| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹8.0 L+₹1.2 L (18.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹8.2 L+₹1.5 L (22.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹9.6 L+₹2.9 L (42.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹10.1 L+₹3.4 L (49.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
16 Jun 2020, 6:00 pmClosed
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2020_MES_335459_2
GE (AF) NAL/T-58/2019-20
Open Tender
Electrical and Maintenance Works
Item Wise
183 days
GE (AF) Nal
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹19,800
Yes
29 Jun 2020
26 May 2020
18 Jun 2020
26 May 2020
16 Jun 2020
3 Jun 2020
Amount
Attending day to day complaints for ceiling fan, exhaust fan and wall mounted fans installed at various locations in AF Stn Nal and rectifying the complaints complete all as directed by Engr-in-Charge. Note : (i) Defective parts / winding required to be replaced shall be measured and paid separately under respective items. (ii) Cost of taking down of fan and re-fixing where required shall be included in the unit quoted rate of this item
M&L Dismantling blades, down rod, canopy and taking out burnt stator assy of ceiling fan 48" sweep and taking down old burnt copper stator winding, cleaning stator slots, rewinding of stator assy with appropriate gauge of super enamelled copper winding wire, insulating material complete and assembling ceiling fan and testing for proper function including provision of split pin of suitable sizes and writing MES No., size of letters & figures 20mm x 25mm writing width 5mm complete all as specified and directed. Note: Cost of taking down of fan and re-fixing is included in unit rate of item No. 1 of this Schedule.
Supply and fixing as in repairs stator shaft as required for existing fan of any make/ size complete all as specified and directed. Note: Bearings shall be measured and paid as 'Supply only' under relevent item of this schedule.
Supply only self lubricated ball bearing of suitable size and make as existing complete all as specified and directed. Make : NBC/SKF/Tata
Supply only gun metal self lubricated bush bearings suitable for ceiling fan 48" complete all as specified and directed
Supply only fan condenser 2.5 mfd, 50 Hz, 240 Volts complete all as specified and directed. Make of fan condensor : EPCOS, Sunny, Havells, Hi-Power, Tibcon
Supply only fan condenser 4 mfd, 50 Hz, 240 Volts complete all as specified and directed. Make of fan condensor : EPCOS, Sunny, Havells, Hi-Power, Tibcon
Supply and fixiing flexible twin core PVC insulated copper cable of size 1.5 sqmm complete all as specified and directed. Make of PVC cable : Finolex, Polycab, RR Cable, Havells
M&L painting ceiling fan of sizes 48" sweep by dismantling, Scrapping out the existing paint from ceiling fan including fan blades, down rod and canopy etc and spray painting with one coat of approved quality synthetic enamelled paint complete and writing MES No. with size of letters & figures 20mm x 25mm writing width 5mm and re-assmbling including servicing the fan, greasing & oiling complete all as specified and directed. Note: Cost of taking down of fan and re-fixing is included in unit rate of item No. 1 of this Schedule.
Supply and fixing as in repairs fan regulator electronic step type 100 watt 230 Volt AC all as specified and directed. NOTE : Rate is inclusive for making hole on hylem sheet suitable for fixing electronic regulator in place of resistance type regulator. Make of fan regulator : Legrand, Cona, Anchor
Supply only down rod 45/60 cm of fan suitable as per site condition with rubber real, clamp, nut, bolts and spring complete all as specified and directed.
Opening the exhaust fan, removing the burnt copper winding wire complete cleaning the slots, stator and the rotors and rewinding the exhaust fan 250/300mm sweep with existing gauge super enamelled copper conductor including varnishing and heating and re-installation etc and re-assembling complete including writing MES No. size of letters & figures 20mm x 25mm writing width 5mm complete all as specified and directed. Note: (i) Spare / Part such as Bearing / winding to be replaced shall be measured and paid for separately as 'Supply only' under respective item of this schedule. (ii) Cost of taking down of fan and re-fixing is included in unit rate of item No. 1 of this Schedule.
All as per description of item No 1 here in before but 380/450mm sweep.
Supply only ball bearing suitable for exhaust fan 250 / 300 / 380 / 450mm sweep complete all as specified and directed. Make : NBC/SKF/Tata
Supply and fixing as in repairs metal louvers with frame suitable for 250/300mm sweep exhaust fan complete all as specified and directed (As per sample).
All as per item No 15 here in before but for 380 / 450mm sweep .
M&L Opening the cabin fan / wall mounted fan / table fan / pedastal fan 400 mm sweep, removing the burnt copper winding wire complete, cleaning the slots, stator and the rotors and rewinding with existing gauge super enamelled copper conductor including varnishing and heating and re-installation of fan etc complete including writing MES No. size of letters & figures 20mm x 25mm writing width 5mm complete all as specified and directed. Note: (i) Spare / Part such as Bearing / winding to be replaced shall be measured and paid for separately as 'Supply only' under respective item. (ii) Cost of taking down of fan and re-fixing is included in unit rate of item No. 1 of this Schedule.
All as per item No 17 here in before but 450mm sweep.
Supply only ball bearing suitable for cabin fan / wall mounted fan / table fan / pedastal fan of sweep 250 / 300 / 380 / 450mm complete all as specified and directed. Make : NBC/SKF/Tata
Supply and fixing as in repairs fibre made fan blade of table fan / cabin fan / wall mounted fan / pedastal fan, colour and size as per existing complete all as specified and directed.
Supply and fixing as in repairs metal grill cover of table fan / cabin fan / wall mounted / pedastal fan 250 / 300 / 380 / 450mm sweep of existing make and colour as specified and directed.
Taking down carefully point wiring (Light, fan, socket or power complete including fittings such as switches, Ceiling roses, pendants, regulator, sockets etc removing from site of work and making good to the disturbed surfaces of walls / floors etc all as specified and directed
Taking down carefully MCB SP/SPN/TPN off sizes & any capacity by unscrewing from DB box, emoving from site of work all as specified and directed.
M&L for Point wiring for One light/fan point controlled by one switch with PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including PVC concealed rigid conduit heavy duty (ISI mark) and pressed steel terminal boxes (for mounting switches / sockets / regulators / ceiling roses etc.) made out of MS sheet not less than 1.6 mm and 6 cm depth including painting with one coat of red oxide primer on internal and external surface covered with 3 mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke ( FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed . Note :- (i) The wiring shall be provided in standard colour code i.e. Red for Phase, Black for Neural and Green for earth. (ii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces. (iii) In case of ceiling portion where concelled donduiting is not possible, the surface conduit shall be provided ad directed. (iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed.
All as per description of serial item No. 24.00 here in before but for One 3-pin socket outlet 5 Amp on independent board.
All as per description of serial item No. 24.00 here in before but one 3 pin socket outlet 5 Amp on same board
All as per description of serial item No. 24.00 here in before but for one 5 pin socket outlet 5/6 & 15/16 Amp on indipendent board with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed.
M&L Point wiring for One light / fan point controlled by one switch with PVC insulated fire retardant Low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including surface stove enamelled steel conduit and pressed steel terminal boxes ( for mounting switches / sockets / regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm and 6 cm depth including painting with one coat of red oxide primer on internal and external surfaces covered with 3mm thick laminated bakelite sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke ( FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed Note :- (i)The wiring shall be provided in standard colour code i.e. Red for Phase, Black for Neural and Green for earth. (ii) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed.
All as per description of serial item No. 28.00 here in before but for One 3-pin socket outlet 5 Amp on independent board.
All as per description of serial item No. 28.00 here in before but one 3 pin socket outlet 5 Amp on same board
All as per description of serial item No. 28.00 here in before but for one 5 pin socket outlet 5/6 & 15/16 Amp on indipendent board with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed.
Supply and fixing Switch piano flush type single pole one way 5/6 amp complete all as specified and directed..
Supply and fixing Switch piano flush button single pole one way 15 amp complete all as specified and directed.
Supply and fixing Socket out let 3 pin 5 amp multipurpose, flush type complete all as specified and directed.
Supply and fixing Socket out let 2 in 1, 3 pin, 5 and 15 amp multipurpose, flush type complete all as specified and directed.
Supply and fix Ceiling rose surface Bakelite 65 x 50 mm three terminals complete all as specified and directed.
Taking out carefully the existing burnt sub main wiring of size 4 Sqm / 6 Sqmm PVC insulated multi stranded aluminum conductor cable along-with earth continuity conductor from the PVC / rigid steel, concealed/surface conduit complete all as specified and directed.
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metalic conduit 25mm dia ISI marked and accessories surface fixed on wall / floor etc all as specified. Note :- 3 run of 4 sq mm with 1 run of conduit shall be measured as single unit length.
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke(FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metalic conduit 25mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note :- 3 run of 6 sq mm with 1 run of conduit shall be measured as single unit length.
Supply and laying Sub main wiring (concealed) complete with four single core 6 sqmm fire retardant low smoke (FRLS) PVC insulated unsheathed multi stranded copper conductor cable LT 1100 V grade drawn through and including 32 mm dia non metalic regid PVC medium grade conduit and conduit accessories including 6 sqmm fire retardant low smoke (FRLS) PVC insulated unsheathed multi stranded copper earth cable connected to common earth dolly complete including cutting chasing in walls for concealed wiring using cutting mechine and making good the disturbed surface complete all as specified and directed. Note :- 4 run of 6 sq mm , 1 run of PVC conduit & 1 run of 6 sqmm cable shall be measured as single unit length.
Supply and fixing as in repairs sheet metal enclosure for SPN DBs with double glazed door for incorporating MCBs IP 43, 8 way with 200 amp rated busbar, 240 volts as per IS 8623, all as specified and directed. Make :- Legrand /L&T/Havells
Supply and fixing as in repairs sheet metal enclosure for DBs with double door for incorporating MCBs IP 43, TPN 4 way with 200 amp rated busbar, 240 volts as per IS 8623, all as specified and directed. Make :- Legrand /L&T/Havells
Supply and fixing as in repairs Vertical TPN DB double door suitable for fixing 100 amp MCCB, IP 45 protection with powder coated enclosure 4 way insulated busbar assemblyo rating 200 Amps including MCCB 4 pole, 415 V, 100 A, 16 kA - 01 No complete all as specified and directed. Make : IndoAsian / Legrand/ ABB.
Supply and fixing MCB four pole 63 Amps 16 KA, 415 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of copper lugs etc. complete all as specified and directed.Make :- Legrand /L&T/Havells
Supply and fixing MCB SPN 40 Amps 10 KA 240 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of lugs etc. complete all as specified and directed. Make :- Legrand /L&T/Havells
Supply and fixing MCB SP 6 to 32 Amps 10 KA 'C' curve 240 volts 50 Hz including making necessary incoming and outgoing connection with suitable size of lugs etc. complete all as specified and directed.Make :- Legrand /L&T/Havells
Supply and fixing as in repairs LED tubelight fitting Decorative box type, prewired LED tube, blue coloured end caps complete all as specified and directed. Make: Havells / Phillips / Crompton Greaves
Suply and fixing Lamp holder angular PVC polycarbonate type with back plate suitable for PVC casing capping/conduit fitting complete all as specified and directed.
Supply and fixing as in repairs sheet metal enclosure single pole and neutral encolsure with two pin and earth plug and socket complete with provision for fixing of one MCB SP 20 Amps complete all as specified and directed. Make Havells cat part No DHDPUSN020/DHDPUDP020 or equivalent in /Phillips/Crompton Greaves
ENGINEER CORPORATION OF INDIA
rajesh builders
RAJENDER ENTERPRISES
DASHMESH ENTERPRISES
BIDAWAT ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .