| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-AOC 9 203 KATTUKOTTAI MALAIVEPPANKUTTAI POST NAMAKKAL TAMIL NADU 637404 | NAMAKKAL | NAMAKKAL | TAMIL NADU | 637404 | ₹4.3 Cr | L1 | Accepted-AOC LOWEST L1 TENDER |
| 2 | L2₹4.4 Cr+₹15.6 L (3.66%)Rejected-AOC | ₹4.4 Cr+₹15.6 L (3.66%) | L2 | Rejected-AOC REJECTED |
| 3 | Rejected-Technical ERODE | - | - | Rejected-Technical The contraactor has not completed work of similar nature namely RCC Wrehouse or buildings, The contractor has not produced continous EC from the solvency obtained date to Tender date, The contractor has not furnished the D3 Form |
| 4 | Rejected-Technical NO 64 PERUMALPALAYAM PUDHUR THALAVAIPETTAI POST BHAVANI TALUK ERODE DISTRICT 638 312 | ERODE | TAMIL NADU | 638312 | - | - | Rejected-Technical According to Tender requirements, In adequate machinery and Tools. The tenderer has only 500 Nos of Centering sheets copared to tender requirements of 1500 sq.M |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
28 Jul 2023, 3:00 pmClosed
General Manager
TNMSC, 417, Pantheon Road, Egmore, Chennai 8
Tender for Construction of Additional Drug warehouse at Madurai
2023_TNMSC_332183_1
002/TNMSC/CIVIL/2023 DT.26.06.23
Open Tender
Civil Works - Buildings
Lump-sum
360 days
Madurai
Please refer Tender Documents
7 documents required · 7 mandatory
₹0
₹2.7 L
3 Jun 2025
28 Jun 2023
28 Jul 2023
28 Jun 2023
28 Jul 2023
14 Jul 2023
Amount
Earth work excavation (narrow) for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Filling the basement with excavated earth free from clay in layers of not more than 15cm thick well rammed watered and consolidated complete complying with standard specification.
Filling the basement with gravel free from clay in layers not more than 15cm thick well rammed watered and consolidated complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling M sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring and laid in layers of not more than 15 cm thick and rendering the top surface rough to receive the floor finish and compacted etc., complete complying with standard specification and as directed by the departmental officers.
Brick work in following Cement Mortar using best quality Fly ash Bricks 230 *110*75 for foundation and basement including curing, etc., complete complying with standard specifiction..
For foundation and basement
For Ground floor
For First floor
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as R.C.C. floor slab, roof slab, beams, lintels,bed blocks,landing slab,waist slab,portico slabs and beams,etc
For Column footings, plinth beam bed blocks templates staircase, steps piers raft beam raft slab etc.,
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position , standardised concrete mix M-25 grade in accordance using 20mm with IS:456-2000 ,and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350kg/ms and maximum water cement ratio of 0.5, including admixture (plasticiser/super plasticiser) in recommended proportions as per IS:9103 to accelerate , retard setting of concrete , improve workability without impairing strength and durability with about 5 cu.m 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cu.m) 5156 kg of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7676kg of sand but excluding cost of reinforcement grill and fabricating charges , centering and shuttering and also including laying , vibrating with mechanical vibrators, finishing , curing, etc. and providing fixtures like fan clamps in the RCC floor/roof slabes wherever necessary without claiming extra , etc complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No seperate payment will be made by the department for the excess usage of materials).
Foundation and basement
For Ground floor
For First floor upto
Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/mᶾ and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Foundation and basement
Cement Concrete 1:3:6 (One Cement, Three sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three Sand and Six hard broken stone jelly). Dummy columns should be at least 1 metre height)
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Brick partition walls of 11.50cm thickness using best quality Fly ash Bricks 230 *110*75 in Cement Mortar 1:6(One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Paving the floor with kota stone slab of size 600 x 600 of 18 / 20mm (un-polished) in all floors laid in of cement mortor 1:3 (one cement three sand), 20mm thick and pointed with colour cement neatly including polishing with polishing stone and oxalic acid etc., so as to perfectly smooth and glossy and including hire charges for polishing machine and power consumption charges etc. The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Supplying and fixing over the hard base with Anti-skid tiles (STEP) 300x300x18 mm thick of any colour with cm 1:3, 20 mm thick and pointed with same colour cement added with colour pigments etc., complete including curing, cutting, wastages etc.,
Providing & Fixing Staircase hand rail made out of 50.80mm dia stainless steel tube of 1.60mm thick at required locations to a height of 1000mm from finished floor level, welded to 38.10mm dia S.S.tube post of 1.60mm thick as vertical at 1m centre to centre with 3 nos of 25.40 mm dia horizontal S.S.tubes of 1.60mm thick in between as per details shown in the drawing and as directed. Rate shall include for grouting into concrete with necessary supporting arrangements in hand rail vertical and in floor, welding the base cup of post into slab reinforcement polishing.buffing and protecting the hand rail surface etc.complete as directed by the departmental officers.
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the roof with one course of pressed tiles of size 23x23x2cm of approved quality laid in cement mortar 1:3, 20mm thick mixed with 2% water proofing compound (conforming to Indian Standard specification) by weight of cement used and pointed with the same mortar including mixing of red oxide etc. complete.
Supplying and fixing in position best approved quality of PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 160 mm dia
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Supplying and fixing in position of aluminium anodized colour matt finish Louvered Ventilator. The outer frame will be 62x382mm @ 1.17 kg/m and the louvers with moving arrangements will be made with aluminium channel of size 60x30x4mm @ 1.27 kg/m with necessary glass panes for louvers 4mm thick Aluminium Clips, including all materials, labour & power consumption charges required for fabrication if necessary chipping dismantling making holes in RCC columns, beams or masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing etc., complete. The aluminium surfaces is to be anodized with matt finish under electrically controlled condition in accordance with ISI 1868/1962 of anodic film thickness of not less than 15 (fifteen) microns for all section. The Executive Engineer should be approved all materials before fixing in position as directed.
Manufacturing, supplying and fixing in position steel ventilators, N type ventilators using Z sections, J sections for centre mullion, 12mm square rods as per design and providing circular openings for exhaust fans including supplying and fixing 3mm thick coloured glass with necessary weldmesh between the horizontal opening in N type ventilators complete.
Providing and fixing in position M.S Rolling shutters of approved make made of required size 18 gauges MS locks interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangement for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long unispring 2 and MS top cover of required thickness for rolling shutters.
Manufacturing, supplying and fixing M.S. grill for Windows and Gate etc, including priming coat
Fabrication, supplying and fixing of Steel door made out of 40x40x6mm M.S. angle section @ 3.50 kg/m used for outer frame and shutter made out of 35 x 35 x 5 mm M.S. angle section @ 2.60 kg/m with necessary stiffener 32 x 6mm. A tie bar of 32 x 6mm M.S. flat is used in bottom of frame in order to avoid twisting of door frame. The shutter and provided with required locking facilities and M.S. furniture fittings such as hold fast, hinge, tower bolt and aldrop. The cost is inclusive of cutting the members, welding, grinding, one coat of priming coat using best approved quality red oxide primer, dismantling of walls/ concrete if necessary, fixing and finishing the dismantled portion or original condition etc., complete complying with standard specification and as directed by the departmental officers.
Painting New Iron works for grills and steel balustrades etc. with two coats of approved quality and colour of synthetic enamel paint over existing priming coat etc. including scrapping and preparation of surface and cost of brush, scaffolding and complying with standard specification (The quality and colour of paint to be approved by EE before use on works).
Providing Anti – termite treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 part I to IV in stage to suit the progress of work consist as per the detailed specification as below (Measurements taken for the plinth area for the purpose of payment) including braking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport & storing etc., complete and as directed by the departmental officers.(The chemical should be got approved by Executive Engineer before use on work). Stage -1 : Spraying Anti –termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation. Stage-2 : Spraying Anti –termite chemical solution to the grade beam level, spraying has to done for to grade beam brick masonry contact with the back fill earth. Stage-3 : Spraying Anti –termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out and sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring throughout. Stage -4 : Spraying Anti –termite chemical solution alround building outside by making holes with crow bar before laying plinth protection and the holes to be close after the treatment.
supplying and providing guard rail at loading &unloading platform with 100x45mm channel and 100x37.5 mm seasoned country wood fixed over MS channel
Damp proof course with Cement Mortar 1:4 ( One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc.complete complying with standard specification.
Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed
Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed
Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed.
MNM CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .