Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.9 LAccepted-AOC | 1 | Accepted-AOC Reasonable | |
| 2 | 2₹28.3 L+₹67,329.15 (2.44%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | 2 | Rejected-Finance High Rate | |
| 3 | 3₹29.1 L+₹1.5 L (5.49%)Rejected-Finance | 3 | Rejected-Finance High Rate | |
| 4 | 4₹32.9 L+₹5.3 L (19.3%)Rejected-Finance 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | 4 | Rejected-Finance High Rate | |
| 5 | 5₹34.5 L+₹6.9 L (24.9%)Rejected-Finance | 5 | Rejected-Finance High Rate |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
13 Jun 2020, 6:00 pmClosed
GE NDA KHADKWASLA
GE NDA KHADKWASLA
REPAIR AND MAINT OF LT PANELS AND FEEDER PILLARS AT VARIOUS PLACES AT NDA KHADAKWASLA
2020_MES_345658_1
GE (K) 06 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE NDA KHADKWASLA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADKWASLA
₹74,000
Yes
21 Jul 2020
18 May 2020
15 Jun 2020
19 May 2020
13 Jun 2020
29 May 2020
20 May 2020 - 28 May 2020
Amount
Disconnecting existing incoming and outgoing cables from existing old / unsv LT FP/Panel after taking proper power shut down and exercising all safety precautions for human safety, removing the old / unsv LT FP / Panel complete with its accessories and setting aside at safe place for further disposal including necessary earthwork & PCC demolition complete all as specified and directed.
S & F against Item No. 1 above in replacement outer shell of LT Feeder Pillar Panel of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL 7035 (Siemens Gray) shade with matt finish including doors, hinges and fabrication, cutting, welding, supports, clamps, cable glands etc complete all as specified and directed. Note : (a) Fixing of its accessories against item No. 1 i.e. MCCBs, Busbars, Indicators, control wiring etc shall be measured and paid separately. (b) Size and design of item shall be executed as per site requirement and also approved by Engr-in-Charge.
S & F against Item No. 1 above in replacement outer shell / Inner shell of LT Feeder Pillar Panel of 2 mm thick CRCA sheet with epoxy powder coating of RAL 7035 (Siemens Gray) shade with matt finish including cutting, welding, supports, clamps, cable glands etc complete all as specified and directed. Note : (a) Fixing of its accessories against item No. 1 i.e. MCCBs, Busbars, Indicators, control wiring etc shall be measured and paid separately. (b) Size and design of item shall be executed as per site requirement and also approved by Engr-in-Charge.
S & F against Item No. 1 above in replacement angle Iron Support of required size duly painted with anti corrosive black paint including welding, cutting, nuts, bolts & washers of suitable size including taking down old existing one complete all as specified and directed.
S & F in replacement neoprane rubber gaskets of LT Feeder Piller/Panel of suitable size complete all as specified and directed.
S & F in replacement aluminium busbrs electrolytic grade, Current rating and KA rating as per site requirement and interconnected links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. The size and thickness of busbars shall be as per sample including drilling, cutting and suitable size of galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement control wiring of 1.5 Sqmm single core stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement busbar panel weather proof outdoor type single door, CPRI approved fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, shall not be less than 400mmX50mmX10mm( L x W x thickness) electrolytic grade of adequate rating including required size of nut bolts for fixing of cables upto 240 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of cable glands, thimbles etc. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each .6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. Including taking down existing one with its cable connection and providing cable glands, Lugs for cable, 4 Nos cable entry holes. The overall size of the Busbar panel shall not be less than 500mmx300mmx700mm (LxWxH) including earthwork all as directed and specified by Engr in Chrage. Note : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 400 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts etc
S & F in replacement busbar panel weather proof outdoor type single door, CPRI approved fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, 300mmX40mmX 10mm (thickness) electrolytic grade of adequate rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of incoming and outgoing cable glands, thimbles. All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 30mmx30mmx5mm thick angle iron supports of not less than each .6mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at uitable depth as per site requirement including taking down existing one with its cable connection and providing cable glands, Lugs for cable, 4 Nos cable entry holes. The overall size of the Busbar panel shall not be less than 400mmx200mmx550mm (LxDxH).including earthwork all as directed and specified by Engr in Chrage. Note : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 185 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts, Lugs etc
S & F in replacement busbar panel weather proof outdoor type single door, CPRI approved fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, 200mmX40mmX8mm (thickness) electrolytic grade of adequate rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment and provision of incoming and outgoing cable glands, thimbles All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The panel shall be provided with 04 Nos 25mmx25mmx5mm thick angle iron supports of not less than each .6mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at uitable depth as per site requirement including taking down existing one with its cable connection and providing cable glands, Lugs for cable, 4 Nos cable entry holes. The overall size of the Busbar panel shall not be less than 300mmx200mmx500mm (LxDxH).including earthwork all as directed and specified by Engr in Chrage. Note : (i) 4 Nos of Entry holes for cables from bottom side shall be provided upto 95 Sqmm and each busbar shall be provided neccessary arrangement to connect 4 Nos of cables including Nut bolts etc
S & F in replacement control wiring of 2.5 Sqmm single core stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply, Installation & testing Digital Multifunction Meter 4410 Series LED, Accuracy Class 1, with RS 485 Parameters V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On Hours, Phase angle, Interrupts,THD, Events (High-Low), Neutral Current including suitable size of CTs including cutting of required size of panel without disturbing other accessories and taking down old unsv meters etc complete all as specified and directed at site.
S & F in replacement MCCB 3 Pole, 415 Volts, 630 Amp, 50 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 3 Pole, 415 Volts, 400 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 3 Pole, 415 Volts, 320-350 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 3 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 3 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 3 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 4 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 3 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 3 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 4 Pole, 415 Volts, 40 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement MCCB 4 Pole, 415 Volts, 25 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make : L&T/Legrand/C&S
S & F in replacement LED Indicator lamp Red/Yellow/Blue size as per site requirement including suitable size of nuts, bolts including drilling and cutting in panel without disturbing other existing fitments complete all as specified and directed at site.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, CPRI approved fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of adequate rating or specified below. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1200mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for required No of Cable with suitable size of Cable Glands including 2 Nos of Earting Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. Make : L&T/Legrand/C&S (b) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. Make : L&T/Legrand/C&S (c) MCCB 4 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. Make : L&T/Legrand/C&S (d) MCB Double Pole, 240 Volts, 40 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 03 Nos. Make : L&T/Legrand/C&S (e) LED type phase indicator lamp RYB, ON, OFF & TRIP. f) 4 Nos bus bars of high conductivity aluminium alloy for phase (R,Y,B,N) suitable for 400 Amp rating.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, CPRI approved fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of adequate rating or specified below. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1200mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for required No of Cable with suitable size of Cable Glands including 2 Nos of Earting Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 100 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. Make : L&T/Legrand/C&S (b) MCCB 4 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 No. Make : L&T/Legrand/C&S (c) MCB Double Pole, 240 Volts, 40 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 03 Nos. Make : L&T/Legrand/C&S (d) LED type phase indicator lamp RYB, ON, OFF & TRIP. (e) 4 Nos bus bars of high conductivity aluminium alloy for phase (R,Y,B,N) suitable for 400 Amp rating. (b) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. Make : L&T/Legrand/C&S
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, CPRI approved fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of adequate rating or specified below. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for required No of Cable with suitable size of Cable Glands including 2 Nos of Earting Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. Make : L&T/Legrand/C&S (c) MCCB 4 Pole, 415 Volts, 100 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 No. Make : L&T/Legrand/C&S (d) MCCB 4 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. Make : L&T/Legrand/C&S (e) MCB Double Pole, 240 Volts, 40 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 02 Nos. Make : L&T/Legrand/C&S (f) LED type phase indicator lamp RYB, ON, OFF & TRIP. (g) 4 Nos bus bars of high conductivity aluminium alloy for phase (R,Y,B,N) suitable for 400 Amp rating.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, CPRI approved fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of adequate rating or specified below. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for required No of Cable with suitable size of Cable Glands including 2 Nos of Earting Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. Make : L&T/Legrand/C&S(a) MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. Make : L&T/Legrand/C&S (b) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. Make : L&T/Legrand/C&S (c) MCCB 4 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 03 No. Make : L&T/Legrand/C&S (d) MCB Double Pole, 240 Volts, 40 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 02 Nos. Make : L&T/Legrand/C&S (f) 4 Nos bus bars of high conductivity aluminium alloy for phase (R,Y,B,N) suitable for 400 Amp rating. (e) LED type phase indicator lamp RYB, ON, OFF & TRIP.
S & F commissoining and installation in replacement MCCB 4P 250 amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu including taking down of existing one suitable size of spreader links with galvanised or codmium plated high tensile nuts, bolts and washers etc all as specified and directed. Make: L&T/Legrand/C&S.
S & F commissoining and installation in replacement MCCB 4P 200 amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu including taking down of existing one suitable size of spreader links with galvanised or codmium plated high tensile nuts, bolts and washers etc all as specified and directed. Make: L&T/Legrand/C&S.
S & F commissoining and installation in replacement MCCB 4P 160 amps, 25 KA breaking capacity with adjustable thermal and magnetic release with Ics=100% of Icu including taking down of existing one suitable size of spreader links with galvanised or codmium plated high tensile nuts, bolts and washers etc all as specified and directed. Make: L&T/Legrand/C&S.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to machinery/equipment for transformer, LT Panel, Feeder Pillars, Sub Feeder Pillars etc. as required with 40mm GI Light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC (1:2:4) type B1 & pit cover 75mm thick in PCC (1:2:4) type B1 including with lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed by Engineer-in-Charge including testing on completion.
S & F manual change over LT Panel weather proof outdoor type double door, CPRI approved fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side single door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with spreader links/busbars extension of adequate rating including incoming and outgoing cable connection, glands, thimbles, all joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators. The panel shall be provided with RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . The overall size of the Change Over Panel shall not less than 500mmX400mmX500mm (LxBxH) including One No. of Manual ON Load Change Over Switch of rating 315 Amp, 415Volts, 50 Hz, AC, Four Pole with staggered terminals including both side of spreder links (conforms to IEC 60947-3). The panel shall be provided for Cable entry upto size of 400 Sqmm cable from bottom side for required No of Cable with suitable size of Cable Glands including 2 Nos of Earting Terminals one on each side of the Panel with GI earth strip. Note : Before manufacturing drawing and design of panel shall be approved by Engr-in-charge.
S & F manual change over LT Panel weather proof outdoor type double door, CPRI approved fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side single door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with spreader links/busbars extension of adequate rating including incoming and outgoing cable connection, glands, thimbles, all joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators. The panel shall be provided with RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1 mt height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . The overall size of the Change Over Panel shall not less than 500mmX400mmX500mm (LxBxH) including One No. of Manual ON Load Change Over Switch of rating 200 Amp, 415Volts, 50 Hz, AC, Four Pole with staggered terminals including both side of spreder links (conforms to IEC 60947-3). The panel shall be provided for Cable entry upto size of 400 Sqmm cable from bottom side for required No of Cable with suitable size of Cable Glands including 2 Nos of Earting Terminals one on each side of the Panel with GI earth strip. Note : Before manufacturing drawing and design of panel shall be approved by Engr-in-charge.
S & F in replacement On load change over switch Four Pole with advance Neutral 200 Amps current rating, 415 Volts, 50 Hz AC open execution conforming to IEC 60947-3 including suitable size of spreader links on both side with galvanised or cadmium plated high tensile nuts, bolts and washers etc and also suitable for wall/surface mounting arrangement complete all as specified and directed. Make - L&T/Legrand/C&S
S & F in replacement on load change over switch four pole with advance Neutral 250 Amps current rating, 415 Volts, 50 Hz AC open execution conforming to IEC 60947-3 including suitable size of spreader links on both side with galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make - L&T/Legrand/Schneider
S & F in replacement on load change over switch four pole with advance Neutral 400 Amps current rating, 415 Volts, 50 Hz AC open execution conforming to IEC 60947-3 including suitable size of spreader links on both side with galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed. Make - L&T/Legrand/Schneider
M & L for welding to existing feeder pillar panels of CRCA sheet in repairs upto 10 cm in length including taking down, cleaning, preparing the surfaces and refixing in position including painting to match with existing colour complete all as specified and directed.
M & L for cutting/drilling to CRCA Sheet of 3.15mm/2mm thick for fixing of locks, MCCB etc of suitable length/size complete all as specified and directed.
S & F cylindrical panel locks of suitable size/as per sample complete all as specified and directed.
S & F in replacement of old broken cold rolled mild steel Hinges to existing Feeder Pillar box of suitable size or as per sample including welding and painting to match with existing colour etc complete all as specified and directed.
M & L for preparation of existing surface of Feeder Pillar /Panel and Supporting angle iron of feeder pillar panel by srapping down, peeled off old paint, cleaning etc and priming with Red oxide and applying two coat of Smoke Gray paint and applying two coat of black paint to supporting angle iron of Feeder Pillar /Panel including cleaning of Panels from inside by blowing of air etc complete all as specified and directed.
M & L for demolition of unreinforced PCC, floors etc in any position and any description including removal of demolished material complete all as specified and directed.
M & L for plain concrete cement (1:2:4) type B2 using 40mm graded coarse aggregate for foundation of Feeder Panels etc including necessary form work complete all as specified and directed.
S & F Cable Jointing Kit for 1.1 KV grade Cable for straight through joint complete with jointing material heat shirnk type and accessories suitable for XLPE insulated, armoured, AL conductor cable of following size :- (Make- Raychem/Denson /Mseal/3M) 3.5 Core 400 Sqmm
Ditto all as per item No 45 above but 3.5 Core 240-300 Sqmm
Ditto all as per item No 45 above but 3.5 Core 150-185 Sqmm
Ditto all as per item No 45 above but 3.5 Core 70-120 Sqmm
Ditto all as per item No 45 above but 3.5 Core 25-50 Sqmm
Ditto all as per item No 45 above but 4 Core 10 - 16 Sqmm
Supply and Laying in replacement including testing & commissioning of LT UG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:- Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item. 3.5 Core 400 Sqmm
Ditto all as per item No 51 above but 3.5 Core 300 Sqmm
Ditto all as per item No 51 above but 3.5 Core 240 Sqmm
Ditto all as per item No 51 above but 3.5 Core 185 Sqmm
Ditto all as per item No 51 above but 3.5 Core 150 Sqmm
Ditto all as per item No 51 above but 3.5 Core 120 Sqmm
Ditto all as per item No 51 above but 3.5 Core 95 Sqmm
Ditto all as per item No 51 above but 3.5 Core 70 Sqmm
Ditto all as per item No 51 above but 3.5 Core 50 Sqmm
Ditto all as per item No 51 above but 3.5 Core 35 Sqmm
Ditto all as per item No 51 above but 3.5 Core 25 Sqmm
Ditto all as per item No 51 above but 4 Core 16 Sqmm
Ditto all as per item No 51 above but 4 Core 10 Sqmm
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out in for foundation of pole, stay, laying of cable and pipe etc : Hard/Dense soil
Ditto all as per item No. 64 above but Soft/disintegrated rocks
Returning and filling, including spreading and well ramming in layers n exc 25 cm all as specified and directed.
Removing excavated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point.
M&L for dry sand cushioing to under ground cable intrenches incl spreading, leveling and hand punning complete all specified. Note : For measurement purpose punned thickness shall be considered.
Supply and laying common burnt clay building sub class B old size bricks, laid in right angle along the cable for protection of cable, complete all as specified
S & F in replacement Cable glands double compression heavy duty brass cable glands nickle plated complete all as specified and directed of following sizes :- (Make : Dowell's/3M) 3.5 Core 400 Sqmm
Ditto all as per item No. 70 above but 3.5 Core 240 to 300 Sqmm
Ditto all as per item No. 70 above but 3.5 Core 150 to 185 Sqmm
Ditto all as per item No. 70 above but 3.5 Core 95 to 120 Sqmm
Ditto all as per item No. 70 above but 3.5 Core 50 to 70 Sqmm
Ditto all as per item No. 70 above but 3.5/4 Core 25 to 35 Sqmm
Ditto all as per item No. 70 above but 4 Core 10 to 16 Sqmm
M & L for tubes, light Grade, galvanised with all fittings, laid in trenches or with pole for protection etc of following sizes including taking down existing one complete all as specified and directed by Engineer-in-Charge of following size :- 50mm
Ditto all as per item No. 77 above but 80mm
S & F in replacement of 1100 Volts grade heavy duty cable PVC insulated aluminium 6 Sqmm Stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension GI wire, one twin core cable flat or circular including taking down existing one complete all as specified and directed.
S & F in replacement of PVC insulated 70 Sqmm FRLS single core bright annealed bare copper conductor heavy duty unsheathed multistranded cable 650/1100 Volts grade with required size of copper lugs including taking down existing one complete all as specified and directed.
S & F in replacement of PVC insulated 95 Sqmm FRLS single core bright annealed bare copper conductor heavy duty unsheathed multistranded cable 650/1100 Volts grade with required size of copper lugs including taking down existing one complete all as specified and directed.
S & F in replacement Manual Draw Out (MDO) type, ACB 630 Amp, 4 Pole, 415 Volts as per IEC 60947/IS 13943 Part-1&2 with UV release microprocessor based protection unit with flexible and adjustable current time protection setting for overload short circuit, instantaneous short circuit and Earth Fault protection, step wise protection. Protection unit should have LCD display with battery backup, inbuilt LED indication and alarm for temp rise. ACB shall be with Ics=Icu=Icw and including test certificate for ACB. Rates also include for fixing to LT Panel and taking down existing one including necessary busbar arrangement complete all as specified and directed. Make : Legrand/L&T/ABB
S & F in replacement Manual Draw Out (MDO) type, ACB 800 Amp, 4 Pole, 415 Volts as per IEC 60947/IS 13943 Part-1&2 with UV release microprocessor based protection unit with flexible and adjustable current time protection setting for overload short circuit, instantaneous short circuit and Earth Fault protection, step wise protection. Protection unit should have LCD display with battery backup, inbuilt LED indication and alarm for temp rise. ACB shall be with Ics=Icu=Icw and including test certificate for ACB. Rates also include for fixing to LT Panel and taking down existing one including necessary busbar arrangement complete all as specified and directed. Make : Legrand/L&T/ABB
S & F in replacement Manual Draw Out (MDO) type, ACB 1000 Amp, 4 Pole, 415 Volts as per IEC 60947/IS 13943 Part-1&2 with UV release microprocessor based protection unit with flexible and adjustable current time protection setting for overload short circuit, instantaneous short circuit and Earth Fault protection, step wise protection. Protection unit should have LCD display with battery backup, inbuilt LED indication and alarm for temp rise. ACB shall be with Ics=Icu=Icw and including test certificate for ACB. Rates also include for fixing to LT Panel and taking down existing one including necessary busbar arrangement complete all as specified and directed. Make : Legrand/L&T/ABB
S & F in replacement Aluminium Tube terminals of following sizes complete all as specified and directed :- 10 Sqmm -6/8
Ditto all as per item No. 85 above but 16 Sqmm -8/10
Ditto all as per item No. 85 above but 25 Sqmm -8/10/12
Ditto all as per item No. 85 above but 35 Sqmm -8/10/12
Ditto all as per item No. 85 above but 50 Sqmm -8/10/12
Ditto all as per item No. 85 above but 70 Sqmm -8/10/12
Ditto all as per item No. 85 above but 95 Sqmm -10/12/16
Ditto all as per item No. 85 above but 120 Sqmm -10/12/16
Ditto all as per item No. 85 above but 150 Sqmm -10/12/16
Ditto all as per item No. 85 above but 185 Sqmm -10/12/16
Ditto all as per item No. 85 above but 240 Sqmm -12/16
Ditto all as per item No. 85 above but 300 Sqmm -16/20
Ditto all as per item No. 85 above but 400 Sqmm -20
S & F galvanised or cadmium plated high tensile mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed the both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 5cm long and 5 to 10mm dia of neck complete.
Ditto as per item No. 98 above but n.exc 11 to 15mm dia of neck.
Ditto as per item No. 98 above but n.exc 16 to 20mm dia of neck.
M & L in replacement for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 25 x 4mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to machinery/equipment for transformer, LT Panel, Feeder Pillars, Sub Feeder Pillars etc. as required with 40mm GI Light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 including with lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
S & F in replacement HRC Fuse link DIN/Cylindrical type including suitable size of fuse base and drilling, cutting, screws etc complete all as specified and directed of following current rating capacity :- (Make : L&T/Havells/C&S) 80 Amp
Ditto all as per item No. 102 above but 100 Amp
Ditto all as per item No. 102 above but 125 Amp
Ditto all as per item No. 102 above but 160 Amp
Ditto all as per item No. 102 above but 200 Amp
Ditto all as per item No. 102 above but 250 Amp
Ditto all as per item No. 102 above but 315 Amp
Ditto all as per item No. 102 above but 400 Amp
Ditto all as per item No. 102 above but 500 Amp
Ditto all as per item No. 102 above but 630 Amp
S & F in replacement Operating handle kit for On load manual change over switch four pole of capacity 400 Amps current rating as per sample complete all as specified and directed. Make - L&T/Havells/C&S
S & F in replacement Operating handle kit for On load manual change over switch four pole of capacity 250 Amps current rating as per sample complete all as specified and directed. Make - L&T/Havells/C&S
S & F in replacement of MCB 4 Pole, 415 Volts, 50 Hz, 40-63 Amp, 10 KA, C Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed. Make : L&T/Legrand/Schneider
S & F in replacement of MCB 2 Pole, 415 Volts, 50 Hz, 40-63 Amp, 10 KA, C Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed. Make : L&T/Legrand/Schneider
S & F in replacement of MCB Single Pole, 415 Volts, 50 Hz, 40-63 Amp, 10 KA, C Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed. Make : L&T/Legrand/Schneider
S & F in replacement of 4 Way TPN DB-VTPN 160 Amp MCCB DB's, as per IEC 61439-3, suitable for flush mounting and surface mounting with 250 amp copper busbar for each phase, 2 neutrals bar, 2 earth busbar and cable ties for cable management, fully insulated busbar & shrouded neutral bars, improved Pan assembly for ease of installation, prefitted masking sheet, reversible door for IP-30 with provision for 160 Amp MCCB as incomer and SP MCB's as outgoing including taking down existing one with all its incoming and outgoing cables complete all as specified and directed. Make : Legrand/L&T/Schneider
S & F in replacement of 4 Module Plexo boxes conform to EN 60439-3, wheather proof cabinets IP 65, IK-09-Cl-II, door and cabinet fully reversible, removable chasis and faceplates from 2-row versions up, position rail for modular products and moulded cases, spacing between rail 150 mm box colour light grey L750A, cover colour dark grey R746A including taking down existing one with all its incoming and outgoing cables complete all as specified and directed. Make : Legrand/L&T/Schneider
S & F in replacement Switch disconnector fuse units 125 Amp TPN suitable to 63 to 125 Amp HRC fuse link cylindrical / DIN type fuse link including taking down existing one complete all as specified and directed. Make : Havells/Legrand/C&S. Note : HRC fuses shall be measured and paid separately.
S & F in replacement Switch disconnector fuse units 32 Amp TPN suitable to 32 Amp HRC fuse link cylindrical / DIN type fuse link including taking down existing one complete all as specified and directed. Make : Havells/Legrand/C&S. Note : HRC fuses shall be measured and paid separately.
S & F in replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size 200 x 150 mm for LT Supply including taking down existing one complete all as specified and directed.
S & F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situationfor loop earthing etc. Size 32 x 6 mm GI strip.
M&L for Shifting/Installation of LT Panel/ Feeder Pillar from existing place to directed place including fixing of accessories incoming/outgoing cables, necessary earthwork & PCC (1:3:6) as per site requirement for grouting LT Panel /Feeder Pillar at suitable depth complete all as specified and directed.
M&L for disconnecting existing incoming and outgoing cables from existing old / unsv V-TPN DB's after taking proper power shut down and exercising all safety precautions for human safety, removing the old / unsv V-TPN DB's complete with its accessories and setting aside at safe place for further disposal including fixing arrangement on wall complete all as specified and directed.
M&L for Road/PCC Cutting as required for laying pipe/cable etc including earthwork and necessary excavation including making good with required material to match with the existing one or with PCC (1:2:4) type B1 complete all as specified and as directed at site.
KESARI AND SONS
SONU ENTERPRISES
R. K. Industrial Fabricators
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
CHAITANYA WINDWELL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .