Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC Ok | |
| 2 | L2₹24.3 L+₹86,360 (3.68%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹24.5 L+₹1.1 L (4.50%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹28.4 L+₹5.0 L (21.2%)Rejected-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹29.2 L+₹5.7 L (24.4%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹42.6 L
EMD Value
₹85,280
Closing Date
21 Jan 2023, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
MISC REPAIR/ REPLACEMENT OF UNSERVICEABLE ITEMS PERTAINING TO DESERT COOLER, WATER COOLER, REFRIFERATORS, GEYSERS, RO SYSTEM, AIR CURTAIN AND OTHER CONNECTED MISC E/M WORKS UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2022_MES_569733_1
GE/BH-93/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE E/M BASE HOSPITAL DELHI CANT
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹85,280
Yes
3 Mar 2023
17 Dec 2022
23 Jan 2023
17 Dec 2022
21 Jan 2023
2 Jan 2023
Amount
Collecting of unserviceable voltage stabilizer of capacity 1 to 5 KVA from the MES store yard of GE E/M BHDC or dismantling the same from site and transporting to contractors workshop for locating the fault including checking the serviceability of electrical/electronic circuits relays and replacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and directed by Engr-in-Charge Note:- Replacement of defective spares as 'Supply only' of voltage stabilizer will be measured & paid separately under relevant items and Labour charges for taking out old spares & fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Voltage stabilizer of capacity 1 to 5 KVA:-
Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply (Make:- AE/ MECO/ Rishabh)
Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply (Make:- AE/ MECO/ Rishabh)
Printer circuit control card suitable for 2 to 5 KVA.
Input/ output switch (Make:- AE/Rishabh/Meco)
Push on switch (Make:- AE/Rishabh/Meco)
Indicator with neon bulbs (Make:- AE/ L&T/ C&S)
Trigger Transformer for 1 to 5 KVA.
Relay for 1 to 5 KVA voltage stabilizer (Make:- Renutrol/ Technomac)
Time relay and High/low voltage cut off circuit with relay suitable for 2 KVA to 5 KVA (Make- Renutorl/Technomac) Note for item No 2.01 to 2.09:- Materials of item No 2.01 to 2.09 to be incorporated in item No 1.00 here-in-before.
Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 2 KVA voltage stabilizer, complete all as specified & directed by Engr-in-Charge.
All as per srl item No. 3 here-in-before but 3 KVA.
All as per srl item No. 3 here-in-before but 4 KVA.
All as per srl item No. 3 here-in-before but 5 KVA.
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, 150/180 Ltrs including cleaning of cooling coil, air filters, condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note:- Replacement of defective spares for making the water cooler units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Transportation & labour charges for taking down old spares and fixing of new spares shall deemed to be included in unit rate quoted above.
Supply only following new spare parts of Water cooler unit of capacity 40/80 to 60/120, 150/180 Ltrs:-
Starting relay suitable for 40/80, 60/120, 150/180 Ltr. (Make: Sri Ram/Renutrol/Micro Tech.)
Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
Running Capacitor 10 MFD. (Make:- Usha/Epcos/Keltron)
PVC flexible drain Hose pipe 40 mm. (Make :- PRAYAG/SUPREME/PRINCE)
Condenser fan blade aluminium body for Motor 1/32HP, 1/35HP . (Make: Tipcon/ Usha/Epcos/Keltron)
Over load protector device for 60/120 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
Over load protector device for 40/80 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
Over load protector device for 150/180 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
Tharmostat switch. (Make: Indfoss/Renutrol/Godrej.)
Self closing chromium plated push taps for water cooler Capacity 40/80, 60/120, 150/180 Ltr. (Make: Usha/Prayag/ Cera/ Essco) Note for item No 8.01 to 8.10:- Materials of item No 8.01 to 8.10 to be incorporated in item No 7.00 here-in-before.
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 60/ 120 Ltrs from any location and supply installation & testing of new sealed unit compressor of similar capacity in same location alongwith test Certificate from manufacturer and cleaning of condenser by machine doing vaccum on the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion & testing complete all as directed by Engr-in-Charge. (Make- Tecumseh/ Emerson/ LG.)
All as per item No. 9 above but Water cooler of capacity 40/80 Ltrs.
All as per item No. 9 above but Water cooler of capacity 150/180 Ltrs.
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler capacity 60/120 Ltr, supply and fixing of new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE, Crompton Greaves/ Cool Master)
All as per item No. 12 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs.
Disconnecting the mains and taking out the unserviceable condenser coil, S&F new condenser coil as per existing size & patterns for Water/ Coolers of capacity 150/180 Ltrs complete all as specified & as directed.
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 60/120 Ltrs complete all as specified & as directed.
Disconnecting the mains and taking out the unserviceable condenser coil, S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80 Ltrs complete all as specified & as directed.
Dismantling the evaporator/cooling coil of water cooler capacity 150/180, 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing in same position complete all as specified & as directed by Engr-in-Charge.
Cleaning & removing the existing paint of Water Coolers capacity 150/180, 60/120 & 40/80 Ltrs by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour as approved by Engr-in-Charge.
Taking up or down steel tubing and connections and removing off site 15mm bore of pipe complete all as specified and as directed.
Supply and fixing galvanised steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed.
Supplying and fixing in repairs stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions complete all as specified and as directed.
Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed.
Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
Disconnecting from mains and taking down for servicing of Refrigerator/ Deep freezer of Capacity 165/180/195/310/330/450 and 500 Ltrs including detecting the leakage of gas and refilling of refrigerant, cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engr-in-Charge. Note:- Replacement of defective spares for making the Refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Refrigerator/Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
Thermostat switch with Knob. (Make :- Indfoss/ Renutrol).
Starting relay 1/6 H.P. Open type with O.L.P. (Make :- Renutrol/ Sri Ram/ Microtech).
Starting relay 1/8 H.P. open type with O.L.P. (Make :- Renutrol/ Sri Ram/ Microtech).
Copper filter single capilary pencil type.
Vegetable tray PVC for 165 to 330 Ltr capacity (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Defrost tray for refrigerator capacity 165 to 330 Ltr (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
PVC ice tray flexible. (Make:- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Refrigerator bottle shelf for 165 to 330 ltr capacity (Make:- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Waste water tray suitable for different type of Refrigerator. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Freezer door for 165/180/195 Ltr capacity. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Freezer door for 280/300/330 Ltr capacity. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Door Lock for refrigerator 165 to 330 ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Door switch for refrigerator 165 to 330 ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Interior light fittings with bulb. (Make:- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Door handle suitable for 165 to 330 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Refrigerator Glass shelves of capacity 165/180/195 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
Refrigerator Glass shelves of capacity 280/300/310/330 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.) Note for item No 25.01 to 25.17:- Materials of item No 25.01 to 25.17 to be incorporated in item No 24 here-in-before.
Disconnecting from mains and taking down the unserviceable compressor unit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 195 ltr capacity alongwith test certificate from manufacturer including supply of the refrigerant gas R-134A and filling and replacement of filter and put in working condition all as directed by Engr-in-Charge. (Make :Tecumseh/LG/Godrej.) Note:- The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
All as per item No. 26 above but following capacity of Refrigerator:-
Refrigerator 280/300/310/330 Ltrs capacity.
Deep Frteezer 400 Ltrs capacity.
Deep Freezer 500 Ltrs capacity.
Taking out unserviceable evaporator/ freezer from the refrigerator & supply & fixing evaporator/ freezer made out of aluminium press type of capacity 280/300/310/330/400 and 500 ltr with freezer frame and door including connection, complete all as specified & as directed. (Make - Whirlpool/Godrej/Kelvinator/LG/Sumsung.)
All as per item No. 28 but capacity of the refrigerator 165 to 195 Ltrs capacity.
Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height/ floor and refixing the same in same location after repair work/ overhauling all as required at site. Note:- Repair work not included in the quoted rate.
Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface. Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE E/M BHDC (MES)” letter size of 50mm height in stencil in black/white including servicing and greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement.
Supply and fixing in repairs wood wool pad approximate weight 800 - 900gms of size 24” sweep desert cooler as per existing complete all as specified and directed.
All as per item No 32 above but approximate weight 700 - 800gms and 20” sweep.
Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed.
Supply and fixing in repairs of exhaust fan motor copper wounded having 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed.
Supply and fixing in repairs of desert cooler copper wounded kit fan motor of capacity 90 Watt complete all as specified & as directed.
Supply and fixing in repairs front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
Supply & fixing in repairs GI wire mesh for desert cooler pad (Set of Three).
Supply & fixing in repairs PVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed.
Supply & fixing in repairs PVC elbow for desert cooler of suitable size complete all as specified & as directed.
Supply & fixing in repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
S&F in repairs flexible copper conductor cable, 3 core PVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed.
S&F in repairs desert coolers fan blade of 18 inch sweep of plastic body complete all as specified & as directed..
All as per item No 43 here-in-before but 20 inch sweep.
Supply and fixing in repairs side panel of desert cooler of 20” sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed.
Supply and fixing in repairs switch piano flush type single pole one way 5 Amp/ 6 Amp 230 V for desert cooler all as directed.
Supply and fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed.
Supply and fixing in repairs 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed.
Supply and fixing in repairs cooler fan motor bracket sets made up as existing including painting complete all as specified and directed.
S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 18 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE E/M BHDC" letter size of 50mm height in stencil in black/white all as specified and directed by Engr-in-Charge.
Disconnecting from mains and taking down for servicing of Aqua guard and RO water purifier of Capacity 20 to 50 LPH including detecting the leakage of water and refilling, cleaning of unserviceable items including checking the serviceability of electrical/electronic circuits relays, wiring kit, etc., and keeping the Aqua guard and RO system unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engr-in-Charge. Note:- Replacement of defective spares for making the Aqua Guard and RO units in satisfactory working condition will be measured & paid separately under relevant items as 'Supply only' and Labour charges for taking out old spares and fixing of new spares shall deemed to be included in unit rate quoted.
Supply only following new spare parts of Aqua guard and RO water purifier of 20 to 50 LPH capacity:-
Circuit plate PCB for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Compact switch for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Carbon block for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Candle filter for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Cuno candle for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
SV valve for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
UV tube for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Membrane for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Pump K48 for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Adopter 48/24 volts for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
SS fittings (diverter valve) for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Sediment filter for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Carbon filter (Impoted) for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Adopter 36/24 volts for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.)
Adopter kent 24 volts SMPS for RO water purifier. (Make:- Kent/ Aquaguard/ Aquasure/ Livpure.) Note for item No 52.01 to 52.15:- Materials of item No 52.01 to 52.15 to be incorporated in item No 51 here-in-before.
Supply and fixing in repairs of 15mm dia PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (Minimum weight 142 gms) complete all as specified and directed.
Supply only in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 70 x 0.0076 complete all as specified and as directed.
Supply only in replacement PVC insulated, multi stranded, 3 core, flexible, copper conductor cable, of size 40 x 0.0076 complete all as specified and as directed.
Supply only in replacement flexible copper conductor cable 4.0 Sqmm, 3 core, PVC insulated & PVC sheathed complete all as specified and directed.
M&L in repair sub main wiring with 2 runs of 4.0 Sqmm single core, PVC insulated & unsheathed (FR) cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, surface, PVC, rigid conduit, medium grade, as per IS, inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings, fixed on wall/ceiling with saddles PVC and one run of 4.0 Sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of 4.0 Sqmm cable and one run of 4.0 Sqmm earth conductor along with 25 mm PVC conduit with accessories shall be measured as one length)
Taking down the air curtain of any size and dismantling the various parts and carry out the servicing, lubricating and renewal of minor parts and replacing the defective parts and painting, refixing back to the new or old position with grouting materials complete all as specified and directed. (Note: Defective major parts except minor items shall be measured and paid for separately as "Supply only" under respective item of this Schedule.)
Supply only blower motor of air curtain, existing capacity and model complete all as specified and as directed.
Supply only blower drum of air curtain, existing capacity and model complete all as specified and as directed.
Supply only bearing of air curtain, existing capacity and model complete all as specified and as directed.
Supply only PVC flap of air curtain, existing capacity and model complete all as specified and as directed.
Supply only motor housing of air curtain, existing capacity and model complete all as specified and as directed.
S&F in replacement indoor unit complete set, suitable for 1.5 TR split AC of existing make & model, consisting of blower motor, blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, plastic housing with bracket frame etc except compressor suitable for Non CFC gases all as specified and as directed.
S&F in replacement indoor unit complete set, suitable for 2.0 TR split AC of existing make & model, consisting of blower motor, blower, wiring kit complete with display and electronic card and remote assembly, cooling coil, remoting system, plastic housing with bracket frame etc except compressor suitable for Non CFC gases complete all as specified and as directed.
S&F in replacement outdoor unit complete set, suitable for 1.5 TR split AC of existing make & model, including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
S&F in replacement outdoor unit complete set, suitable for 2.0 TR Split AC of existing make & model, including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
Supply and fixing in replacement 1.5 TR Capacity Window type Air Conditioner kit including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
Supply and fixing in replacement 2.0 TR Capacity Window type Air Conditioner kit including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
M&L for servicing of window type AC of 1.0/1.5/2.0 TR capacity, of any type/make, at site /wall, comprising of taking down carefully, removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, indoor cooling unit and condenser coil and providing oil and grease to all moving parts including condensing motor, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Note:- Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE BHDC.
M&L for servicing of split type AC of 1.5/2.0 TR capacity, of any type/make, at site /wall, including removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, cooling unit and condenser coil of outdoor unit, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Notes:- (i) The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering/ whitewash/ colour/ distemper etc shall deemed to be included in quoted rate and no extra payment shall be made to contractor on this account. (ii) Contractor shall maintain register of servicing as per format given by Engr-in-Charge duly signed by User, where the servicing of equipment carry out and produce as & when asked by Engr-in-Charge or GE BHDC.
All as per srl item No 71.00 here-in-before but Tower type split AC of any capacity complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement complete indoor unit for tower type split AC of 3.0 TR, inclusive of blower motor, blower, wiring kit with cooling coil etc, suitable for R-22 Gas, including sheet metal enclosure (DB), terminal etc including all copper tubing of required size & electrical cabling all as required as per site complete all as specified and directed. Make: Carrier/ Blue star/LG Indoor Unit Technical specification- Nominal cooling cap -3.0 TR, Performance rating-36000 BTU/Hr, Indoor fan motor-300 watt, Indoor air flow-1700 Cum/hr, Dimension(WXDXH): 540x410x1825. Gross weight: 70 KG, Operating temp.- > 17 °C, Controller-Remote Control.
Supply, installation, testing and commissioning in replacement complete indoor unit for tower type split AC of 3.5 TR, inclusive of blower motor, blower, wiring kit with cooling coil etc, suitable for R-22 Gas, including sheet metal enclosure (DB), terminal etc including all copper tubing of required size & electrical cabling all as required as per site complete all as specified and directed. Make: Carrier/Blue star/LG Indoor Unit Technical specification- Nominal cooling cap -3.5 TR, Performance rating-42000 BTU/Hr, Indoor fan motor-300 watt, Indoor air flow-1700 Cum/hr, Dimension(WXDXH): 540x410x1825. Gross weight: 70 KG, Operating temp.- > 17 °C, Controller-Remote Control.
Supply, installation, testing and commissioning in replacement complete outdoor unit for Tower type split AC of 3.0 ton, except compressor, suitable for R-22 Gas, condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed. Make: Carrier/blue star/LG Outdoor Unit Technical specification- Power Supply- 3 phase, 380 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 990X345X965, Gross weight - 93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr.
Supply, installation, testing and commissioning in replacement complete outdoor unit for Tower type split AC of 3.5 ton, except compressor, suitable for R-22 Gas, condenser coil, wiring kit , condenser fan motor, condenser fan, terminal etc also making platform for outdoor unit with suitable size of fastener and MS frame work and making good the disturb surface including all copper tubing of required size, control wiring all as required as per site complete all as specified and directed. Make: Carrier/blue star/LG Outdoor Unit Technical specification- Power Supply- 3 phase, 380 Volt, 50 Hz, Outdoor fan motor-290 watt, Fan motor speed-830 RPM, Dimensions(WXDXH): 990X345X965, Gross weight - 93 KG, Refrigerant piping-Max pipe lenght-20 mtr, Max difference in level-10 mtr.
Note for Item Nos 73.00 To 76.00:- Old taking down outdoor unit of any capacity and size shall be deposited to MES store yard from existing location. The rate include necessary transportation & Manpower to dismantling and transporting the unit.
Supply and charging R-22 refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
Supply and charging R-134A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
Supply and charging R-410A refrigerant gas, including and after carrying out the pressure test with nitrogen and rectify the leakage in summer appliances all as specified and as directed.
Attending the complaints for Water heater geyser of Capacity 25/ 35/ 50 Ltrs at different location of Base Hosp area including tracing & rectify the fault of system, incl checking incoming/outgoing hot & cold water supply connection, electric connection of geysers including replacement of unserviceable parts complete all as specified and as directed. Note: The spare parts required for repairs shall be measured and paid separately as "Supply only" under respective item of this Schedule.
Taking down the geyser from its existing position for general cleaning/overhauling and descaling the tank and assembly with suitable detergent and making fully serviceable and refixing in new/old position complete with testing complete all as specified and as directed. Note: (i) Item No 80.00 here in before shall not be payble where this item is executed. (ii) The spare parts required for repairs shall be measured and paid separately as "Supply only" under respective item of this Schedule.
Supply only fusible plug type (pressure valve) Air release valve complete all as specified and as directed.
Supply only air release valve (Nozzle) as per sample complete all as specified and as directed.
Supply only gasket of thickness 5 mm for geyser assembly of 06 holes/ 08 holes/ 09 holes complete all as specified and as directed.
Supply only Syphon assembly of copper, 06 holes with nut bolts/stud/washer complete all as specified and as directed.
Supply only indicating lamp green/ red for geyser rectangular type/round type complete all as specified and as directed.
Supply only inner shell of Geyser of cap 25 Litre made out of steel tank complete all as specified and as directed.
All as per Srl item No 87.00 here-in-before but for 35 Litre Capacity complete all as specified and as directed.
All as per Srl item No 87.00 here-in-before but for 50 Litre Capacity complete all as specified and as directed.
Supply only outer body of Geyser Capacity 25/ 35/ 50 Litre of 20 SWG MS Sheet and woolen glass duly painted complete all as specified and as directed.
Supply only thermostat switch of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed. Make- THEETA/BAJAJ/RECOLD/DASPASS
Supply only heating element 1.5 KW (round type) with rubber gasket complete all as specified & directed. Make- Theeta/Bajaj /Recold/ DASPASS (As per sample)
All as per item No. 92.00 here-in-before but round type 2 KW complete all as specified & directed. (As per sample)
All as per item No. 92.00 here-in-before but triangle type 1.5 KW complete all as specified & directed. (As per sample)
All as per item No. 92.00 here in before but triangle type 2 KW complete all as specified & directed. (As per sample)
Supply only 15mm size PVC connection pipe 600mm long heavy duty with brass nut for hot/cold water complete all as specified & directed.
Supply only 15mm size PVC connection pipe 450mm long heavy duty with brass nut for hot/cold water complete all as specified & directed.
Supply only brass chromium plated angle valve suitable for 15 mm bore pipe complete all as specified and as directed.
Supply only 15mm size brass CP extension nipple complete all as specified & directed.
Supply only 15 mm size Brass CP Angle valve 2 in 1 complete all as specified & directed. Make-Zim/ Parko/Kingston)
S&F dash fastener mild steel 150 mm long x 10 mm dia with pin and bolts complete for hanging of geyser properly on wall and making good to the disturbed surfaces including plastering and white washing complete all as specified and as directed.
Taking down geyser from existing location, preparation of body of geyser by knotting and stopping of outer surface, repainting the complete outer surface of geyser with one coat of synthetic enamelled paint 1st quality and refixing the same on wall in existing location and writing "GE E/M BHDC" of letter size 10 mm complete all as specified and as directed.
M&L for unscrewing the nut bolt and taking out the base plate geyser assembly and copper tank making soldering and brazing of tank to stop the leakage of tank and fixing back in the position complete all as specified & directed.
S&F in repair 5 star rated vertical mounted Water heater geyser of capacity 25ltrs having Features: outer body-ABS, Safety feature-Multi function safety valve, thermostat, thermal cut-out, vitreous enamelled glass line tank with CRCA outer body with powder coated with heavy duty anode rod prevent from corrosion & permanent scaling with adjustable knob for temp setting between 30°C to 75°C, high density PUF for thermal insulation with LED power indication. Technical specifications: voltage-230V, Type-storage, Frequency-50Hz, Wattage- 2 Kilo Watts, Pressure-8 Bar, Pressure Class- Class 1 complete all as specified & directed. Note- Old unserveciable geyser of any capacity shall be deposited at MES store yard for further disposal.
S&F in repairs PVC insulated unsheathed copper wire of size 1.50 Sqmm 3 run drawn in and including 20mm dia medium grade PVC conduit complete all as specified & directed. Note: 03 run of Copper cable 1.50 Sqmm along with 20 mm PVC conduit shall be measured as one length.
Supply only in replacement sheet metal enclosure with 01 No MCB SP 25 Amp, 240 Volt, 3 pin Metal clad top and metal clad socket 20 Amp complete all as specified and as directed.
S&F in repair MCB SP 240 Volts, 20 to 63 Amps complete all as specified and directed.
Supply only in replacement Syphon assembly of copper, 09 holes with nut bolts/stud/washer complete all as specified and as directed.
Supply only thermostat cut out of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed. Make- THEETA/BAJAJ/RECOLD/DASPASS
HONEY COLLECTION
MK Enterprises
R R Associates
YASHVI ENGINEERS
M/S GEETANJALI ENTERPRISES
DP Traders
RUCHIKA ENGG.WORKS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .