Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.9 LAccepted-AOC AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | ₹9.9 L | 1 | Accepted-AOC The resultant L-1 Bidder |
| Sl No | Description | Qty | Unit | J.N. RAY L1 |
|---|---|---|---|---|
| 1.00 | Maintenance of 11 KV Overhead line of E&M department catering power from 33/11 kv Central substation to 2 X 1 MVA main substation followed by A & C type colony substation CWS(x), Talcher. | 252 | Days | 1,840 ₹4,63,680 Lowest |
| 2.00 | Supply of galvanized stay set for 11KV overheard lines complete with 19/20 mm dia X 1.8 mtr long saty rod, anchor plate of size 45cmX 45cmX7.5mm thick, thimble,stayclamps, turn buckle (20mmX600mm), 7/4.00mm dia G.I. stay wire and 11KV strain insulator etc in cement concrete 1:3:6(1 cement:3coarse sand:6 grade stone aggregate 40mm nominal size)foundation including excavation and refilling etc. as required (13.1) | 16 | Nos | 3,950 ₹63,200 Lowest |
| 3.00 | Supply of three piece non linear resistor type lightining resistor suitable for 3 wire,11KV O/H lines with rated voltage KV (rms) with a nominal discharge current rating 5KA and complete eith galvanised clamping arrngement.G.I bolts ,nuts ,washers etc.as reqd (13.13) | 12 | Nos | 2,500 ₹30,000 Lowest |
| 4.00 | Supply of 33KV pin Insulator complete with large steel head G.I. pin ,nuts,washers etc.as required. MCL SOR E&M Works 2023 -2648) | 40 | Nos | 500 ₹20,000 Lowest |
| 5.00 | Supply of 11KV disc Insulator for 11 kv over head lineswith galvanised insulator fittings, ball & socket type & complete with galvanised strain clamps, bolts, nuts & washers etc.as required. MCL SOR E&M Works 2023 -2646/2647) | 15 | Nos | 720 ₹10,800 Lowest |
| 6.00 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6(1cement:3 coarse sand:6 stone aggregate 40mm nominal size) foundation including excavation & refilling & secured with holding clamps,bolts,nuts,etc.as required. MCL SOR E&M Works 2023 - 11.4 | 16 | Each | 7,100 ₹1,13,600 Lowest |
| 7.00 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complet with all assesories including ferrules suitable for 120 SQmm size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.MCL SOR E&M Works 2023 ,10.6.2) | 5 | Each | 26,700 ₹1,33,500 Lowest |
| 8.00 | Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC | 1 | Nos | 8,347.8 ₹8,347.8 Lowest |
Tender Value
₹11.1 L
EMD Value
₹14,000
Closing Date
6 Apr 2026, 5:00 pmClosed
SO(EnM), CWS(X) Talcher
SO(EnM) office, GM CWS(X), Talcher, MCL
AMC of 11KV HT OHL of CWS, Talcher Catering power from Central Substation Balanda to 2 x 1 MVA Main substation and A and C Type colony substation of CWS Talcher for a period of three years.
2026_MCL_357559_1
GM(CWST)/EnM/e-Tender/25-26/03
Open Tender
AMC WORKS
Item Rate
1096 days
CWS(X), Talcher
As per NIT
4 documents required · 4 mandatory
₹14,000
Yes
8 Jun 2026
26 Mar 2026
8 Apr 2026
27 Mar 2026
6 Apr 2026
27 Mar 2026
27 Mar 2026 - 30 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Maintenance of 11 KV Overhead line of E&M department catering power from 33/11 kv Central substation to 2 X 1 MVA main substation followed by A & C type colony substation CWS(x), Talcher. | - | Days | 2,054.48 | - |
| 2 | Supply of galvanized stay set for 11KV overheard lines complete with 19/20 mm dia X 1.8 mtr long saty rod, anchor plate of size 45cmX 45cmX7.5mm thick, thimble,stayclamps, turn buckle (20mmX600mm), 7/4.00mm dia G.I. stay wire and 11KV strain insulator etc in cement concrete 1:3:6(1 cement:3coarse sand:6 grade stone aggregate 40mm nominal size)foundation including excavation and refilling etc. as required (13.1) | 16 | Nos | 4,430 | ₹70,880 |
| 3 | Supply of three piece non linear resistor type lightining resistor suitable for 3 wire,11KV O/H lines with rated voltage KV (rms) with a nominal discharge current rating 5KA and complete eith galvanised clamping arrngement.G.I bolts ,nuts ,washers etc.as reqd (13.13) | 12 | Nos | 2,805 | ₹33,660 |
| 4 | Supply of 33KV pin Insulator complete with large steel head G.I. pin ,nuts,washers etc.as required. MCL SOR E&M Works 2023 -2648) | 40 | Nos | 664 | ₹26,560 |
| 5 | Supply of 11KV disc Insulator for 11 kv over head lineswith galvanised insulator fittings, ball & socket type & complete with galvanised strain clamps, bolts, nuts & washers etc.as required. MCL SOR E&M Works 2023 -2646/2647) | 15 | Nos | 810 | ₹12,150 |
| 6 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6(1cement:3 coarse sand:6 stone aggregate 40mm nominal size) foundation including excavation & refilling & secured with holding clamps,bolts,nuts,etc.as required. MCL SOR E&M Works 2023 - 11.4 | 16 | Each | 7,943 | ₹1,27,088 |
| 7 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complet with all assesories including ferrules suitable for 120 SQmm size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.MCL SOR E&M Works 2023 ,10.6.2) | 5 | Each | 29,679 | ₹1,48,395 |
| 8Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_370420.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tendernotice_2.pdf
PDF • 1.65 MB
BOQ_370420.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .