Superintending Engineer EUDC-III GHAZIABAD
SE EUDC-III GANDHI NAGAR GZB
work of Fortification of 33/11 kv Substation and Supply and Installation of RMUs Under Business Plan Scheme 2024-25 (Part-2) in the area of EUDD-X, Ghaziabad. Under the jurisdiction of SE, EUDC-III, Ghaziabad.
2024_PVVNL_971433_1
13/W/2024-25/EUDC-III/GZB
Open Tender
Electrical Works
Item Rate
90 days
SE EUDC-III GANDHI NAGAR GZB
Please Refer Tender Documents
2 documents required · 2 mandatory
₹1,180
Superintending Engineer EUDC-III GZB
₹9,963
12 Dec 2024
7 Nov 2024
11 Dec 2024
7 Nov 2024
11 Dec 2024
7 Nov 2024
Amount
Carriage of ACSR Dog Conductor from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 kv XLPE Cable 3x185 sqmm from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 Mtr ST Pole from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Carriage of other line material as:- MS Angle Size 65x65x6 MM- 60 Kg, 11 kv V Type Cross Arm- 16 Nos, 11 kv Polymeric Disc Insulator- 24 Nos, 11 kv Polymeric Disc Insulator Fitting- 24 Nos, 11 kv Polymeric Pin Insulator- 64 Nos, 11 kv XLPE Cable 3x185 sqmm J/Kit- 8 Nos from Store center to work site loading and unloading both side. distance 1 km to 50 km.
Dismantling of old & Damaged ACSR Dog Conductor and Safley carriage from work site to Store center/JE store loading and unloading both side.
Erection of ST pole 11 Mtr long at site complete in all respect as per RESPO norms.
Providing Concreating of ST Pole complete in all respect as per RESPO norms.
Laying, Lifting and sagging of ACSR Dog conductor at various site complete in all respect as per RESPO norms.
Laying of 11 kv XLPE 3x185 sqmm cable at site complete in all respect as per RESPO norms.
Fixing of MS Angle Size 65x65x6 MM at site complete in all respect as per RESPO norms.
Fixing of 11 kv V Type Cross Arm at site complete in all respect as per RESPO norms.
Fixing of 11 kv Polymeric Disc Insulator at site complete in all respect as per RESPO norms.
Fixing of 11 kv Polymeric Disc Insulator Fitting at site complete in all respect as per RESPO norms.
Fixing of 11 kv Polymeric Pin Insulator at site complete in all respect as per RESPO norms.
Fixing of 11 kv XLPE Cable 3x185 sqmm J/Kit at site complete in all respect as per RESPO norms.
Supply & fixing of 12kv 630 Amps 21KA for 3 Sec. SF6 , BIL 28 KV/75 KV peak, extensible, outdoor duty 3-way, fully motorised and manually operated Ring Mains Unit originally manufactured by OEM in its factory only, comprising of 02 load break switch and 01 vaccum circuit breaker consisting of copper busbar in SF6 insulated tank with a provision electromechanical interlock to avoid accidental closure of earthing switch even when cable is in live condition. RMU should be Type Tested for Internal arc of 21 KA for 1 Sec with AFLR classification and gas to be from rear bottom of the switchgear away from the operator to ensure safety of the operating personnel. Suitable Ct 200-50/1 A with microprocessor based numerical over current relay (IDMTL + Inst.) for Protection to be provided with VCB Feeder with right angle boot for termination Kits. All the necessary wirings and Dummy panel/space for FRTU to be given along with RMU for future compatibility with SCADA system (Supply of FRTU is not in scope). Battery, Charger etc. for Motorised Operation of RMU to be provided. The scope is including Plinth/ Angle iron Stand as per OEM design complete in all respect as per the direction of Engineer incharge. Complete RMU and its accessories should be suitable for altitude of 100 mtrs above Sea Level. (Makes: ABB/Siemens/Eaton/Schneider or authorized by UPPCL). complete in all respect.
Providing of earth electrode for chemical earthing Pipe in pipe type proper hot dip Galvanization dia 50 mm length 3 mtr – 32mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & Pipe is filled with conductive Mixture – for hermetically Filling inside the cavity i.e. between secondary conductor & Primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc. The electrode should be sealed from both the ends. The outer pipe of the electrode should be galvanized the characteristics of this compound is highly conductive, nonmagnetic & noncorrosive in G.I. Including providing of backfill compound. Each electrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for RMUs installed.
Providing and fabricating the Fencing of RMU at site complete in all respect as per respo norms.
Providing & fixing of Dead and Clamp with Eye hook at site complete in all respect as per RESPO norms.
Providing & fixing of GI Turn Buckle at site complete in all respect as per RESPO norms.
Providing & fixing of GI Wire 6 SWG and 10 SWG for Garding at site complete in all respect as per RESPO norms.
Providing & fixing of 11 kv Holding Clamp at site complete in all respect as per RESPO norms.
Providing & fixing of GI Pipe 6" Dia at site complete in all respect as per RESPO norms.
Making of all HT/LT connections required to energize the line and restoring of electricity supply to consumer properly complete in all respect.
Divy Electrical Engineering (BID ID -4778888)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .