Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.4 LAccepted-AOC HOUSE NO 165 A VILLAGE POST MORTA DISTT GHAZIABAD U P PIN 201003 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201003 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹30.5 L+₹2,358.50 (0.08%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹31.1 L+₹64,321 (2.11%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹35.3 L+₹4.9 L (16.0%)Rejected-Finance | L-4 | Rejected-Finance L-4 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
22 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
GE (AF) FARIDABAD
ADDITION/ALTERATION OF ARMOURY AT AF STN CHANDINAGAR
2022_MES_547661_1
GE (FBD)/AF-38/2022-2023
Open Tender
Civil Works
Item Rate
180 days
CHANDINAGAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹78,000
Yes
21 Nov 2022
25 Aug 2022
24 Sept 2022
25 Aug 2022
22 Sept 2022
8 Sept 2022
25 Aug 2022 - 1 Sept 2022
Amount
Taking down chowkats or frame with shutters (without taking off shuttters from frames) size exc 1.5 Sqm but not exc 4 sqm each each and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frame with shutters (without taking off shuttters from frames) size n .exc 1.5 Sqm and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc complete all as specified and directed by Engineer-in-Charge.
Surface dressing n.exc 15 cm deep and getting out in loose / soft soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep for foundation etc. not exc 10 Sqm on plan getting out as in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 (using 40mm graded aggregate ) as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M25 design mix using (20mm graded stone agg) for fdn, bases of col, plinth beam etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design Mix using 20 mm gradded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.
M&L RCC M-25 (using 20 mm aggregate ) for chajjas complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design mix using 20 mm graded stone agg. As in roof slab supported on wall / beams complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design mix using 20 mm graded stone agg. as in beams ,cantilevers ,lintels over 1.50 mtr span complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sofits or suspendedb slabs such as roof slabs, floor slab, landing and similar work not exc 200mm thick complete all as specified and directed complete all as specified and directed by Engineer-in-Charge.
All as per item No 14 above but for chajjas complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides of pillars, posts, struts, piers, columns, and stanchions square/recatangular/polygun on plan for rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for TMT Bars 10 mm dia & over, cut to length bent to shape, reuired, including cranking bending and fixing to beam slab, chajja for faciliating guniting complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 8 mm dia cut to length, bent to shape required including cranking bending, spirally for hooping end and binding with and incl mild steel wire (annealed) not less than .9mm dia or securing with clips quality confirming Fe 410S or Fe-410O complete all as specified and directed by Engineer-in-Charge.
All as per item No 19 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
M/L for old size Brickwork with subclass `B' bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Providing, cement concrete type B-1 (1:2:4) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 15 mm thick in CM 1:6 on fair faces of brick or concrete surfaces of walls, facia etc to be finished even and smooth (w/o using extra cement) complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick cement plastering on fair faces brick or concrete surfaces in CM 1:4 finished even and smooth without using extra cement ccomplete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing newly plastered surfaces and applying two coats of distemper oil emulsion including priming plastered and other surfaces with chalk whitening preparatory to distempering on surfaces of walls complete all as specified and directed by Engineer-in-Charge.
S/F 125x60mm size pressed steel frame for doors with one or more rebates including necessary fixing lugs,hinges,lockers,strike plates etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for plain framed, panelled shutter (2nd class HW rail and style 35 mm thick, two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated fixing to frame/chowkhat complete all as specified and directed by Engineer-in-Charge.
S&F butt hinges medium weight cold rolled mild steel 100mm size complete all as specified and directed by Engineer-in-Charge.
S&F in aluminium anodised barrel tower bolts 200mm long of extruded section fixedcomplete all as specified and directed by Engineer-in-Charge.
S/F Aluminium alloy, anodised, 250 mm size sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor overall length of cover 140 mm complete all as specified and directed by Engineer-in-Charge.
M&L for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 3mm thick sheet glass ordinary quality and glazing with oil putty in squares fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F framed work such as grills, gratings etc. With ends for bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con-forming to Fe-290. Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Hard core of gauge not exc 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface with broken/stone/boulers complete all as specified and directed by Engineer-in-Charge.
M/L for Sand filling under floors including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 (40mm graded stone aggregate ) for sub base 75mm thick complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut Kota stone slabs flooring 18 to 22 mm thick over 20 mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L 5 mm thick plasteringin CM 1:3 over ceiling and finished the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour preparation of newly plastered ceiling surfaces of any description and apply three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick plastering in CM 1:4 on RCC roof slab, finish even and smooth for receive water proofing treatment using WPC @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only integral water proofing compound confirming to IS 2645 – 1975.Make-Impermo, STP No. 1 complete all as specified and directed by Engineer-in-Charge.
M/L for preparation of the plastered roof surfaces and fix the APP polymeric water proofing membrane of minimum 4 mm thickness & weighing not less than 3.0 kg / sqm of make : IWL, STP, BENGAL BITUMEN as approved by GE, black finished reinforced with non-woven ployster 160 gsm matt with a thermofusible finish laid over primer conforming to IS:3384-1965 @ 0.5 kg/sqm and thereafter apply compitable hot blown bitumen 85/25 @ 1.20 kg/sqm torching overlaps with a propane or a butane gas torch with a overlap of 75 mm at the sides and 100 mm at the end sealing complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:3:6 using 20 mm graded stone aggregate as in plinth protection finished even & smooth w / o using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for 100 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in pavement finished even and fair complete all as specified and directed by Engineer-in-Charge.
M&L for 60 mm thick precast cement concrete coloured interlocking tiles of grade M-35 any shape and size confirming to IS 15658-2006 with grey cement and pigment in floors / pavements incl 30 mm thick sand cushioning complete all as specified and directed by Engineer-in-Charge.
Supply and install hi wall split units (1.5 ton) indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 ton complete all as specified and directed by Engineer-in-Charge.
Supply and install hi wall split units (2 ton) indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity 2 ton complete all as specified and directed by Engineer-In-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed by Engineer-in-Charge.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 amps MCB complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x2.5 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with two single core, 6 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x4 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F SPN MCB distribution board 8 Way IP 42 Double door (Power shell) steel sheet Phosphatised powder coated with Din rail removable busbar shrouded neutral link with conditional short circuit rating of 5 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 63 amp SPN in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 5 to 32 amp SP in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
S&F TPN vertical DB 8 way IP 42 Double door suitable to accomodate 3/4 pole MCCB as incomer SP/DP/TP outgoing MCB,s 8 way (Power Shell) sheet steel enclosure with detachable gland plates for flush powder coated with Din rail removable busbar shrouded neutral link with conditional short circuit rating of 10 kA rating complete all as specified and directed by Engineer-in-Charge.
36SHRI RADHEY ASSOCIATES
akhil enterprises
High Tech Metal India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .