| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.2 LAccepted-AOC | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹49.6 L+₹3.5 L (7.51%)Rejected-Finance | L2 | Rejected-Finance Quoting Lowest Rate | |
| 3 | L3₹54.3 L+₹8.2 L (17.7%)Rejected-Finance | L3 | Rejected-Finance Quoting Lowest Rate | |
| 4 | L4₹54.9 L+₹8.8 L (19.0%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance Quoting Lowest Rate | |
| 5 | Rejected-Technical 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | - | Rejected-Technical EMD not Submitted |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
13 Nov 2021, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Construction of a 8 storied Building with provision of(G10) Storied(Electrical) Work and SITC of Substation including Ancillary works at Burdwan Medical College and Hospital SITC of AC Machine.
2021_WBPWD_348693_1
WBPWD/SEWEC /BED /NIQ-16/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
BURDWAN
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.3 L
Yes
Office of the Superintending Engineer, Western Ele
6 Feb 2026
29 Oct 2021
16 Nov 2021
29 Oct 2021
13 Nov 2021
3 Nov 2021
29 Oct 2021 - 1 Nov 2021
1 Nov 2021
Amount
Supply , Delivery, Instalation, testing & Commissioing of 4.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 48000 BTU/hr. with 2Nos. rotary compressor with R410A/R32 Refrigerant, 2nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-415V/220V-3ph/1ph-50Hz. Air-flow/per IDU:- 800CFM. Copper Condenser . The Control Circuit should be enclosed in Metal Box to prevent fire ( Make: Hitachi/Carrier/Daikin/Bluestar/Voltas/As per choice of EIC)
Supply , Delivery, Instalation, testing & Commissioing of 3.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2Nos. rotary compressor with R410A/R32 Refrigerant, 2nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM.Copper Condenser. The Control Circuit should be enclosed in Metal Box to prevent fire ( Make: Hitachi/Carrier/Daikin/Bluestar/Voltas/As per choice of EIC)
Supply , Delivery, Instalation, testing & Commissioing of 2.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 2Nos. rotary compressor with R410A/R32 Refrigerant,1no. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 800CFM.Copper Condenser . The Control Circuit should be enclosed in Metal Box to prevent fire . ( Make: Hitachi/Carrier/Daikin/Bluestar/Voltas/As per choice of EIC)
Supply , Delivery, Instalation, testing & Commissioing of 1.5 Ton capacity Hi-wall split type A.C Machine Energy / Star Rating not less than 3,having Rotary Compressor & R410A/R32 refrigarent with full Copper Condenser, warranty not less than 48 months for the Compressor . The warranty will be considered from the date of Installation and commissioning. The Control Circuit should be enclosed in Metal Box to prevent fire. ( Make: Hitachi/Carrier/Daikin/Bluestar/Voltas/As per choice of EIC)
Supply , Delivery, Instalation, testing & Commissioing of 2.0 Ton capacity Hi-Wall split type A.C Machine Energy / Star Rating not less than 3,having Rotary Compressor & R410A/R32 refregarent with full Copper Condenser, warranty not less than 48 months for the Compressor . The Control Circuit should be enclosed in Metal Box to prevent fire . ( Make: Hitachi/Carrier/Daikin/Bluestar/Voltas/As per choice of EIC)
Supply , Delivery, Instalation, testing & Commissioing of 1.5 Ton capacity window type A.C Machine having energy efficient compressor suitable for 230Volt 50HZ power supply, R410A/R32 Refrigerant Gas, star rating not less than 3,The Control Circuit should be enclosed in Metal Box to prevent fire incl. Loading & unloading charges and carrying charges. ( Make: Hitachi /Carrier/Daikin/ Bluestar/Voltas /As per choice of EIC)
Supply & Charging Refrigerant(R32/R410A)
Supply, Installation & commissioning of hard/soft copper refrigeration pipeline, complete with fittings, elbows, bends, supporting arrangement on walls (Make- Ryoku/Rajco/Mandev)
i) Suction Line (5/8" OD with 0.8 mm thick)
ii) Liquid Line (1/4" OD with 0.7 mm thick)
Supply & Fixing 9mm nitrile rubber tube Insulation on suction line & Liquid Line copper pipe of ductable split AC (Make-Accoflex)
a) Liquid Line
b) Suction Line
Control Cabling from ODU to IDU
a) 4 Core 4 sq. mm.
b) 3 Core 2.5 sq. mm.
Supply and fixing flexible canvass connection for Concealed Split air-conditioners.
Supply and fixing of Al powder coated continuous Grill (Make Premier)
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors with necessary insulation.
a) 25mm dia
b) 32mm dia
c) 40mm dia
Charges for Scaffolding arrangement incl. lifting, shifting for outdoor & indoor units of 4.0TR,3.0TR & 2.0 TR concealed Split AC
Supplying, fabrication & fixing M.S Angle of 6 mm thick of size (50 mm x 50 mm) for making Base Frame for installation of outdoor unit of 1.5 TR/2.0TR Hi Wall & Concealed split AC fabricating in Rectangular Shape incl. drilling 2 nos holes in each angle with 4 Nos. Leg & grouting the same with necessary arrangement/ onesided platform with 40mmx40mm angle &25mm patti. Area of the platform is 1.5Mtr. x 1.2Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC.(minimum load bearing capacity 120Kg/Platform
Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0 TR & 4.0TR Concealed split AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC.
Charges for drop ceiling to cover the Indoor Units made of gypsum & E Board with painting
Charges for Trap Door made of Aluminium Channel & Fire Retardant PVC Board for IDU Maintenance
JASODA REFRIGERATOR SERVICING CENTRE
BURDWAN REFRIGARATION SERVICE
Lyric International
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .