Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹14.5 L+₹85,350 (6.26%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹16.5 L+₹2.8 L (20.7%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹17.8 L+₹4.2 L (30.8%)Rejected-Finance | L4 | Rejected-Finance not being lowest | |
| 5 | L5₹19.9 L+₹6.3 L (45.9%)Rejected-Finance 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L5 | Rejected-Finance not being lowest |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
29 Sept 2022, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Repair and maint of ceiling fans, exhaust fans, wall mounting fans, pedesal fan, roof turbine air ventilator and connected items at OTM accn and Repair/replacement of fire fighting/ detection system at CME, Pune
2022_MES_546000_2
8355/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer (CME) Kirkee
Class D, category b(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹54,000
Yes
3 Nov 2022
16 Sept 2022
1 Oct 2022
16 Sept 2022
29 Sept 2022
17 Sept 2022
Amount
Taking down folloiwing fans of any type and size from site and removing to MES store for servicing like cleaning, lubricating, greasing and replacement of split pin, bearing, bush, capacitor, connection wire and refixing the fans at same location after spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing complete all as specified and directed by Engr-in-Charge. Note :- (a) Contractor will provide one electrician and one helper for removing the faulty fan and refixing the serviced ceiling fan (b) Contractor team will report to AGE E/M Sub Div daily except sunday and holiday at 0900 Hrs to collect ceiling fan complaints. (c) Contractor will give one year guarantee for repairable fan except burnt out fans) (d) Rate quoted by the contractor shall be deemed to be inclusive of spare parts as required.
Ceiling fans of any size
Exhaust fans of any size (metal body)
Exhaust fans of any size (PVC body)
Wall mounting/air circulator fan of any size and type
M & L for replacement of burnt out coil of following fans and rewinding complete with super enamelled copper wire of same guage and weight including replacement of bearing, bush, capacitor, insulation paper and varnishing including spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing complete including taking down, removal to workshop and refixing upto satisfaction of Engr-in-Charge. Note :- 1. Rewinding work shall be carried out at AGE E/M store yard or any place decided by Engineer-in-Charge. 2. Contractor is responsible to give one year guarantee for rewinding fans)
Ceiling fan 1200/1400 mm sweep working on 230 volts AC supply
Exhaust fan upto 400 mm sweep working on 230 volts AC supply (metal body)
Exhaust fans upto 300mm sweep working on 230 volts AC supply (PVC body)
Wall mounting/air circulator fan of any sweep working on 230 volts AC supply
S & F in repair fan hanging hook any type or size suitable to hang on wooden block, MS bar etc with rubber reel, nuts, bolts, split pin etc suitable for ceiling fan complete all as specified and as directed by Engr-in-Charge.
S & F in replacement down rod made out of GI pipe medium grade 15mm dia with fan clamps incl drilling, cutting threading & white painting etc for ceiling fans 1200/1400mm sweep all as specified and directed by Engr-in-Charge.
S & F in repairs canopy for ceiling fans upper and bottom (Set of two) complete all as specified and directed.
Supply and fixing in replacement by cutting sizes water proof plywood ISI Marked, 12mm thick, of required size incl necessary provisions for mounting in walls, openings and securing using fasteners 10 cms long and 8 mm dia for mounting of exhaust fans in various locations and sizes as directed.
Taking down old unserviceable PVC ventilation/exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fix ventilation/exhaust fan made out of plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed.
Taking down old unserviceable PVC ventilation/exhaust fan after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fix ventilation/exhaust fan made out of plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200 to 250 mm complete all as specified and directed. Note:- Size of fan shall be decided by the Engineer-in-Charge.
Taking down old unserviceable ceiling fans after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M and supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S & F in replacement stepped type ,socket design electronic fan regulator flush type on the existing phenolic laminated sheet etc.suitable for 1200 mm sweep ceiling fan all as specified and directed incl taking down old UNSV one..
S&F in replacement louver shutter of exhaust fan upto 400 mm size round or square as per site condition including fixing arrangement with fixing material complete all as specifed and directed.
Supply and fix in replacement terminal connector 3 way complete all as specified and directed.
Supply and fix in replacement capacitor 2.5 mfd 230 volts complete all as specified and directed.
Supply and fix in replacement capacitor 4 mfd 230 volts complete all as specified and directed.
S&F MS screw for fixing of ceiling fan blade of any size and type complete all as specified and directed.
S&F in replacement of fan blade suitable for 1200mm dia ceiling fan complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
S&F in replacement of fan blade suitable for 1400mm dia ceiling fan complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
S&F in replacement of fan blade suitable for upto 300 mm dia PVC exhaust fan complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
S&F in replacement of PVC fan blade suitable for wall mounted fan upto 600mm dia complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
S&F in replacement of wall mounted fan blade guard of size upto 600 mm dia complete all as specified and directed. Note : Blade shall be suitable for Bajaj/ Crompton/ Usha/ Havells/ Polar make fans.
Periodical maintenance of various conventional/addressable type fire alarm sytems in various bldgs in CME campus including checking, testing, cleaning & services of smoke detector, fire alarm panel, manual call point, hooter and electric circuit complete all as specified and directed. Note :- (i) Spares if any required shall be measured and paid for separately only labour elment is deemed to be included in this item. (ii) Contractor is responsible to arrange suitable size ladder as to reach to fire/smoke eqpts. (iii) Area controlled by one fire alarm panel shall be considered as one job for testing and payment purpose.
Supply only Ionisation Smoke detector complete all as specified and directed.
Supply only photo electric (Optical) smoke detector complete all as specifed and directed.
Supply only heat detector complete all as specified and directed.
Supply only zone card upto 4 zone complete all as specified and directed.
Supply only control card complete all as specifed and directed.
Supply only power supply card complete all as specified and directed.
Supply only battery charging card complete all as specified and directed.
Supply only fail card complete all as specified and directed.
Supply only manual call point switches complete all as specified and directed.
Supply only manual call point glass complete all as specified and directed.
Supply only response indicator complete all as specified and directed.
Supply only hooter card complete all as specified and directed.
Supply only lead acid battery, 12 Volts, 7 AH complete all as specified and directed.
S&F in replacement fire alarm panel suitable for four zone i.e 4 Nos alarm initiating circuit, type class A or B end of line 3.9 K, loop powered device current 1.8 A alarm current 500 mA double output i.e alarm relay change over voltage free contact & fault relay change over voltage free contact duly monitored by means of line for sounders, auxillary power out put having autonomy with and including 2 Nos 12 volts 7 AH batteries and terminal etc with 12 hours on standby and 30 minutes in alarm condition detection line duly protected from short ciruiting suitable for audio and visual alarm indication, panel conforming to CE and EN 54 part & 4 standard complete all as specified and directed.
S&F in replacement manual call point wall mounted type made of cast aluminum signal red finish suitable for operation on 24 volt DC complete all as specified and directed.
S&F in replacement hooter 40 W suitable for 12-24 volt DC working upto 30 V (for max 30 minutes) having max current consumption of 70 mA sound pressure level 100 db complete all as specified and directed.
Supply and laying in replacement copper conductor PVC armoured cable 1.5 Sqmm, 2 core for fire alarm system between and inside different rooms, fixed with and including saddles on wall/ceiling surface drawn in and including 20mm dia steel conduit heavy grade fixed on wall/roof including all material required for laying/fixing complete all as specified and directed. Note : One metre 1.5 Sqmm cable alongwith steel conduit shall be measured as one length for payment purpose.
M/S Eagle Electricals And Rewinding Works
metro electrical services
Pritam Electro Mechanical Services
RELIABLE ENTERPRISES
E M CONSTROL SYSTEM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .