| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹35.9 L+₹3.6 L (11.1%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹38.8 L+₹6.5 L (20.0%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹39.2 L+₹6.9 L (21.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹49.9 L
EMD Value
₹1 L
Closing Date
25 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura
As per Tender Documents
2022_MES_525977_1
CWE/MTR/E OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (East) Mathura
As per NIT
7 documents required · 7 mandatory
₹500
GE (East) Mathura
₹1 L
Yes
18 Jul 2022
24 May 2022
4 Jul 2022
24 May 2022
25 Jun 2022
11 Jun 2022
60 days
Amount
M&L for repairing / servicing of gang operating devices 11000 volts up to 400 Amps including cleaning, greasing all the moving parts and applying petroleum jelly at the contact points including dismantling and replacing all the unserviceable parts / spares complete all as specified and directed. Note :- (i) The rate quoted against this item shall be deemed to include cost of petroleum jelly, renewal of worn out nuts, bolts & washers, binding wire and PG clamps etc complete as required for proper functioning of GOD switch. (ii) Cost of item required to be repalced for making GOD switch serviceable will be measured and paid under supply only under item No 2 here in after.
Supply only following items required for GOD switch under item No 01 :-
Moving contact blades copper alloy (Male contact).
Fixed contact jaw copper alloy (Female contact).
Dismantling unserviceable cross arms, clamps etc and removing from site complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps, hooks and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed.
Excavation in trenches for laying under ground cable, erection of poles and stays in soft / loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed.
All as per item Srl No 5 here-in-above but in PCC / floor / road
Excavation in trenches for laying under ground cable, erection of poles and stays in soft / loose soil not exceeding 1.5 meter wide and exceeding 1.5m but n.exc 3.00m deep and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed.
Sand cushioning with locally available river sand to under ground cable in trenches/existing cable trenches / ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover class HV type 1 with peak size 300 mm x 180 mm x 40 mm complete all as specified and directed.
Supply and fixing in replacement Lead acid battery 12volt 150AH complete all as specified and directed.
M&L for identification of fault location of underground HT cable of any size or type with help of cable fault locator machine at site including removal of moisture content from the cable complete all as specified and directed. Note :- The rate for arrangement of the machine for fault location is deemed to be inclusive in quoted retes. However, necessary excavation, earthwork, jointing materials will be measured and paid separately under relevant items of schedule.
M&L for taking out HT underground cable of any size or type from excavated trenches, repairing the same as required at site and relaying the cable after repair at same or another location as directed at site. Note :- Necessary excavation, earthwork, jointing materials will be measured and paid separately under relevant items of schedule.
Disconnecting & taking out 11KV HT VCB/RMU of any description and any make of rating 400 / 630Amp and dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts if required of make as approved by GE complete all as specified and directed :- Notes :- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts. (ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after (iii) Servicing to be carried out by service engineer of OEM.
Supply only Vaccum bottle suitable for 630 Amp, 11KV HT VCB
Supply only Vaccum bottle suitable for 400 Amp, 11KV HT VCB
Supply only Fixed arcing contact assembly suitable for 630 Amp 11KV HT VCB
Supply only Moving arcing contact assembly suitable for 630 Amp 11KV HT VCB
Supply only Fixed arcing contact assembly suitable for 400 Amp 11KV HT VCB
Supply only Moving arcing contact assembly suitable for 400 Amp 11KV HT VCB
Supply only Shunt trip coil 24-30 Volts DC suitable for 11KV VCB
Supply only Spring charging motor 110-230 Volts AC 50 Hz suitable for 11KV VCB.
Supply only PVC spout assembly suitable for 11KV VCB/ Bus coupler
M&L for checking tripping of 33/11KV circuit breakers through programming microprocessor based numerical relay / IDMT over current and earth fault relays at plug setting intended in service by primary current injection in CT to ensure proper function of relays trip coil control circuit etc during fault condition complete all as specified and directed.
M&L for testing of over current & earth fault of programming microprocessor based numerical relay / IDMT relays as per time / current characteristics by secondary injection test O/C 50%, 75%, 100%, 200% & E/F 20-80% plug setting and operating time at twice the set valve & TMS 1 including well cleaning and de-carbonizing of relay contacts complete all as specified and directed.
Disconnecting & taking out 33KV HT VCB of any description and any make of rating 400 / 630Amp and dismantling / opening of the VCB for preventive maintenance / servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and renewal of unserviceable parts with new one, re-assembling the VCB after overhauling / servicing and its testing complete and renewal of following unserviceable spare parts of make as approved by GE complete all as specified and directed :- Notes :- (i) The quoted rate of contractor includes for fixing the serviceable parts in position and renewal of unserviceable parts with new parts. (ii) The new parts shall be measured and paid separately under appropriate item as supply only mentioned here-in-after (iii) Servicing to be carried out by service engineer of OEM.
Supply only shunt trip coil 24-30 Volts DC suitable for 33 KV VCB
Supply only switch TNC (trip, neutral, close)
Dismantling insulators any type/ size from HT network complete all as specified and directed.
S&F pin type insulator suitable for 11 KV, porcelain vitreous white, brown or green of size 150 mm height and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and directed.
S&F post top insulator of 11 KV grade suitable for air break switch/ drop out fuse assembly with necessary nuts, bolts, washers complete all as specified and directed.
S&F in replacement lightning arrestor expulsion type complete with all fittings, transmission class discharge capacity 65 KA, 11000 volts including taking down existing unserviceable one complete all as specified and directed.
M&L for repair/ Maint/ servicing of 33KV/ 400Amp GOD AB switch to make it properly functional by oiling/ greasing of mechanical operating mechanism and renewal of old rusted nuts/ bolts/ MS clamps/ handle and provide petroleum jelly between fixed and moving contacts including dismantling and replacing all the unserviceable part / spares complete all as specified and directed. Note :- (i) The rate quoted against this item shall be deemed to include cost of petroleum jelly, renewal of worn out nuts, bolts & washers, binding wire and PG clamps etc complete as required for proper functioning of GOD switch. (ii) Cost of item required to be repalced for making GOD switch serviceable will be measured and paid under supply only under item No 24 here in after.
Supply only following items required for GOD switch under item No 23 :-
Supply only female contact / fixed contact Jaw suitable for 33KV GOD AB switch of rating 400 Amp complete.
Supply only male contact/ moving contact blade suitable for 33KV GOD AB switch of rating 400 Amp complete.
Supply only tinned copper flexible jumper suitable for 33KV GOD AB switch of rating 400 Amp complete.
Supply only MS jumper carrier suitable for 33KV GOD AB switch of rating 400 Amp complete.
Supply only back connector plate suitable for 33KV GOD AB switch of rating 400 Amp complete.
Supply only PG clamps plate suitable for 33KV bus bar over head conductor complete.
M&L for insulating mat for electrical installations, ISI marked of IS:15652 and of size 2 mtr x 1 mtr x 20 mm suitable for 11 KV system complete all as specified and directed.
M&L for HT cable route indicators made out of PCC 1:2:4 type B1 duly rendered with plaster 10 mm thick of size 40cm x 60cm x 20cm fixed & erected on PCC platform of size 40cm x 40cm x 10cm grouted in ground, finish surfaces with rendering in CM (1:4) duly painted on both sides marked with "HT cable Route" complete all as specified and directed.
Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, outdoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, Indoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Supply and jointing HT cable with jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Supplying, laying, testing and commissioning in repair, XLPE insulated, screened, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor ISI marked 11 KV grade (Earthed system) laid in trenches / on pole / in ducts or through sleeves of size 95 Sqmm 3 core complete all as specified and directed.
All as per item 30 here in above but cross sectional area 120 Sqmm 3 core complete all as directed.
All as per item 30 here in above but cross sectional area 150 Sqmm 3 core complete all as directed.
All as per item 30 here in above but cross sectional area 185 Sqmm 3 core complete all as directed.
Dismantling steel tubular poles/ struts of any size complete all as specified and directed.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-55 (11 metre long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and directed. Note : Earth work and PCC shall be measured and paid separately.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping complete all as specified and directed.
M&L for Glow Schematic diagram on flex sheet (size approx 150cmx75cm) made up of retroreflective material (blue colour) of schematic diagram and writing the letters/diagram on sign board in white complete all as specified and directed.
M&L for painting of steel tubular HT pole 11 mtr including cross arms, clamps, back plates etc in situ with one under coat and one finishing coat of aluminum paint after cleaning/ preparation of surfaces including making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking pole No on pole complete all as specified and directed.
All as per item No 40 here in above but for 2 pole structure including bracings.
All as per item No 40 here in above but for 4 pole structure including bracings.
Supply and fixing in replacement first aid box containing all first aid medicine/ointment/bandage etc as per standard practice complete all as specified and directed.
Supply and fixing precautionary/educational Rollup Chart (Electric shock treatment/First aid chart etc) of approx size 95x65cm printed on PVC sheet/photographic paper pipe mounted , thread for wall hanging, waterproof all as specified and directed.
Dismantling air break gang operated switch vertical / horizontal mounted including insulators and operating mechanism and removing the same from site complete all as specified and directed.
M&L for fixing air break gang operated switch outdoor type HT 11 KV triple pole mechanically operated mounted on HT insulators horizontal/ vertical type as existing at site including MS galvanised steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia GI pipe medium grade for current rating of cap 200 Amps 11000 volts with locking arrangement, MS clamps, bolts, nuts and washers etc including two coats of aluminum paint over a coat of red oxide primer on MS work complete all as specified and directed.
S&F in replacement drop out fuse assembly single pole 11 KV, 25 Amps rating complete with expulsion fuse element mounted on four / two pole structures including necessary nuts, bolts and washers complete all as specified and directed.
S&F Danger Sign Board In Red Colour (Electric ) surface sticker type approx size 15x22cm complete all as specified and directed.
S&F in replacement galvanised steel tube, light grade laid along the pole / in trenches / under road or floor of size 80 mm bore including removing the rusted old one complete all as specified and directed.
S&F in replacement galvanised steel tube, light grade laid along the pole / in trenches / under road or floor of size 100 mm bore including removing the rusted old one complete all as specified and directed.
Vijay Electricals
Ms Kamal Kant Agarwal
M/S S S CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .