Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹72.1 L+₹6.2 L (9.44%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹73.6 L+₹7.7 L (11.6%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | Rejected-Technical | - | Rejected-Technical No Remark in WLR | |
| 5 | Rejected-Technical 602 6TH FLOOR BNG HOUSE D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | - | Rejected-Technical GST Certificate found not uploaded |
Tender Value
₹67 L
EMD Value
₹1.3 L
Closing Date
6 Oct 2021, 6:00 pmClosed
GE(NW) BAHDNUP
GE(NW) BAHDNUP, MUMBAI
SPECIAL REPAIRS TO BLDG NO NS 112 ATGHATKOPAR UNDER GE(NW) BHANDUP
2021_MES_455810_3
8134/B
Open Tender
Civil Works
Item Rate
270 days
GHATKOPAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE(NW) BHANDUP
₹1.3 L
Yes
4 Apr 2022
11 Sept 2021
7 Oct 2021
11 Sept 2021
6 Oct 2021
18 Sept 2021
Amount
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Demolition of reinforced cement concrete shelves,chajjas and suspened similar work and removal of rubbish demolished materials of MD land complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in kitchen platform and similar work laid, bedded and pointed in cement mortar and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Demolition of cement concrete ( reinforced) as in roofs, floors ( other than ground floors), beams, staircase, landing, chajjas , parapet, water tank and similar suspended work etc. and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each complete as directed
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete as directed
Resecuring or easing and adjusting, without taking down shutters of any description exc 1 sqm each but not exceeding 2 Sqm each complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed. Note: Water proofing compound will be measured & paid seperately.
M&L for 10 mm thick cement plaster in CM (1:3) using water proofing compound @ 3% by weight of cement complete all as specified and directed BY Engr-in-charge ( Note : water proofing compound will be measured and paid seperately)
Supply and Application of 5 Layer SHR Waterproofing Coating System on leaking concrete surface by thorough surface preparation followed by one absorption coat of Thermacool WP 51, nano-tech modified, UV resistant elastomeric clear coat having min. 50% solids, then overcoating with 2 Coats of Thermacool WP51+Cement mixture as waterproofing coat having +450% Elongation, Tensile Strength min. 2.2 MPa and then top-coated with 2 Coats of Thermacool 0.3 C pure acrylic based , UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) Solar IR Heat Reflective coating conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 sqm/Ltr/2 coat, DFT 100-120 microns using brush, roller, airless spray gun as applicable. The product should have been tested at IIT or NABL Approved Lab and application is to be done by Thermacool approved applicator only.
M&L for 20mm thick screed bed in CM 1:4 mixed with 80ml per kg of cement or as per manufacturer's instructions of polymeric liquid water proofing additive over Non woven Geo textile layer to ensure no puncture of roof treatment surfaces etc as specified and directed by Engineer-in-Charge. (Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately)
Supply only polymer based lilquid water proofing compound.
M&L for making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
M&L for 75 mm thick cement concrete type C-2,1:3:6 (40 mm graded aggregate) as in plinth protection finishes and fair without using extra cement including forming 12 mm thick expansion joint filled with sealing compound Grade 'A' etc complete all as specified and directed.
M&L providing cement concrete type B0, 1:2:4 (12.5mm graded aggregate) 25 mm thick as in flooring finshes the surfaces even and fair without using extra cement complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surface etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for 20 to 25mm machine cut pre polished kota stone slab for steps in single piece with round nosing with three numbers of serration as in treads of steps for staircase laid over cement screed bed and jointed with grey cement slurry mixed with pigment to match the shade of of the slab including rubbing and including over 20mm thick screed bed or bedding layer in CM1:4 complete all as specified and as directed.
M&L for 20 to 25mm machine cut pre polished kota stone slab as in riser of steps, skirting, window cills,dado and pillar in single piece, laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 15 mm thick Rendering in CM1:4 complete all as specified and as directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortor 1:6 complete all as specified & directed.
M&L for brick work with sub-class 'B' bricks, straight, or curved on plan to any radius as in half brick thick wall in CM 1:4 complete all as specified and directed.
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth with sagol finish complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth with sagol finish complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately
Supply only integral water proofing compound.
M&L for Preparation of New Plastered surfaces of wall and applying two coats of rain coat over( of Shade/colour as directed by E-in-C) one coat of seal primer all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed by Engr- in charge
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of putty for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper including application of white cement based wall care putty finish for smooth finish.etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of ceiling brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying two coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparing new or previously untreated wood and wood based surface of any description, over 10cm in width or girth, not other wise described and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for for preparation of old wooden surfaces of any description or not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and directed.
S&F aluminium section in doors/windows/ventilators ,any type, powder coated in approved colour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series 'B') or section as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber beading or gasket for aluminium sections for fixing glass/XPM jali and all necessary fittings complete, screws, plugs for fixing screws, etc all as specified and directed (Make : JINDAL/HINDALCO) Notes : (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of bakelite sheet glass pane,wire mesh and rubber beading or gasket will be measured separately.
S&F only 4mm thick figured glass/pin headed type ordinary quality fixed in aluminium ventilator n exc 0.50 Sqm each pane all as specified & as directed by EIC.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
Supply only for 6mm thick bakelite sheet prelaminated both side with decorative choice laminations with aluminium frame cuboard shutter work complete all as specified and directed.
S&F aluminum anodised grill DG- 202 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
S&F II nd class Hard Wood as in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc all as specified
S& F 35mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze, etc ( with sash bars), edges of framing plain, chamfered or rounded , fitted with cut and mitered beads for securing glass, etc size of members of shutters as specified & directed in SSR Part-I , section 8, clause 8.20 (a) complete all as specified and directed.
S& F 2nd class HW 35 mm thick,plain, framed, panelled shutters (any numbers of panels), with pannels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face neneers;fixed to chowkats complete all as specified & directed.
S&F Solid PVC door frame (Chowkhat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
S&F for Factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottam rails. MS frame shall be covered with heat moulded plain colour PVC 'Ç'channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rails and bottam rail on either side and as gap insertfor top rail and bottam rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in frame at site complete all as specified and as directed.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed tinned tacks or aluminium wire staples,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
S&F bands, steps, supports or stays for rain water, hooks (stay) heavy for large gates, hook and pintle hinges clamps, hold fasts wall ties, hooks for hanging james and similar small articles Fe-410-0 or Fe-310-0 complete all as specifed and directed.
M&L for PCC 1:2:4 Type B1 using 20 mm graded aggregate as in hold fast, coping ,cills ,steps, seismic and other similar bands, plinth course, string course, parapets, railing, bed plates, kerbs and the like including weathering,slightly rounded or chamfered angles and throating as directed.
M&L for 12mm veneered decorative plywood, grade 1 (with BWR resin), pre-laminated one side with decorative veneer choice lamination and other side white lamination fixed with screw to timber frame as in cuboards&pelmet boxes including 6mm thick teak wood lipping,complete all as specified and directed
S&F for 20mm dia curtain rods anodised aluminium alloy, power coated with fixing brackets, stops, rollers etc complete all as specified and directed
S&F butt hinges 125mm long medium weight, mild steel.
S&F 100 mm stainless steel butt hinges,complete all as specified and directed
S&F 150mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S&F Aluminium anodised barrel tower bolt all as above but 100mm long
S&F 150 mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed
All as per item no.59 above but 100mm long.
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or any pattern) including all fittings heads, shoes, bends swan necks etc including cleaning or refixing removal to stores.
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F Cast iron work grade FG 150, unmachined in bracket, gully traps, grating, railing,frames,manhole covers,fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles all as specified and directed.
Dismantling cast iron of any description etc complete all as specified and directed
S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single (single T ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F PVC floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F PVC floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
Demolition of concrete of any description (un re-inforced) in any position not otherwise described and provided etc
M&L for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed
S&F GI tube heavy grade of 40 mm bore with all fittings and fixed complete to walls and ceilings or laid in floors or sunken portion etc complete all as specified and directed including taking down old one complete all as specified and directed.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F CP concealed stop cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S&F in repairs chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.
S&F in repair CP Tubular towel rail with hook 20 mm dia 600mm long between flanges of fixed with and including chromium plated brass screws and wooden/plastic screws. complete all as specified and directed.
S&F Soap dish, Stainless steel fancy type approx size 160x160x90mm complete all as specified and directed.
S&F stainless steel plate rack steel grade SS 304 of thickness 0.63mm of standard size weight not less than 5 .50kg complete all as specified and directed.
S&F stainles steel sink with drainage board , 1 mm thick for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm including supply and fixing bib tap CP with long body screwed for iron pipe complete all as specified and directed.
S&F in repair low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc. Complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
S&F 15mm bore U-PVC pipes of pressure rating 10kg/cm 2 fixed complete to walls, ceiling or in floor etc. with all fittings complete all as specified and directed.
S&F 20mm bore U-PVC pipes of pressure rating 10kg/cm 2 fixed complete to walls, ceiling or in floor etc. with all fittings complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 40 mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
S&F 2000 ltrs Rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I and fixing of Ball valve of size 15mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor' on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for providing Polymer Bonding Agent as approved by the GE followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 40mm in thikness) with prebatched, prepacked, single component ready to use microconcrete , as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
M&L for building up the profile of structural members using polymer modified mortar while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar , exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
Taking down loose material by chiselling, chipping from beam , stair, column, railing, pardi walls, ceilling etc cleaning the surfaces and guniting in CM 1:3, 30mm thick including use and waste form work and providing welded wire mesh size 100 x 100 mm of wire 3, finishing the guniting surfaces in cement mortar 1:3, and rendering10mm with water proofing compound 2% by weight of cement and finishing even and fair / smooth as reqd without using extra cement to match the existing all as specified and directed.
M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/ chajjas , fixed with self tapping screws complete all as specified and directed.
S&F Mild steel work of Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, mild steel frame work for bird proofing fixing of XPM jalli, (Beam, Angle, Channel, Plates or flat section etc), distance pieces, cleats, bracing, etc, of grade E-250, Fe-410W, quality 'B' including welding, complete all as specified and directed.
M&L for post construction anti- termite traetment along the external wall below concreate or masonary apron using chemical emulsion @2.25 liters per linear meter including drilling and plugging holes with cement morter 1:2 to match the existng floor etc complete all as specified and directed.
M&L for post construction anti- termite of soil / concreate under existing floor along the floor and wall junction using chemical emulsion @ 1 liters per hole 300 mm apart including drilling and plugging 12 mm dia holes with cement morter 1:2 to match the existing floor etc complete all as specified and directed.
M & L for post construction anti - termit treatment at points of contract of wwod work using chemical emulision (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc Complete. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per Manufacture's instructions. Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath.
Taking down carefully unserviceable point wiring of any type & pattern (Light/Fan/Socket or power) including unserviceable fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc complete all as specified and directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed.
M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC conduit (minimum 20mm dia) concealed in wall etc (also including cutting chiseling in wall and making good the same in CM 1:3 to match with the adjoining surfaces) with all accessories, fittings, PVC junction boxes etc, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete all as specified and directed. Note: Modular flush box and inner/outer plates measured and paid separately.
All as per Srl item No 117 above but for call bell point.
All as per Srl item No 117 above but for One 2pin/3 pin socket outlet 5 Amps on independent board.
All as per Srl item No 117 but for One 2pin/3 pin socket outlet 5 Amps on same board with other switches , complete all as specified and directed.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza) Note: Modular flush box and inner/outer plates measured and paid separately.
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for ceiling rose three terminals AC 240 volts 50Hz complete all as specified.
Supply and fixing bell ding dong 240 volt Ac 50Hz complete all as specified and directed.
Supply and fixing modular ceiling fan regulator 120 watt 2 module complete all as specified and directed.
M&L for switch modular one way 6/5 amps 1 module complete all as specified.
M&L for switch modular one way 16/20 amps 1 module complete all as specified.
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L modular bell push 6Amp 1 module complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and 200 Amp bus bar complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA,B Curve rating complete all as specified and directed.
Supply and fixing modular metal flush box 1/2 module complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 4 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 1/2 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 4 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 8 module complete all as specified and directed.
S&F in repairs tube light fitting LED 20 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Material and Labour for tube light fitting LED 10 watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of led ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Supply and fix in repairs highly efficient high power 35 W LED street light fitting with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP66 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting.
Taking down existing ceiling fans and re-fixing the same ceiling fan and exhaust fan any sweep including provisioning of cable from celing rose toc/ fan and spry painting of ceiling fan/Exhaust fan with two coats of synthetic enemal paint complete all as specified and directed.
M & L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron upto test point and protected by GI pipe light grade 40 mm bore up to 7.5 Mtr connected to a main switch board or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover, PCC 1:3:6 type C2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in Electrical Plate No3 of MES Schedule Part – I of 2009.
Supply and fix in repairs wall mounteded meter box of size 1m x 1.5m x 0.3m made out of 2mm thick SS sheet, , for fixing MCCB four way as incoming with aluminium bus bar 200 Amp - 01 No and fixing only energy meter electronic type single phase AC 230 Volts 5 to 30 Amps - 11 Nos on and including backlite sheet of 5 mm thick with door and locking arrangements including provision of see through glass for each meter complete partly concealed in wall all as speciied and directed. Note :- 1. Supply and fix of MCCB TPN with 200 Amp bus bar shall be deemed included in quoted rates. 2. The energy meters dismantled and will be refixed in the above meter board. 3. Taking out existing loop of LT/UG cable and connecting in MCCB DB by replacing cable gland, lugs deemed to include the quoted rate 4. All outgoing service cables / submain to be connected in meters by providing lugs / cable glands deemed to include the quoted rate.
Deduct Credit for Demolished/ Dismantled material Rs. (-)92,670.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
R J ENTERPRISES
S R INFRASTRUCTURE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .