitable for AC of any capacity all as specified and as directed. .
S&F in repairs, blower motor, 230 V, AC, 50 HZ, single phase complete with blower fan for split type AC of 1.5/2.0 TR capacity of any make complete all as specified and as directed.
S&F in replacement PCB card suitable for 1.5/2.0TR capacity of split AC's complete all as specified and as directed .
S&F in repairs, blower motor 230 V, AC, 50 HZ, single phase complete with fan blade, 230 volts, suitable for 1.5/2.0 TR window type AC, any make all as specified and as directed.
S&F in repairs, evaporator suitable for 1.5TR window type AC, any make all as specified and as directed.
Taking out window/split AC any type for servicing and cleaning with vaccume cleaner/soft brissle brush/washing as required and removing all dirt, checking wiring and other components and refixing the same in it's position including testing on load complete all as specified and as directed.
Disconnecting electrical connection, dismantling the accessories carefully of 165 to 310 Ltrs capacity refrigerator, any type/make and transporting to workshop if required for repairs, cleaning the exposed surface and refixing the refrigerator in its original position after repairs and testing all as specified and as directed. Note : (a) Parts to be replaced shall be make of refrigerator under repair. (b) Parts shall be measured and paid separately as supply and fixed in repairs.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of refrigerator upto 165 ltrs capacity, any make & model and supply and fixing company repaired compressor of same make for refrigerator, soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and as directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of refrigerator above 165 ltrs and upto 310 ltrs capacity, any make & model and supply and fixing company repaired compressor of same make for refrigerator, soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and as directed.
S&F in repairs, starting relay for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, thermostatic switch auto type for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, condenser coil unit with necessary fixing arrangements and testing for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, lamp 15 watt with holder and bracket for 165 to 310 Ltrs capacity refrigerator complete all as specified and as directed.
S&F in repairs, freezer assembly and testing for 165 to 310 Ltrs capacity refrigerator complete all as specified and as directed.
S&F in repairs, freezer door handle with springs/hinges for 165 to 310 Ltrs capacity refrigerator complete all as specified and as directed.
S&F in repairs, magnetic rubber gasket for 165 to 310 Ltrs capacity refrigerator complete all as specified and as directed.
S&F in repairs, bottle shelves for 165 to 310 Ltrs capacity refrigerator complete all as specified and as directed.
S&F in repairs, vegetable tray for 165 to 310 Ltrs capacity refrigerator complete all as specified and as directed.
S&F in repairs, cabinet shelves for 165 to 310 Ltrs capacity refrigerator complete all as specified and as directed.
Disconnecting water and electrical connection, dismantling the accessories carefully of water cooler, 40-80 Ltrs and 120-160 Ltrs of any type and make and transporting to workshop if required for repairs, cleaning the exposed surface and refixing the water cooler in its original position, connecting up of water/electric connections after repairs and testing all as specified and as directed. Note : (a) Parts to be replaced shall be make of refrigerator under repair. (ii) Parts shall be measured and paid separately as supply and fixed in repairs.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 40-80 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 40-80 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and as directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 120-160 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 120-160 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and as directed.
S&F in repairs, condensing coil unit suitable for water cooler of cap 40-80 litre complete all as specified and as directed.
S&F in repairs, condensing coil unit suitable for water cooler of cap 120-160 litre complete all as specified and as directed.
S&F in repairs, relay for water cooler any capacity complete all as specified and as directed.
S&F in repairs, over load protector relay for water cooler any capacity complete all as specified and as directed.
S&F in repairs, thermostat switch suitable for water cooler any capacity complete all as specified and as directed.
S&F in repairs, condenser motor with blade and fixing brackets with complete assembly for water cooler complete all as specified and as directed.
S&F in repairs, capacitor 10 mfd including necessary electrical connections, lugs, insulation tape etc complete suitable for water cooler of any capacity, all as specified and as directed.
S&F in repairs, running capacitor 36 Mfd for water cooler complete all as specified and as directed.
S&F in repairs, wiring kit for internal connections for water cooler complete all as specified and as directed.
S&F in repairs, push cock/lift cock of brass, 15 mm dia with chromium plated, self closing type with back plate assembly, suitable for water cooler of any capacity complete all as specified and as directed.
S&F in repairs, float vlave assembly, 15 mm dia with brass body and polythene float ball, high pressure type suitable for water cooler complete all as specified and as directed.
S&F in repairs, stainless steel water tray, double tap type including 20mm bore drain out plug suitable for water coller complete all as required at site and as directed.
S&F in repairs, 20/15 mm bore, UPVC drain out pipe not exceeding 1.5 mtr length including necessary fitting/accessories as required at site complete all as specified and as directed.
M&L for cutting and removing the corroded portion of the water cooler body(outer cover), any make and providing 3mm thick stainless steel sheet in corroded portion and fixing/rebetting/brazing with existing sheet including fixing of all accessories complete all as directed.
M&L for prepartion of surface and removing dents & spray painting to water cooler of any size and type/make with two coats of synthetic enamel paint over one coat of red oxide primer and writting SM/MES No. with back paint complete all as specified and as directed.
M&L in repairs for water cooler/refrigerator stand of suitable size as required, made out of 40mm x 40mm x 6mm mild steel angle iron & 40mm x 6mm mild steel flat iron duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F in repairs, door rubber gasket for water cooler of any type complete all as specified and as directed.
M&L in repairs, rewinding of fan motor suitable for water cooler of any capacity of any make with super enameled copper wire of existing size and weight as required including replacement of bushing and capacitor complete all as specified and as directed.
S&F in repairs, fan motor, 1/5 HP, 240 volts, single phase, AC supply, suitable for water cooler of any capacity all as specified and as directed.
Disconnecting electrical connection, dismantling the accessories carefully of air cooler/desert cooler of any type/make and transporting to workshop if required for repairs, cleaning the air filters and exposed surface and refixing the air cooler/ desert cooler in its original position after repairs and testing all as specified and as directed. Notes : (a) The parts to be replaced shall make of air cooler/desert cooler under repair. (b) Parts shall be measured and paid separately as supply and fixed in repairs.
M&L in repairs/replacement of fan motor, 3 speed, single phase 230V AC supply, connecting and testing for desert cooler of any type and capacity all as specified and as directed.
S&F in repairs, water circulating pump motor 1/26 HP (Tullu pump) 230 V, single phase, 1440 RPM, suitable for any type of air cooler/desert cooler fixed complete all as specified and as directed.
S&F in repairs, dry grass pads (khas grass), 25 mm thick, fixed at three side of desert cooler complete all as specified and as directed.
M&L for prepartion of surface and removing dents & spray painting to air cooler/desert cooler of any size and type/make with two coats of synthetic enamel paint over one coat of red oxide primer and writting SM/MES No. with back paint complete all as specified and as directed.
S&F in repairs, desert cooler capacitor 4.0 mfd complete all as specified and as directed.
Dismantling the body of desert cooler of 1800/1400 cum/hr capacity by opening/cutting the nut/bolts and taking out old motor and pump for reuse, reassembling the complete desert cooler after repair work and making connection and testing complete all as specified and as directed. Note : Repair work shall be measured and paid separately.
M&L in repairs, old rusted water storage bottom of desert cooler of 1800/1400 cum/hr capacity, made out of 2mm thick mild steel sheet, duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L in repairs, old rusted side panels of desert cooler of 1800/1400 cum/hr capacity, made out of 2mm thick mild steel sheet duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L in repairs, old rusted front panel of desert cooler of 1800/1400 cum/hr capacity, made out of 2mm thick MS sheet duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L in repair mild stee bracket with ring for fan motor including nuts & bolt for desert cooler of any type and capacity all as specified and as directed.
M&L in repairs, fan blade made of aluminium for desert cooler of any type and capacity all as specified and as directed.
M&L in repairs, fan blade made of plastic of superior quality for desert cooler of any type and capacity all as specified and as directed.
S&F in repairs, switch piano, flush type, 6 amp, 230V, AC, one way all as specified and as directed.
M&L in repairs, PVC water distributor with PVC elbow and pipe for desert cooler of any type and capacity all as specified and as directed. Note:- This item includes elbow - 03 Nos, pipe-03 Nos of required length and dia and distributor -01 No and cost of these items shall deemed to be included in the unit rate quoted.
S&F in repairs, 3 speed regulator switch for desert cooler complete all as specified and as directed.
M&L in repairs, mild steel work for cooler stand of required size made out of angle iron 20mm x 20mm x 2mm thickness including two coat of synthetic enamel paint over a coat of red oxide and grouting in to the wall complete all as specified and as directed.
S&F in repairs, mounting frame/ stand suitable for outdoor unit of split AC of any size complete all as required at site all as specified and as directed.
S&F in repairs and connecting PVC insulated and over all sheathed aluminium conductor, 10 sqmm, twin core, flat service connection, one end to be connected at sheet metal enclosure and other end at LT over head line at nearest pole all as required at site and as directed.
S&F in repairs and connecting PVC insulated and over all sheathed aluminium conductor, 6.0 sqmm, twin core, flat service connection, one end to be connected at sheet metal enclosure and other end at LT over head line at nearest pole all as required at site and as directed.
S&F in repairs, metalic plug top, 3 pin for AC point, single phase, 240 volts, AC ISI marked, all as specified and as directed.
S&F in repairs, metalic socket, 3 pin for AC point, single phase, 240 volts, AC ISI marked all as specified and as directed.
S&F in repairs, commercial plywood, 4.0 mm thick, provided in existing window, upto double story bldg, including cutting of plywood to opening size of Desert Cooler/ Window AC etc as required all as specified and as directed. Notes : External dimensions of ply wood shall be measured for payment without any deduction for central opening.
S&F in repairs plug top 3 pin,15 Amp complete all as specified and as directed.
S&F in repairs plug top 3 pin, 05 Amp complete all as specified and as directed.
M&L for repairs to voltage stabilizer 1.0/2.0 KVA ,single phase, 230V, 50Hz, any type including replacement of rectifier, circuit board, relay, indicating lamps, volt meter and socket outlet etc and testing all as specified and as directed.
M&L for repairs to voltage stabilizer 3.0 KVA to 5.0 KVA ,single phase, 230V, 50Hz, any type, including replacement of rectifier, circuit board, relay, indicating lamps, volt meter and socket outlet etc and testing all as specified and as directed.
S&F in repairs sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and as directed .
M&L in repairs, three core copper conductor cable, flexible, of size 2.5 Sqmm for connections complete all as specified and as directed.
M&L in repairs, three core copper conductor cable, flexible, of size 4 Sqmm for connections complete all as specified and as directed.
Supply only refrigeration gas F-22/R-22 (Mefron/Refron) in returnable cylinder complete all as specified and as directed.
Supply only refrigeration gas R-134 (Mefron/Refron) in returnable cylinder complete all as specified and as directed.
M&L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size casing / caping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of casing/caping, complete all as specified and as directed. NOTE: (a) Proper colour coding shall be adopted for wiring (for Phase-Red, Yellow, Blue for Earth - Green and Neutral - Black) (b) Two run of 4 sqmm (one run for phase and one run for neutral) with one run of 4 sqmm cable for earth and one run of PVC casing & caping shall be measured as one unit.
All as per serial item No 227 but 2 runs of 6 Sqmm(one run for phase & one run for neutral) and one run 6 sqmm cable as earth wire.
S&F in repairs, gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 15mm bore dia iron pipe all as specified and as directed.
S&F in repairs, gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 20 mm bore dia iron pipe all as specified and as directed.
Disconnecting water and electrical connection, dismantling the accessories carefully of RO system of capacity 12 Ltrs, cleaning the exposed surface and refixing the same to its original position, connecting up of water/electric connections after repairs and testing all as specified and as directed. Note : (a) Parts to be replaced shall make of existing make of RO. (b) Parts shall be measured and paid separately as supply and fixed in repairs.
S&F in repairs, pre filter for 12 Ltrs capacity RO system complete all as specified and as directed.
S&F in repairs, carbon block filter for 12 Ltrs capacity complete all as specified and as directed.
S&F in repairs, UV for 12 Ltrs capacity RO system complete all as specified and as directed.
S&F in repairs, membrance for 12 Ltrs capacity RO system complete all as specified and as directed.
S&F in repairs, pressure pump for 12 Ltrs capacity RO system complete all as specified and as directed.
Supply and laying 20 mm bore tubing, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trenches /walls or laying in trenches including all fittings complete all as specified and as directed .
Supply and laying 15mm bore tubing, medium grade, galvanised,with all fitting and fixed complete to walls and ceilings or laid in floorsin trenches /walls or laying in trenches including all fittings complete all as specified and as directed .
S&F in replacement MCB DB double door 4 way SPN with suitable rated busbar 240 V complete all as specified and directed .
S&F in replacement of MCB SP, C Curve, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified & as directed.
S&F in replacement of MCB SPN, C Curve, 40-63 Amps 10 KA single pole AC 230 volts complete all as specified & as directed.
Taking down carefully copper/Aluminum point wiring (5 Amp /15 Amp) complete such as switches, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc and matching with existing surface complete all as specified and as directed.
M & L for point wiring for one 3 pin socket outlet, 5 Amps on independent board complete with 1.5 Sqmm single core multistranded copper conductor FRLS ,PVC insluated and unsheathed cable 650/1100 volts grade, confirming to IS-694 1990, drawn through and including PVC casing capping 32mm /25 mm width with all accessories as specified with modular cover plate with frame and modular metal flux boxes ,blank plate for mounting fitting & fixture like switches sockets etc including copper earth contunity wire for PVC insulated of size 1.5 Sqmm for one 5 Amp point controlled by one way switch complete all as specified and as directed.
All as per serial item No.243 above but with 4.0 Sqmm copper conductor cable for socket outlet 15 Amps complete all as specified and directed.
S&F modular switch single pole one way 6/5 Amps 1 module complete all as specified and directed.
S&F modular switch single pole one way 16 Amps 1 module complete all as specified and directed .
S&F modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and directed .
S&F modular socket 6 A/16 Amp -2/3 pin combined 2 module complete all as specified and directed .
SONU ENTERPRISES
BHAVIN INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .