Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹13.4 L+₹8,297.50 (0.62%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹14.9 L+₹1.6 L (11.7%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹17.2 L+₹3.9 L (29.1%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹17.5 L+₹4.1 L (30.8%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L5 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
30 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(South) Bangalore
GE(South) Bangalore
REPAIR RENEWAL MAINT OF EXT ELECTRIC SUPPLY, STREET LIGHTINGS AT FMCC, K KSUB AREA, STN HQ, OFFICERS MESS ANNEX, BRV, 56 SUP COY, OLD MH LINE, SIGNAL SECTION, SELECTION CENTRE (SOUTH), BD BK, ARMY SCHOOL, M BK, SUOE, DHOBIGHAT, ZRO, MES IB, CWE(A
2022_MES_561016_1
8646/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
As per tender document
6 documents required · 6 mandatory
₹500
GE(South) Bangalore
₹15 L
Yes
24 Dec 2022
2 Nov 2022
2 Dec 2022
2 Nov 2022
30 Nov 2022
16 Nov 2022
Amount
Excavation in trenches in Soft/ loose soil not exceeding 1.5 M wide and not exceeding 1.5 M in depth for laying of UG cables and LT Panel board foundation etc and getting out.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point all as directed.
M&L for sand cushioning in trenches for bricks of u/g cable with coarse sand laid dry in trenches with uniform thickness.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection all as specified and directed.
Material & Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Material & Labour for PCC 1:3:6 type C2 (using 20mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Taking down old unserviceable service cable 10/6 sqmm 2 core
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire, one twin core cable flat of size 06 Sqmm. (Make - Havells/Plaza/Fenolex)
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire, one twin core cable flat of size 10 Sqmm. (Make - Havells/Plaza/Fenolex)
Taking down old unserviceable XLPE UG Cable form site any size any capacity
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium sonductor of size 10 Sqmm x 2 core including taking down unserviceable UG cable complete all as specified and directed. (Make- Plaza/ Havells/ Finolex)
All as per Item No 12 but of size 10 Sqmm x 4 Core
All as per Item No 12 but of size 16 Sqmm x 4 Core
All as per Item No 12 but of size 25 Sqmm x 3.5 Core
All as per Item No 12 but of size 35 Sqmm x 3.5 Core
All as per Item No 12 but of size 50 Sqmm x 3.5 Core
All as per Item No 12 but of size 70 Sqmm x 3.5 Core
All as per Item No 12 but of size 95 Sqmm x 3.5 Core
All as per Item No 12 but of size 120 Sqmm x 3.5 Core
Dismnantling of old unserviceable GI Pipe of capacity 80/100mm dia
Supply and lay pipe galvanized light grade including fittings 40mm dia for cable protection using road crossing etc
All as per Item No 22 above but of size 80mm dia
Material & Labour for LT straight through joint for under ground cable for 3 ½ / 4 Core upto 50 sqmm all as specified and directed.
All as per Item No 24 but of size 70 to 120
M&L preparation of surfaces of pole for painting of steel tubular pole,vertical with one coat of aluminium paint incluing painting black and white strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not,exc 30 cm high & letters or figures n'exc 10 Nos complete all as directed.
M&L preparation of surfaces of pole for painting of PCC pole,vertical with one coat of cement base paint incluing painting black and white strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering with writing letters or figures(Block), height not,exc 30 cm high & letters or figures n'exc 10 Nos complete all as directed.
Excavation in post holes (or similar holes) each not exc 0.5 cum and getting out including, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/looe soil complete all as specified and directed.
Dismantling of concrete poles of any size and removal from the site complete all as specified and directed.
Supply and errect swaged steel tubular poles, 9 meter long complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and directed.
Material & Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Material & Labour for PCC 1:3:6 type C2 (using 20mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Material & Labour for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
Dismanling olf old unserviceable GI Bracket from Pole any size any dia
M&L for GI bracket for street light fittings 32mm dia 1.2Mtr length including D/C clamps for PCC/Steel pole round or square nut bolt and washers etc and painiting of bracket and clamps all as specifiedf and directed by Engr in Charge
Dismanling old unserviceable of MCB/MCCB any type any capacity
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 250 Amps with breaking capacity 36 KA Make- Havells
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 200 Amps with breaking capacity 36 KA Make- Havells
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 160 Amps with breaking capacity 36KA Make- Havells
S&F in replacement ofMCCB 3 pole 415 volt fixed type of capacity 125 Amps with breaking capacity 16 KA Make- Havells
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 100 Amps with breaking capacity 16 KA Make- Havells
S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 63 Amps with breaking capacity 16 KA Make- Havells
Dismanling old unserviceable Junction Box any size capacity
Supply and fixing of Thermoplastic IP 66/67, weather proof, corrosion free, halogen and silicon free, UV reistence, insulated and shock proof, High impact strength, flame retardant and self extinguishing, Glow wires test conducted at 960 Deg junction box suitable for terminating cable for 6Sqmm/10 Sqmm/16 Sqmm including necessary cable gland and check nut Size of M32 (incoming and out going cbles) and mounting bracket clamp suitable size as per site with nut bolt washer complete all as specified and directed. Make- Hensel
Taking down old unserviceable form pole PVC Conduit and PVC Copper wire
S&F PVC Conduit pipe from PVC Junction Box to street light bracket for protection of cable fixing clamp on PCC poles drilled the hole and insert a PVC gutti and screwed suitable size but bolt
S&F PVC 3 Core copper cable 1.5Sqmm insulated for fixing of junction box to street light fittings complete all as specified and directed Make- Polycab
Dismantling of old unserviceable feeder pillar box any size any capacity
Fabricate, Supply, testing, commissioning for Feeder pillar box made of copper bus bar of 400A capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.0mm thick, CRCA sheet, angle iron frame of size 40x40x6mm including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform etc complete all as specified and directed
Auromirra Enterprises
GS TRADERS
SREE CONSTRUCTIONS
RRK PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .