Loading…
Loading…
Tender Value
₹13.8 L
EMD Value
₹2.1 L
Closing Date
9 Jul 2026, 6:00 pm
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIRS TO WATER SUPPLY PUMP SETS, PUMP HOUSES AND CONNECTED ITEMS AGAINST BER UNDER GE (NW), NAVY NAGAR, COLABA, MUMBAI
2026_MES_771959_1
8293/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
270 days
GE (NW) Navy Nagar
Class B
Category a (ii)
7 documents required · 7 mandatory
₹1,000
GE (NW) Navy Nagar
₹2.1 L
Yes
13 Jun 2026
13 Jun 2026
10 Jul 2026
13 Jun 2026
9 Jul 2026
4 Jul 2026
13 Jun 2026 - 13 Jun 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: COMMANDER WORKS ENGINEER (NAVAL WORKS) MUMBAI
Name of Work : SPECIAL REPAIRS TO WATER SUPPLY PUMP SETS, PUMP HOUSES AND CONNECTED ITEMS AGAINST BER UNDER GE (NW), NAVY NAGAR, COLABA, MUMBAI
Contract No: 8293/CWE (NW) MUMBAI/E8
Sl. No. Item Code / Make Quantity Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Material and labour for dismantling and taking out unserviceable centrifugal pump set of 75 HP capacity from pump house, including disconnection of electrical and mechanical connections, removal from foundation, loading, transportation and depositing at AGE (E/M) store yard, complete all as specified and directed by Engineer-in-Charge. 5 Each 0.0000 Excess(+) Full Conversion INR
2 Supply, installation, testing and commissioning of electrically driven centrifugal pump set of 2400 LPM discharge at 70 metre head, complete with all accessories, foundation and allied works, as specified and directed by Engineer-in-Charge. The pump set shall comprise the following: (A) Pump: Horizontal split casing centrifugal pump Capacity: 2400 LPM at 70 m head Pump casing: Cast Iron Impeller: Bronze, enclosed type Shaft: Stainless steel Gland packing and sealing arrangement Conforming to IS 1520 (B) Motor: Squirrel cage induction motor, IE-3 efficiency Rating suitable for above pump duty Speed: 1500 RPM (synchronous) Voltage: 415 V, 3 Phase, 50 Hz AC Enclosure: TEFC, IP-55 Mounting: Horizontal, foot mounted Insulation: Class ‘F’ Conforming to IS 325 2 Each 0.0000 Excess(+) Full Conversion INR
2.01 (C) Base Frame & Accessories: MS fabricated common base plate Flexible coupling with guard Pressure gauge 150 mm dia, range up to 6 kg/cm², accuracy ±2% Foundation bolts, nuts, washers, shims etc. (D) Foundation & Installation: Cement concrete foundation of suitable size Anti-vibration pads Alignment, grouting and fixing complete Painting of suction and delivery lines (colour coding as directed) (E) Painting: One coat of red oxide primer (IS approved) Two coats of synthetic enamel paint (IS approved) (F) Documentation & Testing: Submission of pump performance curves and efficiency data Testing and commissioning complete (G) Approved Makes: Pump: Kirloskar / Mather & Platt / Jyoti Pumps Motor: Kirloskar / Crompton Greaves / Mather & Platt. 0.0000 Excess(+) Full Conversion INR
3 Ditto as per Item No. 2 above, but pump capacity 2400 LPM at 90 metre head, complete all as specified and directed by Engieer-in-Charge. 1 Each 0.0000 Excess(+) Full Conversion INR
4 Ditto all as per Item No. 2 above, but pump capacity 1600 LPM at 70 metre head,complete all as specified and directed by Engieer-in-Charge. 2 Each 0.0000 Excess(+) Full Conversion INR
5 Supply and laying in repair of 1 core, 50 sqmm copper conductor, unarmoured, PVC insulated and sheathed power/control cable from motor starter panel to motor, laid through HDPE pipe in ground (HDPE pipe and excavation measured separately), including dressing, routing, supplying and fixing of copper lugs, glands (if required), nuts, bolts and washers, complete with crimping, termination at both ends, ferruling, identification, testing for continuity and insulation resistance, complete all as specified and directed by Engineer-in-Charge. 200 RM 0.0000 Excess(+) Full Conversion INR
5.01 Ditto all as Item No. 5 above, but cable size shall be 1 core, 16 sqmm copper conductor,complete all as specified and directed by Engineer-in-Charge. 150 RM 0.0000 Excess(+) Full Conversion INR
6 Supplying and fixing in repairs, Earthing complete with galvanised steel earth plate electrode of size 600 mm × 600 mm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, including providing and fixing galvanised iron strip 25 mm × 4 mm as earthing lead, connections by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, complete all as shown in Electrical Plate No. 3 and as specified or indicated, including testing on completion complete all as specified and directed by Engineer-in-Charge. 14 Each 0.0000 Excess(+) Full Conversion INR
7 Supplying and fixing in repairs, earth continuity conductor or main earthing lead, using galvanised iron strip 25 mm × 4 mm, fixed to wall on batten or in recess/chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated position for loop earthing, etc. as required, including bending, cutting, jointing, and fixing with all necessary accessories, and making good all work disturbed, complete all as specified and directed. 400 RM 0.0000 Excess(+) Full Conversion INR
8 Materials and Labour in repair for High density poly-ethylene pipes (HDPE) of pressure rating 6 kgf/cm², for 50 mm bore, laid in trenches, including all pipe fittings (such as ends, elbows, unions, tees, reducing tees, adaptors, sockets, plugs, etc.), cutting, jointing, alignment, and testing of the system for leakage, complete all as specified and directed. 600 RM 0.0000 Excess(+) Full Conversion INR
9 Supply and fixing in repair of oil-filled pressure gauge of 150 mm dia with range 0–14 kg/cm², including providing and fixing of adaptor, ferrule, check nut, nipples and all necessary fittings, making necessary alterations in existing MS/CI pipeline for tapping wherever required, complete all as specified and directed by Engineer-in-Charge. 5 Nos 0.0000 Excess(+) Full Conversion INR
10 Supply, installation, testing and commissioning of indoor type LT distribution panel in replacement of existing panel of suitable size, CPRI type tested, weather and vermin proof, fabricated from 2 mm thick CRCA sheet, factory assembled, cubicle pattern, modular and compartmentalized construction, with front and rear doors having locking arrangement, floor mounted free standing type, complete with duly powder coated finish, 400 Amps copper bus bars with epoxy insulated coating and cable alleys, fully prewired with ferruling, including interconnection from SCADA PLC panel to LT panel and all control wiring, comprising of 415 V, 4 pole, 250 Amps MCCB with thermal magnetic protection (thermal adjustable 0.8–1 In, magnetic adjustable 5–10 In, breaking capacity 50 kA) as incomer (01 No), 415 V, 3 pole, 160 Amps MCCB with thermal magnetic protection (thermal adjustable 0.8–1 In, magnetic adjustable 5–10 In, breaking capacity 36 kA) as outgoing feeders (03 Nos), star-delta starters suitable for 60 HP to 90 HP pump sets, 415 V, 3 phase with comprehensive motor protection including programmable overload protection with RTD and thermistor inputs and constant current adaptive acceleration/deceleration for smooth operation (03 Nos including 01 standby), selector switches, push buttons, indication lamps and all necessary panel accessories, digital multifunction meters with suitable CTs and PTs (range 0–630 Amps and 0–500 Volts) (04 Nos), complete with suitable RCC foundation including shifting/removal of existing panel wherever required, testing and commissioning complete all as specified and directed by Engineer-in-Charge 1 Nos 0.0000 Excess(+) Full Conversion INR
11 Supply, installation, testing and commissioning of indoor type LT distribution panel in replacement of existing panel of suitable size, CPRI type tested, weather and vermin proof, fabricated from 2 mm thick CRCA sheet, factory assembled cubicle pattern, modular and compartmentalized construction, with front and rear doors having locking arrangement, floor mounted free standing type, complete with powder coated finish, 400 Amps copper bus bars with epoxy insulated coating and cable alleys, fully prewired with ferruling, including interconnection from SCADA PLC panel to LT panel and all control wiring, comprising of 415 V, 4 pole, 250 Amps MCCB with thermal magnetic protection (thermal adjustable 0.8–1 In, magnetic adjustable 5–10 In, breaking capacity 50 kA) as incomer (01 No), 415 V, 3 pole, 160 Amps MCCB with thermal magnetic protection (thermal adjustable 0.8–1 In, magnetic adjustable 5–10 In, breaking capacity 36 kA) as outgoing feeders (03 Nos), star-delta starters suitable for 60 HP to 90 HP pump sets, 415 V, 3 phase with comprehensive motor protection including programmable overload protection with RTD and thermistor inputs and constant current adaptive acceleration and deceleration for smooth operation (03 Nos including 01 standby), selector switches, push buttons, indication lamps and all required panel accessories, digital multifunction meters complete with suitable CTs and PTs (range 0–630 Amps and 0–500 Volts) (04 Nos), including providing suitable RCC foundation, shifting/removal of existing panel wherever required, complete with testing and commissioning, all as specified and directed by Engineer-in-Charge. 1 Nos 0.0000 Excess(+) Full Conversion INR
12 Supply and fixing in repair 150 mm Ultrasonic battery powered digital water meter (Manual reading) with onside testing arrangement, suitable for max flow of 2000m3/hr , testing complete with the following Features & benefits :- (a) Fully ecapsulated in a heavy duty enclosure with IP 68 rating. (b) No moving parts : dependable ultrasonic performance without maintenance (c) Excellent performance at all flow rates: accuracy doesnot degrade over the life of the meter. (d) NSF-61G approved. (e) Not affected by water impurity, withstand the challenges in harsh environments. (f) Low pressure drop, saves significant pumping cost. (g) 10 Years battery life. (h) Bi-directional flow, Low pressure drop, free positioning for installation. (j) Tamper proof design (k) AMR/AMI ready with encoder pulse, 4-20mA, M-Bus, Modbus, BACnet, long range RF or GPRS wireless (k) Data Logger with 700 daily totals and 24 monthly totals. (l) 2 years basic warranty and 08 years extended warranty (m) IP 68 water proof under submerged or flooding conditions (m) Large LCD , 9 digit display. Make :- M/S. SPIRE model No. 280W-C14-DN450-1-IN or technocommercial equivalent Note :- 1. The rate includes the cutting/welding , fittings as required at site in 150 mm existing DI pipieline through BMC staff without interruption of regular water supply and make it leak proof in ground. 2. The work shall be carried out through BMC, the contractor shall liaison with BMC and fees for installation has been paid to them is under the scope of the contractor. 3. No extra payments shall be paid to the contractor, any left out items/misc items required for the installation are borne in the item rate only. 3 Each 0.0000 Excess(+) Full Conversion INR
13 Ditto all as per item No 12 but of size 300 mm all as specified and directed by Engineer-in-Charge. 2 Each 0.0000 Excess(+) Full Conversion INR
14 Supplying and fixing in repairs, galvanised steel water tubing, Medium Grade, complete with all tube fittings (such as bends, elbows, tees, short pieces, connectors, back-nuts, diminishing pieces, caps, plugs and unions, etc.), for 25 mm bore, fixed complete to walls and ceilings or in shafts, for portion of building from thirteen to sixteen storeys, including taking down existing steel tubing and connections and removal to Store, including cutting through walls/floors and making good all disturbed work to match the existing, jointing and testing of the system, complete all as specified and directed. 30 RM 0.0000 Excess(+) Full Conversion INR
14.01 Ditto all as per item No 14 but size 40 mm bore all as specified and directed by Engineer-in-Charge. 50 RM 0.0000 Excess(+) Full Conversion INR
14.02 Ditto all as per item No 14 but size 50 mm bore all as specified and directed by Engineer-in-Charge. 50 RM 0.0000 Excess(+) Full Conversion INR
14.03 Ditto all as per item No 14 but size 80 mm bore all as specified and directed by Engineer-in-Charge. 100 RM 0.0000 Excess(+) Full Conversion INR
15 Supplying and fixing in repairs, Gun-metal gate valves(ISI Marked), with iron wheel head, screwed both ends for iron pipe, for 40 mm bore, including all necessary tube fittings (such as unions, sockets, etc.) and jointing, including testing of the system, complete all as specified and directed. 4 Each 0.0000 Excess(+) Full Conversion INR
15.01 Ditto all as per item No 15 but of size 50 mm bore,complete all as specified and directed by Engineer-in-Charge. 5 Each 0.0000 Excess(+) Full Conversion INR
15.02 Ditto all as per item No 15 but of size 80 mm bore,complete all as specified and directed by Engineer-in-Charge. 4 Each 0.0000 Excess(+) Full Conversion INR
15.03 Ditto all as per item No 15 but of size 25 mm bore,complete all as specified and directed by Engineer-in-Charge. 4 Each 0.0000 Excess(+) Full Conversion INR
16 M & L for Cutting existing DI pipes and reducing for insertion of DI fittings to required length in position for following sizes :- Note :- Pipe fittings used shall be measured and paid under relevant items of schedule 'A' remaining items like welding and other items required shall be deemed to be included in the item rate 0.0000 Excess(+) Full Conversion INR
16.01 300 mm bore 5 Each 0.0000 Excess(+) Full Conversion INR
16.02 150 mm bore 6 Each 0.0000 Excess(+) Full Conversion INR
16.03 100 mm bore 4 Each 0.0000 Excess(+) Full Conversion INR
17 Materials and Labour for run lead joints, using pig lead, in repairs, including burning out existing lead joints in position and removal of recovered lead , and including draining the system as required; also including excavating in trenches for pipes and getting out in all kinds of soil, returning, filling in, spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed for following sizes of pipes: 0.0000 Excess(+) Full Conversion INR
17.01 300 mm bore 2 Each 0.0000 Excess(+) Full Conversion INR
17.02 150 mm bore 2 Each 0.0000 Excess(+) Full Conversion INR
17.03 100 mm bore 2 Each 0.0000 Excess(+) Full Conversion INR
18 Supply and laying in repair of spigot and socket ductile iron water tubing,class K-9, 300 mm dia cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed. 100 RM 0.0000 Excess(+) Full Conversion INR
19 Ditto all as per item no 18.00 above but of size 150 mm,complete all as specified and directed by Engineer-in-Charge. 300 RM 0.0000 Excess(+) Full Conversion INR
20 Ditto all as per item no 18.00 above but of size 100 mm,complete all as specified and directed by Engineer-in-Charge. 200 RM 0.0000 Excess(+) Full Conversion INR
21 Supplying and fixing in repairs, MS ERW pipe, Heavy Grade, conforming to IS 1239, for 100 mm bore, complete with all necessary tube fittings (such as bends, elbows, tees, short pieces, connectors, back-nuts, diminishing pieces, caps, plugs and unions, etc.), including cutting, threading, welding, jointing and fixing in position, providing and fixing supporting brackets or clamps, including preparation of surfaces and applying one coat of red oxide primer and two coats of synthetic enamel paint (ordinary tint), and including bituminous wrapping and protective coating conforming to IS 15337:2003 for portions laid underground, and making good all disturbed work to match the existing, complete all as specified and directed. Note: Rate shall be deemed to include bituminous wrapping and protective coating conforming to IS 15337:2003 for 100 mm NB pipes wherever laid underground, including all materials, labour and application. 150 RM 0.0000 Excess(+) Full Conversion INR
22 Ditto as per item no 21.00 above but of size 150 mm,complete all as specified and directed by Engineer-in-Charge. 100 RM 0.0000 Excess(+) Full Conversion INR
23 Ditto as per item no 21.00 above but of size 80 mm,complete all as specified and directed by Engineer-in-Charge. 40 RM 0.0000 Excess(+) Full Conversion INR
24 Supplying and fixing in repairs, Sluice Valve, Class PN 1.6, both ends flanged, for 300 mm bore, complete with all necessary jointing materials (such as rubber or fibre board gaskets, bolts, nuts, and washers, etc.), including jointing and testing of the system, complete all as specified and directed. 3 Each 0.0000 Excess(+) Full Conversion INR
25 Ditto as per item no 24.00 above but of size 150 mm,complete all as specified and directed by Engineer-in-Charge. 6 Each 0.0000 Excess(+) Full Conversion INR
26 Ditto as per item no 24.00 above but of size 100 mm,complete all as specified and directed by Engineer-in-Charge. 4 Each 0.0000 Excess(+) Full Conversion INR
27 Ditto as per item no 24.00 above but of size 80 mm,complete all as specified and directed by Engineer-in-Charge. 4 Each 0.0000 Excess(+) Full Conversion INR
28 Supplying and fixing in repairs, Non-return valve (Non-return sluice valve) ISI Marked, both ends flanged, for 300 mm bore, complete with all necessary jointing materials (such as rubber or fibre board gaskets, bolts, nuts, and washers, etc.), including jointing and testing of the system, complete all as specified and directed. 2 Each 0.0000 Excess(+) Full Conversion INR
29 Ditto as per item no 28.00 above but of size 150 mm,complete all as specified and directed by Engineer-in-Charge. 4 Each 0.0000 Excess(+) Full Conversion INR
30 Ditto as per item no 28.00 above but of size 100 mm,complete all as specified and directed by Engineer-in-Charge. 4 Each 0.0000 Excess(+) Full Conversion INR
31 Ditto as per item no 28.00 above but of size 80 mm,complete all as specified and directed by Engineer-in-Charge. 2 Each 0.0000 Excess(+) Full Conversion INR
32 Supply and fixing in repairs, Installation, Testing & Commissioning of Motor Actuated Butterfly Valve (ISI MARKED (with wheel for manual operation) consisiting of suitable single phase Actuator and ball valve of size 100 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure complete all as specified and directed. SpecificationSupply and fixing eatures Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Material of Ball: Stainless Steel Limit Switches : 02 Nos.For open and close status Mounting :Direct on valve Model : QT 5 8 Each 0.0000 Excess(+) Full Conversion INR
33 Ditto as per item No 32 but of size 80 mm,complete all as specified and directed by Engineer-in-Charge. 2 Each 0.0000 Excess(+) Full Conversion INR
34 Ditto as per item No 32 but of size 50 mm,complete all as specified and directed by Engineer-in-Charge. 35 Each 0.0000 Excess(+) Full Conversion INR
35 Supply and fixing in repairs, Installation, Testing & Commissioning of Motor Actuated Butterfly Valve (with wheel for manual operation) consisiting of suitable single phase Actuator and ball valve of size 150 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure complete all as specified and directed. SpecificationSupply and fixing eatures Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Material of Ball: Stainless Steel Limit Switches : 02 Nos.For open and close status Mounting :Direct on valve Model : QT 10 3 Each 0.0000 Excess(+) Full Conversion INR
36 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, in hard/dense soil, complete all as specified and directed. 195.1 Cum 0.0000 Excess(+) Full Conversion INR
37 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified. 181.18 Cum 0.0000 Excess(+) Full Conversion INR
38 Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed, complete all as specified. 13.92 Cum 0.0000 Excess(+) Full Conversion INR
39 Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), including removal of rubbish and including removing debris off MD premises, complete all as specified 20 Cum 0.0000 Excess(+) Full Conversion INR
40 Materials and Labour for cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete, including finishing exposed surfaces even and fair without using extra cement, complete all as specified. 20 Cum 0.0000 Excess(+) Full Conversion INR
41 M&L for construction of brick masonry valve chamber in repair of internal size 1.20 m × 1.20 m × 1.20 m, with top 0.30 m above ground level, suitable for fixing sluice valve, including 150 mm thick PCC (1:4:8) type D-2 foundation over 150 mm thick hardcore of broken stone, 230 mm thick brick masonry in cement mortar 1:4, 15 mm thick internal and external plaster including top surface in cement mortar 1:3 finished smooth and even without extra cement, providing and fixing 8 mm thick MS plate cover over 50 mm × 50 mm × 6 mm MS angle frame embedded in PCC (1:2:4) type B-1 coping, with rectangular hinged opening of size 150 mm × 100 mm with locking arrangement, holdfasts etc., applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces, including excavation, earthwork in any type of soil and disposal of surplus/debris outside MD land, complete all as specified and directed by Engineer-in-Charge. 10 Each 0.0000 Excess(+) Full Conversion INR
42 Supply and fixing in repair of 4 core × 1.5 sq mm copper conductor, PVC insulated and PVC sheathed, armoured, FRLS cable, laid on wall or in trench, including dressing, routing, fixing with suitable clamps/saddles, providing and fixing glands, lugs, ferruling, termination at both ends, testing for continuity and insulation resistance, complete all as specified and directed by Engineer-in-Charge. 300 RM 0.0000 Excess(+) Full Conversion INR
43 Supply and fixing in repair of 6 core × 1.5 sq mm copper conductor, PVC insulated and PVC sheathed, armoured, FRLS cable, laid on wall or in trench, including dressing, routing, fixing with suitable clamps/saddles, providing and fixing glands, lugs, ferruling, termination at both ends, testing for continuity and insulation resistance, complete all as specified and directed by Engineer-in-Charge. 1500 RM 0.0000 Excess(+) Full Conversion INR
44 Supply and fixing in repairs, Installation, Testing and Commissioning of OFC Cable to be pulled over head and duly fastened/attached to a PVC coated messenger wire / stay wire of gauge either with the required clamps of suitable size not more than 3 feet apart or with a web between the OFC and messenger wire along with endplates at both ends of the suspended cable complete all as specified and directed. (a) 6F Single mode OFC suitable for outdoor networking applications (i) 6 Fibers type single mode, wavelength 1310, Attenuation 0.38/km (ii) Outer jacket of HDPE sheath (iii) Jelly Filled Core (iv) Wrapped with Corrugated Steel Tape (v) Armoured with a pair of Steel Wire for rigidity (vi) Anti Termite and rodent repellent (vii) Water Proof and moisture resistant. 2000 RM 0.0000 Excess(+) Full Conversion INR
45 Supply and fixing in repair, installation of PVC coated GI messenger/stay wire of suitable diameter and gauge for supporting overhead OFC cable, including fixing with suitable clamps at spacing not exceeding 1.0 metre (3 feet) or providing web support between cable and messenger wire, complete with end plates at both ends, fastening arrangements, anchoring, tensioning and all accessories required for proper installation, complete all as specified and directed by Engineer-in-Charge. 400 RM 0.0000 Excess(+) Full Conversion INR
46 Supply and fixing in repair, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 18 Nos motorized valves and 28 Nos. magnetic sensors . The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated. The Panel should have the following features: - (a) Automatic Operation of Motor Actuated Valves (b) 01 No. SMPS of 5 A rating (c) Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (d) MCB of rating 10A -01 No. (e) Selector Switches as per requirement (f) Compatible with OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Redundant GPRS modem based communication module comprising of one Main and One standby Modem with suitable antenna, modem controller and 02 Nos. data enabled SIM cards (01 No per modem) using two different service providers. The module shall be programmed to automatically toggle between the service providers based on the actual signal strength. switch to the stand by modem in case the main modem fails, Compatible for Wimax Connectivity if required. 1 Each 0.0000 Excess(+) Full Conversion INR
47 Supply and fixing in repair, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 02 Nos. Pumps, 02 Nos Pressure Transmitter, 02 Nos. Priming Motorised Valve, 02 Nos. Solenoid Valves, 8 Nos motorized valves (+02 Spare) and 04 Nos. magnetic sensors PrimingTanks-02(2 Levels) including suitable number of energy meters and 01 Nos Ultrasonic level sensor, . The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated. The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Pump On/Off with switches/Indicators (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves in automatic/manual mode (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Prevention . (h) Manual Mode Operation of all connected sub systems including all valves (in pump houses and connected buildings / overhead tanks) and pumps from the PLC based Control Panel. The PLC based Panel shall consist of the follwing sub systems:- (a) 01 No.PLC with follwing specifications; (i) Suitable Digital inputs/ outputs (ii) 4 serial ports supporting open communication protocol, 01 No. Ethernet port. (iii) Programming software based on IEC to facilitate building of custom built function blocks. (iv) Expandable upto 192 DI / DOs. (b) 01 No SMPS of 5 A rating (c) Suitable No of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (d) MCB of rating 10A-01 No. (e) Selector Switches as per requirement 1 Each 0.0000 Excess(+) Full Conversion INR
47.01 (f) Compatible with OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Make Cisco, Dlink, Redundant GPRS modem based communication module comprising of one Main and One standby Modem with suitable antenna, modem controller and 02 Nos. data enabled SIM cards (01 No per modem) using two different service providers. The module shall be programmed to automatically toggle between the service providers based on the actual signal strength. switch to the stand by modem in case the main modem fails, Compatible for Wimax Connectivity if required. 0.0000 Excess(+) Full Conversion INR
47.02 To make the system fully functional. all panels shall be consisting of the following :- (a) Rack mountable Web Smart Switch with 28 ports and POE for CPE hardware and following specifications:- (i) Number of Ports 24 10/100Base-TX Ethernet ports 2, 10/100/ 1000BASE-T 2 Combo 10/100/1000BASE-T/SFP. (ii) Port StandardSupply and fixing unctions • IEEE 802.3 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3x Flow Control • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 Switching Capacity • 12.8 Gbps 0.0000 Excess(+) Full Conversion INR
47.03 (b) Hot pluggable 1310 nm multimode/Single mode SFP (mini-GBIC) transceiver, supporting full duplex, Gigabit speeds on multimode/Single mode fiber for distances of up to 550m/550m/10km on 62.5µm/50µm/ 9µm respectively in a metal housing to reduce EMI and to increase durability (c) Rack Mountable LIU with the following specifications:- (i) Rack Mountable 12 Port Unloaded LIU (ii) Aluminium Base Material (iii) Slim 1 U mounting height (iv) Metal Shelf Aluminium 1.2 mm thick (v) Splice tray Aluminium 0.6mm (vi) Winding Panel – Plastic (vii) Cable Plug – Rubber for minimum 2 cable entries (viii) Adaptor Panel Aluminium 1.5 mm thick (ix) 2 fiber spools built in for 900 um tight buffered fibre storing (x) Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptor 0.0000 Excess(+) Full Conversion INR
47.04 (d) SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length (i) Size 0.9mm dia (ii) Insertion Loss <=0.2 db, max 0.3 db (iii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iv) Connector Ferrule Ceramic (v) Apex Offset <50um (vi) Fiber Height +-100nm (vii) End Face Radius of Curvature 7mm<R<25mm (viii) Repeatability <=0.2 dB 1,000 times mating cycles (ix) Working Temp -40deg C to +85 deg C (e) SC Simplex Coupler/Adaptor (i) Insertion Loss <=0.2 dB for Zirconia Sleeve (ii) Sleeve/Ferrule Withdrawl Force 2.0N to 5.9N (f) Adaptor Panel (i) 6 port adaptor Panel for SC Adaptors (g) SC-SM-Simplex Pigtail of suitable length (i) Insertion Loss <=0.2 db, max 0.3 db (ii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iii) Connector Ferrule Ceramic (iv) Apex Offset <50um (v) Fiber Height +-100nm (vi) End Face Radius of Curvature 7mm<R<25mm (vii) Repeatability <=0.2 dB 1,000 times mating cycles (viii) Working Temp -40deg C to +85 deg C 0.0000 Excess(+) Full Conversion INR
47.05 (h) CAT6 UTP 24 AWG Patch Cord of suitable length, Plug 30U snag less Seamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a) Development: (i) SCADA Screens for new Updated Panel configuration (ii) Layout for App new Updated Panel configuration (iii) Report Format new Updated Panel configuration (b) On-site development: (i) Modifications in SCADA Screens (ii) Modifications in reporting format (iii) Modifications in App layout 0.0000 Excess(+) Full Conversion INR
47.06 The quoted cost shall deem to include the cost of communication for 12 months from the date of completion. Above All automation panel should connected to existing SCADA server and any other leftout devices and accessories require to commissioning should be consider and same should be include in quoted rates and department will not pay extra cost for the same. Switchgear. Note :- Cost for Synchronising of panel in to existing SCADA system is in contractors scope only and no extra payment shall be given to the contractor by the department. 0.0000 Excess(+) Full Conversion INR
48 Material and labour for repairs to CI/DI specials conforming to IS 1538 and IS 9523, including spigot and socket or flanged fittings such as bends, tees, collars, tapers, flanges, tail pieces and similar specials suitable for 100/150/200/250/300 mm dia CI/DI pipelines, including dismantling, refixing, alignment, cutting if required and all necessary works for proper installation, complete all as specified and directed by Engineer-in-Charge; Note : Cost of joints and jointing materials shall be measured and paid separately under relevant items. 1400 Kgs 0.0000 Excess(+) Full Conversion INR
49 Supply and fixing in repair of CI foot valve of 300 mm (12") dia, flanged end, conforming to IS 4038 PN 0.2, complete with housing, including replacement of nuts, bolts, cutting of existing pipe, welding, fixing in position, alignment, testing and commissioning, complete all as specified and directed by Engineer-in-Charge. 2 Each 0.0000 Excess(+) Full Conversion INR
50 Ditto as per item No 49 but of size 150 mm,complete all as specified and directed by Engineer-in-Charge. 6 Each 0.0000 Excess(+) Full Conversion INR
51 Ditto as per item No 49 but of size 100 mm,complete all as specified and directed by Engineer-in-Charge. 2 Each 0.0000 Excess(+) Full Conversion INR
52 Supply and fixing bituminous patch repair to damaged road surface not exceeding 150 mm depth, including cutting of edges, removal of loose material, preparation of surface, laying of suitable bituminous material in layers, compacting/ramming to required level and camber, finishing smooth and making good the surface,including re complete all as specified and directed by Engineer-in-Charge. 1200 kg 0.0000 Excess(+) Full Conversion INR
53 Supplying and fixing in repairs, Butterfly valve(ISI Marked), Class PN 1.6, hand operated,for 150 mm bore, complete with all necessary tube fittings (such as flanged ends, nuts, bolts, gaskets, etc.), including jointing and testing of the system, complete all as specified and directed. 6 Each 0.0000 Excess(+) Full Conversion INR
54 Ditto as per item no 53.00 above but of size 100 mm,complete all as specified and directed by Engineer-in-Charge. 4 Each 0.0000 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
07 PS APPX C to G Revised.pdf
Tender Documents • 0.80 MB
02NIT.pdf
Tender Documents • 0.39 MB
03 Genpages.pdf
Tender Documents • 0.89 MB
04 PS.pdf
Tender Documents • 0.40 MB
05 Appndx A f.pdf
Tender Documents • 0.39 MB
06 CESC MAKES BR-EM f.pdf
Tender Documents • 0.52 MB
BOQ_864428.xls
BOQ • 5.75 MB
Download all tender documents and submit your bid