Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹24.9 L+₹90,310 (3.77%)Rejected-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹28.6 L+₹4.7 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹28.8 L+₹4.8 L (20.0%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹29.6 L+₹5.6 L (23.3%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
29 Oct 2021, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF DI CI PIPE SLUICE VALVE NRV AND ALLIED WORKS AT NOFRA WNC O MESS ROBERT ROAD UNDER GE NW NAVY NAGAR COLABA MUMBAI
2021_MES_477717_1
8165/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and Category a(ii)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹78,000
Yes
17 Nov 2021
25 Sept 2021
30 Oct 2021
25 Sept 2021
29 Oct 2021
9 Oct 2021
25 Sept 2021 - 15 Oct 2021
Amount
S&F in repair in Sluice valves flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 1.6, conforming to IS 14846 of 2000 for following sizes in any position/location including all flange joint with rubber or fiber board gaskets, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed of following sizes :- Note :- For Additional manpower, welding, chipping, plastering and any other item required for replacement of the item including making good the disturbed surfaces are deemed to be including in the item rate and no extra payment will be claimed by the contractor to the work.
(a) 300 mm bore
(b) 250mm bore
(c) 200 mm bore
(d) 150 mm bore
(e) 100 mm bore
Supply and fixing in repair CI swing type non return valve flanged end of following sizes as per IS: 5312 body, cover C-I IS: 210, PN-16 complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed.
(a) 300 mm bore
(b) 250mm bore
(c) 200 mm bore
(d) 150 mm bore
(e) 100 mm bore
Supply and fix in repairs CI foot valve flanged end IS 4038 PN 0.6 housing complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed.
(a) 150 mm bore
(b) 100 mm bore
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified.
Note : For item No 04 and 05 above rate deemed to be included for earth work and form work required as per site requirement & as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced)/bituminous road in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and debris out side MD land all as specified.
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement all as specified.
Removing excavated material exc 250 M but n.exc 500 M and depositing where directed all as specified.
M & L for CI specials conforming to IS - 1538, spigot /socket or flanges fitting I.e. bend, tee, collar, flanges/ socket /spigot, Tappers and tails pieces etc suitable for 100/150/200/250/300 mm bore pipes (joints and joining material shall be measured and paid seperately)
M & L for DI specials conforming to IS - 9523, spigot /socket or flanges fitting I.e. bend, tee, collar, flanges/ socket /spigot, Tappers and tails pieces etc suitable for 100/150/200/250/300 mm bore pipes (joints and joining material shall be measured and paid seperately)
M & L for run lead joint in repair with pig lead including pumping out / bail out water, to repair the joints for following sizes of pipes :-
(a) 300 mm bore
(b) 250 mm bore
(c) 200 mm bore
(d) 150 mm bore
(e) 100 mm bore
M & L for Cutting existing cast iron pipes and reducing for insertion of CI fittings to required length in position for following sizes :- Note :- Pipe fittings used shall be measured and paid under relevant items of schedule 'A' remaining items like welding and other items required shall be deemed to be included in the item rate
(a) 300 mm bore
(b) 250 mm bore
(c) 200 mm bore
(d) 150 mm bore
(e) 100 mm bore
Construction of brick masonery valve chamber in repair of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified.
Supply and laying in replacement of spigot and sfocket ductile iron water tubing having cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329:2000, including rubber joint of suitable size, class K-9 laid on wall/roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed.
(a) 300mm bore
(b) 250 mm bore
(c) 200mm bore
(d) 150mm bore
(e) 100mm bore
(f) 80mm bore
Supply/Fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary fixing with clamps on wall & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length.
(a) 25 mm bore
(b) 40 mm bore
(c) 50 mm bore
(d) 80 mm bore
Supply and fixing in repairs MS pipe heavy grade 'C' class and dimensions confirming to IS: 1239 (Part-1) - 2004, equivalent to BS- 1387/1985 for suction and deliver for pump including painting of one coat red oxide primer and two coats of synthetic enamel paint after fixing, welding and providing necessary PCC support as required at site complete all as specfied and directed by Engineer-in-charge of following sizes :-
(a) 150 mm dia
(b) 100mm dia
( c) 80mm dia
Attending the water supply breakdowns of any size/type of pipes in any position/location/depth including necessary excavation, earth work, cutting of pipes, welding, replacement of pipes of any nature, flanges, bends, collars, nut bolts, gasket, run lead joint or any other items required for rectification of break downs, testing and making good to the disturbed surfaces after rectification complete all as specified and directed for the following size of pipe lines :- Note :- 1. Items like run lead joint, CI/DI /MS fittings or pipes shall be measured and paid separately under relevant item of schedule 'A 2. Remaining items are shall be deemed to be included in the item rate and extra payment shall not to be claimed for the completion of break down. 3. After hand over of complaint, contractor shall complete the break down within 24 hrs or other wise panel recovery shall be made 2500/- per breakdown
(a) 300/250 mm dia CI/DI/MS pipe line
(b) 150 mm dia CI/DI/MS pipe line
(c) 50/80 mm dia CI/DI/MS/GI pipe line
S&F in repairs PVC water storage Tank with cover triple layer pure anti microbail round type and dismantling of existing foundation and making new PCC foundation size 10 cm more than the dia of the tank and height of the foundation not less than 20 cm height and making connections including replacement of new GI fittings i.e. tank nipple, washers, float valves and Gate valves and Pipes for connecting the existing delivery lines and testing complete all as specified and directed for the following capacity :- Note :- Gate valves and GI pipe only shall be paid under relevant item of Schedule 'A' remaining items shall be deemed to be included in the item rate.
(a) 5000 Ltr capacity
(b) 3000 Ltr capacity
(c) 2000 Ltr capacity
(d) 1000 Ltr Capacity
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-
(a) 40 mm bore
(b) 50 mm bore
(c) 80 mm bore
(d) 25 mm bore
Unity Enterprises
N.S.ENTERPRISES
Shetty Construction Co
vikas construction
bajaranga enterprises
SHRI SAI ENTERPRISES
BA Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .