Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹2 GC 1A PUL PEHLADPUR NEW DELHI 110044 EMAIL DEVENTERPRISES20007 GMAIL COM | ₹2 |
Tender Value
Refer Docs
EMD Value
₹2.9 L
Closing Date
21 Feb 2022, 11:00 amClosed
Construction of Gate, Frisking booth, Approach road from rear side of DAIC building to Rajender Prasad road with SITC of Security Infrastructure Equipment, Civil, Electrical and landscaping works etc at Dr. Ambedkar International Centre DAIC, 15 Janpath, New Delhi 110001
NSL/CEO/DAIC/NIT/2022/469
NSL/CEO/DAIC/NIT/2022/469
Open Tender-Domestic
Civil Works General
New Delhi, Delhi
₹11,800
₹2.9 L
30 Jul 2026
1 Feb 2022
21 Feb 2022
21 Feb 2022
26 Feb 2022
Name of Work: “Construction of Gate, Frisking booth, Approach road from rear side of DAIC building to
Rajender Prasad road with SITC of Security Infrastructure/Equipment, Civil, Electrical and landscaping
works etc.” at Dr. Ambedkar International Centre (DAIC) 15 Janpath, New Delhi-110001.
SR. NO. DESCRIPTION DSR AMOUNT NDSR AMOUNT
A DISMANTALING 84,278.23 20,475.00
C FURNITURE 0.00 338,613.86
E AIR-CONDITIONING 0.00 97,063.00
F SECURITY INFRASTRUCTURE 1,164,060.00 15,265,017.00
G LANDSCAPING, PATHWAYS & EXTERNAL ELEMENTS 3,703,948.93 1,112,221.78
GRAND TOTAL INCLUDING GST 29,347,527.79
GRAND TOTAL INCLUDING GST 29,347,527.79
Digitally signed by ASHWANI
ASHWANI KUMAR BANSWAL
Name of Work: “Construction of Gate, Frisking booth, Approach road from rear side of DAIC building to Rajender Prasad road with SITC of Security Infrastructure/Equipment, Civil, Electrical and landscaping works etc.” at Dr. Ambedkar
International Centre (DAIC) 15 Janpath, New Delhi-110001.
Bill Of Quantity
SR. NO. 2021 DSR NO. DESCRIPTION UNIT QUANTITY DSR RATE DSR AMOUNT NDSR RATE NDSR AMOUNT
A DISMANTALING
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within
50 metres lead as per direction of Engineer-in-charge.
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of
unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.
15.7.4 In cement mortar CUM 12.50 1698.45 21230.63
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of
unserviceable material within 50 metres lead.
Dismantling stone cladding on wall in cement mortar including stacking of serviceable material and disposal of
4 unserviceable material within 50 metres lead.
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead
as per direction of Engineer-in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) CUM 8.00 2007.10 16056.80
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/
6 15.44 by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
a 15.44.1 15 mm to 40 mm nominal bore METER 20.00 124.10 2482.00
b 15.44.2 Above 40 mm nominal bore METER 20.00 134.25 2685.00
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled
7 15.58 materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting CUM 2.00 2328.55 4657.10
reinforcement bars.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
9 NDSR Dismantling of bollard light as required. EACH 4.00 1200.00 4800.00
Dismantling of existing Electrical installations, switches, sockets, GI boxes, MCBs, DBs, MDBs including wiring , cables,
Conduits with chasing disposal of the debris/ unserviceable and servicable material to the closest dumping ground as
per the instructions of the Engineer In charge. All damaged surfaces to be repaired using plaster.
11 MR Shifting/ removal of pipes (sewage and rainwater) as per directions of engineer-in-charge. rmt 15.00 392.00 5880.00
Shifting/ removal of existing fire header pipes including handing over all salvagable material to the client and
12 MR disposal of the debris/ unservicable material to the closest dumping ground as per the instructions of the Engineer In each 1.00 935.00 935.00
charge. All damaged surfaces to be repaired using plaster.
Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful
13 15.51 materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated each 1.00 791.65 791.65
Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near
14 19.24 the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer- charge :
19.24.1 Rectangular manhole 90x80 cm and 45 cm deep each 2.00 2096.10 4192.20
15 1.1 Carriage of material by mechanical transport including loading unloading and stacking
1.1.1 Lime, murrum, building rubbish
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and
disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
2.28.1 All kinds of soil SQM 1300.00 28.15 36595.00
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm
2 2.6.1 in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto Cum 33.00 205.45 6779.85
50 m and lift upto 1.5 m, as directed by Engineer-in-charge.- All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding
3 2.25 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum 25.00 253.95 6348.75
4 1.1.2 Disposal of surplus earth by mechanical transport including loading, unloading for a lead upto 10 Km. Cum 8.43454 368.20 3105.60
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -
All work up to plinth level :
6 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) Cum 10.00 6326.05 63260.50
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement
concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /
Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /
retard setting of concrete, to improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In
case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor
shall have discretion to either re-design the mix or bear the cost of extra cement.
5.33.1 All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 22.00 7997.30 175940.60
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all
8 complete upto plinth level.
5.22.6 Thermo-Mechanically Treated bars KG 1161.59 89.65 104136.54
9 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete SQM 60.00 307.95 18477.00
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) :
10 4 graded stone aggregate 20mm nominal size).
Designing, providing, installation and fixing of walls made out of GI Steel Sheet 0.5MM - EPS - Steel composite sand
coated insulated sandwich panels with toughned groove locking systems complete as per directions of engineer-in-
charge/ Architect.The E.P.S. used as the core will be self extinguishing type. The overall thickness of the wall shall not
be less than 72mm. The item to include all nessesary hardware, fittings and fixtures required. The item to also include
making nessesary cut-outs for doors, windows, ventilators, etc with complete sub-frame and finishing.
Desiging, Providing, installation and fixing of roof Puff panels made up of 50+80mm thick composite PUF panels
sandwiched between PPGI 0.5mm Sheets including all required necessary hardware, fittings and fixture. The outer skin
of trapezoidal PPGI sheet with depth of crest -28-30mm. Pitch 195-200mm trapezoidal sheet & inner skin micro riving
PPGI sheet & minimum 50mm thick layer of rigid CFC free polyurethane foam of density of 40±2 Kg/m3 as insulation.
The color of PPGI sheetto be as per approval of engineer-in-charge/ Architect. The gaps between puff panels to be
sealed as per manufacturers specifications to make it air and water tight to prevent the entry of dust and water
seepage in case of extreme weather conditions.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a
13 priming coat of approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works KG 7200.00 142.30 1024560.00
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat
11.3 of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate SQM 67.00 545.00 36515.00
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm
thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting
15 the joints with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption
less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over
11.46 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm
including grouting the joint with white cement & matching pigments etc. complete.
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler
17 11.48 of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as
per direction of Engineer-in-charge.
GYPBOARD CEILING :- Providing and fixing false ceiling at all height including providing and fixing of frame work
made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both
side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm
and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long
with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts &
bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at
the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction
perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm
Including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing
compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint
and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of
making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all
complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting
12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I SQM 67.00 1145.95 76778.65
CEILING PELMETS :- Providing and fixed pelmet of overall size 150mmx150mm and made hardwood framings hung
19 MR from ceiling @1000mm centre to centre with 1 nos of 12mm thk. fire retardant ply on vertical & horizontal surface RMT 6.00 939.00 5634.00
(straight & curved). Inclusive of finishing in Paint.
DOOR FRAMES- Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought
20 9.1 framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash
fastener shall be paid for separately).
9.1.1 Second class teak wood CUM 0.30 131576.95 39473.09
FLUSH DOOR:- Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,
core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering
with vertical grains or cross bands and face veneers on both faces of shutters :
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws SQM 4.80 2015.75 9675.60
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters
(over all area of door shutter to be measured)
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat
on unexposed surface etc. complete:
9.40.1 2nd class teak wood
24 9.72 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete
DOOR CLOSERS:- Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer
(having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from
701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
MORTICE LOCK AND LEVER HANDLES- Providing and installing Tubular Handle TH 123 with Roses & Escutcheon in SS
26 MR packaged with Mortice lockset 55mm backset, 20 SS forend, SS strike plate and EP Cylinder for all flush doors. EACH 2.00 2866.00 5732.00
27 9.81 HANDLES;- Providing and fixing bright finished brass handles with screws etc. complete:
TOWER BOLTS:- Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic AC 10 as per IS : 1868 ),
transparent or dyed to required colour or shade, complete:
DOOR STOPPER:- Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc.
UPVC Windows : Supply and Fixing of Tripple Track/ Tripple Channel UPVC Windows, DGU/ Sandvich Glasses (6 mm
30 MR Reflective Glass + 10 mm Air Gap + 6 mm Plain Toughned Glass) on two tracks and SS Mesh on One Track, complete sqm 12.00 10422.00 125064.00
as per the requirement of engineer in charge.
PRIMER: Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Water thinnable cement primer.
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS
32 13.48A 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with
silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied
@ 0.90 litre/10 sqm.
33 13.45 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with
1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation
concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside
34 19.7 plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement
and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,
35 19.7.1 total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 EACH 3.00 11687.10 35061.30
36 13.114 Melamine polishing on wood work (one or more coat). SQM 30.00 118.35 3550.50
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood
37 9.17 particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or
studding to be paid separately):
Making teak wood steps for steps of Dais platform. The steps to be of width upto 1200mm, riser upto 195mm and
38 NDSR tread upto 300 mm complete as per detail drawings. (Grade A/ First Class Nagpur type teak wood) complete with all Each 2.00 155034.00 310068.00
neccesary hardware as per instructions of engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding,
grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless
steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless
39 10.28 steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per KG 80.00 612.25 48980.00
approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works KG 78.00 142.30 11099.40
Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle
board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade
IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane
primer (fittings to be paid separately).
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made
with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S.
tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and
maintaining it in a serviceable condition for the required duration as approved and removing it there after .The
42 14.72 scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for Sqm 52.00 285.00 14820.00
inspection of work at required locations with essential safety features for the workmen etc. complete as per directions
and approval of Engineer in-charge .The elevational area of the scaffolding shall be measured for payment purpose
.The payment will be made once irrespective of duration of scaffolding.
Repairing work of Curtain motor including rewinding, replacement of motor contactor, servicing of ball bearing,
checking of all connection, greasing and oiling with Warranty of Six Months.
Providing and Placing in position 2.5 Seater Sofa. Upperstructure shall be a single shell thick hot pressed plywood. The
seat is made up of foam with density 40 Kg/m3 having multiple coloured upholstery options with fabric and
leatherette. The back is made up of 30+/-2 Kg/m3 with multiple coloured upholstery options available in leatherette
and fabric. The leg is a welded assembly made up of stainless steel tube and plate. The work shall be carried out as
per guidance and instrcutions recieved from engineer incharge.
Providing and Placing in position 1 Seater Sofa. Upperstructure shall be a single shell thick hot pressed plywood. The
seat is made up of foam with density 40 Kg/m3 having multiple coloured upholstery options with fabric and
leatherette. The back is made up of 30+/-2 Kg/m3 with multiple coloured upholstery options available in leatherette
and fabric. The leg is a welded assembly made up of stainless steel tube and plate. The work shall be carried out as
per guidance and instrcutions recieved from engineer incharge.
Providing and placing of center Table with wooden legs with black color tempered glass on top with white painting
Providing and placing of side table with wooden legs with black color tempered glass on top with white painting
Dimensions: 600 X 600 X 430.
Providing and fixing of linear workstation/ guard table of size 1200mm X 600mm of following sprcifications -
CONFIGURATIO : LINEAR
TABLE TOP : Table top is made of 25mm E1 Grade pre-laminated particle board with PVC edge banding with Anodised Flipup
ABOVE T.T :Mains:
:08mm thk 1200Wx300H of Sandwich glass on metal holding brackets is considered.
Privacy: :08mm thk 1200Wx300H of Frosted glass on metal holding brackets is considered.
Rerutns: Not considered.
:MS-POWDER COATED wire tray WITH switch plate 150D/300D*120H below the table top and Aluminum flipups of
WIRE MANAGEMENT
500Wx120D on table top is considered.
: Sole: A) 90dgree or 98 degree Legs are made-up of Aluminum spl design extruded tube which gives sleeker look
and avoid sharp edges. The tubes are connected with Die cast connectors for better aesthetics.
B) For better aesthetics the decorative strip can be provided with Metal
BEAMS :Leg to Leg Beam will be made of Aluminum extruded powder coated with Trapezoidal cross section of size 55 x 40 x
Horizontal beams below table top will be with 50mm x 25mm rectangular tube CRCA Powder coated.
MODESTY : Below wire tray MS powder coated Modesty of 300H is considered. At alise side 350H Perforated Modesty has been
considered with necessary hardware. nos 1.00 44554.46 44554.46
Providing & Installation of Reception table of overall size upto 1.5m x 0.75m x 0.75m/ 1.2m (ht) including side storage
credenza of size 1.2m X 0.75m X 0.75/1.2m (h), made out of 19mm thk. Commercial Board complete as per design.
One (1) number Drawer pedestal with 3 lockable drawers and channels to be provided under the table to be
finished in veneer of approved shade with complete melamine polish. All front visible surfaces of 1.2m height face,
its side, front side of sice crdenza to be finished using 8mm thick Acrylic solid surface of approved shade and color as
per details. Internal side surfaces to be finished in veneer of approved shade with complete melamine polish. The
internal side of storage to have 0.8mm thcik balancing laminate
Proving and placing of chair with seat made up of 1.2± 0.1cm thk. Hot pressed plywood. The back is made up of
injection moulded glass filled nylon & upholstered using Quilted knitted fabric. Seat Size:- 47cm(w) × 51.5cm (D). The
HR polyurathene foam is moulded with density =45+/-2 kg/m cube and hardness 16± 2 kgf as per is:7888 for 25%
compression. The armrest has an up=Down adjustment of 8.0 ± 0.5cm which is provided in armrest structure. Armrest
structure is chrome plated and fitted with an armrest top. It shall have Front pivot synchro mechanism with following
features. 360 degree revolving type, Single point control, front fivot tilt, tilt tension adjustment, 4 position locking with
anti- shock feature, seat/back tilting ration of 1:2. The lumber support consists of polypropylene pad with mouled
polyurathene foam & covered with polyester fabric. The height of lumber pad can be adjusted through two
projecting knobs provided on the rear side of the pad. Lumber pad has an adjustment of 8.0± 0.5 cm in height. The
pneumatic height adjustment has an adjustment stroke of 10cm. The pedestal is fabricated from 0.2cm thick HR sheet
chrome plated and assembled with injection moulded moulded black polypropylene hub cap. the work shall be
carried out as per guidance and instructions recieved from Engineer Incharge. This shall come along a headrest
assembly consisting of polypropylene pad with lumbr support and covered with polyester fabric. Neckrest assembly
has an adjustment stroke of 4.2cm and otation adjustment stroke of 76 degrees.
SUB TOTAL 0.00 338613.86
DISTRIBUTION BOARDS
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,
powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load
2.1 of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and
2.2 terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.
Supplying and fixing following rating, double pole, (single phase
and neutral), 240 V, residual current circuit breaker (RCCB),
2.14 having a sensitivity current 30 mA in the existing MCB DB
complete with connections, testing and commissioning etc. as
CABLES AND WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed GI steel conduit, with modular switch, modular plate, suitable GI
box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/
1.5 recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop Meter 60.00 265.00 15900.00
earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/
1.6 recessed steel conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop Meter 100.00 392.00 39200.00
earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed steel conduit as required.
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre 100.00 356.00 35600.00
1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire Metre 25.00 426.00 10650.00
1.7.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire Metre 25.00 670.00 16750.00
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in
recess etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including
1.31 providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Each 6.00 401.00 2406.00
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including
1.32 providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as Each 6.00 495.00 2970.00
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent
switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed GI steel
conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including
connections but excluding modular plate etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box
including connections but excluding modular plate etc. as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine
1.19 tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. Metre 10.00 33.00 330.00
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including
connections but excluding modular plate etc. as required.
1.24.6 Telephone socket outlet Each 2.00 119.00 238.00
1.24.7 TV antenna socket outlet Each 1.00 119.00 119.00
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in
1.20 case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
DATA / VOICE WIRING SYSTEM
MR Data Outlet
Supply & Fixing of PCB based Information Outlet (I/O) RJ45, Category 6 standards as per TIA-568C.2, UL listed,
including termination of Catergory-6 UTP Cable. The outlet shall have RJ-45 type connector with bend limiting and
strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable. The Each 6.00 250.00 1500.00
outlet shall be fixed in existing box & cover plate in wall/furniture/floor complete as required.
Supply & Fixing of Single Faceplate, Single Port (RJ45-DATA) square plate having spring shuttered front access for
preventing ingress of dust.
Supply & Fixing of Dual Faceplate, Duplex Port (RJ45 for data ) and (RJ-11 for voice) or as required square plate
having spring shuttered front access for preventing ingress of dust.
Supplying and fixing in position GI box for data outlet suitable for fixing of RJ 45 face plate complete as required.
MR Supplying and laying HDMI Cable in existing conduit / raceway. Metre 15.00 140.00 2100.00
LIGHTING FIXTURES AND FITTING
Supply, assembling, installation, testing & commissioning of following type of light fixtures and fans. All fluorescent
fixtures shall be provided with electronic ballast, power factor improvement capacitors & lamps and installation
arrangement using proper support etc. complete as required.
MR 15W Recessed mounted LED downlighter Nos. 6.00 1300.00 7800.00
MR 1200 mm sweep ceiling fan with down rod complete with all accessories as required . NOS 1.00 2866.00 2866.00
MR Supplying, assembling and making HDMI Cable end male connector type-A. Nos 2.00 204.00 408.00
Supply of Luminaire made of extruded aluminium alloy (grade 6063) with die-cast aluminium components and non
corrosive SS fasteners,Reflector system made of aluminium sheet(powder coated white for high reflection). Silicon
gasket GI mounting plate with an anchorage unit made out of hot dip galvanised steel for extra guarantee against
corrosion. Luminaire can be aligned on the mounting plate around 360° Cable entries for through-wiring of mains
supply cable Integral power supplyEarth connection Safety class I Protection class IP65 for the control gear part, IP67
for led module, minimum 110lm/w for led module & it should be equipped with fins for better thermal management,
shall be equipped with inbuilt potted driver with P.F >.97 inbuilt surge protection of 4KV THD <10%Efficiency 88%,
Operating voltage 100-277vac, input voltage 230-240Vac Frequency of 50Hz, Operating temperature 0-50 degree
celcius. CE - Conformity mark Suitable for operation on 240V, 50Hz single phase ac supply. MCB Door should diecast
alumnium and IP65 rated.
Supply of LED Flood light, Luminaire made of extruded aluminium alloy with wattage not more than 50W, in 3000K
Safety class I Protection class IP65 for the control gear part, IP65 for led module, minimum 100lm/w for led module & it
should be equipped with fins for better thermal management, shall be equipped with inbuilt potted driver with P.F
>.90 inbuilt surge protection of 4KV Operating voltage 100-277vac, input voltage 230-240Vac Frequency of 50Hz,
Operating temperature 0-50 degree celcius. CE - Conformity mark Suitable for operation on 240V, 50Hz single phase
Supply of LED Bollard, Luminaire made of extruded aluminium alloy with wattage not less than 15W and minimum
900mm in height. Bollard should give light asymmetrically in one direction only, in 3000K Safety class I Protection class
IP65 for the control gear part, IP65, IK08 CRI>80for led module & it should be equipped with fins for better thermal
management, shall be equipped with inbuilt potted driver with P.F >.90 inbuilt surge protection of 3KV
THD<10%Operating voltage 100-277vac, input voltage 230-240Vac Frequency of 50Hz, Operating temperature 0-50
degree celcius. CE - Conformity mark Suitable for operation on 240V, 50Hz single phase ac supply.
Supply of LED Spike light, Luminaire made of die cast aluminium alloy with wattage not more than 6W, in 3000K.
Fixture should be supplied with snoot to avoid light spill and with IP67 connector Safety class I Protection class IP66 for
the control gear part, IP65 for led module, minimum 80lm/w for led module & it should be equipped with fins for
better thermal management, shall be equipped with inbuilt potted driver with P.F >.90 inbuilt surge protection of 3KV
Operating voltage 100-277vac, input voltage 230-240Vac Frequency of 50Hz, Operating temperature 0-50 degree
celcius. CE - Conformity mark Suitable for operation on 240V, 50Hz single phase ac supply.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including
5.8 connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and Metre 120.00 853.00 102360.00
with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry
5.6 enclosure with cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ Set 2.00 11794.00 23588.00
coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in
recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed
conduit/submain wiring/ cable as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing
surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including
1.21 cutting the wall and making good the same in case of recessed conduit as required.
D AIR-CONDITIONING
Supply, installation, testing and commisioning of Coolong Only Inverter Type HI wall type BEE certified 3 Star 2.0 TR,
split type air conditioners With R410 / R32 Refrigerant with cordless remote controller including connection of external
& internal units (with copper pipe condenser only). The cost to include supply and installation of MS stand/ cage for
Supply, installation, testing and commisioning of refrigerent piping (supply and return) complete with insulation as per
manufacturers specifications for following AC units including cutting and chasing of walls/ plaster, sadling of loose
pipes (in exposed locations) and repair of the chased wall/ plaster surfaces with cement mortar.
Supply, installation, testing and commisioning of PVC drain piping (10 kg/m3) as per manufacturers specifications for
MR following AC units including cutting and chasing of walls/ plaster, sadling of loose pipes (in exposed locations) and RMT 5.00 268.00 1340.00
repair of the chased wall/ plaster surfaces with cement mortar.
Supply, installation, testing and commisioning of interconnecting wire of following sizes as per manufacturers
specifications.
SUB TOTAL 0.00 97063.00
D SECURITY INFRASTRUCTURE
1 Automatic Parking Hydraulic Boom Barrier
Boom Length in 3 mtr. LED Type Boom, LED Connectivity
Options., Automatic Barrier Feature:
Barriers Hydraulic barrier (Right /Left Version)with boom
Opening/ Closing Time – 4-5 Sec. Fully.
Automatic with use cycles 100% with push button, Four J
hooks, Foundation plate. Round Boom. Push Button.
BARRIER MODEL 630 STD
Power supply (Vac / Hz) 230 {+6%/ -10%} / 50
Absorbed power (W) 220
Absorbed current (A) 1
Type of oil FAAC HP OIL
Oil quantity (Lt) ~ 1.8 , Barrier weight – 73 Kg
Winding heat protection (°C) 120
Anti-crushing system standard by-pass valves
Type of slow-down Electronic
Operating ambient temperature (°C) -20 / +55
Hood protective treatment Catachresis AISI 316 L
Protection class IP 44
Body Dimensions 390,290, 200,94
Photocell (Safety Beam Sensor)
SITC of above items set 2.00 220892.00 441784.00
Supplying, installation, testing and commissioning of 9 zone or above Door frame Metal detector for both ferrous and
non ferrous metals of nominal Size : 700 mm (W) x 1950 mm (H) x 500 mm (D) (minimum). To be equipped with audio
visual alarm with 2 line alphanumeric LCD display, height on person bar display (metal locator) and low battery
indicator. Should have a wide range of sennsitivity setting and fine tuning, adjustable in step to 250 levels, including a
4 level basic setting. The calibration to be adjustable manually nad automatically by built - in keypad. It should have
Intelligent traffic counter for calculating the number of people in and out also the alarm number with percentage
2 display. It should confirm to (1)Conform to relevant electric safety standard (Supported by Test Certificates from NABL
{India} or other accredited labs from the country of origin of the equipment). (2)The magnetic field should be as per
ICNIRP Guidelines (International Commission on Non Ionizing Radiation Protection). The references values for general
public are given in table VII of the ICNIRP Guidelines. (3)Should not be affected by external RF transmission and EMI.
(Supported by Test Certificates from NABL {India} or other accredited labs from the country of origin of the
A suitable control panel shall be provided to turn unit on, access and adjust setup and programming. The control
panel shall be used to turn the DFMD on. The unit should be ready to operate within ten seconds. The manual self-test
shall be activated at any time by pressing suitable control menu. The control panel shall be used to turn the DFMD
off, ensuring that all of the information and settings are stored in memory before shut down. The DFMD Control panel
should be tamper proof. All settings should be secured with a key lock. Further security should be accomplished with
a cabinet lock to prevent unauthorized access to physical cables, connectors & electronics.
The detector shall have a minimum of 9 zones of metal detection. These zones shall operate as individual detectors
and detect the presence of metal in their confined region. Zone display shall be on front panel with human symbol.
The zones shall be arranged in the following methodology: Top Left, Top Center and Top Right. Middle Left, Middle Nos 1.00 304679.00 304679.00
Center and Middle Right. Bottom Left, Bottom Center and Bottom Right.
The DFMD shall have a 90-270v operation SMPS Power Supply, Should be provided with internal battery back-up for
12 hours minimum operation in case of power cut. The DFMD shall have a remote control to operate the control
panel without using the buttons on the panel. The Remote shall have similar buttons as on the control panel to allow
similar operation.
The DFMD shall have a provision to interface to a Computer Network using the Ethernet connection. There shall be a
provision to interface multiple DFMD’s on the same network to monitor or control the detectors through Software.
Supply, installation, testing and commissioning of hand held metal detector of dimensions: Length: 400mm (Max),
Handle width: 45mm (Max), Body thickness: 35mm (Max), Search Probe Area: 150sq. cms (Min) and weight not more
than 325gms (Max) including batteries. The power Source shall be commercially available AA sized alkaline batteries
3 Volt (1.5x2). HHMD should run minimum 550 hrs on 10% detection rate. It should have and indication for following -
(a) Audio indication through piezo transducer.
(b) Single LED Visual indication for:
(i) POWER ON – Normal Light
(ii) METAL DETECTION – Bright Light
(iii) LOW BATTERY INDICATION – Flashing Light
The DFMD shall have a single push button operation. Its construction should be rugged and Impact resistant ABS
moulded casing. It should be able to detect Ferrous and Non Ferrous metals - Pistol.22 at min 6”, Cartridge.22 at min
2”, Razor Blade at min 1”. It shall have an automatic tuning to ensure detection of wide range of metals and alloys.
The sensitivity of HHMD should be adjustable using potentiometer. The potentiometer should be housed inside the
battery compartment to prevent accidental/unintentional change of sensitivity while in use.
The HHMD should be harmless to magnetic media, x-ray films and wearers of heart pacemakers. Laboratory
certificate from accredited laboratory shall be submitted.
The magnetic field should be as per ICNIRP Guidelines (International Commission on Non-Ionizing Radiation
Protection). The references values for general public are given in table VII of the ICNIRP Guidelines. Laboratory
certificate from accredited laboratory shall be submitted.
The HHMD shall have Water proof. Laboratory certificate from accredited laboratory shall be submitted.
The unit shall be able to satisfactorily function in temperature range from -10º C to 55º C and humidity of 95% non-
condensing at 40º C. Laboratory certificate from accredited laboratory shall be submitted.
Supply installation, testing and commissioning of retractable hydraulic bollard of height 1200 mm and diameter of
350mm - 360mm, thickness 20-22mm, ST 37 steel grade having a raising and lowering time of 4-6 secs. The foundation
depth of bollards shall be 2000mm , including drainage system. The bollard shall be crash tested on single bollard
and certified to meet PAS 68 standards. The bollard shall be K-12 crash rated. it should be tested for a life cycle of 10
4 million operations. The bollard shall have safety feature of photo sensor for human safety and loop detector for Nos 6.00 989292.00 5935752.00
vehical safety. The cost shall incllude the control panel of the bollard, which shall be placed in a range of meters.
The item shall be executed complete in all respects as per the satisfaction of engineer-in-charge, including all
associated civil, electrical and drainage works.
Supply,s installation, testing and commissioning of UVSS (under-vehical scanning system) to enable inspection of any
vehicle’s underside through a static composite image of the vehicle. It should produce multiple angular view of high
resolution 3D COLOR images of the complete under body of any vehicle passing over it using dual Area-scan
5 camera based technology and should be capable of handling vehicles moving at different speeds ranging from set 1.00 5644176.00 5644176.00
Zero (0) to 25 Km/hr, complete as per technical specifications.The item shall be executed complete in all respects as
per the satisfaction of engineer-in-charge, including all associated civil, electrical and drainage works.
Supply, installation, testing and commissioning of baggage scanners of size (minimum) 1380mm (L) X 740mm (W)
6 X1190mm (H) and tunnel opening of 500mm X 300mm (+/- 2%), complete as per the attached technical set 1.00 2646136.00 2646136.00
specifications and satisfaction of engineer-in-charge.
Supply, installation, testing and commissioning of teipod turnstile gate of cabinet heighr of 1200mm approx. and roter
arm height from ground to be 860 mm approx and shall have a 120 degree stop (tri-arm) with passage clearance for
500mm - 550 mm complete as per technical specifications and instructions of engineer-in-charge.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable
length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron
‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples
8 16.53 and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per METER 600.00 303.65 182190.00
direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile
strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks
shall be paid separately)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a
13 priming coat of approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works KG 6900.00 142.30 981870.00
E LANDSCAPING, PATHWAYS & EXTERNAL ELEMENTS
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of
2 16.82 unserviceable material to the dumping ground, for which payment shall be made separately and stacking of metre 25.00 32.40 810.00
serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc.,
disposal of unserviceable material to the dumping ground, for which payment shall be made separately and
stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
4 16.3 Supplying and stacking at site.
a 16.3.2 63 mm to 45 mm size stone aggregate CUM 120.00 1624.50 194940.00
b 16.3.3 53 mm to 22.4 mm size stone aggregate CUM 120.00 1837.25 220470.00
c 16.3.5 Over burnt (Jhama) brick aggregate 90 mm to 45 mm CUM 80.00 1041.15 83292.00
d 16.3.6 Stone screening 13.2 mm nominal size (Type A) CUM 80.00 1865.00 149200.00
e 16.3.7 Stone screening 11.2 mm nominal size (Type B) CUM 80.00 2065.75 165260.00
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness,
hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber,
applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate,
watering and compacting to the required density .
Laying water bound macadam sub-base with brick aggregate and binding material, earth etc. including screening,
6 16.5 sorting and spreading to template and consolidation with light power road-roller etc. complete.(payment for brick
aggregate and moorum etc. to be made separately)
16.5.2 Over burnt (Jhama) brick aggregate 90 mm to 45 mm CUM 360.00 725.60 261216.00
Supplying, stacking and Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the
surface and rolling.
16.6.1 With road roller/ hand roller SQM 870.00 21.80 18966.00
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements,
8 16.42 laid to required slope and camber in panels as required including consolidation finishing and tamping complete. CUM 87.00 7399.20 643730.40
Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature,
colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand
etc. all complete as per the direction of Engineerin- charge. (Old CC paver blocks shall be supplied by the
department free of cost).
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive
ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using
PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper
10 16.91 embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using
plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and
sweeping extra sand. complete all as per direction of Engineer-in-Charge.
16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. SQM 1083.25 1011.20 1095382.40
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to
the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making
joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making
drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb
edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm,
including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the
required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having
joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making
grooves etc. complete as per direction of Engineer-in-charge.
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in
stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete
(manure measured in stacks will be reduced by 8% for payment) :
15 2.4.1 Screened through sieve of I.S. designation 20 mm cum 31.8041 254.15 8083.01
16 2.4.2 Screened through sieve of I.S. designation 16 mm cum 20.00 290.70 5814.00
17 2.5 Rough dressing the trenched ground including breaking clods. sqm 1200.00 1.50 1800.00
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted
19 2.7 Fine dressing of the ground. sqm 1200.00 3.70 4440.00
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost
of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the
22 2.10 grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and
good earth shall be paid for separately).
2.10.1 In rows 5 cm apart in both directions sqm 1200.00 17.70 21240.00
Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure,
mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick
23 2.11 lawn free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if sqm 1200.00 34.40 41280.00
needed but excluding the cost of sludge or manure (the good earth shall be paid for separately).
P/F of FRP Sthamb/ structure of upto 4.0 mts complete as per approved design. The item to including cost of all
24 MR necessary support structure, scaffolding, fixing accessories, etc. NOTE: the surface area shall be measured for sqm 12.00 92685.15 1112221.78
Supply Installation, Testing and commissioning of 2MP 30 fps HD Outdoor IR IP bullet camera with 1/2.9‑inch CMOS,
Sensor pixels 1920 (H) x 1080(V), Sensitivity-0.24 lx (color) 0.05 lx (mono) ,IR range 60 mtrs, Dynamic range 84 db, True
day/night, Automatic Electronic Shutter, Video compression H.265 MP ; M-JPEG, White balance, BLC, H.265 quad-
streaming, Video Analysis ( Object removal , Loitering , Enter or Exit from the Field , Object Classification etc.), Privacy
Mask, Analog video output, Auto Varifocal Lens (zoom / focus) 2.8mm to 12 mm lens, Two-way, full duplex Audio,
Audio compression AAC, G.711, L16 (live and recording), 60 s pre-alarm recording Memory card slot support upto 256
GB , IP66 , ONVIF Profile S, CE, UL, FCC certified
Supply, installation & testing of 1080p HD Indoor IP Dome camera with 1/2.7-inch CMOS, Sensor pixels 1920 x 1080,
Sensitivity-0.24 lx (color) 0.05 lx (mono) , Dynamic range, True day/night, Automatic Electronic Shutter, Video
compression H.264 MP (Main Profile); M-JPEG, White balance, BLC, H.264 quad-streaming, Motion/tamper/audio
2 MR detection, Privacy Mask, Motion detection, Tamper alarm, Auto Varifocal Lens 3 to 10 mm lens, Built-in microphone, NOS 1.00 42046.00 42046.00
Two-way, full duplex Audio, Audio compression AAC, G.711, L16 (live and recording), Memory card slot (support upto
1TB), 3-axis adjustment (pan/tilt/ rotation), ONVIF Profile S, CE, UL, FCC Certified.
Supply Installation, Testing and commissioning of 32 IP channels with 320 Mbps incoming bandwidth,Maximum12 MP
IP camera support for view and playback,The recorder only supports IP cameras with a firmware version 6.30 or
higher.that use the latest H265/H264 highresolution video technology and state-of-the-art compression
techniques,Video inputs, audio inputs/output, and alarm inputs/ outputs a, Use the PC software or built-in web
3 MR application via a network for live viewing, playback, and configuration. A DIVAR Viewer App from Bosch for iOS and NOS 1.00 248965.00 248965.00
Android devices is available for: • live and playback viewing • recorder configuration • PTZ control With 4 Sata HDD
port , each port support 6 TB HDD , WITH 24 TB HDD , RJ-45 Ethernet Connection (10/100/1000 base-T), 2 USB (3.0), 1
USB (2.0), with PC software ,Vedio client, web client, iPhone Android , ONVIF as per UL FCC & UL, CE certified
Supply of Workstation latest Intel® i7 7th Generation, processor, Intel Chipset motherboard, 8GB DDR3 RAM, 500 GB
4 MR SATA HDD at 7200 rpm, Graphic card with 2 GB dedicated RAM with display ports/DVI/ HDMI port, DVD writer, with 32 NOS 2.00 184026.00 368052.00
" Monitor Giga LAN Card, Keyboard, optical Mouse.
5 MR Supply, Installation & Commissioning of Full HD 55" Display, with mounting brackets, complete as required NOS 1.00 87748.00 87748.00
Supply, Installation, Testing and commissioning of Managable 24 port Switch with Power on Ethernet (PoE) enabled,
10/100/1000, RJ45 Access ports with 2 SFP port and SM SFP modules complete as required.
Supply, Installation, Testing & Commissioning of 6 ports SM fully loaded Fiber LIU Box with all the required couplers,
adapter panels, pigtails complete in all respect.
8 MR Supply, Installation, Testing & Commissioning of OFC SM Patch Cord. NOS 6.00 4334.00 26004.00
9 MR Supply, Installation, Testing & Commissioning of 24 Port Fully Loaded Patch Panel NOS 1.00 19736.00 19736.00
Supply, Installation, Testing & Commissioning of 6U rack indoor/outdoor for switch Mounting with Fan and power Strip,
PDU, Hardware Mounting Kit Make: omnitech/Rittal/ DATA Rack
Supply, Installation, Testing & Commissioning of 12U rack for switch Mounting with Fan and power Strip, PDU, Hardware
12 MR Supply,Installation,Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. MTR 300.00 104.00 31200.00
13 MR Supply, Installation, Testing & Commissioning of Single mode 6 OFC ARMOURED cable. MTR 735.00 211.00 155085.00
Supply, Installation, Testing & Commissioning of CAT 6 STP Cable complete in all respect up to entire satisfaction
Engineer in charge of works.
Supply,Installation,Testing & Commissioning of laying of 25mm PVC conduit pipe ISI marked (Medium) recessed in wall
15 MR /ceiling etc. including cost of PVC bends, inspection box and all other material requiredto complete the job in all MTR 2000.00 85.00 170000.00
respect to the entiresatisfaction of Engineer-in-Charge of work.
Supply, Installation, Testing and Commissioning of 10 KVA UPS On Line With 30 Mins Backup with batteries, Battery
Racks, Connecting wires etc, complete in all respect.
17 MR Supply,Installation ,Testing and Commissioning of Junction Box NOS 8.00 1668.00 13344.00
Supply, Installation, Testing and Commissioning of Ethernet media converter FCC Class B, CE, RoHS, Pure Networking
Copper to Fiber Media Converter - 10/100/1000BASE-TX to 1000BASE-LX Single mode SC, 1310-nm, up to 20-km,s,
POWER Media converter: 5 VDC, 2.5 W, flow control for full-duplex mode with all the basic necessories required for
Supply, Installation, Testing and Commissioning of Network Switch, 24 Port Smart Managed Gigabit Layer Switch with
4 Ports 10G SFP+ Ports, min 11 Web languages, QoS enablement, and Advanced Layer-2 w/Lite Layer-3 features.
19 MR switches support 24 or 48 x 10/100/1000BASE-T ports, with each switch also supporting an additional 4 x 10G SFP+ ports NOS 4.00 27029.00 108116.00
for optical connections using multimode or single-mode SFP transceivers
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT DAIC.pdf
Tender Document
BOQ DAIC.pdf
Tender Document
SCC DAIC.pdf
Tender Document
TECHNICAL SPECIFICATIONS DAIC.pdf
Tender Document
Drawing DAIC.pdf
Tender Document
GCCamendupto15_merged.pdf
Tender Document
InstructiontoBidderforonlineBidSubmission.pdf
Tender Document
corrigendum-485-Corrigendum II .pdf
pdf • 0.42 MB
corrigendum-455-Corrigendum_ I.pdf
pdf • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .