Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC | ₹4.0 Cr | L1 | Accepted-AOC FINANCIALLY RESPONSIVE BIDDER |
Tender Value
₹4.1 Cr
EMD Value
₹8.2 L
Closing Date
14 Nov 2023, 2:00 pmClosed
DIRECTOR OF PHYSICAL PLANT,KHANAPARA
DIRECTORATE OF PHYSICAL PLANT,KHANAPARA
CONSTRUCTION OF IVF LABORATORY AND TRAINING HALL under Rastriya Gokul Mission at College of Veterinary Science,Khanapara,Guwahati, Assam Agricultural University
2023_AAU_32948_1
AAU/DPK/2023-24/3998-4010 DTD.05.10.2023
Open Tender
Construction Works
Item Rate
365 days
COLLEGE OF VETERINARY SCIENCE, KHANAPARA
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,200
₹8.2 L
Yes
DIRECTORATE OF PHYSICAL PLANT,KHANAPARA
5 Jan 2024
10 Oct 2023
14 Nov 2023
10 Oct 2023
14 Nov 2023
10 Oct 2023
10 Oct 2023 - 26 Oct 2023
26 Oct 2023
Amount
Earthwork:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. (All kinds of soil. )
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Concrete Works:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size).
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size).
Reinforced Concrete Cement:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) All works upto plinth level.
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Concrete work:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources,Column, All works above plinth level upto floor V level
Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Formwork:Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel Reinforcement:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level .Thermo-Mechanically Treated bars of grade Fe-500D or more.
Soling Work:Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Masonry Work:Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Wood and PVC Work:Providing wood work in frames of doors, windows, clerestory windos and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Sal Wood
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
GRILL:Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
Cladding:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Flooring:Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
Size of Tile 600 x 1200 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size.Size of Tile 600 x 600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
1:6 (1 cement: 6 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture
Finishing:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Applying Priming Coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Windows:Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
DOOR AND WINDOW FITTINGS: Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing brass curtain rods of wall thickness 1.25mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 20 mm diameter.
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete .
Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 125x70x4 mm (ordinary type) .
WATERPROOFING:Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
PRE-CAST SLAB:Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
INTERNAL SANITARY WORKS:Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Western W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.
Providing and fixing toilet paper holder C.P. brass
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board.510x1040 mm bowl depth 250 mm.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 45 cm length.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
Providing and fixing PTMT grating of approved quality and colour. 18.58.1 Circular type 18.58.1.1 100 mm nominal dia
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes
25 mm nominal dia Pipes
32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.25 mm nominal dia Pipes
32 mm nominal dia Pipes
50 mm nominal dia Pipes
100 mm nominal dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.75 mm diameter
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Bend 87.5°75 mm bend
Providing and fixing on wall face unplasticised-PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion. Shoe Plain75 mm shoe
INTERNAL ELECTRICAL WORKS:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75mmx75mmx60mm deep
100mmx100mmx60mm deep
150mmx150mmx60mm deep
200mmx125mmx60mm deep
200mmx150mmx60mm deep
200mmx250mmx60mm deep
200mmx300mmx60mm deep
200mmx300mmx100mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: 5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket
6 pin15/16 A socket
TV antenna socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module
4 Module
6 Module
8 Module
12 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation testing and comissioning of prewired, flouriscent fitting/compact flouriscent fitting of all types, complete with accessories and tube/lamp directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor single core cable and earthing etc as required
Installation testing and comissioning of ceiling fan, including wiring the down rods of standard length 30 cm with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable as required.
Installation of exhaust fan in the existing opening, including making good the damages,connection,testing and commissining etc. as required. 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm
Installation,testing and commissioning of prewired fluorescent fitting compact fluorescent fitting of all types complete with all accesssories and tube/lamp etc. directly on ceiling/wall, including connection with 1.5sqmm FRLS PVC insulated,copper conductor, single core cable and earthing etc as required.
Installation,testing and commissioning of ceiling fan, including wiring the down rods of standard length(upto 30cm) with 1.5sqmm FRLS PVC insulated,copper conductor, single core cable and earthing including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damages,connection,testing and commissining etc. as required.Upto 450mm sweep.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP&N
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.160 Amp, 16 KA, TP MCCB
Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 650/1100 V grade conforming to IS 7098 (Part - I) / 1988 with amendment up to date etc as required.3 1/2 Corex 70 sqmm aluminium
EXTERNAL ELECTRIFICATION:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 120 sq. mm
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.250 Amp, 25 KA, TPMCCB
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP&N
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 sq. mm
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 95 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 95 sq. mm
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of 30 A aerial fuse complete as required.
Erection of aerial fuse as required.
Supplying and fixing MV horn gap lightning arrestor as required.
Fixing of MV lightning arrestor as required.
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 10.00 metre and upto 12.00 metre
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Erection of disc/ pin insulator for 11 KV over head lines as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying, installation testing and commissioning of the 100KVA Aluminium wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure.
Supplying of following sizes XLPE insulated,insulation screening with extruded semi conducting compound in combination with copper tape cores laid up inner sheath of PVC tape,galvanised flat steel strip armoured and overall PVC sheathed cable confirming to IS7098(Part-II) 1985 with latest amendments .3Cx95sqmm HT.
Supplying of following sizes GI pole confirming to IS: 2713.12 Mtr(SP-66)
Supplying of following size XLPE insulated and PVC sheathered aluminium conductor powered armour cable of 650 / 1100 V grade confirming to IS 7098 (part-I)/ 1988 with ammendments upto date as required3 x 6 sqmm
Supplying of following size XLPE insulated and PVC sheathered aluminium conductor powered armour cable of 650 / 1100 V grade confirming to IS 7098 (part-I)/ 1988 with ammendments upto date as required
Supplying and drawing of 11KV overhead high tension line through Racoon conductor on the existing pole struture with necessary binder, pin, cross arm etc. as required complete.
Payment of load security to the local APDCL authority.
HVAC (only Ducting & AHU)Ducting, Grills, Diffuser and Insulation: Supply, installation, balancing & commissioning of factory fabricated GSS Sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vames, hangers, supports etc. as per approved drawings and sepcifications of following sheet thickness complete as required.Thickness 0.63 mm sheet.
Supply, installation, testing & commissioning of Motorized (ON-OFF Type) duct mounted GI volume control duct damper with enthalpy sensor and necessary control wire (minimum 1.5 sq.mm.) for integration with AHU room.Damper
Actuator
Supply and fixing of powder coated extruded aluminium Supply Air grills with aluminium volume control dampers as per specifications.
Supply and fixing of powder coated extruded aluminium Return Air grills with louvers but without volume control dampers complete as required.
Supply, fixing, testing & commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core.
Supply, fixing, testing & commissioning of return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring and removable core.
Supply, fixing, testing & commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire Damper
Actuator
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/cu.m., with 25X25 mm G.I. Section of 1.25 mm thick at 600 mm centre to centre covered covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Supply, fixing acoustic lining on wall and ceining of AHU rooms supply air duct and plenum with 50 mm thick, density 32 kg/cu.m. resin bonded glass fibre insulation friction fixed in 610 mmX 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6 mm thick G.I. sheet U shaped channel and covered with reinforced fibre glass tissue and finished with 0.8 mm perforated aluminium sheet etc. complete as required and as per specifications.
Supplying and fixing 50 mm thick aluminium foil faced resin bonded fibre glass insulation (on duct) of density 24 kg/cu.m. or mineral wool insulation (non combustible) of density 44 kg/cu.m. after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape and covering with 0.63mm*19 mm G.I. wire mesh netting butting all joints and laced with G.I. wire complete as per specifications and as required (for indoor aplications).
Air Handling Units: Supply, installation, testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 43 +/-2 mm thick panels consisting of pre plasticized G.I. casing of thickness 1.0 mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required minimum two bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/washable synthetic type air pre filters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415± 10% volts, 50 Hz, 3 Phase AC supply suitably suitably designed for variable frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.) and industrial type thermometers (2 Nos.) at the inlet and outlet of coil, auto purge valve wherever, necessary vibration isolation arrangement etc. complete as per specification and of following capacities: 2800 CFM - 125 mm staticn pressure - 10+5+0.3 micron filter
3250 CFM - 125 mm staticn pressure - 10+5+0.3 micron filter
Supply, Installation, testing and Commissioning of Air cooled condensing Units which shall be factory assembled, weather proof casing,hermetic scroll compressor, accessories, controls with suitable size fan and motor. The complete condensing Unit suitable for 415 +/ -10 % volts, 50 Hz, 3 phase AC power supply as described below with capacitys -8.5 TR
Supply and Installation of Expansion kit - Valve, Drier, Etc
Supply and fixing in position of Copper Referigerant Piping in Set (Suction and Discharge line) duly insulated with necessary elbow, socket and fittings
Supply and Filling/Charging of the Gas - R 407/410
Supply and Installation of Temperature + RH sensor
Design, Supply, Installation, Testing & Commissioning of Electrical Panel which consists of incomer MPCB/MCCB, contactors, DOL / Star-Delta starter, relays, push button (On/Off/Reset) , indicating lamps (Start/Stop/Trip), Controls for Heater, outgoing MCBs for Condesnsing Units, etc as per suitable/recommended KW of AHU motor
Supply & Installation of XLPE, extruded PVC type, galvanized steel strip, 1100 V grade Copper/Aluminium armored Power/Control Cables with lugs, glands, etc.
Supply & Installation of Cable tray of Suitable/Recommended Size
Supply & Installation of Fresh Air cowl with bird screen
MS structure & fabrication work for Pipe supports,Outdoor units stands & others
Commissioning, Documentation, Balancing, Valdiation of Area which include PAO, Particale Count, CFM, etc
FIRE DETECTION and ALARM SYSTEM (Conventional):Supply, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connections etc. as required.
Supply, installation, testing & commissioning of smoke detector with buitin LED and mounting base complete with all connections etc. as required.
Supply, installation, testing & commissioning of manual call box in ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supply, installation, testing & commissioning of response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Supply, installation, testing & commissioning of fire alarm sounder with facility to make announcement, mounted in ABS box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supply, installation, testing & commissioning of talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob and speaker/microphone enclosed in a M.S. (16 SWG)/A.B.S. box with break glass infront etc. complete as required.
PUBLIC ADDRESS SYSTEM:Supply, installation, testing and commissioning of 1.5/3/6W Ceiling speaker complete as required
CABLING & WIRING:Supplying and laying of 2X1.5 sq.mm fire alarm armored cable. 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface/recessed steel conduit of following pairs, cores and sizes including connections and interconnections etc. complete as required. Speaker cable single pair, 2-core, 15 sq. mm
Deep Tube Well: Boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.ordinary soil 300 mm dia
rocky soil 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia having minimum wall thickness 5.00 mm
200 mm nominal size dia having minimum wall thickness 5.40 mm
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 23.13.2 150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 23.14.2 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 23.15.2 150 mm dia
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Single phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above.5 HP STAGE 40/ 50 with MCB controlled Submersible motor pump set control panel.
Supplying fitting and fixing including necessary connection as approved by the Deptt.)of Submersible motor pump set control panel including Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) of following capacity as specified and directed by the Department. (Texmo/ Crompton Greaves/ CRI/ Aqua sub make) MCB controlled Submersible motor pump set control panel including Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.6 50 mm nominal dia Pipes
(ANALYSED ITEMS) A.C : Supply fitting fixing and commissioning of split A.C 2 ton 5 star rating inverter type with 5kva voltage stabiliser and accessories
Supply fitting fixing and commissioning of split A.C 1.5 ton 5 star rating inverter type with 4 KVA voltage stabiliser and accessories
Supply fitting fixing and commissioning of split A.C 1 ton 5 star rating inverter type with 4 KVA voltage stabiliser and accessories
INTERIOR WORKS: Supply fitting fixing installing and commissioning of Puff Panels, Prefab PUF wall and ceiling Panels 50 mm thk with powder coated galvanized steel .08mm both sides profile and accessories supply of steel profile and panel installation accessories
Supply fitting fixing installing and commissioning of Double leef door 1600 x 2400 powder coated Mortise lock door closer DG view port 350x350 h, Door handle, Hinges, Frame size 50x60 for 50mm panel
Supply fitting fixing installing and commissioning of Single leef door 1200 x 2400 powder coated door sheet thickness .8mm, frame sheet thickness 1.2 mm, DGU 300 x 400 6mm toughen glass and accessories
Supply fitting fixing installing and commissioning of DG view windows 3000x 1500. double glass view window framed in PPGI . Glass 5 mm toughned
Supply fitting fixing installing and commissioning of DG view windows 1200x 1450 double glass view window framed in PPGI . Glass 5 mm toughned
Supply fitting fixing installing and commissioning of DG view windows 1500x1450 double glass view window framed in PPGI . Glass 5 mm toughned
Supply fitting fixing installing and commissioning of DG view windows 1800 x1450 double glass view window framed in PPGI . Glass 5 mm toughned
Supply fitting fixing Installation and commissioning of Aluminium coving for wall to wall and wall to ceiling joints R50
Supply fitting fixing installation and commissioning of Cylinder manifolds with nessecery valves and fittings
Supply fitting fixing installation and commissioning installation of Auto outlet regulators
Supply fitting fixing installation and commissioning of Copper pipe of 8 mm dia with neseccery clamps etc
Supply fitting fixing installation and commissioning of toilet cubicles
Supply fitting fixing installation and commissioning of urinal partitions
Supply fitting fixing installation and commissioning of Standalone Face + biometric based attendence cum access controler with software and licence with installation of hardware and fixtures
Supply fitting fixing installation and commissioning of Network TDN IR 2 MPDome and 2MP Bullet Camera 1
Supply fitting fixing installation and commissioning of Network TDN IR Dome and Bullet Camera 1 by 3 inch CMOS 2 MP 3.6 mm IRLeds 20 mtr PoE H point , 32 channel IP camera input code decoding, HDMI / VGA video output, 4 channel synchronous realtime playback GRID interface, 2 SATA HDD 6tb 2 usb with 4tb hard disk, 3M HDMI cable , 18.5 inch monitor 6 cat cable RJ 45 connector WP PVC box 6U rack with accessories ON vIF version 2.4 conformance #d intelligent positioning and installation of hardware and fixtures
Supply fitting fixing installation and commissioning for vision pro 412, beetel c11 and 2 pair telephone wire and 1KVA offline UPS
Supply fitting fixing installation and commissioning for 30 W wall Speaker, 180 mixer Amplifier Wired Microphone, Audio cable etc
Supply fitting fixing installation and commissioning of MCM Modified Clay Material – “ MCM slate sunny - 1200 x 600 mm” of PHOMI make, as per company standard dimension, pattern, shade as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with thermal conductivity of 0.0590 W/M.K - EN12667 (2001), thermal resistance of 0.0568 M2 K/W- EN 12667(2001) and Fire Insulation -Class A-ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable MCM adhesive as per MCM adhesive chart on a smooth, levelled, and dust free substrate; and per directions of Engineer In-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect'sspecification depending on the substrate and as per the direction of Engineer in-charge. Product Thickness : Approx. 2mm
Supply fitting fixing installation and commissioning of Exide 12 V 65 Ah Battery (30 mins backup/IT load) along with Battery Rack and interlink cable
Supply fitting fixing installation and commissioning of Elnova KL60K33 ( 60 KW online UPS / 388 Batt Volt System / Inbuilt Isolation Transformer 3 phase in 3 phase out)
Supply fitting fixing installation and commissioning of clean room chairs model-Advantage LBG With Teller Base, low back (Featherlite)
Supply fitting fixing installation and commissioning of office tables Model - VMT 1275 1200x750x750 (Featherlite)
Supply fitting fixing installation and commissioning of office chairs Model - Contact Project MBGS ADJ ARM (Featherlite)
Supply fitting fixing installation and commissioning of managers table Model- VMT 1890Main Table (1800X900X750), Mobile Pedestral (400x435x640) (Featherlite)
Supply fitting fixing installation and commissioning of managers chair model Astro HB (Featherlite)
Supply fitting fixing installation and commissioning of lobby bench Model - BRUNEY METAL 7A 3 seater Perforated Metal Tendem 1980x690x825 (Featherlite)
Supply fitting fixing installation and commissioning of training conference table 3000x1200x750 with gable end and modestry panel . Table top 25mm thk pre laminated particle board finished with 2mm edge lipping. Supported 25 mm thk PLB gable ends and 18 mm thk 450 PLT modestry panels with necessary fixtures. Wire management: 300 Anodised flip up with provision to mount switches and sockets and PVC cable dump, verticle wire entry cover for wire uptakes. (Featherlite)
Supply fitting fixing installation and commissioning of training conference chair Model - AMAZE MB BLACK ML ADJ ARMS (Featherlite)
Supply installation of sofa 3 seater vModel - 238-3S (Featherlite)
Supply fitting fixing installation and commissioning of Aluminium Structural Glazing with openable glass and opeanable double door
D.G SETS : Supply fitting fixing installation and commissioning Supply installation of Liquid cooled 62.5 KVA D.G set.
Supply fitting fixing installation and commissioning of Liquid cooled 25 KVA D.G set
ELECTRICAL ITEMS : Ceiling fan (sweep-1200mm )
15 W L.E.D Lights
Exhaust fan (300mm)
Analysed amount for All LED lights
Analysed amount for LED STREET lights
Bracket and arm for street light
EPOXY FLOORING: Providing epoxy flooring with initial cleaning of concrete floor and surface preparation. Applying of Hydrochloric acid diluted with water and cleaning the same with Ammonia diluted with water. Applying of two coat epoxy with primer of 4 mm thickness.
PASS BOXES : Supply fitting fixing installation and commissioning of Dynamic Pass Box of S.S (600x600x450)
Supply fitting fixing installation and commissioning of Static Pass Box of S.S (600x600x450)
FIRE FIGHTING: Supply fitting fixing installation and commissioning Micro processor base digital display 2 Zone Fire Alarm Panel. Make-AGNI
Supply fitting fixing installation and commissioning of ABC 4KG Fire Extinguisher. Make-Atasee
Supply fitting fixing installation and commissioning of CO2 4.5KG Fire Extinguisher. Make-Atasee
(Septic Tank for Toilet Type 1) EARTHWORK IN EXCAVATION : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
PLAIN CEMENT CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
REINFORCED CEMENT CONCRETE WORKS: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
MASONARY WORK: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand)
CEMENT PLASTERING: 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.100 mm nominal dia Pipes
MANHOLE COVER: Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityL D- 2.5Circular shape 450 mm internal diameter
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimension 455X610mm and 45 cm deep for single pipe line:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
(Septic Tank for Toilet Type 2) EARTHWORK IN EXCAVATION : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
PLAIN CEMENT CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
REINFORCED CEMENT CONCRETE WORKS: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
REINFORCEMENT : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
MASONARY WORK: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand)
CEMENT PLASTERING : 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.100 mm nominal dia Pipes
MANHOLE COVER Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality:L D- 2.5Circular shape 450 mm internal diameter
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimension 455X610mm and 45 cm deep for single pipe line:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .