| 1 | 01₹60.9 LAccepted-AOC 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | 01 | Accepted-AOC Due to rates on lower side | |
| 2 | 02₹66.9 L+₹6.0 L (9.83%)Rejected-AOC | 02 | Rejected-AOC Due to rates on higher side | |
| 3 | 03₹98.7 L+₹37.8 L (62.0%)Rejected-AOC HOUSE NO 3123 66 WARD NO 23 SATI COLONY REWARI 123401 | REWARI | REWARI | HARYANA | 123401 | 03 | Rejected-AOC Due to rates on higher side |
Tender Value
₹65.5 L
EMD Value
₹1.3 L
Closing Date
29 Sept 2020, 5:00 pmClosed
Executive Engineer
PHED No.2 Meham Road Bhiwani
Crossing of railway track by 600mm/ 300mm dia MS casing pipe for passing 350mm/150mm dia DI pipe under track at KM 28/7-8 on ROK-BNW section under ADEN/Bhiwani and all other work contingent thereto CM announcement code No.12681 dated 10.06.2016
2020_HRY_145139_1
E-In-C, Hr No.80079-PHE/Mont dt. 15/09/2020
Open Limited
Civil Works
Works
180 days
Village Kharak Kalan
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Executive Engineer PHED No.2 Bhiwani
₹1.3 L
Yes
25 Nov 2020
21 Sept 2020
30 Sept 2020
21 Sept 2020
29 Sept 2020
21 Sept 2020
Amount
N.S Item
Probe Rader survey to check any underground obstruction finalizing the alignment complete.
Boring/excavation including pit making at entry and exist point to the precise dimensions for the launch of the specialized auger boring machine in rock/bolders any underground utility like foundation, water supply line coming in alignment or other under ground obstruction under Railway tracks Rewari - Sadalpur section suitable for M.S. casing pipe of following sizes complete in all respect using laser technique to ensure Horizontal boring including caution & sing board (i) For 600mm i/d 8mm thick M.S. casing pipe
For 300mm i/d 5mm thick M.S. casing pipe
Coating of 600mm & 300mm i/d MS pipe outer and inner surface of casing pipe with high build epoxy paint as per RDSO specification No. M&C/PCN III 88 to a dry firm thickness 2500mm micron for protection complete. i) 300mm i/d
Laying /excavation including covering Design mix concrete M-25 by cutting and cover method/ excavation to the precise dimensions in normal 6 oil condition but not in Rcold Bolders normal,/ any under ground utility like foundation, water supply line coming in alignment or other under ground Obstruction under Railway Track Rewari -Sadalpur Section suitable .lor M.S. casing pipe of Following sizes complete in all respect using cutting S cover method technique i) For 600mm i/d
For 300mm i/d
Providing and inserting of M.S. casing pipe Fe-3300 grade fabricated as pet IS : 3589 of 991 from steel plants confirming to IS 2062 & IS 1216/98 of size 600mm i/d including cutting. Beveling grid lining & radio Hraphically welding of pipe as per IS -1182 complete in all respect incl. carriage to site of work & testing. i) For 600mm i/d
For 300 mm i/d
Cleaning of surface 600 mm & 300mm i/d MS pipe (casing pipe and carrier pipe ) inner surface and outer surface by sand blasting at site to make the surface ready for P.U. coating /high build epoxy paint/polythene tap system complete in all respect i) for 600mm i/d
For 300 mm i/d
Providing and inserting of water carrier pipe 366 mm & 162mm Outer dia MS pipe & orpe 8mm thick & 6mm thick ( FE 330 grade fabricated as per IS 3589 of 1991 from steel plantes confirming to IS 2062 including inner linning by cement concrete mortar which shall be prepared from aggregates sand and cement contants of 450 KG /nl3 having strength of 25 N/mm2 after 20 Days complete as per IS 1916 :1989 with lealest revision providing Roller arrangement for smooth insertion anchoring of pipe through out the length with HDPE spacers all a distance of 2 meters apart to avoid contract of casing pipe 7 carrier pipe including cutting ,jointing ,Radio graphically welding as per IS 1182 Hydraulic testing complete in all respect including cartage at site of work. i) For 350mm i/d
For 150mm i/d
Providing and fixing HDPE specer at a distance of 2 Meters apart to avoid contract of casing pipe and carrier pipe complete in all respect. i) For 300mm i/d M.S. pipe
For 150mm i/d M.S. pipe
Providing & Design mix concrete M-25 to plug & fill the space between casing pipe and carrier including cost of pumping etc. complete in all respect as per approved NIT i) 300mm i/d
SUNIL SHARMA
Sachin Goyal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .