Loading…
Loading…
Tender Value
₹3.8 Cr
EMD Value
₹7.6 L
Closing Date
23 Jun 2026, 3:30 pm7d left
Chandeshwar Ram
EENORTH
Sikh Heritage, Daroga Rai Path, Patna
Chandeshwar Ram
EENORTH
3. TOURISM DEVELOPMENT OF MATA SATI TEMPLE LOCATED AT DHRUVGAMA IN KALYANPUR BLOCK OF SAMASTIPUR DISTRICT.
133967
03/E-TENDER/BSTDC/SBD/2026-27gr03matasati
Open Tender
CIVIL
Patna
• NAME OF THE BIDDER
• CONTACT DETAILS OF BIDDER
• AADHAR DETAILS
• PAN DETAILS
• GST DETAILS
• MOBILE NO. & E-MAIL
CIVIL
ITEM RATE
L1
1
22 documents required · 22 mandatory
₹10,000
Processing Fee: 5900
₹7.6 L
Office of Chief Engineer, BSTDC, Patna
15 Jun 2026
15 Jun 2026
24 Jun 2026
15 Jun 2026
23 Jun 2026
15 Jun 2026
17 Jun 2026
BIHAR STATE TOURISM DEVELOPMENT CORPORATION LIMITED
Technical Sheet
Name of Work TOURISM DEVELOPMENT OF MATA SATI TEMPLE LOCATED AT DHRUVGAMA IN KALYANPUR BLOCK OF SAMASTIPUR DISTRICT. Cost of Work as per BOQ(Rs in Lakhs) 379.98851 Time of Completion in months 12 ALL COLOURED CELL TO BE FILLED ACCORDINGLY
Sactioned Amount 145033000 Date of Sanction 2026-04-08T00:00:00Z Date of Tender 2026-04-24T00:00:00Z
Sl No. Items Requirement Cl. No. Name of the Contractor
Address of the Contractor
1 Registration No.
2 Bid Validity Bids shall remain valid for a period not less than 120 days after the deadline date. A Bid valid for a shorter period shall be rejected by the Employer as non-responsive 120 Days 15.1 Bid validity periods In days
3 Bid Security (A) Online mode i.e. internet payment gateway (credit/ debit card), Net Banking, NEFT/ RTGS 16.1 Amount To be entered (Rs in Lakhs)
(B) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given (If issued from any bank outside state will be converted to any bank within the state before executing the agreement. Amount To be entered (Rs in Lakhs)
Bid Security Amount - (Rs. In Lakhs) 7.6 Bid Security Amount - Rs.
4 (i) Legal Status of Bidder. 4.3(a)
(ii) Place of Registration.
(iii) Principal place of Business
(iv) Power of attorney of signatory Bid Attached or Not 4.2(iv)
5 Total value of civil engineering construction work performed in last five years. 1. Annual Financial Turn Over usually not less than 50 % of the estimated annual payments under the contract (Rs in Lakhs) APPENDIX to ITB
2020-21 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.469
2021-22 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.36
2022-23 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.26
2023-24 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.166
2024-25 Amount To be entered (Rs in Lakhs)
Escalation Factor= 1.08
6 Work Experience of Similar nature Satisfactory completed atleast one similar work of value not less than 50 % of estimated value of contract (Rs in Lakhs) 4.5 (b) Amount To be entered (Rs in Lakhs)
7 Minimum Quantities of work done as prime contractor in any one year during last five years. Items Unit Total Quantity 4.5 ( c )
Brick Work cum 171.1 Value to be entered in unit cum
Electrical Works Rs. 3417920 Value to be entered in Rs.
PHE Work Rs. 1600916 Value to be entered in Rs.
PCC&RCC cum 387.4 Value to be entered in unit cum
Steel MT 33.2 Value to be entered in MT
Flooring Work. (Any Stone, Granite, Kota, Sand Stone etc.) sqm 980.25 Value to be entered in unit sqm
8 Bidding Capacity More than the total Bid value of present work = A*N*3-B=Rs. ____.Where A = Maxm. Value of work executed in any one yr during last 5 yrs. N= Nos of years for completion of works. B=Value of existing commitments & ongoing works to be completed in period (Rs in Lakhs) 4.4
9 (a) Existing commitments and ongoing works Amount To be entered (Rs in Lakhs)
(b) Work for which Bid already submitted Amount To be entered (Rs in Lakhs)
10 Availability of key items of Contractor's Equipment Type of Equipment/Maximum age No. Required Nos. Max. Age Page-17 Nos./ Max. Age
Plate Vibrator 1 5
Niddle Vibrator 2 5
Water tankar 1 5
Steel shuttering 1500sft 5 to 7
Concrete Mixture 1 5
11 Key Personnel Personnel/Qualification/Contract Package Size (Rs. 02 to 10 Crore) Page-18 Name of the Personnel and Experince in years
Site Engineer/ B.E. Civil + 07 Years Exp. (3 years in Building Construction) or retired A.E. 1 No.
Plant Engineer/ B.E. Civil + 05 Years Exp. or Dip. Electrical + 07 Years Exp. or Retired J.E. 1 No.
Site Supervisor/ Fresh Graduate in Civil or Diploma Civil + 03 Years Exp. or retired I.T.I Holder. 1 No.
12 Evidence of accesses to Financial Resources Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (Not more than 3 months old). (Rs in Lakhs). 4.2(i) Amount To be entered (Rs in Lakhs)
13 Proposed methodology and programme of construction. Justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion as per milestones. (Attached or not) 4.3(l)
14 Litigation History Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
15 Affidavit Regarding statements made in the required attachments are true and correct. Page-24
16 Undertaking Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. (Rs in Lakhs). 4.2(ii)
17 NOC for Debar (Affidavit)
BIHAR STATE TOURISM DEVELOPMENT CORPORATION LTD.
(A GOVERNMENT OF BIHAR UNDERTAKING)
TOURISM DEVELOPMENT OF MATA SATI TEMPLE LOCATED AT DHRUVGAMA IN KALYANPUR BLOCK OF SAMASTIPUR DISTRICT.
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Mobile Number
NIT - 03/E-TENDER/ BSTDC/SBD/2026-27 (GR 03)
Sl No. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.) 33562404.00245467
2 Total Non-Schedule Amount (Rs.) To be Quoted !
TOTAL AMOUNT Rs. 37998851.00245467
Development of Satimata Sthan, Dhruvgama, Kalyanpur, Samastipur, Bihar.
Bill of Quantity
Items Covered Under BCD-SOR-2022, effective from 01.01.2022/ns
Sl. No Sl. No./ Code. SOR- Description of Work Unit. Qnty Rate Amount(Rs)
2.29 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cmdeep and disposal or rubbish ,lead up to 50 m lift up to 1.5 m
0.0 Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed.
3 2.28 Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. Cum 3438.393 287.3 987850.3089000001
0.0 Concrete Work
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
4 4.1.6 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) Cum 244.403 3279.8 801592.9594
0.0 Reinforced Cement Concrete Works
0.0 Centring and shuttering including strutting, propping etc. and removal of form for:
5 5.9.1 Foundations, footings, bases of columns, etc., for mass concrete. Sqm 252.50000000000003 211.6 53429.00000000001
6 5.9.2 Wall (any thickness) including attached pilasters Butteresses ,plinth and string courses etc Sqm 61.60000000000001 375.1 23106.160000000003
7 5.9.3 Suspended floors, roofs, landings, balconies and access platform Sqm 784.2090000000001 437.5 343091.4375
8 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 546.8600000000004 404.7 221314.24200000014
9 5.9.6 Columns, Pillars, Piers, Abutments, Post and struts Sqm 612.18 494.4 302661.79199999996
5.22 Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cemen tcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength and admixtures in recommended proportions as per IS: 9103 to accelerate, reinforcement, durability as per direction of Engineer-incharge.
15 5.33.1 All work upto plinth level Cum 288.69350000000003 5063.4 1461770.6679
16 5.33.2 All work from plinth level upto floor V level. Cum 225.0193500000001 5863.2 1319333.4529200005
6.1C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
17 6.1.14C Cement mortar 1:6 (1 cement: 6 coarse sand ) - 250 mm th Brick work Cum 340.65725 4923 1677055.64175
6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level.
18 6.45.1 Cement mortar 1 : 3 (1 cement : 3 coarse sand) Cum 4.971874999999999 723 3594.665624999999
0.0 Flooring Works
19 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I. Sqm 2314.4800000000005 283.3 655692.1840000001
8.13 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
20 8.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. Sqm 124.38 3605.2 448414.77599999995
11.41A Providing and laying Vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
11.41A.3 Glazed Vitrified tiles Matt/ Antiskid finish of size.
11.41A.1 Double charge vitrified tile polished finish of size
AT Ground Floor LVL
23 11.37A Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the anufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Sqm 128.054 663.8 85002.24519999999
0.9 Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel einforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).
0.9 Extra over item No. 23.3 for providing additional bulb in under reamed piles, under specified dia meter (Only the quantity of extra bulbs are to be paid).
26 10.2 Structural steel work riveted or bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved ateef primer all complete. Kg 3543.2000000000003 95.4 338021.28
27 10.18 Providingand fixing circular/hexagonal cast iron orM.Ssheet box for ceiling fan clamp140mm internal dia, 73mmheight, 5mm thick rim bottomandtoplids,1.5mmthickM.Ssheetwithitstopsurfacehackedforproperbondingtoplidshallbescrewedintothecastironboxbymeansof.3mmdiaroundheadedscrews,onelockathecorners.Clampsshallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing. Num 60 165.4 9924
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
28 9.48.1 Fixed to steel windows by welding. Kg 1045.4399999999998 144.5 151066.08
10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required.
29 10.32.2 In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works. Kg 6118.2 114.6 701145.72
0.0 Plaster & Finishing Works
13.11 12 mm cement plaster of mix
13.24 6 mm cement Plaster to ceiling of mix
31 13.24.2 1:4(1 cement;4 coares sand) Ground And first floor Sqm 772.2090000000001 125.6 96989.4504
32 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm 3216.3639999999996 105.4 339004.7656
13.46A Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade.
33 13.46A.1 New work (Two or more coats applied @ 1.43 ltr / 10 sqm. Over and including base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm). Sqm 1872.4125 132.5 248094.65625
13.48 FinishingwithDeluxeMulti surfacepaint systemfor interiors an exteriors using Primer as per manufacturers specifications.
34 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @0.75 ltr /10 sqm. Sqm 1343.9515 117.3 157645.51095
0.0 Stone Works
11.3 40 mm thick fine dressed stone flooring over 20 mm (average) thick base with joint finished fiush:base 1:5 (1 cement: 5 coarse sand )with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.
0.0 Roofing Work
36 12.48 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately Sqm 76.93 292.1 22471.253000000004
0.0 Wood work & Pvc work
0.000 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge
37 9.117.2 Extruded section profile size 42x50 mm Sqm 131.4 251.8 33086.520000000004
0.9 Providingwoodworkinframesofdoors,windows,clerestorywindowsand other frames,wrought framedand fixed inpositionwithholdfast lugsor with dash fasteners of required dia& length ( hold fast lugs or dash fastener shall be paid for separately).
0.0 Providingand fixing glazed shutters for doors, windows and clerestory windowsusing4mmthick float glasspanes including ISImarkedM.S. pressed butt hinges bright finished of required size with necessary screws.
9.9.1 Second class teak wood
40 9.118.2 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-incharge. Sqm 37.31999999999999 1846.9 68926.30799999999
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
41 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 2 33603.4 67206.8
0.0 Dismantling & Demolishing work
42 15.3 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead: Cum 18 1411.2 25401.600000000002
43 15.4 Demolishing R.B. work including stacking of steel bars and disposal of unserviceable material within 50 metres lead: Cum 12.599999999999998 1264.1 15927.659999999996
44 Add 5.36% GST on SOR item As Per BCD 1158296.2064990918
49 Add 5.36% GST on SOR item As Per BCD 233026.67405523392
SANITARY FIXTURES
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
50 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps nos 11 2764.4 30408.4
51 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. nos 11 1068.5 11753.5
17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
52 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid nos 3 4230 12690
17.1 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
53 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests nos 8 4470.9 35767.2
17.4 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
54 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern nos 3 3723.2 11169.599999999999
55 17.72 Providing and fixing white vitreous china flat back or wall corner type lipped roviding and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms nos 4 204.7 818.8
8.1 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and
56 8.10.1 White Agaria Marble Stone sqm 35 3061.2 107142
57 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. nos 12 146.3 1755.6000000000001
0.00_ Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
17.60.1 100 mm inlet and 100 mm outlet
58 17.60.1.1 Sand cast iron S&S as per IS: 3989 nos 12 1129.2 13550.400000000001
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.35 Providing and fixing soil, waste and vent pipes :
61 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 Metre 95 978.3 92938.5
17.38 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
62 17.38.1.1 Sand cast iron S&S as per IS - 1729 each 15 530.7 7960.500000000001
17.39 Providing and fixing plain bend of required degree..
63 17.39.1.1 Sand cast iron S&S as per IS - 1729 each 15 457.2 6858
17.41 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :
64 17.41.1.1 Sand cast iron S&S as per IS - 1729 each 15 1038.8 15582
17.42 Providing and fixing double equal plain junction of required degree.
65 17.42.1.1 Sand cast iron S&S as per IS - 1729 each 15 861.2 12918
17.43 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
66 17.43.1.1 Sand cast iron S&S as per IS - 1729 each 15 671.2 10068
17.44 Providing and fixing single equal plain junction of required degree :
67 17.44.1.1 Sand cast iron S&S as per IS - 1729 each 15 580.2 8703
17.53 Providing and fixing sand cast iron S&S off sets as per IS-1729
17.53.1 76 mm off sets
17.53.1 114 mm off sets
69 17.53.2.2 With 100mm dia pipe Each 15 560.1 8401.5
17.53.3 152 mm off sets
70 17.53.3.2 With 100mm dia pipe Each 15 666.3 9994.5
17.55 Providing and fixing door piece, insertion rubber washer 3 mm thick, bolts & nuts complete.
71 17.55.1.1 Sand cast iron S&S as per IS-1729 Each 15 711.3 10669.5
17.56 Providing and fixing terminal guard:
72 17.56.1.1 Sand cast iron S&S as per IS-1729 Each 15 392.9 5893.5
17.57 Providing and fixing collar
73 17.57.1.1 Sand cast iron S&S as per IS-1729 Each 15 399.6 5994
17.58 Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter.
17.59 Providing and fixing M.S stays and clamps for sand cast iron / centrifugally cast (spun) iron pipes of diameter:
17.34 Providing and fixing toilet paper holder :
77 17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. nos 14 886.2 12406.800000000001
17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required :
78 17.9.1 White glazed fire clay kitchen sink of size 600x450x250 mm 2 2778 5556
EXTERNAL & INTERNAL WATER SUPPLY
18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
79 100 mm diameter nos 2 500.4 1000.8
18.58 Providing and fixing PTMT grating of approved quality and colour.
18.58.1 Circular type
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
81 18.8.1 15 mm nominal outer dia Pipes Metre 30 278.2 8346
82 18.8.2 20 mm nominal outer dia Pipes Metre 45 350.8 15786
83 18.8.3 25 mm nominal outer dia pipes Metre 25 463.1 11577.5
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
84 18.7.2 20 mm nominal outer dia Pipes Metre 45 233.9 10525.5
85 18.7.3 25 mm nominal outer dia Pipes Metre 55 317.3 17451.5
86 18.7.4 32 mm nominal outer dia Pipes Metre 35 395.2 13832
87 18.7.5 40 mm nominal outer dia Pipes Metre 35 538.4 18844
88 18.7.6 50 mm nominal outer dia Pipes Metre 220 791 174020
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
89 18.17.1A 20 mm nominal bore. nos 10 465.4 4654
90 18.17.1 25 mm nominal bore nos 10 532.3 5323
91 18.17.2 32 mm nominal bore nos 5 589.9 2949.5
93 18.17.4 50 mm nominal bore nos 8 878.2 7025.6
94 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per liter 4000 9.7 38800
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
95 18.18.1 15 mm nominal bore nos 50 348.9 17445
0.00_ Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts,nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
96 18.60.1 50 mm dia nominal bore each 3 3533.7 10601.099999999999
97 18.65 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. Each 12 96.8 1161.6
18.75 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
98 18.75.3 25mm nominal bore, weighing not less than 62 gms each 20 100.6 2012
99 18.77 Cutting holes up to 15 x 15 cm in R.C.C floors and roofs for passing drain pipe and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4(1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. Each 20 217.1 4342
18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
100 18.53.1 15 mm nominal bore nos 25 500.4 12510
101 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : nos 20 434.2 8684
18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
102 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 100A No 12 1177.9 14134.800000000001
2.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:
2.10.1 All kinds of soil
103 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia Metre 510 391.7 199767
12.78 Providing and fixing on wall face PVC (working pressure 4kgf per sqm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
104 12.78.2 110 mm diameter Metre 70 257.5 18025
12.79 Providing and fixing on wall face PVC moulded fitting / accessories for rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
12.79.1 Coupler
12.79.2 Single pushfit Coupler:
12.79.3 Single tee with door
12.8 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S screws of required length, including cutting brick work and fixing in cement mortar 1:4( 1 cement: 4 coarse sand) and making good the wall etc. complete.
110 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 7 47.9 335.3
19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
19.4.1 100x100 mm size P type
112 19.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 3 1860.6 5581.799999999999
0.0 Providing, laying and jointing glazed stoneware pipes class 'SP1' with stiff mixture of cement mortar in the proportion of 1:1(1 cement: 1 fine sane) including testing of joints etc. complete.
113 19.1.2 150 mm diameter Metre 3 464.3 1392.9
0.0 Providing and laying cement concrete 1:5:10 ( 1 cement: 5 coase sand: 10 graded stone aggregate 40 mm nominal size) all-round S.W pipes including bed concrete as per standard design.
114 19.3.2 150 mm diameter S.W. pipe Metre 3 311.4 934.1999999999999
19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
116 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 7 7914.7 55402.9
117 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be isible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. each 40 310.9 12436
19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
118 19.19.3.1 Circular shape 560 mm internal diameter each 9 985.1 8865.9
19.27 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
119 19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 20 3743.3 74866
19.29 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame and vertical grating complete as per standard design :
120 19.29.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 7 7186 50302
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
121 19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 2 7090 14180
RAIN WATER HARVESTING & TUBEWELLS
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
24.1.1 All types of soil
0.0_ Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
123 24.3.3 200 mm nominal size dia mtr 150 940.8 141120
124 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. cum 10 1188.9 11889
125 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 28 1195.6 33476.799999999996
126 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. cum 10 1195.6 11956
127 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. cum 10 1343.2 13432
24.1 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. (All types of soil)
24.2 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (UPVC) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
131 24.3.2 150 mm nominal size dia M 300 660.1 198030
132 24.3.1 100 mm nominal size dia M 300 546.1 163830
24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC (UPVC) medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
133 24.4.1 100 mm nominal size dia M 300 573.1 171930
24.13 Supplying the following fittings & fixing the same in position as per approved lowering assembly and strata chart including providing all equipments and welding the same on process of lowering the assay etc. all complete as per S/D of E/I.
24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
135 24.14.2 (b) 150 mm dia M.S. Clamp 1.6 M long (one Pair) No. 2 1531.4 3062.8
24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
136 24.15.1 100mm dia & 6mm thick M.S. well shoe plug No. 2 228.3 456.6
137 Add 5.36% GST on SOR item As Per BCD 142346.11031466664
Wet Riser & Sprinkler System for Fire safety
4 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
(b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads
7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
139 7.6 80mm nominal dia Rmt 1 951 951
140 7.7 100mm nominal dia Rmt 50 1316 65800
9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
141 9.1 Single headed Gunmetal Set 3 7245 21735
11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
144 13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. each 1 1236 1236
14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
15 Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
147 0.0 Gunmetal Set 6 5206 31236
17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. "Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket."
18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
149 0.0 Gunmetal Set 3 2393 7179
19 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
150 0.0 2 way-100 mm dia M.S. Pipe Set 1 6331 6331
151 20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. Set 1 17707 17707
152 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per liter 25000 9.7 242499.99999999997
SUB HEAD-I :-WIRING POINTS
1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch ,modular plate suitable size G.I box etc as per requred.
154 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Metre 1400 309 432600
0.0_ Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
155 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre 1200 246 295200
1.21 Supplying & fixing of following size medium class PVC conduit along with accessories in surface/ recess including cutting of wall and making good the same in case of recessed conduit as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modulor plat & switch box/ including connections but excluding modular plate etc .as per required etc.
158 1.24.1 5/6 amps switch Each 25 82 2050
159 1.24.3 15/16 amps switch Each 50 139 6950
160 1.24.4 3 pin , 5/6 amps socket outlet Each 25 112 2800
161 1.24.5 6 pin , 15/16 amps socket outlet Each 50 183 9150
162 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required. Each 35 358 12530
163 1.26 Supplying and fixing modular blanking plate on the existing modular plate & metal box excluding modular plate, etc. as required. Each 30 34 1020
1.27 Supplying and fixing following size/ modules, Gl box along with modular base and cover plate for modular switches in recess etc as required.
164 1.27.1 1 or 2 Module (75mm X 75mm) Each 10 234 2340
168 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. Each 15 64 960
169 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. Each 20 80 1600
1.59 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc as required.
SUB HEAD-2 :-SWITCHEARS & DB'S
2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required'
2.7 Providing and fixing following capacity four pole ON-load panel mounted changeover switches inside the existingcubical panel board including drilling holes in cubicle panel, making connections etc. as required.
2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator)
173 2.9.3 8 way ( 4 + 24 ), Double door, horizontal type Each 2 6199 12398
2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required'
174 2.12.1 6 A to 32'A, Single pole Each 58 237 13746
2.13 Supplying and fixing following rating, 2401475 volts, "C"curve, miniattlre circuit breaker suitable for lnductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
175 2.13.1 6 A to 32 A, double pole Each 1 667 667
176 2.13.3 40 A to 63 A, double pole Each 7 1198 8386
177 2.13.4 40 A to 63 A, four pole Each 2 2324 4648
178 2.19 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Each 10 1513 15130
SUB HEAD-3 :-EARTHING
179 3.2 Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. set 5 6323 31615
180 3.4 Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. set 1 6884 6884
181 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. set 1 13721 13721
182 3.7 Supplying and laying 6 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with Gl thimble as required. Meter 500 37 18500
183 3.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of brass nut bolt and & spring washer spaced at 50mm) Meter 40 1026 41040
184 3.9 Supplying and laying 25 mm X 6 mm G.t. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.l. nut bolt & spring washer spaced at 50 mm) Meter 150 133 19950
SUB HEAD-IV :-LIGHTNING CONDUCTOR
185 4.1 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having singte prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. set 1 1056 1056
186 4.4 Jointing copper/ G.l. tape (with another copper/ G ltape,base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. set 1 81 81
187 4.6 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) M 30 559 16770
SUB HEAD-5 :-LED LUMINAIRES
5.7 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
190 5.9 Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required. Each 60 2663 159780
191 5.13 Supplying and fixing post top / gate light (width 250/300mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( Butwithout lamp) Each 50 1399 69950
5.15 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required
6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
193 6.7.7 20 watt LED lamp Each 50 267 13350
SUB HEAD-6 :- MISCELLANEOUS & MV/HT CABLE LAYING
0.0_ Laying of one number additional PVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
195 7.2.2 Above 35 sq. mm and upto 95 sq. mm Metre 200 232 46400
0.0_ Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
SUB HEAD-7 :- LIGHTING POLE, FAN & PANEL
199 8.9 Supply and fixing pole mounted junction box/fuse box for single phase/ 2 core low wattage street light pole with all accessories and connection etc. as required. Each 10 825 8250
200 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 35 2482 86870
8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
SUB HEAD-8 :- CIVIL ITEMS
9.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part ll complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. ln the existing trench, complete as required.
202 9.15.5 200 mm dia (OD-200 mm & lD-175 mm nominal) metre 300 646 193800
9.16 Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
203 9. 16.1 For 4 metre pole (500mm X 500mm X 1000mm) Each 50 3505 175250
204 9.16.2 For 6/7 metre pole (500mm X 500mm X 1400mm) Each 10 4398 43980
BILL OF QUANTITY FOR NON SOR ITEMS
Development of Satimata Sthan, Dhruvgama, Kalyanpur, Samastipur, Bihar.
Bill of Quantity
(Each Item rate must be filled)
Sl. No Sl. No./ Code. SOR- Description of Work Unit. Qnty Amount(Rs)
1 NS-7/Rate analysis NS-5 Supply Installation, commissioning and testing of single phase 2H.P. submersible pump set having discharging capacity 3 Ips at a total head of 30 meter(approx) of KSBj Kirloskaror equivalent make with all accessories& fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & (i) 50 mm dia x 3 mtrs long medium classG.I column pipe both end thread and one end socketed- 6(six)nos (ii) lx3x2,5 mm' flat copper conductor submersible cable -40 (forty) mtrs. (iii) 50 mm dia union socketlIonel no. (iv) 65 mm dia x 250 mm long G.!. nipple- 1(one) no. (v) 50 mm dia G.I Elbow-l(One) no. (vi) 50 mm dia M.S, clamps-2(Two) Pairs. (vii) 50 mmx 250 mm long G.I nipple- lIOnel no. (viii) Tube well cap for T/WelllIonel no. (ix) 50 ":l~ia x 65 mm dia Each 2
Supply Installation, commissioning and testing of floor mounted outdoor type loT feeder pillar single phasestarter controll pannel operated on 220V, 3 phase, 50 cis for 3 HP Submersiblepump set made of MSsheet (minimum 2 mm thick) duly spray power coated painting with following accessoriesmade of M.Ssheet ( minimum 2mm thick) duly spray powder coated painting with following accessories (i) 90-220 V range single phase7. 5 KVA automatic voltage stabilizer make- Sen& Pandit/ Vertex/lSI marked If any. 1No. (ii) Suitablesinglephasestarter control panelfor abovemotor of BCH /L& Tmake-1(one) no. 2
Supplying& fitting 2.5 mm' copper service cable from power point from nearest source up-toIpumping station .. 150
Providing all materials and labour required lor doing earthing station with G.I earth pipe of 40 mm dia x 4.5 mtrs 20fts. long G.I pipe including accessories excavation of earth , providing masonry enclosure with Coverplate having locking arrangementand watering pipe etc.with salt, charcoal,etc.as per IE & IS specification 2
2 NS-1 Providing Supply of Grape Supporting Bars, 12 mm diameter, 2.4 m long, fabricated from mild steel with U-bend at ends for wire holding, surface painted (2 coats red oxide + 1 coat enamel), suitable for trellis grape farming system. Nos 4
3 NS-2 PROVIDING FIXING TESTING COMMISSIONING Delta Brass Robe Hook | Coat Hook | Bathroom Accessories (Chrome Finish, Wall Mounted) testing of joints complete as per direction of Engineer in Charge. Nos 14
4 NS-3 Providing Supply and place PARASNATH brand stainless steel perforated dustbin, capacity 10–15 liters, made from high-grade SS 202/304 stainless steel with a matt finish. Dustbin shall have a perforated body design for ventilation, be corrosion-resistant, durable, and suitable for indoor use in offices, institutions, or commercial spaces. Approximate dimensions: 250mm diameter x 300mm height. Smooth edges and anti-skid base. Sample to be approved prior to supply. Nos 11
5 NS-4 Providing & fixing of approved coloured verticle type hot water 25 ltr geysers. The inner container shall be made of copper sleeve with PUF insulation between inner and outer container, element pipe and heating element, pressure cum vaccume release, thermostat and thermal cutout arrangements and fusible plug. The outer container shall be of powder coated finish with all other accessories including fixing brackets complete as required. Nos 2
6 NS-5 Supplying and fixing of shower diverter made of brass/chrome-plated, suitable for concealed installation, 2-way/3-way function, including necessary fittings, cutting, threading, and making connections complete in all respects as per direction of Engineer-in-Charge. Nos 2
7 NS-1 Transportation of drilling plants, developing equipments & all other required tools and M/c by and suitable mechanical means including all cost of loading, unloading, placing at work site and back after completion of work as per S/D of E/I Each 4
8 NS-2 Supplying all materials and labours for arrangement for additional water required during the drilling period for 70 Hrs & site clearance & leveling etc. And providing the soap duster etc. to staff engaged in drilling etc. all complete work as per specification & direction of E.I. Each 5
FIRE EXTINGUISHERS
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.
9 NS-4 ABC powder type fire extinguisher of 6 Kgs. Capacity, with initial filling (Mono Ammonium Phospate Powder) in brand new cylinder with powder coated finish, Stored Pressur type, Pressure Gauge, Controllable discharge mechanism with Hose & Nozzle , confirming to IS:15683:2008. Nos. 3
10 NS-5 Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, Co2 gas as per IS 15222 with controll discharge mechanism fitted with Hose & Horn applicable on Class B fire rating 21B confirming to IS: 15683:2008. CO2 Cylinder as per IS 7285 with ISI mark. Nos. 3
SUB HEAD-11 :- NS ITEMS LIGHTING
11 NS-1 SITC of Step light with 3W,h aving IP65 ProtectionRating, CCT: 3000K / 5600K, Aluminum Alloy Material, Body Color: Telegrey. Input Voltage: AC100-230V Each 30
12 NS-2 SITC of 9W Mono color Spike light, Protection Rating : IP66, complying to BIS standard "IS 10322 (Part 5/Sec 1): 2012" and having CE certification against standard "Low Voltage Directive & Protective Equipment - EN 60598-1:2015", and "Electromagnetic Compatibility Directive - EN 61547: 2009", Mounting Structure : Spike for fixing the lights. Power consumption : 9W, CCT : 1800/3000/4000/6000K, (as per the design approval) Optics : PMMA with holder, Beam Angle : 15º/25º/45º/60º, Control : ON/OFF, Body : Die casted / extruded aluminium with embossed manufacturer logo, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : AC110-230V, Surge Protection : Inbuilt surge protection 2KV- 4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK05, IP66, from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Each 19
13 NS-3 SITC of 9W Mono color Spot light, Protection Rating : IP66, complying to BIS standard "IS 10322 (Part 5/Sec 1): 2012" and having CE certification against standard "Low Voltage Directive & Protective Equipment - EN 60598-1:2015", and "Electromagnetic Compatibility Directive - EN 61547: 2009", Mounting Structure : Adjustable wall mount yoke arrangements for fixing the lights. Power consumption : 9W, CCT : 1800/3000/4000/6000K, (as per the design approval) Optics : PMMA with holder, Beam Angle : 15º/25º/45º/60º, Control : ON/OFF, Body : Die casted / extruded aluminium with embossed manufacturer logo, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : AC110-230V, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK05, IP66, from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Each 5
NS-4 Feeder Pillar
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of Distribution Panels fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) GI sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry,300 mm MS painted stand and standing covering from 3 sides, IP 55 double door with canopy ,dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided at the bottom of the panels with appropriate stand etc. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels.(Make AAA Switchgear, Indiatech panel, Neptune india)
Feeder Pillar (For External Landscape lighting) IP 55 for outdoor Protection
63 Amps 4 pole MCCB
100 Amps TPN Aluminium bus bars with heat shrinkable insulation sleeve. - 1 Set
63 Amps two pole MCB incomer with 63 Amps DP contactor 0-24 hours timer auto / manual and outgoings including 10 No. 10/16/20 Amps SP MCB with separate neutral link of each phase- 1 set (50%)
40 Amps DP MCB with 32 amp industrial sockets - 2 sets
63 Amps 4 Pole MCB - 5 set
14 Feeder Pillar for external / landscape lighting as described above Each 1
NS-5 Solor PV Module
Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. (with a 5-year product warranty)
15 Above 1 kWp and up to 10 Kwp Each 10
NS-6 Solar Street Light (Make ielecssol)
Supply Installation testing commissioning of All-in-one Solar Street Light (Luminaire) Model Polaris Product Specification:- 30W LED, 120W-Mono Panel, 12.8v 54Ah Battery, 6 MTR GI tubular pole od-76 mm thickness 3mm with complete accessories. Warranty: a) Solar PV Modules : Solar PV Modules will be warranted up to 90% power output for 10 years and 80% power output for 25 years from the date of installation. b) LED Light : 3 years Warranty c) Lithium Battery: Battery will be warranted for 5 years.
16 Above 1 kWp and up to 10 Kwp Each 30
BIHAR STATE TOURISM DEVELOPMENT CORPORATION LTD.
(A GOVERNMENT OF BIHAR UNDERTAKING)
TOURISM DEVELOPMENT OF MATA SATI TEMPLE LOCATED AT DHRUVGAMA IN KALYANPUR BLOCK OF SAMASTIPUR DISTRICT.
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Mobile Number
NIT - 03/E-TENDER/ BSTDC/SBD/2026-27 (GR 03)
Sl No. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.) 33562404.00245467
2 Total Non-Schedule Amount (Rs.) To be Quoted !
TOTAL AMOUNT Rs. 37998851.00245467
Development of Satimata Sthan, Dhruvgama, Kalyanpur, Samastipur, Bihar.
Bill of Quantity
Items Covered Under BCD-SOR-2022, effective from 01.01.2022/ns
Sl. No Sl. No./ Code. SOR- Description of Work Unit. Qnty Rate Amount(Rs)
2.29 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cmdeep and disposal or rubbish ,lead up to 50 m lift up to 1.5 m
0.0 Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed.
3 2.28 Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. Cum 3438.393 287.3 987850.3089000001
0.0 Concrete Work
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
4 4.1.6 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) Cum 244.403 3279.8 801592.9594
0.0 Reinforced Cement Concrete Works
0.0 Centring and shuttering including strutting, propping etc. and removal of form for:
5 5.9.1 Foundations, footings, bases of columns, etc., for mass concrete. Sqm 252.50000000000003 211.6 53429.00000000001
6 5.9.2 Wall (any thickness) including attached pilasters Butteresses ,plinth and string courses etc Sqm 61.60000000000001 375.1 23106.160000000003
7 5.9.3 Suspended floors, roofs, landings, balconies and access platform Sqm 784.2090000000001 437.5 343091.4375
8 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 546.8600000000004 404.7 221314.24200000014
9 5.9.6 Columns, Pillars, Piers, Abutments, Post and struts Sqm 612.18 494.4 302661.79199999996
5.22 Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
5.33 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cemen tcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength and admixtures in recommended proportions as per IS: 9103 to accelerate, reinforcement, durability as per direction of Engineer-incharge.
15 5.33.1 All work upto plinth level Cum 288.69350000000003 5063.4 1461770.6679
16 5.33.2 All work from plinth level upto floor V level. Cum 225.0193500000001 5863.2 1319333.4529200005
6.1C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
17 6.1.14C Cement mortar 1:6 (1 cement: 6 coarse sand ) - 250 mm th Brick work Cum 340.65725 4923 1677055.64175
6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level.
18 6.45.1 Cement mortar 1 : 3 (1 cement : 3 coarse sand) Cum 4.971874999999999 723 3594.665624999999
0.0 Flooring Works
19 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I. Sqm 2314.4800000000005 283.3 655692.1840000001
8.13 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
20 8.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. Sqm 124.38 3605.2 448414.77599999995
11.41A Providing and laying Vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
11.41A.3 Glazed Vitrified tiles Matt/ Antiskid finish of size.
11.41A.1 Double charge vitrified tile polished finish of size
AT Ground Floor LVL
23 11.37A Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the anufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Sqm 128.054 663.8 85002.24519999999
0.9 Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel einforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).
0.9 Extra over item No. 23.3 for providing additional bulb in under reamed piles, under specified dia meter (Only the quantity of extra bulbs are to be paid).
26 10.2 Structural steel work riveted or bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved ateef primer all complete. Kg 3543.2000000000003 95.4 338021.28
27 10.18 Providingand fixing circular/hexagonal cast iron orM.Ssheet box for ceiling fan clamp140mm internal dia, 73mmheight, 5mm thick rim bottomandtoplids,1.5mmthickM.Ssheetwithitstopsurfacehackedforproperbondingtoplidshallbescrewedintothecastironboxbymeansof.3mmdiaroundheadedscrews,onelockathecorners.Clampsshallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing. Num 60 165.4 9924
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
28 9.48.1 Fixed to steel windows by welding. Kg 1045.4399999999998 144.5 151066.08
10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required.
29 10.32.2 In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works. Kg 6118.2 114.6 701145.72
0.0 Plaster & Finishing Works
13.11 12 mm cement plaster of mix
13.24 6 mm cement Plaster to ceiling of mix
31 13.24.2 1:4(1 cement;4 coares sand) Ground And first floor Sqm 772.2090000000001 125.6 96989.4504
32 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm 3216.3639999999996 105.4 339004.7656
13.46A Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade.
33 13.46A.1 New work (Two or more coats applied @ 1.43 ltr / 10 sqm. Over and including base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm). Sqm 1872.4125 132.5 248094.65625
13.48 FinishingwithDeluxeMulti surfacepaint systemfor interiors an exteriors using Primer as per manufacturers specifications.
34 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @0.75 ltr /10 sqm. Sqm 1343.9515 117.3 157645.51095
0.0 Stone Works
11.3 40 mm thick fine dressed stone flooring over 20 mm (average) thick base with joint finished fiush:base 1:5 (1 cement: 5 coarse sand )with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.
0.0 Roofing Work
36 12.48 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately Sqm 76.93 292.1 22471.253000000004
0.0 Wood work & Pvc work
0.000 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge
37 9.117.2 Extruded section profile size 42x50 mm Sqm 131.4 251.8 33086.520000000004
0.9 Providingwoodworkinframesofdoors,windows,clerestorywindowsand other frames,wrought framedand fixed inpositionwithholdfast lugsor with dash fasteners of required dia& length ( hold fast lugs or dash fastener shall be paid for separately).
0.0 Providingand fixing glazed shutters for doors, windows and clerestory windowsusing4mmthick float glasspanes including ISImarkedM.S. pressed butt hinges bright finished of required size with necessary screws.
9.9.1 Second class teak wood
40 9.118.2 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-incharge. Sqm 37.31999999999999 1846.9 68926.30799999999
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
41 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 2 33603.4 67206.8
0.0 Dismantling & Demolishing work
42 15.3 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead: Cum 18 1411.2 25401.600000000002
43 15.4 Demolishing R.B. work including stacking of steel bars and disposal of unserviceable material within 50 metres lead: Cum 12.599999999999998 1264.1 15927.659999999996
44 Add 5.36% GST on SOR item As Per BCD 1158296.2064990918
49 Add 5.36% GST on SOR item As Per BCD 233026.67405523392
SANITARY FIXTURES
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
50 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps nos 11 2764.4 30408.4
51 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. nos 11 1068.5 11753.5
17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
52 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid nos 3 4230 12690
17.1 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
53 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests nos 8 4470.9 35767.2
17.4 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
54 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern nos 3 3723.2 11169.599999999999
55 17.72 Providing and fixing white vitreous china flat back or wall corner type lipped roviding and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms nos 4 204.7 818.8
8.1 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and
56 8.10.1 White Agaria Marble Stone sqm 35 3061.2 107142
57 17.71 Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. nos 12 146.3 1755.6000000000001
0.00_ Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
17.60.1 100 mm inlet and 100 mm outlet
58 17.60.1.1 Sand cast iron S&S as per IS: 3989 nos 12 1129.2 13550.400000000001
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.35 Providing and fixing soil, waste and vent pipes :
61 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 Metre 95 978.3 92938.5
17.38 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
62 17.38.1.1 Sand cast iron S&S as per IS - 1729 each 15 530.7 7960.500000000001
17.39 Providing and fixing plain bend of required degree..
63 17.39.1.1 Sand cast iron S&S as per IS - 1729 each 15 457.2 6858
17.41 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :
64 17.41.1.1 Sand cast iron S&S as per IS - 1729 each 15 1038.8 15582
17.42 Providing and fixing double equal plain junction of required degree.
65 17.42.1.1 Sand cast iron S&S as per IS - 1729 each 15 861.2 12918
17.43 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
66 17.43.1.1 Sand cast iron S&S as per IS - 1729 each 15 671.2 10068
17.44 Providing and fixing single equal plain junction of required degree :
67 17.44.1.1 Sand cast iron S&S as per IS - 1729 each 15 580.2 8703
17.53 Providing and fixing sand cast iron S&S off sets as per IS-1729
17.53.1 76 mm off sets
17.53.1 114 mm off sets
69 17.53.2.2 With 100mm dia pipe Each 15 560.1 8401.5
17.53.3 152 mm off sets
70 17.53.3.2 With 100mm dia pipe Each 15 666.3 9994.5
17.55 Providing and fixing door piece, insertion rubber washer 3 mm thick, bolts & nuts complete.
71 17.55.1.1 Sand cast iron S&S as per IS-1729 Each 15 711.3 10669.5
17.56 Providing and fixing terminal guard:
72 17.56.1.1 Sand cast iron S&S as per IS-1729 Each 15 392.9 5893.5
17.57 Providing and fixing collar
73 17.57.1.1 Sand cast iron S&S as per IS-1729 Each 15 399.6 5994
17.58 Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter.
17.59 Providing and fixing M.S stays and clamps for sand cast iron / centrifugally cast (spun) iron pipes of diameter:
17.34 Providing and fixing toilet paper holder :
77 17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. nos 14 886.2 12406.800000000001
17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required :
78 17.9.1 White glazed fire clay kitchen sink of size 600x450x250 mm 2 2778 5556
EXTERNAL & INTERNAL WATER SUPPLY
18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
79 100 mm diameter nos 2 500.4 1000.8
18.58 Providing and fixing PTMT grating of approved quality and colour.
18.58.1 Circular type
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
81 18.8.1 15 mm nominal outer dia Pipes Metre 30 278.2 8346
82 18.8.2 20 mm nominal outer dia Pipes Metre 45 350.8 15786
83 18.8.3 25 mm nominal outer dia pipes Metre 25 463.1 11577.5
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
84 18.7.2 20 mm nominal outer dia Pipes Metre 45 233.9 10525.5
85 18.7.3 25 mm nominal outer dia Pipes Metre 55 317.3 17451.5
86 18.7.4 32 mm nominal outer dia Pipes Metre 35 395.2 13832
87 18.7.5 40 mm nominal outer dia Pipes Metre 35 538.4 18844
88 18.7.6 50 mm nominal outer dia Pipes Metre 220 791 174020
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
89 18.17.1A 20 mm nominal bore. nos 10 465.4 4654
90 18.17.1 25 mm nominal bore nos 10 532.3 5323
91 18.17.2 32 mm nominal bore nos 5 589.9 2949.5
93 18.17.4 50 mm nominal bore nos 8 878.2 7025.6
94 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per liter 4000 9.7 38800
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
95 18.18.1 15 mm nominal bore nos 50 348.9 17445
0.00_ Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts,nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
96 18.60.1 50 mm dia nominal bore each 3 3533.7 10601.099999999999
97 18.65 Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms. Each 12 96.8 1161.6
18.75 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
98 18.75.3 25mm nominal bore, weighing not less than 62 gms each 20 100.6 2012
99 18.77 Cutting holes up to 15 x 15 cm in R.C.C floors and roofs for passing drain pipe and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4(1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. Each 20 217.1 4342
18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
100 18.53.1 15 mm nominal bore nos 25 500.4 12510
101 18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : nos 20 434.2 8684
18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
102 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 100A No 12 1177.9 14134.800000000001
2.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:
2.10.1 All kinds of soil
103 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia Metre 510 391.7 199767
12.78 Providing and fixing on wall face PVC (working pressure 4kgf per sqm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
104 12.78.2 110 mm diameter Metre 70 257.5 18025
12.79 Providing and fixing on wall face PVC moulded fitting / accessories for rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
12.79.1 Coupler
12.79.2 Single pushfit Coupler:
12.79.3 Single tee with door
12.8 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S screws of required length, including cutting brick work and fixing in cement mortar 1:4( 1 cement: 4 coarse sand) and making good the wall etc. complete.
110 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 7 47.9 335.3
19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
19.4.1 100x100 mm size P type
112 19.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 3 1860.6 5581.799999999999
0.0 Providing, laying and jointing glazed stoneware pipes class 'SP1' with stiff mixture of cement mortar in the proportion of 1:1(1 cement: 1 fine sane) including testing of joints etc. complete.
113 19.1.2 150 mm diameter Metre 3 464.3 1392.9
0.0 Providing and laying cement concrete 1:5:10 ( 1 cement: 5 coase sand: 10 graded stone aggregate 40 mm nominal size) all-round S.W pipes including bed concrete as per standard design.
114 19.3.2 150 mm diameter S.W. pipe Metre 3 311.4 934.1999999999999
19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
116 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 7 7914.7 55402.9
117 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be isible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. each 40 310.9 12436
19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
118 19.19.3.1 Circular shape 560 mm internal diameter each 9 985.1 8865.9
19.27 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
119 19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 20 3743.3 74866
19.29 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame and vertical grating complete as per standard design :
120 19.29.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 7 7186 50302
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
121 19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 2 7090 14180
RAIN WATER HARVESTING & TUBEWELLS
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
24.1.1 All types of soil
0.0_ Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
123 24.3.3 200 mm nominal size dia mtr 150 940.8 141120
124 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. cum 10 1188.9 11889
125 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. cum 28 1195.6 33476.799999999996
126 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. cum 10 1195.6 11956
127 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. cum 10 1343.2 13432
24.1 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. (All types of soil)
24.2 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC (UPVC) medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
131 24.3.2 150 mm nominal size dia M 300 660.1 198030
132 24.3.1 100 mm nominal size dia M 300 546.1 163830
24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC (UPVC) medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
133 24.4.1 100 mm nominal size dia M 300 573.1 171930
24.13 Supplying the following fittings & fixing the same in position as per approved lowering assembly and strata chart including providing all equipments and welding the same on process of lowering the assay etc. all complete as per S/D of E/I.
24.14 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
135 24.14.2 (b) 150 mm dia M.S. Clamp 1.6 M long (one Pair) No. 2 1531.4 3062.8
24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
136 24.15.1 100mm dia & 6mm thick M.S. well shoe plug No. 2 228.3 456.6
137 Add 5.36% GST on SOR item As Per BCD 142346.11031466664
Wet Riser & Sprinkler System for Fire safety
4 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
(b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads
7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
139 7.6 80mm nominal dia Rmt 1 951 951
140 7.7 100mm nominal dia Rmt 50 1316 65800
9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
141 9.1 Single headed Gunmetal Set 3 7245 21735
11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
144 13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. each 1 1236 1236
14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
15 Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
147 0.0 Gunmetal Set 6 5206 31236
17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. "Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket."
18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
149 0.0 Gunmetal Set 3 2393 7179
19 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
150 0.0 2 way-100 mm dia M.S. Pipe Set 1 6331 6331
151 20 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. Set 1 17707 17707
152 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per liter 25000 9.7 242499.99999999997
SUB HEAD-I :-WIRING POINTS
1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch ,modular plate suitable size G.I box etc as per requred.
154 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. Metre 1400 309 432600
0.0_ Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
155 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre 1200 246 295200
1.21 Supplying & fixing of following size medium class PVC conduit along with accessories in surface/ recess including cutting of wall and making good the same in case of recessed conduit as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modulor plat & switch box/ including connections but excluding modular plate etc .as per required etc.
158 1.24.1 5/6 amps switch Each 25 82 2050
159 1.24.3 15/16 amps switch Each 50 139 6950
160 1.24.4 3 pin , 5/6 amps socket outlet Each 25 112 2800
161 1.24.5 6 pin , 15/16 amps socket outlet Each 50 183 9150
162 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required. Each 35 358 12530
163 1.26 Supplying and fixing modular blanking plate on the existing modular plate & metal box excluding modular plate, etc. as required. Each 30 34 1020
1.27 Supplying and fixing following size/ modules, Gl box along with modular base and cover plate for modular switches in recess etc as required.
164 1.27.1 1 or 2 Module (75mm X 75mm) Each 10 234 2340
168 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. Each 15 64 960
169 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. Each 20 80 1600
1.59 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc as required.
SUB HEAD-2 :-SWITCHEARS & DB'S
2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required'
2.7 Providing and fixing following capacity four pole ON-load panel mounted changeover switches inside the existingcubical panel board including drilling holes in cubicle panel, making connections etc. as required.
2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator)
173 2.9.3 8 way ( 4 + 24 ), Double door, horizontal type Each 2 6199 12398
2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required'
174 2.12.1 6 A to 32'A, Single pole Each 58 237 13746
2.13 Supplying and fixing following rating, 2401475 volts, "C"curve, miniattlre circuit breaker suitable for lnductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
175 2.13.1 6 A to 32 A, double pole Each 1 667 667
176 2.13.3 40 A to 63 A, double pole Each 7 1198 8386
177 2.13.4 40 A to 63 A, four pole Each 2 2324 4648
178 2.19 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Each 10 1513 15130
SUB HEAD-3 :-EARTHING
179 3.2 Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. set 5 6323 31615
180 3.4 Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. set 1 6884 6884
181 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. set 1 13721 13721
182 3.7 Supplying and laying 6 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with Gl thimble as required. Meter 500 37 18500
183 3.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of brass nut bolt and & spring washer spaced at 50mm) Meter 40 1026 41040
184 3.9 Supplying and laying 25 mm X 6 mm G.t. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.l. nut bolt & spring washer spaced at 50 mm) Meter 150 133 19950
SUB HEAD-IV :-LIGHTNING CONDUCTOR
185 4.1 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having singte prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. set 1 1056 1056
186 4.4 Jointing copper/ G.l. tape (with another copper/ G ltape,base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. set 1 81 81
187 4.6 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) M 30 559 16770
SUB HEAD-5 :-LED LUMINAIRES
5.7 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
190 5.9 Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required. Each 60 2663 159780
191 5.13 Supplying and fixing post top / gate light (width 250/300mm) made up of high grade unbreakable polycarbonate material suitable for upto 20 watt LED lamp including connections and earthing the body etc as required. ( Butwithout lamp) Each 50 1399 69950
5.15 Supplying and fixing fotrlowing types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on poleibuilding including connection earthing the body etc as required
6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
193 6.7.7 20 watt LED lamp Each 50 267 13350
SUB HEAD-6 :- MISCELLANEOUS & MV/HT CABLE LAYING
0.0_ Laying of one number additional PVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
195 7.2.2 Above 35 sq. mm and upto 95 sq. mm Metre 200 232 46400
0.0_ Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
SUB HEAD-7 :- LIGHTING POLE, FAN & PANEL
199 8.9 Supply and fixing pole mounted junction box/fuse box for single phase/ 2 core low wattage street light pole with all accessories and connection etc. as required. Each 10 825 8250
200 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 35 2482 86870
8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
SUB HEAD-8 :- CIVIL ITEMS
9.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part ll complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. ln the existing trench, complete as required.
202 9.15.5 200 mm dia (OD-200 mm & lD-175 mm nominal) metre 300 646 193800
9.16 Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
203 9. 16.1 For 4 metre pole (500mm X 500mm X 1000mm) Each 50 3505 175250
204 9.16.2 For 6/7 metre pole (500mm X 500mm X 1400mm) Each 10 4398 43980
BILL OF QUANTITY FOR NON SOR ITEMS
Development of Satimata Sthan, Dhruvgama, Kalyanpur, Samastipur, Bihar.
Bill of Quantity
(Each Item rate must be filled)
Sl. No Sl. No./ Code. SOR- Description of Work Unit. Qnty Amount(Rs)
1 NS-7/Rate analysis NS-5 Supply Installation, commissioning and testing of single phase 2H.P. submersible pump set having discharging capacity 3 Ips at a total head of 30 meter(approx) of KSBj Kirloskaror equivalent make with all accessories& fittings etc including loading unloading and transportation of the pump set to the work site with all required labour, materials, tools and tackles installation, testing & (i) 50 mm dia x 3 mtrs long medium classG.I column pipe both end thread and one end socketed- 6(six)nos (ii) lx3x2,5 mm' flat copper conductor submersible cable -40 (forty) mtrs. (iii) 50 mm dia union socketlIonel no. (iv) 65 mm dia x 250 mm long G.!. nipple- 1(one) no. (v) 50 mm dia G.I Elbow-l(One) no. (vi) 50 mm dia M.S, clamps-2(Two) Pairs. (vii) 50 mmx 250 mm long G.I nipple- lIOnel no. (viii) Tube well cap for T/WelllIonel no. (ix) 50 ":l~ia x 65 mm dia Each 2
Supply Installation, commissioning and testing of floor mounted outdoor type loT feeder pillar single phasestarter controll pannel operated on 220V, 3 phase, 50 cis for 3 HP Submersiblepump set made of MSsheet (minimum 2 mm thick) duly spray power coated painting with following accessoriesmade of M.Ssheet ( minimum 2mm thick) duly spray powder coated painting with following accessories (i) 90-220 V range single phase7. 5 KVA automatic voltage stabilizer make- Sen& Pandit/ Vertex/lSI marked If any. 1No. (ii) Suitablesinglephasestarter control panelfor abovemotor of BCH /L& Tmake-1(one) no. 2
Supplying& fitting 2.5 mm' copper service cable from power point from nearest source up-toIpumping station .. 150
Providing all materials and labour required lor doing earthing station with G.I earth pipe of 40 mm dia x 4.5 mtrs 20fts. long G.I pipe including accessories excavation of earth , providing masonry enclosure with Coverplate having locking arrangementand watering pipe etc.with salt, charcoal,etc.as per IE & IS specification 2
2 NS-1 Providing Supply of Grape Supporting Bars, 12 mm diameter, 2.4 m long, fabricated from mild steel with U-bend at ends for wire holding, surface painted (2 coats red oxide + 1 coat enamel), suitable for trellis grape farming system. Nos 4
3 NS-2 PROVIDING FIXING TESTING COMMISSIONING Delta Brass Robe Hook | Coat Hook | Bathroom Accessories (Chrome Finish, Wall Mounted) testing of joints complete as per direction of Engineer in Charge. Nos 14
4 NS-3 Providing Supply and place PARASNATH brand stainless steel perforated dustbin, capacity 10–15 liters, made from high-grade SS 202/304 stainless steel with a matt finish. Dustbin shall have a perforated body design for ventilation, be corrosion-resistant, durable, and suitable for indoor use in offices, institutions, or commercial spaces. Approximate dimensions: 250mm diameter x 300mm height. Smooth edges and anti-skid base. Sample to be approved prior to supply. Nos 11
5 NS-4 Providing & fixing of approved coloured verticle type hot water 25 ltr geysers. The inner container shall be made of copper sleeve with PUF insulation between inner and outer container, element pipe and heating element, pressure cum vaccume release, thermostat and thermal cutout arrangements and fusible plug. The outer container shall be of powder coated finish with all other accessories including fixing brackets complete as required. Nos 2
6 NS-5 Supplying and fixing of shower diverter made of brass/chrome-plated, suitable for concealed installation, 2-way/3-way function, including necessary fittings, cutting, threading, and making connections complete in all respects as per direction of Engineer-in-Charge. Nos 2
7 NS-1 Transportation of drilling plants, developing equipments & all other required tools and M/c by and suitable mechanical means including all cost of loading, unloading, placing at work site and back after completion of work as per S/D of E/I Each 4
8 NS-2 Supplying all materials and labours for arrangement for additional water required during the drilling period for 70 Hrs & site clearance & leveling etc. And providing the soap duster etc. to staff engaged in drilling etc. all complete work as per specification & direction of E.I. Each 5
FIRE EXTINGUISHERS
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.
9 NS-4 ABC powder type fire extinguisher of 6 Kgs. Capacity, with initial filling (Mono Ammonium Phospate Powder) in brand new cylinder with powder coated finish, Stored Pressur type, Pressure Gauge, Controllable discharge mechanism with Hose & Nozzle , confirming to IS:15683:2008. Nos. 3
10 NS-5 Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, Co2 gas as per IS 15222 with controll discharge mechanism fitted with Hose & Horn applicable on Class B fire rating 21B confirming to IS: 15683:2008. CO2 Cylinder as per IS 7285 with ISI mark. Nos. 3
SUB HEAD-11 :- NS ITEMS LIGHTING
11 NS-1 SITC of Step light with 3W,h aving IP65 ProtectionRating, CCT: 3000K / 5600K, Aluminum Alloy Material, Body Color: Telegrey. Input Voltage: AC100-230V Each 30
12 NS-2 SITC of 9W Mono color Spike light, Protection Rating : IP66, complying to BIS standard "IS 10322 (Part 5/Sec 1): 2012" and having CE certification against standard "Low Voltage Directive & Protective Equipment - EN 60598-1:2015", and "Electromagnetic Compatibility Directive - EN 61547: 2009", Mounting Structure : Spike for fixing the lights. Power consumption : 9W, CCT : 1800/3000/4000/6000K, (as per the design approval) Optics : PMMA with holder, Beam Angle : 15º/25º/45º/60º, Control : ON/OFF, Body : Die casted / extruded aluminium with embossed manufacturer logo, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : AC110-230V, Surge Protection : Inbuilt surge protection 2KV- 4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK05, IP66, from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Each 19
13 NS-3 SITC of 9W Mono color Spot light, Protection Rating : IP66, complying to BIS standard "IS 10322 (Part 5/Sec 1): 2012" and having CE certification against standard "Low Voltage Directive & Protective Equipment - EN 60598-1:2015", and "Electromagnetic Compatibility Directive - EN 61547: 2009", Mounting Structure : Adjustable wall mount yoke arrangements for fixing the lights. Power consumption : 9W, CCT : 1800/3000/4000/6000K, (as per the design approval) Optics : PMMA with holder, Beam Angle : 15º/25º/45º/60º, Control : ON/OFF, Body : Die casted / extruded aluminium with embossed manufacturer logo, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications. Power Input : AC110-230V, Surge Protection : Inbuilt surge protection 2KV-4KV(Additional if required will be added as per the requirement), Toughened transparent glass having the IK protection up to IK05, Painting : Chemical 3/7 tank processed treatment before the powder coat black/ash/approved color coat. Fixture will be suitable to operate in a temperature range of 0°C to 50°C, LED life should be at least 50,000 burning hours at L70 at 25 degree centigrade. Luminaire is inclusive of Integral male/female waterproof connectors with structures in pre wired conditions as per IS standard. PCB thickness must be 1.6mm, 35 micron Copper, 2W TC with Black or White masking, Copper /OSP finish. LM79, IK05, IP66, from NABL Acrediated laboratory. LED Makes should be CREE, LumilLED, Osram, Seoul, Nichia or equivalent with the engineer or 3rd party testing laboratory approval. Each 5
NS-4 Feeder Pillar
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of Distribution Panels fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) GI sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry,300 mm MS painted stand and standing covering from 3 sides, IP 55 double door with canopy ,dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided at the bottom of the panels with appropriate stand etc. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels.(Make AAA Switchgear, Indiatech panel, Neptune india)
Feeder Pillar (For External Landscape lighting) IP 55 for outdoor Protection
63 Amps 4 pole MCCB
100 Amps TPN Aluminium bus bars with heat shrinkable insulation sleeve. - 1 Set
63 Amps two pole MCB incomer with 63 Amps DP contactor 0-24 hours timer auto / manual and outgoings including 10 No. 10/16/20 Amps SP MCB with separate neutral link of each phase- 1 set (50%)
40 Amps DP MCB with 32 amp industrial sockets - 2 sets
63 Amps 4 Pole MCB - 5 set
14 Feeder Pillar for external / landscape lighting as described above Each 1
NS-5 Solor PV Module
Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. (with a 5-year product warranty)
15 Above 1 kWp and up to 10 Kwp Each 10
NS-6 Solar Street Light (Make ielecssol)
Supply Installation testing commissioning of All-in-one Solar Street Light (Luminaire) Model Polaris Product Specification:- 30W LED, 120W-Mono Panel, 12.8v 54Ah Battery, 6 MTR GI tubular pole od-76 mm thickness 3mm with complete accessories. Warranty: a) Solar PV Modules : Solar PV Modules will be warranted up to 90% power output for 10 years and 80% power output for 25 years from the date of installation. b) LED Light : 3 years Warranty c) Lithium Battery: Battery will be warranted for 5 years.
16 Above 1 kWp and up to 10 Kwp Each 30
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT03madhubani.pdf
NIT • 0.38 MB
03666_92885_RCD141dt28102021.jpeg
NIT • 0.20 MB
SBD DocumentNIT03Satimata Sthan, Kalyanpur,Dhruvagama- GR03.pdf
NIT • 1.07 MB
NIT03madhubani.pdf
NIT • 0.38 MB
Technical bid -NIT03Satimata Sthan, Kalyanpur,Dhruvagama- GR03.xls
NIT • 0.05 MB
Financial and BOQ SheetNIT03Satimata Sthan, Kalyanpur,Dhruvagama- GR03.xls
NIT • 4.11 MB
Corrigendum1NIT03madhubani_samastipur.pdf
NIT • 0.33 MB
Financial and BOQ SheetNIT03Satimata Sthan, Kalyanpur,Dhruvagama- GR03.xls
NIT • 4.11 MB
Download all tender documents and submit your bid