Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹61.4 LAdmitted-Finance | -24.50% | ₹61.4 L | L1 | Admitted-Finance |
| 2 | L2₹63.1 LAdmitted-Finance | -22.50% | ₹63.1 L | L2 | Admitted-Finance |
| 3 | L3₹63.3 LAdmitted-Finance | -22.20% | ₹63.3 L | L3 | Admitted-Finance |
| 4 | L4₹65.9 LAdmitted-Finance NEAR ANKANA SCHOOL SRIT COLONY SAMBALPUR BUDHARAJA 768004 | SAMBALPUR | ODISHA | 768004 | -18.99% | ₹65.9 L | L4 | Admitted-Finance |
| 5 | L5₹67.3 LAdmitted-Finance | -17.25% | ₹67.3 L | L5 | Admitted-Finance |
Tender Value
₹81.4 L
EMD Value
₹81,400
Closing Date
19 Jan 2026, 4:00 pmClosed
SE R AND B DIV-I, SBP
O/O SE R AND B DIV-I, SBP
Building works
2026_EICCL_124294_1
SE/R AND B/SBP/14/2025-26
National Competitive Bid
Civil Works - Buildings
240 days
Sambalpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹81,400
Yes
O/O SE R AND B DIV-I, SBP
20 May 2026
7 Jan 2026
20 Jan 2026
7 Jan 2026
19 Jan 2026
7 Jan 2026
7 Jan 2026 - 17 Jan 2026
7 Jan 2026
CIVIL WORKS
Cleaning & grubbing road land including uprooting rankvegetation, grass ,bushes, shurbes, sapling and trees girth upto 300mm, removal of stumps of trees cut earier and disposal of unsevicable materials and stacking of servicable materials to be used or auctioned up to lead of 1000 meters including removal and disposal of top organic soil not exceeding 150mm thickness.
Earth work in excavation of foundation in HARD soil within 50m lead and 1.5m lift including rough dressing and breaking clods to maximum 5cm. To 7cm. And laying in layers not exceeding 0.3m in depth and as per specification complete.
Up to (1.5m to 2m depth)
Filling in foundation, trenches and plinth with river sand, well watered and compacted in layers of 1.8 mtr, with top surface dressed and leveled to proper gradient including cost of all materials, conveyance, all taxes and royalties, loading and unloading, including cost of all labour, sundries, T & P etc. All complete as per directions of the Engineer -in-charge.
Filling available excavated earth (excluding rock) in trenches plinth sides of foundation etc. in layers not exceeding 20 cm in depth , consolidating each deposited layers by ramming and watering, lead up to 50m and lift up to 1.5 mt etc. including cost of all labour, sundries T & P etc complete in all respect as per the direction of Engineer-In-Charge.
Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge.
Providing & applying of pre constructional anti-termite treatment Confirming to IS 6313 (Part-II) and creating chemical barrier under and around the column pits, wall trenches, basement excavation top surface of plinth filling, junction of wall and floors along with external perimeters of building, expansion joints, surrounding the pipes and conducts etc. at the rate at 7 ,5 liter per sqm on vertical surface and 5.0 liter per sqm on horizontal surface. Chemicals:- Imidachloprid 30.5 SC , Doses: - 2.1 ml per lit of water cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-incharge. (Make :- HI-Solution or Smart Care Pest Control or Bharat Pest Eradicators)
Fly Ash brick masonry in cement mortar (1:6) in Substructure using Fly Ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
Foundation
Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 %) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc.complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
Foundation and plinth
Footing
Column / Pedestal
Plinth Beam
Ground Floor
Column
Staircase
Lintel
Chhaja
Roof Beam
Roof Slab
First Floor
Column
Staircase
Lintel
Chhaja
Roof Beam
Roof Slab
Terrace Floor
Column
Lintel
Chhaja
Roof Beam
Roof Slab
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.
Foundation and plinth
Ground Floor
First Floor
Terrace Floor
Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 Cm. x 11 Cm. x 8 Cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
Ground Floor
First Floor
Terrace Floor
Providing Fly ash bricks masonry work using 23 Cm. x 11 Cm. x 8 Cm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:4). Immersing the bricks in water before use in all necessary projection splays cutting, circular moulding, corbelling etc. Including cost of conveyance ,taxes & royalties, loading and unloading of all materials & cost of all labour, scaffolding ,watering & curing ,sundries, T & P etc. complete as per the direction of Engineer-in-charge .
First Floor
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
Ground Floor
First Floor
Terrace Floor
Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
Ground Floor
First Floor
Terrace Floor
Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
Ground Floor
First Floor
Terrace Floor
Providing and installing two component acrylic modified cementitious waterproofing coating with Nerolac Perma Guard 2K/ sikatop seal 109 or Equivalent with Nerolac Perma Fibre Mesh 45 GSM over roof slab after carring out pond test on roof slab filling all defects. Saturating the surface mixing the products and then application in 1.0 mm thickness (1.8kg/sqm coverage rate for 1.0mm thickness) in suitable layers complete in all respect all material, tools, plant & labour complete in all respect. Density 1850kg/m3, mix ratio (Powder to liquid ) 2:1 by weight water.
Terrace
Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.
Terrace
Providing and laying vitrified floor tiles of size 600 mm × 1200 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily separately). DSR 2023 Vol-1 Cl -11.41A.2.2 P-180
First Floor
Providing and laying Vitrified tiles in sizes (600mm x1200mm) (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
First Floor
Grouting the joints of flooring vitrified tiles 600mmx1200mm having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-incharge. (DAR-2023 Vol-1 Clause No-11.48.3(pg-836))
First Floor
Fixing Granite Tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.
Ground Floor
First Floor
Fixing Granite Tiles of approved dimension area above 0.4 sqm (20mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.
Ground Floor
First Floor
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.
First Floor
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat size (65 x 125 mm )comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).DSR 2023 SL No-26.86.6 P-342
First Floor
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. SOR 2022 P-235 SL No-12
Ground Floor
First Floor
Terrace Floor
Providing and fixing of UPVC (Un Plasticized Poly Vinyl Chloride) Sliding windows (Make: Fenstech) Ventilator made out of hollow- chambered UPVC Sections having isolated drainage and reinforced throughout with galvanized steel. The ventilator shall be made out of UPVC sections having an overall size of 60mm x 60mm x 2mm thickness. Structurally Reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.2mm with moldings glazing Beading (up 5mm) with interlocking system. Prefabricated & welded through fusion welding the window outer frame & sash shall be fitted with 5mm thickness Pin-Head glass of reputed brand (Saint Gobain Glass) make duly fixed with EPDM rubber, weathering sealant & Accessories like louvers made by brand. The outer frame is to be installed at the side using anchor fastener, Silicon Rubber Sealant, easy glazing at the side. At least 15 years manufacturing warranty for discoloration, wrapping, mechanical failures, Shrinkages, Rooting Corrosion etc. with a quality Certificate from relevant departments of that government through the Dealers including of all materials and abounds etc. Complete as per directions of Engineer in-charge
First Floor
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.
Ground Floor
First Floor
Terrace Floor
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
Ground Floor
First Floor
Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge).
Ground Floor
First Floor
Terrace
Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. (Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge)
Ground Floor
First Floor
Terrace Floor
Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-charge)
Ground Floor
First Floor
Terrace Floor
Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ Dulex/ ICI or equivalent make duly approved by Engineer-in-Charge)
Ground Floor
First Floor
Terrace Floor
Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
Ground Floor
First Floor
Terrace Floor
E.I. WORKS
Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei) with 20 mm dia HMS FRLS PVC conduit ISI marked (Make- Akg / Bec/ Precision/ Norpak/ Anchor/ Kinjal) 6A modular type (anti bactorial & flame retradant type) switch ISI marked (Make- Schneider (Zencelo)/ legrand (Myrius- Next Gen)/ Panasonic (vision)) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) (Make-Schneider ( Zencelo)/ legrand ( Myrius-Next Gen) /Panasonic (vision)) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Group-A
Group-B
Group-C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei) in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying, fixing of 6A Switch Socket on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) ((anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. (Make-Schneider (Zencelo)/ legrand( Myrius-Next Gen)/ Panasonic (vision). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying, fixing of 6A Switch Socket on the separate switch board with complete fitting by 02 nos of 6A switch & socket (modular type) ((anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. (Make-Schneider (Zencelo)/ legrand (Myrius-Next Gen)/ Panasonic (vision). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A switch socket on the separate board with complete fitting by 01 no of 16A switch & socket (modular type) ((anti bactorial & flame retradant type)) with suitable size modular box & cover (anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( Myrius- Next Gen)/ Panasonic (vision) (For equipement power) All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying and fixing AC point consisting of 20A socket outlet Modular type along with 25A starter with all connections and accessories as required as per direction of Engg.-in-Charge.(Make-Schneider/Siemens/Legrand)(For Split AC)
SUB MAIN WIRING
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable (Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kable/ Kei) in recessed HMS FRLS PVC conduit of mentioned size (Make- Akg/ Bec/ Precision/ Norpak/ Anchor/ Kinjal) as required as per direction of Engg.-in-Charge.
2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/ Light Ckt) (2X1.5+1X1.5)
2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (BDB to LSB/ Light Ckt/ 5A socket/ UPS Point) (2X2.5+1X1.5)
2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (PDB to PSB/ Power Point/ AC Point) (2X4+1X1.5)
2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (LFDB TO LBDB/ UBDB) (2X6+1X2.5)
4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (LFDB TO LBDB/ Medical equipement) (4X6+2X2.5)
4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (LFDB TO LBDB/ Medical equipement) (4X10+2X4)
LIGHTING FIXTURES
Note: Dummy box for surface mounted fixtures only, fans and exhaust fans with all accessories, as required.(The colour temprature for fixtures shall be above 4000 deg K, CRI Min 80 & white in colour as per application)
Supplying and fixing of Energy efficient surface/ recess mounted square/ round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj).The luminaire should be replacement warranty will be 2 years
Supplying an fixing of recess/ surface mounted 2'x2' 36 W square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj). The luminaire must be Replacement warranty will be 5 years.
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj). The luminaire should be Replacement Warranty will be 2 years .
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro / Crompton/ Bajaj) The luminaire should be Replacement Warranty will be 2 years
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .
Supply and installtion of 9Watt LED lamp of Phillips EyePro B22 LED Bulb on existing angle/batten holder or equivalent.
Supplying and fixing step regulator modular type on the existing switch box including connections but excluding box etc. as required as per direction of Engg.-in-Charge.
S/F of Street light- 45W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty)
Supply, delivery and fixing of Ceiling fan hook box made out of 18 swg GI sheet and containing 10 mm dia round ms bar projecting atleast 150mm on either side & duly bent to accommodate ceiling fan down rod bolt & having earthing arrangement as per direction of Engineer-in-charge.
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required as per direction of Engg.-in-Charge.
Supplying, installation, testing and commssioning of 1200 mm sweep white/ milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/ min (Make- Crompton Energion Groove/ Havells Efficiencia Neo/ Usha Technix) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge, Replacement Warranty will be 4 years. (With fan Regulator)
S/F. Of 400mm High Speed Wall fans including all connections and accessories of Usha/ Orient/ Havells/ Equivalent make
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/ Crompton/ Usha/ Orient/ Bajaj) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement warranty will be 2 years.
DISTRIBUTION BOARD
TPN Mcb DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door warranty on DB is 3 years
8Way (8+24), Double Door
4 way (8 + 12), Double door
Supplying and fixing of following ways surface/ recess mounting, Horizonttal type, 230 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
12 way (2 + 10), Double door
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing 63Amps 4P 415 volts MCB (Make-Legrand- DX3 / Siemens- Betaguard/ Schneider- Acti 9) in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 3 years.
Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA (Make- Legrand- DX3/ Siemens- Betaguard/ Schneider- Acti 9) in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The RCCB should be Replacement Warranty will be 3 years.
Supplying and fixing 32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of (Make- Legrand -DX3 / Siemens-Betaguard/ Schneider- Acti 9) in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be replacement warranty will be 3 years.
Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity, SP, 230 volts, MCB (Make- Legrand- DX3/ Siemens-Betaguard/ Schneider- Acti 9) in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be replacement warranty will be 3 years..
Cables, Cable Laying & Termination
Supplying & Testing of 1.1 KV grade Aluminium XLPE Armoured power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (make:- Polycab/ Havells/ Gloster or equivalent)
3.5C X 70 sqmm
CABLE LAYING
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required.
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required.
TERMINATION OF CABLES
Supply & Making end Termination with brass compression gland and Cu/aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) (make:- Comet/ Dowells or equivalent)
3.5C X 70 sqmm
Earthing
Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years
Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as
Supply and Installation of 2000 VA, 24 Volts UPS ISI marked including all connections and accessoriea as required.(Make:- Luminous/ Microtek/ Livguard or Equivalent)
Supply and Installation of 150 AH tall tubular Battery ISI marked including all connections and accessoriea as required.(Make:- Exide/ Luminous/ Livguard or Equivalent)
Supply and Fixing of troley for inverter double battery.
FIRE EXTINGUISHER
Note : [1] All Fire Extinguisher shall be HCFC, CFC and Halons free. [2] The Fire Extinguisher Manufacturer/Supplier shall provide declaration, Technical Data Sheet/cutsheet of All type of Fire extinguisher to be installed.
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body,squeeze lever discharge valve fitted with internal discharge tube, ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge with CO2 gas conforming to IS : 307-1996..
Capacity 4.5 kg. I.S.I. Marked. (IS : 15683 : 2006)
Providing and fixing ABC stored pressure dry chemical powder (mono ammonium phosphate) Fire Extinguisher IS : 15683 latest revision manufacturer and of CRCA sheet in welded construction, finish with High quality epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzle, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases).
Capacity 6 Kg (IS : 15683 : 2006)
P.H. WORKS
Internal Sanitary & Plumbing System
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.
In First Floor-
20mm dia C-PVC pipe
25mm dia C-PVC pipe
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.
32mm dia PVC ASTM pipe (sch-80)
40mm dia PVC ASTM pipe (sch-80)
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
110mm U-PVC SWR Pipe (Ashirvad/Supreme Make)
80mm U-PVC SWR Pipe (Ashirvad/Supreme Make)
110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)
110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
75mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
75mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
110mm PVC SWR Clamp/clip(Ori Plast/Finolex/Supreme Make)
Supply,Providing, fixing, testing and commissioning in position UV stabilised 110 mm dia PVC Rain water pipe with Fittings (IS: 13592 Type - B). In case of ceiling hanging, the supply of Pipe Clamps (Chilly/MS angle) as per engineer in charge.110 mm diameter.
110 mm dia PVC (IS:13592, Type -A)
Supply, Providing and fixing 150 mm x 150 mm.dia CI Grating for Rain water pipes 110 mm dia.
150 mm x 150 mm.dia CI Grating (Parryware/ Hindware/Grohe/Jaguar)
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
European water closet with 'p' trap plain(Hindware/Parryware/Neycer make)
Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge.
10 litres PVC L.L. Cistern with flush bend . (Parryware/ Hindware/ Grohe/ Jaguar)
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. (Parryware/ Hindware/Cera/Jaguar)
550mmx400mm Half pedestal wash.basin
560mmx450mm size under counter basin
32mm dia PVC waste pipe with brass coupling nut (Astral/Finolex/ Industries/AKG/Supreme/Ashirbad)
15mm dia PVC inlet connection pipe 0.45m long (Astral/Finolex/ Industries/ AKG/Supreme/Ashirbad)
Supplying all materials, labour, T&P, fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the EIC.(Parryware/ Hindware/ Grohe/Jaguar)
15mm dia CP two in one bib cock (FLR-ACR-5041N)
15mm dia CP angle stop cock (FLR-ACR-5053N)
15mm dia CP Angle stop cock
15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
15mm dia CP extension piece
PVC Connection Pipe
PVC Discharge Pipe
15mm dia. C.P flange
125mm dia CP gratting
25mm dia brass or gun metal fullway valve(Shakti Make)
32mm dia brass or gun metal fullway valve(Shakti Make)
Supplying all materials,labour,T&P and fixing standard sized Glass-shelf, Towel Rail, Towel Ring, Soap Holder, Soap dispenser with C.P brass bracket and guard rail complete fixed to wooden pluges with screw etc.all complete as per specification and direction of Engineer-in-charge.
600mmx125mm size glass shelf with C.P ruard Rail.
25mmx600mm long CP Towel Rail. (Parryware/ Hindware/Grohe/Jaguar)
C P Towel Ring (Parryware/ Hindware/Grohe/Jaguar)
C P soap Holder. (Parryware/ Hindware/Grohe/Jaguar)
C P Soap Dispenser. (Euronics/Bobric/Sloan/Prestge/Nirali)
C P Toilet Roll Holder. (Parryware/ Hindware/Grohe/Jaguar)
Supplying all materials, labour, T&P and fixing of Stainless Steel Coat Hook alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever complete in all respect as per specification and direction of the Engineer in charge.(Parryware/ Hindware/Grohe/Jaguar)
Stainless Steel Coat Hook AKP -35761P
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge.
600mmx450mm size B.E mirror (swivelled type)
Supplying all materials, labour, T&P and fitting and fixing G.M/ Brass fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. (Zoloto/Advance/CRI/Sant/Kartar)
25mm dia Brass F.W valve
32mm dia Brass F.W valve
32mm dia CPVC Ball valve
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. (Supreme/Finolex/Industries/Astral/AKG/Syntex)
Fixing 2000Ltr Roto-moulded water storage tanks-In First floor
B-Civil Works Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.
250mm thick wall in First floor
Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.
In First Floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
In First Floor
Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC / HCI pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge . 250mm to 375mm thick wall
first floor
Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge .
Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge .
first floor 24.23x0.05
Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1"-6" in wall including cleaning, applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. first floor(Flooring) Floor Tile Area - 24.23 (Dado) (52.31/3.60)x0.45 = 6.54 17.69
Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
First Floor
Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site, payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge (Vitrified floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/ Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge )60cmx60cm
First Floor
Grouting the joints of flooring vitrified tile 600x600mm having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resinper kg), including filling / grouting and finishing complete as per direction of Engineer-incharge.(DAR-2023 Vol-1 Clause No-11.48.2(pg-836))
Supplying all materials, labaour, T&P and fixing ceramic floor tiles in dados skirting on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed ith pigments to match the shades of the tiles etc. complete as per direction of the Engineer-in-charge.(ceramic vitrified Glazed tiles in wall of size 300x600 ) of make Johnson/Kajaria/Somany/Orient Bell/Rak) plain/printed series to be pre-approved by the Engineer-in-charge.
First Floor 12mm Plaster area-(52.31/3.60)x2.1=30.51
Providing and applying two coats of Synthetic Matt enamel paint of desired shade, on internal wall surfaces wherever required at all heights to give an even and uniform shade of approved brand as per manufacturer specification to give a smooth and even surface including thoroughly brushing the surface free from water / mortar dropping and other foreign matter and sandpapered smooth, complete per manufacturers specifications and as directed.
First Floor 12mm Plaster area-(52.31/3.60)x1.45=21.07
Providing and applying Plastic Bison Emulsion paint of approved make & in approved shade conforming to IS: 15489 . Applying 2 coats of paint with roller to all internal walls at all levels over a coat of water-based BP White primer / Alkali resistant primer including preparation of surfaces by cleaning .Surfaces so prepared shall be completely dry and free from dust before painting is commenced. Scaffolding, labor, tools, tackles, equipment etc complete to achieve a smooth, even and consistent surface
First Floor Qnty. Same as Cement Primer FF- 21.07
Finishing plastered surfaces of walls with Bw Waterproof Wallseal putty of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
First Floor Qnty. Same as Cement Primer FF- 21.07
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge.
First Floor 5x0.76x2.13
Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge. 5 x 4.95
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
SlNo1.pdf
Tender Documents • 3.00 MB
BOQ_574772.xls
BOQ • 0.75 MB
Download all tender documents and submit your bid