Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹28.1 L+₹4.9 L (21.1%)Rejected-AOC C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹31.0 L+₹7.8 L (33.5%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹32.9 L+₹9.7 L (41.7%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹36.8 L+₹13.5 L (58.4%)Rejected-AOC | L5 | Rejected-AOC Other than L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
26 Jul 2023, 6:00 pmClosed
Garrison Engineer
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
COMPREHENSIVE REPAIR/MAINTENANCE OF CEILING FANS, GEYSERS, EXHAUST FANS, WALL MOUNTED FANS, AT TANDA AREA INCLUDING COMPREHENSIVE REPAIR/MAINTENANCE OF WIRING, INTERNAL / EXTERNAL FITTINGS AND FIXTURES FOR OTM ACCN AND MD ACCN IN AKHNOOR
2023_MES_606559_1
CANO- GE(N)/AKH-32/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Akhnoor and Tanda
Class D Category b(i)
9 documents required · 9 mandatory
₹500
GE (North) Akhnoor
₹84,000
Yes
31 Oct 2023
28 Jun 2023
2 Aug 2023
28 Jun 2023
26 Jul 2023
12 Jul 2023
Amount
M&L for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs,all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc.shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed.
Note for item No 1: The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
The entire job will be carried out in Akhnoor station and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs.
Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor's responsibility.
Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Supply only rotor of ceiling fan of any size
Supply only fan canopies for ceiling fan size of 1200mm/1400mm
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers.
Supply only outer body of ceiling fan of any size
Supply only blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
M&L painting the ceiling fan 1200mm /1400 mm sweep with one coat of syntetic enamel paint as existing colour and writing the MES No- as directed by Engr in Charge.(taking down of fan,and re hanging measured under item No. 2 seperately. Note:- Painting of ceiling fan shall be done inside MES complex only.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule. (iii)taking down of fan,and re hanging measured under item No. 2 seperately.
Material and labour for winding of ceiling fan motor 1400 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule. (iii)taking down of fan,and re hanging measured under item No. 2 seperately.
Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200 mm sweep, energy efficient ISI mark with 5 star rating(BLDC) 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient./Halonix Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work. (b) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Taking down of exhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) are deemed to be inclusive in quoted rate all as specified and as directed. (Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.)
Note : The following shall be deemed to be inclusive in the unit quoted rate :- In each job checking of functioning of fan including its connections, cleaning of fan, greasing of fan, mechanical check i.e. tightening of loose screw , nuts, bolts, are inclusive in unit quoted rate.
The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
Defecting unserviceable part like fan bush, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
The entire job will be carried out in Akhnoor and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs.
Necessary complaint slip/complaint register & other stationery required shall be contractor responsibility.
Necessary T&P such as ladder, helper shall be contractor responsibility.
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Material and labour for winding of Exhuast fan 450 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule.
Description all as per Sl item No 21 here in above but 300 mm sweep
Description all as per Sl item No 21 here in above but 230 mm sweep
Supply only fan bush of suitable size for exhaust fan of the any sweep
Supply only 4 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 450mm sweep
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing.
Supply only 3.15 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 300mm sweep
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 230mm sweep
M&L painting the exhaust fan of 450mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop .as directed by Engr in Charge. Note:- Painting of Exaust fan shall be done inside MES complex only.
All as per item No 33 above but 300 mm sweep
All as per item No 33 above but 230 mm sweep
S&F Domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt suqare type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic/ fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make- havells model-Ventil Air-DB or equivalent in bajaj, Almonard. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
S&F Domestic Exhaust Fans for kitchen, 450 mm sweep, 230 volt suqare type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic/ fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make- havells model-Ventil Air-DB or equivalent in bajaj, Almonard. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
S&F Exhaust fan 200 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells Cat No Ventil DX-WH/BLK or equivalent in bajaj, Crompton Greaves etc. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Supply and fixing in replacement sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors/concealed along with 1 runs of 2.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/ Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 2 runs of 4 sqmm cable along with one run of 2.5 sqmm cable for earth conductor alongwith suitable size PVC casing capping/Pipe shall be measured as one length.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors/concealed along with 1 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/ Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 2 runs of 6 sqmm cable along with one run of 4 sqmm cable for earth conductor alongwith suitable size PVC casing capping/Pipe shall be measured as one length.
Taking down and dismantling geyser of any make and cap 25/50 ltrs & taking out water inlet outlet assly, removing glass wool and taking out the inner tank, descaling the assembly and tank , detecting the leakage, welding / brazing the defected part , repacking the glass wool and refixing the same after making it funcional including replacement of worn out nuts bolts washer etc complete all as specified and directed. Note: Cost of material and labour for providing new items shall be measured under relevant items of sch A.
Supply and fixing in replacement of water inlet and outlet assembly of any make as required at site with rubber gasket suitable for geyser of 25 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element fixing arrangement nuts bolts and washers etc. complete all as specified and directed .
Supply and fixing in replacement of water inlet and outlet assembly of any make as required at site with rubber gasket suitable for geyser of 50 ltrs capacity electric driven water storage heater with provn of housing for thermostat assembly, heating element fixing arrangement nuts bolts and washers etc. complete all as specified and directed .
Supply & fixing in replacement thermostat switch for electric water heater storage type of cap 25/ 50 ltr, 230 volts of any make of geyser.
S&F in replacement heating element with triangular base ISI marked, single phase, 230 volt, cap 1.5 KW. All as specified and directed.
S&F in replacement heating element with round base suitable for Bajaj geyser having electronic cutout plate ,ISI marked single phase, 230 volt, capacity 1.5 KW all as specified and directed.
S&F for replacement heating element with triangular base ISI marked, single phase, 230 volt, cap 2 KW all as specified and directed.
S&F for replacement heating element with round base ISI marked, single phase, 230 volt, cap 2 KW all as specified and directed..
Supply and fixing in replacement pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe/tubing 15mm bore complete all as specified and directed.
Supply and fixing in replacement of heavy duty PVC connection nylon threaded 450mm large (18”) 15mm bore including brass nuts, rubber washers complete on both ends.
Supply and fixing in replacement of indicator lamps round/rectangular type 230 volt AC suitable for geyser of any capacity including providing electric connections complete all as specified & directed.
Supply & fixing in replacement water storage inner tank of SS material for 25 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed.
Supply & fixing in replacement water storage inner tank of SS material for 50 ltrs capacity geyser, with provn for fixing 15mm dia galvanized air release valve all as specified and directed.
Supply & fixing in replacement MCB SPN 20 Amps 240 volts , rupturing cap 10 KA, 'C' series all as specified and directed.
Supply & fixing in replacement MCB DB 2 way complete with fixing accessories all as specified and directed. Make Havells,Indoasian, Schnieder.
Supply & fixing in replacement thermal cut out Bimetallic disc type with snap action switch, with operation temperautre below the boiling point i.e. 90+ 6˚C with manual reset knob for Geyser.
Supply and fixing in replacement plug top 15 Amps 3 pins all as specified and directed. Make Havells REO, Schnieder, Indiasian
Material and labour for painting of geyser of cap 25/ 50 ltr complete with superior quality synthetic enamel white paint by spray painting after scraping old paint and making surface clean all as specified and directed. Note: contractor has make an arrangement for spray painting within premises of Garrison as directed and specified by Engr -in-charge and rate quoted deemed to include to remove, transport Geysers from bldgs to specified loc for cleaning and painting and reconnected at same place after doing needful
Supply and fixing in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed. Make Godrej/Havells(Monza EC),or equivalent Note:- Old Unserviceable geysers shall be deposited to MES store yard.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and apply 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Make of Cables Havells, KEI, Grandlay (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
One light point/fan /bell point controlled by one switch.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Make of Cables Havells, KEI,Grandlay (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
One 15 amps power socket outlet point controlled by one 16 amps switch on independent board.
Supply & fixing modular type switch 6 Amps, single pole, 1way,1 module,240V, ISI Marked complete all as specified and directed. Make Crabtree,Havells, Wipro,
Supply & fixing modular type switch 16 Amps, single pole,1 way,1 module,240V, ISI Marked Complete all as specified and directed. Make - Crabtree,Havells, Wipro,
Supply & fixing modular type socket shuttered type 6 Amps- 2/3 Pin combined 2 module,240V,AC ISI Marked Complete all as specified and directed. Make Crabtree,Havells, Wipro,
Supply & fixing modular type socket 6 A/16 Amps -2/3 Pin combined shuttered socket 2 module 240V AC ISI Marked Complete all as specified and directed .Make-Crabtree,Havells, Wipro,
Supply & fix fan regulator modular type electronic, stepped type 100 Watts, 2 module 240Volts,AC ISI marked complete all as specified and directed. Make- Crabtree,Havells, Wipro,
Supply and fixing sheet metal enclosure double door type for DBs single pole and neutral 12 way 240 V with 200 Amp bus bar including blanking plates where required . Make : Crabtree,Havells, Wipro,
Supply and fixing sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V with 200 Amp bus bar including blanking plates where required . Make : Legrand, Schiender, Havells,L&T etc.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. Make of Cable Havells, KEI, Grandlay
Supply and fixing in replacement Integrel sleek surface mounted LED fitting fixture( 4 feet length), 18 watt with integral electronic driver complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size cable incl testing after fixing all as specified and directed by Engr - in-charge . The specification of the light fitting should meet the following:- Make Wipro, Phillips, Surya
Housing of Light fitting : aluminium Extruded
Operating voltage : 150 v to 270v
operating temprature : -10 to 45 degrees
Lumen efficacy : 100 lumen per watt
system lumen : Not less than 1800 lumens
Colour temprature : Not less tha 5700k
Surge voltage protection : Up to 2 KV
Ingress protection : IP20
Total harmonic distortion : not less than 20%
Power factor : not less than 0.90
Input Frequency : 50 HZ
Line protection : Under/ Over voltage protection
Supply and fixing in replacement of 10 watt Bulkhead Designed with beautiful aesthetics using new generation technology in LED to enliven your outdoor and indoor areas in perfect synchronization with functionality and aesthetics. Family of bulkhead Lights designed to compliment thegeometry of the area with modern design. High quality polycarbonate UV Protected milkydiffuser is used for glare free light distribution complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of the panel light fitting should meet the following:- Make Wipro, Phillips, Surya
Housing of Light fitting : Die cast Aluminium
Polycarbonate UV protected diffuser
Operating voltage : 140 v to 270v
operating temprature : -10 to 45 degrees
Lumen efficacy : 100 lumen per watt
system lumen : Not less than 900 lumens
Colour temprature : Not less than 5700K
Surge voltage protection : Up to 4 KV
Ingress protection : IP65
Total harmonic distortion : not less than 20%
Input Frequency : 50 HZ
Supply and fixing in replacement of 36 watt 2x2 panel Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/ Grid ceiling Delivers excellent illumination & comfort in high ceiling areas Long life & photobiologically safe LED’s High performance electronic driver ensures zero maintenance No harmful UV & IR radiations Environment friendly as it does not contain Mercury Instant light, High transmittance PMMA opal diffuser for glare free symmetric light distribution.Powered by an Built-In electronic driver (SMPS based constant current supply) complete making connection and testing after fixing all as specified and directed by Engr-in-charge .The specification of the panel light fitting should meet the following:- Make Wipro, Phillips, Surya
Housing of Light fitting : CRCA Powder Coated
Operating voltage : 150 v to 270v
operating temprature : -10 to 45 degrees
Lumen efficacy : 110 lumen per watt
system lumen : Not less than 3600 lumens
Colour temprature : Not less tha 5700k
Surge voltage protection : Up to 2 KV
Ingress protection : IP20
Total harmonic distortion : not less than 20%
Power factor : not less than 0.90 Line protection : Under/ Over voltage protection
lnput Frequency : 50 HZ
Usha Engineering Co.
M/S SOHUM ENGINEERS
VISHAL CONSTRUCTION
Jiwan Singh
DARVESH ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .