Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.5 L+₹4.6 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹51.7 L+₹7.8 L (17.8%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
20 Dec 2021, 6:00 pmClosed
GE (MIS) MHOW
Garrison Engineer (Maint) Inf school Mhow
REPAIR MAINT OF VARIOUS TYPES OF VALVES AND CONNECTED ITEMS REPAIR MAINT OF PUMPSETS FILTRATION PLANT CLEANING AND OPERATION OF SWIMMING POOL AND MAINTENANCE OF FIRE FIGHTING SYSTEMS UNDER GE MIS MHOW
2021_MES_489771_1
8440/GE (MIS)/MHOW
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (MIS) MHOW
As per tender documents
8 documents required · 8 mandatory
₹500
GE (MIS) MHOW
₹96,000
Yes
20 Jan 2022
22 Nov 2021
22 Dec 2021
23 Nov 2021
20 Dec 2021
6 Dec 2021
Amount
REPAIRS/MAINT OF VARIOUS TYPES OF VALVE AND CONNECTED ITEMS:
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in any type of soil for foundation, laying pipe or for shafts, wells, cesspits, manholes, pier holes, etc. complete all as specified and directed.
Returning filling in soft/loose soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated material (Soils) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
S&F cast iron fittings connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth of following size
Upto 150 mm bore
200 mm to 300 mm bore
Taking up cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead for descaling of following size all as directed and specified.
400 mm bore
300 mm bore
Relaying only cast iron pipe spigot and socket end of any class of 400 mm bore.Note:Pipe taking up vide Sl.item No 5 shall be laid under this item.
Relaying only cast iron pipe spigot and socket end of any class of 300 mm bore.Note:Pipe taking up vide Sl.item No 5 shall be laid under this item.
S&F in repair Sluice valves cast iron body, double flanged, ISI marked (IS-14846), heavy duty, class PN 1.6 gun metal with non rising spindle of solid forged bronze and operating handle, including rubber gaskets, nuts, bolts, washers etc all as specified and as directed by Engr-in-Charge. Make "Kirloskar/Upadhaya/ZOLOTO" complete of following sizes: -
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
400 mm bore
S&F in repair butterfly valves gear operated having epoxy coated cast iron body, PN 1.6, ISI marked ,GI disc with integral seat of nitrle rubber of the following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
400 mm bore
M&L for run lead joint for CI spigot and socket pipes and fittings of following size of pipes.
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Taking out sluice valves refacing, regrinding and refixing of following sizes all as specified and directed by Engineer-in-Charge :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for repacking of stuffing box of sluice valve spindle including taking apart and reassembling all as specified and directed by Engineer-in-Charge :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified
S&F mild steel angle iron framed work as in grills, grating, valve chamber etc using angle iron frame of size 35 mm x 35mm x 5 mm thick and 6 mm thick MS plate, framed guard bars including necessary locking arrangement all as specified and directed
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint (ordinary tint ) over a coat of red oxide primer complete all as specified and as directed.
MAINTENANCE OF FIRE FIGHTING SYSTEMS :
M&L for Quarterly maintenance and servicing of Fire hydrant pump House , Fire Hydrant , Sprinkler System of following by check up and preparation of log book and periodic report , servicing of complete system installed with in pump House and its connected spares/items such as valves, pumps, air cushion tank, pressure switches, gauges, Panels etc for daily routine check ( as specified below ) for smooth functioning as per the Manufacturers instructions by Employing experienced Mechanic complete all as specified and as directed by the Engineer-in-Charge. Note: (a) Spares / items as required for smooth functioning of system shall be measured and paid separately under relevant items. (b)Quoted shall be inclusive for servicing the entire fire system
(a) Quarterly checking of Diesel Engine driven fire pump, Jockey pumps & Electrical driven main fire pump including servicing greasing , overhauling, tightening of nut bolts and other spares shall be deemed to be inclusive in the quoted rate, consumable required for Diesel engine driven fire pump such as Diesel, coolant, lubricants and spares shall be measured and paid separately or provided by Department and ensuring that pump and engine shall be in proper working condition and ready for operation including preparing of service report and maintaining log book all as directed by Engineer-in-Charge.. (b) Quarterly checking of Pre charged Air vessel including servicing greasing , overhauling, tightening of nut bolts and other spares as required for smooth functioning shall be deemed to included in the quoted rate and making ensure that system shall be in proper working condition and ready for operation including preparing of service report and maintaining log book.
M&L for Quarterly maintenance and servicing of Fire alarm system by following checking up and demonstration with preparing of log book and periodic report of internal system along with servicing of complete system and its components such as Detectors, Panels, Manual call box, Hooters, etc for smooth functioning as per the Manufacturers instructions by Employing experienced Mechanic complete all as specified and as directed by the Engineer-in-Charge. Note: (a) Spares / items as required for smooth functioning of system shall be measured and paid separately under relevant items. (b)Quoted shall be inclusive for servicing the entire fire system
(a) Checking of pressure gauge & level indicator and replacing faulty PG with isolation ball valve . (b) Quarterly checking of HYDRANTS, SPRINKLER, PIPING including servicing ( greasing , overhauling, tightening of nut bolts and other spares, replacing of spares etc and related jobs) incuding preparing of service report and maintaining log book. (c) Quarterly checking, oiling, greasing ( if required)/ replacing Cost shall be inclusive of fixing only. (d) Quarterly checking, oiling, greasing ( if required) / replacing gate valves, butterfly valves, NRV, Check Valves, expansion bellows, spring-loaded valves , control valves, forged brass ball valve test assemblies etc (e) Quarterly checking, oiling, greasing ( if required) fire hydrant landing valve (f) Quarterly checking, cleaning and servicing of Hose reel drum for smooth functioning. (g) Checking of rubber reinforced lined fire hose (h) Checking of Main Control Panel for Fire Fighting pumps , including wiring , repairing and replacing of faulty cables, wires, and other components such as MCB, MCCB, relays, contactors etc
Supply only fire hydrant valve single headed
Supply only Fire hose reel 30 meter length with drum
Supply only Branch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 15 mm bore nozzle short
Supply only RRL Hose pipe 15 meter long 63 mm dia
Supply only fire brigade inlet connection (hydrant) 2 way
Supply only Air Release valve 25 mm brass
Supply only Forged Ball Valve 25/20 mm
S&F Air cushion Tank 200 mm dia with 25 mm dia relief valve
S&F in repair butterfly valves gear operated having epoxy coated cast iron body, PN 1.6, ISI marked SGI disc with integral seat of nitrle rubber of size 200 mm dia
S&F in repair butterfly valves gear operated having epoxy coated cast iron body, PN 1.6, ISI marked SGI disc with integral seat of nitrle rubber of size 150 mm dia
S&F in repair butterfly valves gear operated having epoxy coated cast iron body, PN 1.6, ISI marked SGI disc with integral seat of nitrle rubber of size 100 mm dia
S&F in repair butterfly valves gear operated having epoxy coated cast iron body, PN 1.6, ISI marked SGI disc with integral seat of nitrle rubber of size 80 mm dia
S&F sprinkler glass bulb type (Standard response) as per IS :15105 / TAC guidelines 68 Degree temperature rating Pendent type.
S&F short circuit isolators
Supply only Stainless steel Coupling set (male & Female) for RRL hose pipe 63 mm dia
S&F pressure gauge 8" Dial 0-21 Kgs rating
S&F pressure switch universal type
S&F HRFR single core stranded copper conductor cable of size 1.0 sqmm
S&F HRFR single core stranded copper conductor cable of size 1. 5 sqmm
S&F HRFR single core stranded copper conductor cable of size 2. 5 sqmm
Supply only detectors complying with and type certified to EN-45 addressable type smoke detectors photoelectric , Optical with base with self built intelligence as per IS :11360 as per existing make and compatible to existing alarm system.
Supply only addressable manual call point resettable type as per existing make and compatible to existing alarm system.
Supply only addressable electronic sounder cum strobe with flash light as per existing make and compatible to existing alarm system.
S&F Fire alarm sounders / sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 Db to 120 Db measured at 1.5 Mtr with sound output variation of ± 5 Db 500 Mtrs range
S&F in repair Sluice valves cast iron body, double flanged, ISI marked (IS-14846), heavy duty, class PN 1.6 gun metal, with non rising spindle of solid forged bronze and operating handle, including rubber gaskets, nuts, bolts, washers etc complete of following sizes all as specified and as directed by Engineer-in-Charge
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F battery 12 V 180 AH
S&F flow switch 150 mm dia
Disconnecting the Centrifugal pumps of capacity 12.5 HP of any make and model from motor and all water connections and removing / taking up from foundation, transporting to Authorised dealer workshop for repairing/strip opening of pump sets by changing the defective / unserviceable parts such as bearing, shaft, impeller, bush, Gland plate etc. complete and reassembling including oiling, greasing replacement of worn out nuts, bolts, gasket etc, and re-fixing in its original position at site and making all connections, commissioning and testing for smooth and noise free operation complete all as specified and as directed by Engineer-in-Charge. Notes :- (a). Bush, Gland plate & stuffing box packing, , O ring, Shoulder ring , Gasket Packing, Vent valve, Gland rope and Set of rubber oil seal etc shall be replaced if required and same shall be measured and paid separately under appropriate item of this schedule /BOQ as supply only. (b) T & P/ vehicle for transporting pump set shall be arranged by the contractor and quoted rate shall be inclusive for the same.
Supply only shaft sleeve Suitable for 12.5 HP Centrifugal Pump Set as per existing
Supply only oil seal suitable for Pump set upto Centrifugal Pump Sets upto 12.5 HP as per existing
Supply only gland plate with complete Nut & Bolt suitable for Centrifugal Pump Sets 12.5 HP as per existing
Supply only Lantern Ring suitable for Centrifugal Pump Sets 12.5 HP as per existing
Supply only coupling set suitable for centrifugal Pump Sets upto 12.5 HP as per existing
Supply only set of rubber gasket packing suitable for Pump Set 12.5 HP
Supply only set of O rings suitable for Centrifugal Pump Set 12.5 HP
CLEANING AND OPERATION OF SWIMMING POOL :
Taking out complete old filter media from filtration plant including gravel / sand of any size and stacking where as directed including cleaning of filters by scraping with the help of hard steel wire brushes and physical cleaning of surfaces by descaling / brooming slit and sludge's and other deposits from inner side ,collecting and taking out the deposit outside of installation , clean and washing properly with bleaching powder mixed water and preparing the surface and applying two coats of edible synthetic enamel paint over a coat of primer on entire inner surface and applying two coats of synthetic enamel paint over a coat of primer on entire outer surface complete all as specified and directed.
M&L for cleaning of filter media (Gravel and Sand) in hydro-chloric acid (HCL) and cleaning with fresh water to remove acid contents etc. complete
M&L for Re-filling of old gravels of various sizes in descending order in the filter beds, sizes varying from 02 mm to 10 mm thickness of the gravel layers all as specified and as directed . Note:Gravel obtained from sl. Item No 58 shall be re filled.
M&L for Refilling old filter media (Sand) in the filter bed complete all as specified and directed. Note: Sand obtained from sl. Item No 58 shall be re filled.
Supply and filling filter media (gravels) confirming to IS-8419 part-I 1977 in filter bed all as specified and directed
Supply and filling filter media (Sand) confirming to IS-8419 part-I 1977 in filter bed all as specified and directed
M&L for cleaning of station swimming pool of size 50 m x 21 m with depth 1.5m to 6 m, by scrapping with hard steel wire brush and emery paper, all wall tiles, floors channel (inside and outside) for removal of dust, algae etc. cleaning overall surface with water and applying chemical washing @ 40 ml per Sqm and further cleaning with water including taking out debris to outside empty land complete all as specified and directed at site by Engineer-in-Charge.
All as per item No 63.00 above but of aeration tower
All as per item No 63.00 above but of Balancing chamber
M&L for replacing PVC Suction pipe 50mm dia (reinforced as per existing) suitable for suction sweeper complete all as specified and as directed
M&L for cotton rope 20mm dia for suction sweeper fixed complete all as specified and directed
S&F in repair high density Ball high pressure of PTMT without accessories complete all as specified and directed (As per existing)
S&F in repair brush for cleaning of wall of swimming pool (as per sample) complete all as specified and directed
M&L for repairing and overhauling of suction sweeper by dismantling/ opening of sweeper by replacing of unserviceable parts such as PVC fibre wheel 04 Nos , MS wheel pin-08 Nos, brush of suitable size (as per existing) - 01 No, Nuts/bolts/washers (as per existing) approximately 05 Kg, including preparing surface of suction sweeper and accessories and applying two coat of synthetic enamel paint over a coat of primer and re-assembling complete suction sweeper in its original position including necessary testing complete all as specified and directed
Supply only water purification chemical (Make:- ION Exchange TCC 90) suitable for swimming pool in 50 KG sealed plastic container of latest batch complete all as specified and as directed. Note:- The TCC 90 chemical shall be supplied in Manufacturer's original packing duly marked with the date of Manufacturing and expiry. The dosing of TCC 90 Chemical shall be adjusted as per requirement and as per direction of Station Medical Rep during their visit to swimming pool.
Supply only Copper Sulphate suitable for swimming pool complete all as specified and as directed
S&F mild steel plates Fe 410-W (Gde E-250) quality- B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
S&F in repais foot valve ball type with rubberised steel ball and CI body flanged/screwed at the end of the suction line suitable for 150 mm dia pipe:- (Make : NORMEX or other equivalent make approved by GE).
Surface dressing in hard/dense soil ,not exceeding 15 cm deep and clearing off all types of vegetation, grass weeds etc in the swimming pool area complete all as directed . Note: Swimming pool shall be kept clean throughout the contract period by removing the grass / weeds as and when ordered by the Engineer-in-Charge any no of times depending on the growth of the grass,measurement and payment shall be made only once .
Supply and replace heavy duty suction sweeper brush assembly box type of size 300mm x 600mm made out of 6 mm thick MS plate, consisting nylon wheels, rubber bladder around and nylon brush all as directed.
S&F galvanised iron tubes 'Medium grade' with all fittings such as tees ,bends etc fixed complete to walls and ceilings or laid in floors of 150 mm bore Make:- TATA /Jindal
M&L for cleaning of swimming pool of size 50 M x 21 M with depth 1.5 m to 6 m, bottom and side walls by using suction sweeper fitted with nylon brush (twice in a week) all as specified and directed by Engineer-in-Charge.
Notes: (a) Suction sweeper fitted with nylon brush shall be provided to contractor by the Department.
(b) Repairs to the suction sweeper including replacement of leather/ rubber flaps, bolts/nuts, washers etc shall be carried out by the contractor without any extra cost.
(c) Quoted rate shall deem to be inclusive for maintaining the diving plate form and cleaning the sides walls of the swimming pool once in every month.
Supply only soda ash for the treatment of swimming pool water
Supply only caustic soda
Supply only orthotolodine solution in 500 ml bottle
Supply only chlorine testing kit with sample varying to .1 PPM to 4 ppm
S&F new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and top opening separate driver compartment with toughened glass having IP 66 protection and impact resistance of IK07 of capacity 45 Watt, powder coated grey finish including control gear (Inbuilt electronic driver with APFC, Lower THD Output short circuit protection, surge voltage protection, over voltage protection& other reliability test as per IS 15885 Part-2/Sec 13 complete all as specified.
S&F in repair butterfly valves gear operated having epoxy coated cast iron body, PN 1.6, ISI marked SGI disc with integral seat of nitrle rubber of the following sizes:-
150 mm bore
200 mm bore
250 mm bore
Disconnecting the Centrifugal pumps of capacity 15 HP to 20 HP of any make and model from motor and all water connections and removing/taking up from foundation, transporting to authorised / dealer workshop for repairing /strip opening of pumping sets by changing the defective/unserviceable parts such as bearing, shaft, impeller, bush, Gland plate etc. complete and reassembling including oiling, greasing replacement of worn out nuts, bolts, gasket etc, and re-fixing in its original position at site and making all connections, commissioning and testing for smooth and noise free operation etc complete all as specified and as directed by Engineer-in-Charge. Notes :- (a). Ball bearing, shaft, impeller, bush, Gland plate & stuffing box packing, Cooling tube with Banjo nut, O ring, Shoulder ring , Gasket Packing, Vent valve, Gland rope and Set of rubber oil seal etc shall be replaced if required and same shall be measured and paid separately under appropriate item of this schedule /BOQ as supply only. (iii) T & P/ vehicles for transporting shall be arranged by the contractor and quoted rate shall be inclusive for above provision .
Supply only shaft sleeve suitable for 15 to 20 HP Centrifugal Pump Set as per existing
Supply only oil seal suitable for Centrifugal Pump Sets upto 20 HP as per existing
Supply only Gland Plate with complete Nut & Bolt suitable for Centrifugal Pump Sets 15 to 20 HP as per sample
Supply only Lantern Ring suitable for Centrifugal Pump Sets 15 HP to 20 HP as per existing
Supply only coupling set suitable for centrifugal Pump Sets upto 20 HP as per existing
Supply only set of rubber gasket packing suitable for Centrifugal Pump Set 15 to 20 HP
Supply only set of 'O' rings suitable for Centrifugal Pump Set 15 to 20 HP
S&F mild steel Pipes with double flanged including bends and fittings of size 200mm dia, 6 mm thick complete all as specified and directed. Make : Jindal / TATA or other equivalent make approved by GE
S&F mild steel pipes with double flanged including bends and fittings of size 150mm dia, 6 mm thick complete all as specified and directed. Make : Jindal / TATA or other equivalent make approved by GE
S&F cast iron bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces single branch, 'Y' junction, double branch, cross (all socket or spigot and socket) collars, caps and plug upto 150 mm bore for spigot and socket end pipes complete all as specified and directed.
S&F cast iron bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double sockets etc.) tee pieces single branch, 'Y' junction, double branch, cross (all socket or spigot and socket) collars, caps and plug etc from size 200 mm bore to 400 mm bore for spigot and socket end pipes complete all as specified and directed.
Manning and operation of complete swimming pool and installed machineries (as listed below) as per standard operational requirement / Medical requirement / User's requirement by deploying one FGM for two shifts of eight hours each (Shif timing shall be as per direction of Engineer-in-Charge based on working requirement )
NOTE:- (a). Each Shifts shall be measured as unit (b). The operator should have good knowledge about the swimming pool operation and various motors, pumps measuring equipments, electrical equipments etc. Minimum qualification of operator shall be ITI in relevant trade or five years experience in relevant field. (c). The operator must adhere with the dress code as directed. (d). The operator must be highly skilled to attend the telephone calls and maintain the record. (e). The operator must be smart in conversation and well behaved. (f). The contractor shall be responsible for cleaning and upkeep of complete installation and premises and equipments. (g). The operator must maintain the documents like Log Sheets and Chlorine test register etc and the contractor shall provided the same as per the format in printed form as directed by Engr-in-charge. (h). Surrounding area inside the boundary wall/ fencing of the installation shall be neat and clean.
(j). All decorum and discipline shall be maintained since the swimming pool used for public, VIPs and Ladies. (k). As per Industrial Act one person should not be continued on duty more than six days in a week and he should be given weekly off day for his personnel maintenance and one reliever should be employed for off day by the contractor without any extra cost to the Govt. (L). Machineries shall be operated/ Maintained:- (ai) centrifugal Pump set Motor- 02 Nos, 15 HP - 01 Nos with LT panel and other accessories (bi) pressure filters - 02 Nos with Air Compressor and control valves (ci) Filling water in Swimming Pool whenever required by operating various valves, balancing tank etc. (di) Daily, Weekly, monthly, quarterly and half yearly checks to all machineries as per instructions given by the dep't. including all consumable materials such as cotton waste, grease, gland packing rubber sheets nuts bolts and washers etc. should be provided by the Contractor without any extra cost to the Govt.
Vinayak Trading House
Ankit construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .