| 1 | L1₹29.2 LAccepted-AOC 14 L N Y MARKET RANJHI JABALPUR MP 482005 | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹32.5 L+₹91,934 (2.92%)Rejected-Finance AZAD NAGAR RANJHI JABALPUR MP 482010 INDEX NO E 106 JBP | JABALPUR | MADHYA PRADESH | 482010 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹32.8 L+₹1.3 L (4.13%)Rejected-Finance D 154 ADARSH NAGAR JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.0 L+₹2.5 L (7.83%)Rejected-Finance 1890 NEW SHOBHAPUR COLONY VEHICLE FACTORY ROAD JABALPUR MP 482009 | JABALPUR | MADHYA PRADESH | 482009 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹34.5 L+₹3.0 L (9.41%)Rejected-Finance 1 SANCHAR NAGAR NEAR KRISHI UPAJ MANDI DAMOH ROAD JABALPUR M P | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
2 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIRS TO ROOF SHEETING, CHAJJA, SUNKEN FLOOR SLAB, ROOF COVERING, CEILING AND CONNECTED WORKS IN AREA OF AGE B/R - I UNDER GE (WEST) JABALPUR
2022_MES_528648_1
8466/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹76,000
20 Jul 2022
4 Jun 2022
4 Jul 2022
4 Jun 2022
2 Jul 2022
18 Jun 2022
6 Jun 2022 - 16 Jun 2022
Amount
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilliate demolition complete all as specified and directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate as in chajjas,parapet & facia etc complete all as specified and as directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate in slab supported on walls,beam and column in floors, roof, landing, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Fair finish form work to sides and soffits of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams etc. complete all as specified and directed.
Formwork to chajjas, troughs and similar items including edges fair finished complete all as specified and directed.
S&F TMT bars 6mm to 8mm dia and cut to length bent to shape required, including cranking, bending and binding as in stirrups, spacers and binders etc. with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete all as specified and directed.
Demolition of cement concrete of any description and in any position complete all as specified and directed.
M&L for 25mm thick cement concret Type B-0 1:2:4 (Using 12.5mm graded stone aggregate ) to receive tile etc all as specified and directed.
M&L for 15mm thick rendering in CM (1:3) on brick or concrete surfaces in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick, finishing the surfaces with even and smooth with using extra cement complete all as specified and directed. ( Note:- WPC measured separately) complete all as specified and directed.
Supply only integral water proofing compound
M&L for Bitumen blown any grade , applied hot, two coats to concrete surfaces at the rate of 1.5Kg /sqm per coat. Including polythene film, black , 50 micron laid in floors complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding, roof kerbs PCC as in kerbs/cover fillet complete all as specified and directed.
Material & Labour for repairing sunken floors leakage by taking out existing nahani trap or floor traps carefully by digging out from its position and provision of new PVC (SWR) nahani trap 100mm dia and joining the same to existing waste pipe and ensure leak proof joints including PCC 1:5:10, Type E-2 and making good the adjoining area to match with existing floor tiles etc with PVC NT / FT, CP steel grating 100 mm dia complete all as specified & directed.
Roughening surfaces of old concrete floor/ terrace by picking incl. taking down existing detiorated / decayed tar felt PCC tiles or any type of treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. complete all as specified and directed.
Removing building materials to a distance of 100m or under, beyond the lead incl in the rates incl loading, unloading and stacking at the destination complete all as specified and directed.
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for roofs complete all as specified and directed. (a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster. (b) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces. (c) One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non wove fabric shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame. (d) Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
Cutting grooves in brick wall,75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete etc all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete etc all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming Fe 410 -W (GdeE- 250) quality etc complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming Fe 410 -W (GdeE- 250) quality etc complete all as specified and directed.
Dismantling of timber scantlings unframed 40Sq Cm and over in section, in any position complete all as specified and directed.
S&F Second class hard-wood as in scantlings and clean sawn timber framed and fixed etc complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated,etc) sheets in roof covering complete all as specified and directed.
S&F 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
Refixing only 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering incl ridge complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed..
M&L for brick work with fly ash brick, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls with old size bricks built in cement mortar 1:4 complete all as specified and as directed.
S&F in repair 2mm thck fibre glass reinforced translucent corrugated sheeting with two side corrugation side lap fixed with coach screw and washer in roof, well etc complete all as specified and directed
M&L for 5mm thick cement plaster in cement mortar 1:3 as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) with WPC on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed (WPC shall be measured seperately (Rates included for G+2 floors, and no extra payment to be made for the same).
M&L for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of oil bound emulsion distemper over a coat of primer etc complete all as specified.
Prepration of newly plastered surfaces and applying three coat of white wash on ceiling etc all as specified.
M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of primer etc complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F in repairs 2nd class hard wood plain fillets exc 6sqcm and not exc 13 sqcm in square, rectangular or triangular in section, clean sawn, se-cured with nails or brads complete all as specified and directed.
S&F 6mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
S&F suspended false ceiling system using chicago metallic (E grid) exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length) with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as specified and directed. Make :- ARMSTRONG AND EVEREST or other equivalent as approved.
S&F, in repair, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repairs for Sheet glass ordinary quality 3 mm thick in square n exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame or wooden beading in wooden frame complete all as specified (Rates in cluded for G+2 floors, and no extra payment to be made for the same).
Supply and fix in repairs sheet glass ordinary quality 4.8 mm thick in square exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame and wooden beading in wooden frame complete all as specified.
S&F in repairs 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings joints fixed to walls complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings ljoits fixed to walls complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) bends any radius complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) bends any radius complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed.
S&F in repairs 110 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Vitriefied ceramic tiles 10mm thick DARK SHADE(square/rectangular) polished area of each tiles not exceeding 0.36 sqm including 15mm thick screed bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile complete all as specified.
M&L for Vitriefied ceramic tiles 10mm thick LIGHT SHADE(square/rectangular) polished area of each tiles not exceeding 0.36 sqm including 15mm thick screed bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile complete all as specified.
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick area of each tile exceedeing 0.18 sqm but n.exc 0.38 sqm (600x600), in floors, set and jointed in neat cement slurry and pointed in white cement fixed over and including 15 mm thick screed bed in CM (1:6) etc complete all as specified and directed.
M&L for non skid ceramic coloured joint free tiles 7 to 8 mm thick area of each tile exceedeing 0.18 sqm but n.exc 0.38 sqm (600x600), as in vertical surfaces such as skirting / dado set and jointed in neat cement slurry and pointed in white cement fixed over and including 10 mm thick backing in CM (1:4) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceedeing 0.11 sqm but n.exc 0.18 sqm, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 15 mm thick screed bed in CM (1:6) etc complete all as specified and directed.
Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 10mm thick rendering in CM 1:4 etc complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (Padestal pattern) white excluding fixing bolts, flushing cistern and flush pipe with and incl 'P' or 'S' trap and making good to floor to match with existing all as specified and directed.
S&F in repair vitreous China squatting pan of pattern Orissa Pattern , size 580 x440 mm white with P or S trap , front or backinlet and integral foot rests any pattertn (excl flushing cistern and flush pipe) complete incl provn of lime concrete bedding connection to flush pipe , trap etc & making good complete all as specified and directed.
S & F in repair Low density polyethylene (HDPE) 40mm pipes of pressure rating 6kgf/sq cm complete all as specified and directed.
S&F in repairs steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F in repairs steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F in repairs steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
M&L for disconnecting existing tanks of 250 to 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed
M&L for disconnecting existing tanks of 500 to 1000ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed
B G PANDEY AND BROTHERS
RP ANAND
M/S A K MUKHERJEE
Kirti Chandeliya and Assosicates
KRD ASSOCIATE
kamakshi construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .