| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAccepted-AOC | ₹3.8 Cr | L1 | Accepted-AOC due to L1 |
| 2 | L2₹4.4 Cr+₹65.4 L (17.2%)Rejected-AOC 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | ₹4.4 Cr+₹65.4 L (17.2%) | L2 | Rejected-AOC due to L2 |
| 3 | Not Admitted-Fee/PreQual/Technical VPO JAGRAM BASS TEHSIL BADHRA DISTT CH DADRI 127308 | JAGRAM BASS | CHARKHI DADRI | HARYANA | 127308 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹3.9 Cr
EMD Value
₹7.9 L
Closing Date
7 Sept 2023, 10:00 amClosed
PRADEEP KUMAR KUMAR
EE PHE Division No. 1 Nuh (P)
Providing and installation of Electro Magnetic Flow Meters with RTU and water MAP system for data monitoring at outlet points of various Boosting stations in Rural areas and maintenance
2023_HRY_305508_1
2023E1793A90 2938 4794 91B7 D376B743316A560PUH
Open Tender
Civil Works
Works
120 days
CHAHALKA DHULAWAT HASANPUR BAI CHANDENI KHERL
As per CBD
8 documents required · 8 mandatory
₹15,000
₹7.9 L
Yes
21 Nov 2023
22 Aug 2023
7 Sept 2023
22 Aug 2023
7 Sept 2023
22 Aug 2023
Amount
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1 :4 (1 cement : 4 coarse sand) for flow meter with RCC top slab 1 :2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 :3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design with Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates with suitable hinges and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Supply,erection,testing and commissioning of Elecro Magnetic type Flow Meters suitable to measuring discharge including cost of flanges and other material required for fixing at outlet point of 100 mm Dia pipe at Boosting stations complete with all respects
Supply,erection,testing and commissioning of Elecro Magnetic type Flow Meters suitable to measuring discharge including cost of flanges and other material required for fixing at outlet point of 150 mm at Boosting stations complete with all respect
Supply,erection,testing and commissioning of Elecro Magnetic type Flow Meters suitable to measuring discharge including cost of flanges and other material required for fixing at outlet point of 200mm dia pipe at Boosting stations complete with all respect
Supply,erection,testing and commissioning of RTU/PLC system for water MAP with intelligent nodes for data acquisition and expert assistant system to live data monitoring of flow meter on user friendly dashboard from a central point including cost of material required for fixing at outlet point of Boosting stations complete with all respects as satisfaction of Engineer in charge
Operation and Maintenance of 150 Unit of Flowmeter including RTU for 1st years after completion of work including All services
Operation and Maintenance of 150 Unit of Flowmeter including RTU for 2nd years after completion of work including All services
Operation and Maintenance of 150 Unit of Flowmeter including RTU for 3rd years after completion of work including All services
M/S SHREE BALAJI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .