Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.4 LAccepted-AOC | 1 | Accepted-AOC bEING LOWEST BIDDER |
Tender Value
₹11.7 L
EMD Value
₹23,433
Closing Date
13 Nov 2024, 3:00 pmClosed
Lester Dsouza
W.D XX(PHE) PWD Fatorda Margao
Providing and commissioning of booster pump including replacement of pipeline at Voili Bandol of Kirlapal Dabal in Sanvordem Constituency.
2024_PWD_18000_1
PWD/WD-XX(PHE)/TN/2024-25/04 line 01
Open Tender
Civil Works - Water Works
Item Rate
120 days
W.D XX(PHE) PWD Fatorda Margao
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,000
₹23,433
1 Aug 2025
22 Oct 2024
15 Nov 2024
22 Oct 2024
13 Nov 2024
22 Oct 2024
Amount
Earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30cm depth, in foundation pipeline trenches, but exceeding 1.5m on plan) including disposal of excavated earth all lead and lift. Disposed earth to be levelled and neatly dressed including providing barricading, danger lighting guarding as directed by departmental officer in all types strata comprising any of the materials such as soil, silt sand clay gravel moorum of all conglomerated laterite rock, soft rock fissured shattered decomposed rock or weathered rock and all such other materials as described under Appendix A to these specification either in full or in parts as the case may be adopting any approved method of methods as may be convenient or permitted inclusive of chiselling, wedging etc, blasting prohibited in all conglomerates as directed by the Engineer-in-charge etc, complete.
Earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches, drain not exceeding 1.5m in width 10 sq.m on plan including dressing of sides ramming of bottoms for all lead and lift including setting out the excavated soil & disposal of surplus soil with all lead including providing barricading danger lighting guarding as directed by departmental officer in all types strata comprising any of the materials such as soil, silt sand clay gravel moorum of all conglomerated laterite rock, soft rock fissured shattered decomposed rock or weathered rock and all such other materials as described under Appendix A to these specification either in full or in parts as the case may be adopting any approved method of methods as may be convenient or permitted inclusive of chiselling, wedging etc, blasting probhibited in all conglomerates as directed by the Engineer-in-charge etc, complete.
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Centering & shuttering including Strutting, Propping & removal of forms for :
Foundations, Footings, Bases for columns
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing :
All works upto plinth level
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. C. I. Sluice valve conforming to IS:14846-2000 and bearing ISI mark double flanged with cap. TYPE P.N. 1.0 (Class B)
80mm dia
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. C.I. Reflux valve conforming to IS:5312 part-I. Valve double flanged ends without bypass arrangements and drilled to IS:1538 part IV & VI bearing ISI Certificate mark TYPE P.N. 1.0 (Class B)
80mm dia
Cutting of cast iron / ductile iron pipes by mechanical grinder working on electricity, including the cost of hire charges of mechanical grinder, diesel operated electrical generator set, suitable for supplying power for the grinder for cutting, cost of grinding blades , skilled work force, fueletc. required for completion of job as per the direction of Engineer- in -charge
100mm dia
Hoisting laying cast iron sluice valves/butterfly valves/reflux valve of size given below at location in pipeline etc. complete as directed as per IS:2685-1971 CLASS I
80mm dia
Supplying cast iron fittings as per IS : 1538 -1993 including sealing rubber gasket (NR) CI Compression glands and coated MS Nuts bolts.
Flanged Socket Tail piece ( Flanged Adaptors)
80mm dia
Making flanged joints for C.I./D.I. Pipes and specials with rubber insertion, nuts and bolts including necessary hydraulic testing etc. complete including cost of rubber insertion nuts and bolts, as directed by the Engineer in-charge.
80mm dia
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. cast iron single orifice type Air( fig S2confirming to IS 14848/2000 with suitable connections as directed by Engineer -In- Charge for working pressure of 10Kg/sq cm (TYPEP.N. 1.0) (Class A)
25mm dia
Fixing C.I. Single large orifice air valve of similar make with bronze ferrule at inlet screwed suitable to working pressure of 15kg/sq. cm for 12 mm to 20mm and 10kg/sq. cm for 25mm to 50mm, complete, as directed by the Engineer in-charge, of following sizes.
25mm dia
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint.
In R.S. joists, channels, angles, tees
Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in cm. 1 : 5 (1 cement : 5 coarse sand) in foundation upto plinth level
Providing and fixing prefabricated compound gate of G.I. pipes 40 – 50 mm dia (medium) with 12mm M.S. square bars of G.I. pipes grill work as per drawing including providing & fixing locking arrangements, pintals, hold fast embedded in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 granitic or basaltic aggreate 20mm nominal size) including applying priming coat with ready mixed red lead paint and painting 2 or more coats with superior ready mixed paint of approved brand and manufacture in all shades as per direction complete.
Providing and fixing G.I. chain link mesh 6.35cm x 6.35 cm x 10 gauge (2.5” x 2.5” x 10 gauge) fixed with angle iron posts and struts by G.I. or M.S. staples at 20cms apart with welding with the iron posts (placed at 3 meters centre to centre) including providing barbed wire stiffeners (shall weigh 9.33 kg. per 100 meters minimum) at top and bottom with barbed wire stiffers by binding wires at 50cms centre to centre complete as per the direction of the Engineer – in – charge (angle iron posts struts, earthwork and concrete for fencing posts and struts to be paid separately)
Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
Applying one coat of cement primer of approved brand and manufacture on wall surface.
Finishing wall with waterproofing cement paint of approved brand and manufacture and of required shade on new work (three or more coats) to give an even shade.
40 mm. thick red oxide flooring under layer of 30 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 12.5mm nominal size) and top layer of 10 mm thick plaster of cement red oxide mix using 3.5 kg. Of red oxide of iron per 50 kg. of cement 1:3(1cement : 3 coarse sand) finished with floating coat of neat cement red oxide mix of same proportion.
Supplying, Installation, Testing and commissioning of booster pump set varticle in line having a discharge of 3-5lps at 69-80 metre head motor 7.09 KW/5-7.5 HP/1440/RPM with SS shaft, SS impellar, SS difuser with cast iron casing and mechanical seal. Make kirloskar/Compton/ equivalent.
Supplying at store or site of work Rigid PVC (SEL FIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc. complete, conforming to IS: 4985-2000, and bearing ISI mark, Class 10 kg/cm2.
90mm dia
Conveying carefully from stack at site, 250m from both sides rolling and lowering in trenches, laying true to line and level and perfect linking for joints for P.V.C / H.D.P.E complete in all respects as per the direction of the engineer in-charge
Jointing of rigid / SEL FIT PVC pipes by cleaning the pipe with solvent cement including the cost of solvent cement and hydraulic testing of joints etc. complete as per IS:7634-1975 Part 3, including hydraulic testing of joints as directed by the Engineer in-charge.
90mm dia
Construction of masonry chamber 90x90x100 cm inside in 40kg/sq. cm brickwork complete with 23 cms wall thickness and in cement mortar 1:4( 1 cement : 4 coarse sand) for sluice valve of sizes 100 mm, 120 mm 150 mm and 200mm dia with necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) and inside plastered with CM 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing . (rate is inclusive of rate earthwork excavation, cost of surface cover and all other materials and labour and as per details below)
with C.I. Surface box 100mm top dia 160mm bottom dia and 160mm deep of wt 15kg inside with chain lid in 120 mm thick RCC slab cover in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone ballast 20 mm nominal size)
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Fabricating, providing, laying & jointing with MS flanged pipe & specials for delivery connections of pumps to a single delivery manifold as per requirement of size of delivery with each pump and size of common delivery & manifold for pumps of adequate dial size having thickness of standard size as per requirements of department including dish ends (if required) with each manifold and lifting arrangements, base frame of RSS channel, angle etc. complete. The cost is inclusive if cost of material, labour, fabrication unit, etc.
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing special protective masonry chamber as per enclosed drawing ( to be paid extra)( without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).
(a) In soily strata( Masonry chamber not included)
Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required
Extra for using salt and charcoal for pipe earth electrode as required (65 Kgs of Charcoal and 5 Kgs of Salt).
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .