Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance | ₹1.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹5.2 L (3.88%)Admitted-Finance 77 DR ZAKIR HUSAIN WARD NEAR GAZI MASJID NAI BASTI GOHALPUR JABALPUR NAI BASTI GOHALPUR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | ₹1.4 Cr+₹5.2 L (3.88%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹5.7 L (4.24%)Admitted-Finance | ₹1.4 Cr+₹5.7 L (4.24%) | L3 | Admitted-Finance |
| 4 | L4₹1.4 Cr+₹8.3 L (6.18%)Admitted-Finance | ₹1.4 Cr+₹8.3 L (6.18%) | L4 | Admitted-Finance |
| 5 | L5₹1.4 Cr+₹8.5 L (6.28%)Admitted-Finance | ₹1.4 Cr+₹8.5 L (6.28%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ABHISHEK ASSOCIATES L1 | ROSHAN REFRIGERATION AND ELECTRICALS L2 | PAN POLAR ENGINEERS PVT. LTD. L3 | CIS ELECTRICALS PVT LTD L4 | N L Neema L5 | surbhi association L6 | Manish Electricals L7 | RSP ELECTRICALS L8 | S. N ELECTRICALS L9 | ANAND AND COMPANTY L10 | R. D. ENGINEERS L11 | JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED L12 | CHENNAI ENGINEERING SERVICES L13 | JAI ENTERPRISES L14 | Skyline Airconditioning Engineers Pvt. Ltd. L15 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Annual operation & Maintenance of various electrical installations of GLF systems,Nav-Aids,Old Terminal building,Old power House,Technical block, residential colony including street lights, etc. and operation of water supply pumps at colony & Old TB i/c repair/maintenance, attending the complaints,taking rectification action on all working days with man power in three Shifts (A,B,C )including Sunday & Holidays,keeping records of all maintenance activities complete as required as per Specical conditions of Contract and the detailed specifications terms covered under this contract. | 24 | Month | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 2.10 | Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required.
3.0 HP (For First Year) | 1 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 2.20 | Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required.
7.5 HP (For First Year) | 2 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 2.30 | Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required.
10.0 HP (For First Year) | 1 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 2.40 | Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required.
3.0 HP (For second Year) | 1 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 2.50 | Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required.
7.5 HP (For second Year) | 2 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 2.60 | Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required.
10.0 HP (For second Year) | 1 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 3.10 | Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer)
3.0 HP (For First Year) | 1 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 3.20 | Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer)
7.5 HP (For First Year) | 2 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| 3.30 | Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer)
10.0 HP (For First Year) | 1 | Job | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Tender Value
₹1.7 Cr
EMD Value
₹3.3 L
Closing Date
27 Jan 2020, 6:00 pmClosed
SM (Engg.-Elect.), AAI, DABH Indore Airport.
AAI, DABH Airport, Indore.
ARMO of E and M Installations of GLF Systems, Nav-Aids, OTB, Old Power House, Technical Block and Residential Colony and CMC of Window and split ACs etc. at DABH Airport , Indore for 02 ( Two) years ( 2020-2022)
2020_AAI_39798_1
AAI/ID/SM (E-E)/NIT-13/2019-20
Open Tender
Electrical Works
Works
730 days
Indore Airport
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,180
Yes
Airports Authority of India
₹3.3 L
Yes
12 Feb 2020
13 Jan 2020
4 Feb 2020
13 Jan 2020
27 Jan 2020
13 Jan 2020
13 Jan 2020 - 20 Jan 2020
Amount
Annual operation & Maintenance of various electrical installations of GLF systems,Nav-Aids,Old Terminal building,Old power House,Technical block, residential colony including street lights, etc. and operation of water supply pumps at colony & Old TB i/c repair/maintenance, attending the complaints,taking rectification action on all working days with man power in three Shifts (A,B,C )including Sunday & Holidays,keeping records of all maintenance activities complete as required as per Specical conditions of Contract and the detailed specifications terms covered under this contract.
Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required. 3.0 HP (For First Year)
Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required. 7.5 HP (For First Year)
Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required. 10.0 HP (For First Year)
Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required. 3.0 HP (For second Year)
Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required. 7.5 HP (For second Year)
Lifting and Lowering of Submersible Pump below ground level upto 450 ft including transportation,loading,unloading charges, bearing and greasing etc. complete as required. 10.0 HP (For second Year)
Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 3.0 HP (For First Year)
Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 7.5 HP (For First Year)
Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 10.0 HP (For First Year)
Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 3.0 HP (For second Year)
Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 7.5 HP (For second Year)
Complete rewinding of the motor of following capacity Submersible pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 10.0 HP (For second Year)
Complete rewinding of the motor of following capacity monoblock pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 3.0 HP (For First Year)
Complete rewinding of the motor of following capacity monoblock pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 5.0 HP (For First Year)
Complete rewinding of the motor of following capacity monoblock pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 10.0 HP (For First Year)
Complete rewinding of the motor of following capacity monoblock pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 3.0 HP (For second Year)
Complete rewinding of the motor of following capacity monoblock pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 5.0 HP (For second Year)
Complete rewinding of the motor of following capacity monoblock pump including transportation,loading,unloading charges, bearing and greasing etc complete as required.(Agency shall be responsible for rewinding and repairing of motor-pump set for 06 months and dismantled material shall be the property of tenderer) 10.0 HP (For second Year)
Complete rewinding of ceiling/wall fan including transportation, loading, unloading charges etc. complete as required. For First Year
Complete rewinding of ceiling/wall fan including transportation, loading, unloading charges etc. complete as required. For Second Year
Complete rewinding of following size exhaust fan including transportation, loading, unloading charges etc. complete as required. up to 225 mm size (For First Year )
Complete rewinding of following size exhaust fan including transportation, loading, unloading charges etc. complete as required. up to 450 mm size (For First Year )
Complete rewinding of following size exhaust fan including transportation, loading, unloading charges etc. complete as required. up to 225 mm size (For second Year )
Complete rewinding of following size exhaust fan including transportation, loading, unloading charges etc. complete as required. up to 450 mm size (For second Year )
Inspection, servicing and testing of oil circuit breaker of 3 Pole, 600A , 11 KV Oil Circuit Breaker in the HT panel (Make: Crompton Greaves) from Manufacturer or Authorised Service Dealer or Specialised Agency installed at Old power house alongwith submission of the test reports. For First Year
Inspection, servicing and testing of oil circuit breaker of 3 Pole, 600A , 11 KV Oil Circuit Breaker in the HT panel (Make: Crompton Greaves) from Manufacturer or Authorised Service Dealer or Specialised Agency installed at Old power house alongwith submission of the test reports. For Second Year
Inspection, Servicing, Setting, Calibration and Testing of relay(2 nos. O/C relay & 1 no. E/F relay-4 Sets) of oil circuit breaker of 11 KV HT panel of old power house complete in all respect along with submission of test report. For First Year
Inspection, Servicing, Setting, Calibration and Testing of relay(2 nos. O/C relay & 1 no. E/F relay-4 Sets) of oil circuit breaker of 11 KV HT panel of old power house complete in all respect along with submission of test report. For Second Year
Dehydration and filtration of transformer oil at site includnig testing the BDV and acidity before and after testing and submission of test reports etc. as required for 750 KVA, 11/0.415 KV Transformers. For First Year
Dehydration and filtration of transformer oil at site includnig testing the BDV and acidity before and after testing and submission of test reports etc. as required for 750 KVA, 11/0.415 KV Transformers. For Second Year
Supply of tested transformer oil for topping up in transformers as required. For First Year
Supply of tested transformer oil for topping up in transformers as required. For Second Year
Inspection, Servicing and Testing (all tests) of 750 KVA, 11/0.415 KV Transformers of old power house includes replacement of silica gel, rectification of any oil leakage etc. as required at site along with submission of test report. For First Year
Inspection, Servicing and Testing (all tests) of 750 KVA, 11/0.415 KV Transformers of old power house includes replacement of silica gel, rectification of any oil leakage etc. as required at site along with submission of test report. For Second Year
Painting of following poles in 2 coats by using Aluminium paint of approved make (Asian / Berger) including pole boxes, cleaning of surface etc., as required including rewriting the identification Sl.No. 80 mm Dia Gl pipe pole of length not exceeding 2 Mt.
Spray Painting of sheet metal enclosures of electrical panels / feeder pillars inside the power house, Pump room & ATC building including cleaning the surface and one coats of grey or any other color of make (Asian / Berger) including rewriting the identification the circuit, Protecting and covering the electrical accessories during painting and removing after work is over etc., as reqd.
Supply of 200 W, 6.6 Amp Bi pin Halogen Lamp suitable for PAPI fitting installed at DABH Airport Indore.
Supply of 150 W, 6.6 Amp Bi pin Halogen Lamp suitable for Runway Edge light fitting installed at DABH Airport Indore.
Supply of 105 W, 6.6 Amp Bi pin Halogen Lamp suitable for inset fitting installed at DABH Airport Indore.
Supply of Lamp Holder for 200 W, 6.6 Amp Bi pin Halogen Lamp suitable for PAPI fitting installed at DABH Airport Indore.
Supply of Neoprene type Inner Gasket suitable for Runway inset fitting YOUYANG make installed at DABH Airport Indore.
Supply of Neoprene type Outer Gasket suitable for Runway inset fitting YOUYANG make installed at DABH Airport Indore.
Execution of works as per CPWD DSR (E&M) 2018, DAR (E&M) 2018 & Latest CPWD Specifications as & when required. CPWD DSR (E&M) - Chapter 1 to 10 & 14 The rate shall be quoted for this item as per examples given below: - Please refer SCC before quoting rates for this item. • If Bidder wants to quote the rate at par with rates of DSR - 2018 (E&M), then bidder has to quote 1.00 in the rate column. • If Bidder wants to quote the rate 10 % Above the rates of DSR - 2018 (E&M), then bidder has to quote 1.10 in the rate column. • If Bidder wants to quote the rate 10 % Below the rates of DSR - 2018 (E&M), then bidder has to quote 0.90 in the rate column. First Year
Execution of works as per CPWD DSR (E&M) 2018, DAR (E&M) 2018 & Latest CPWD Specifications as & when required. CPWD DSR (E&M) - Chapter 1 to 10 & 14 The rate shall be quoted for this item as per examples given below: - Please refer SCC before quoting rates for this item. • If Bidder wants to quote the rate at par with rates of DSR - 2018 (E&M), then bidder has to quote 1.00 in the rate column. • If Bidder wants to quote the rate 10 % Above the rates of DSR - 2018 (E&M), then bidder has to quote 1.10 in the rate column. • If Bidder wants to quote the rate 10 % Below the rates of DSR - 2018 (E&M), then bidder has to quote 0.90 in the rate column. Second Year
Annual Comprehensive Maintenance Contract of the following Capacity AC units (including compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1 TR Window/split Type AC Units ( For First year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units (including compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1.5 TR/ 2.0 TR Window/split Type AC Units ( For First year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units (including compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 3.0 TR Split/Cassette Type AC Units ( For First year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units (including compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1 TR Window/split Type AC Units ( For Second year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units (including compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1.5 TR/ 2.0 TR Window/split Type AC Units ( For Second year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units (including compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 3.0 TR Split/Cassette Type AC Units ( For Second year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units( excluding compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1 TR Window/split Type AC Units ( For First year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units( excluding compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1.5 TR/ 2.0 TR Window/split Type AC Units ( For First year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units( excluding compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 3.0 TR Split/Cassette Type AC Units ( For First year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units( excluding compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1 TR Window/split Type AC Units (For Second Year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units( excluding compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 1.5 TR/ 2.0 TR Window/split Type AC Units (For Second Year )
Annual Comprehensive Maintenance Contract of the following Capacity AC units( excluding compressor) installed at various locations in the Airport Premises as per general and special terms and conditions attached. 3.0 TR Split/Cassette Type AC Units (For Second Year )
Supply and fixing of suitable size copper refrigerant piping with expanded polythene foam insulation tubing covering for A/C units.
ROSHAN REFRIGERATION AND ELECTRICALS
PAN POLAR ENGINEERS PVT. LTD.
CIS ELECTRICALS PVT LTD
N L Neema
surbhi association
Manish Electricals
RSP ELECTRICALS
S. N ELECTRICALS
ANAND AND COMPANTY
R. D. ENGINEERS
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
CHENNAI ENGINEERING SERVICES
JAI ENTERPRISES
Skyline Airconditioning Engineers Pvt. Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
FINALOTBTENDER.pdf
Tender Documents • 6.99 MB
BOQ_42999.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .