| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAdmitted-Finance 18 PAALIKA BAZAR RAMPURA NEAR NEXA SHOWROOM PAALIKA BAZAR JAGADHARI YAMUNANAGAR YAMUNANAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L1 | Admitted-Finance | |
| 2 | L2₹27.2 L+₹1.8 L (7.14%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹24.4 L−₹89,194 (3.52%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹23.7 L−₹1.6 L (6.29%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹26 L+₹65,806 (2.60%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Puri Engineering Electricals L3 | Shanti Enterprises L5 | GANPATI COMMUNICATION SERVICES L2 | M/S Jindal Electricals L4 | VISHAL ENGINEERING COMPANY L1 | KHUSHI ELECTRIAL SOLUTIONS L6 | ELECTECH SWITCHGEAR PRIVATE LIMITED L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SITC of Radiator Cooled and Turbo charged Silent DG Set (As per CPCB 4 plus emission norms) having specifications as per A, B, C, D, E, F,G,H & I | ||||||||||
| 2.00A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP (125 kVA & Above ratings 6 cylinder or above required ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber), up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . | ||||||||||
| 3.00B) AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled | ||||||||||
| 4.00C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. | ||||||||||
| 5.00D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : | ||||||||||
| 6.00E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA. | ||||||||||
| 7.00F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. | ||||||||||
| 8.00G) Servicing Contract of DG Set from OEM's Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. | ||||||||||
| 9.00H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. | ||||||||||
| 10.00I) DG set will be offered for Inspection and Testing at Manufacturer's Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge. | ||||||||||
Tender Value
₹32.2 L
EMD Value
₹64,340
Closing Date
28 Aug 2025, 6:00 pmClosed
Executive Engineer
RSAMB Electric Division Jaipur
SITC of 250 KVA DG Set at SIAM Durgapura, Jaipur
2025_RSAMB_492830_1
RSAMB/Elec/NIT-07/2025-26
Open Tender
Electrical Works
Percentage
Jaipur
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
EE RSAMB Electric Division Jaipur
₹64,340
Yes
1 Sept 2025
11 Aug 2025
29 Aug 2025
11 Aug 2025
28 Aug 2025
15 Aug 2025
Amount
SITC of Radiator Cooled and Turbo charged Silent DG Set (As per CPCB 4 plus emission norms) having specifications as per A, B, C, D, E, F,G,H & I
A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP (125 kVA & Above ratings 6 cylinder or above required ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber), up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required .
B) AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled
C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade.
D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :
E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA.
F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.
G) Servicing Contract of DG Set from OEM's Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department.
H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration.
I) DG set will be offered for Inspection and Testing at Manufacturer's Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.
250 KVA at 0.8 pf 415V 50Hz 3-ǿ
Bidder Name
Amount
Puri Engineering Electricals (GSTN-08AKLPG6372N1ZJ) BID ID -3277395
Shanti Enterprises (GSTN-08ABHPA4131G1Z6) BID ID -3278820
GANPATI COMMUNICATION SERVICES (GSTN-08AMAPG7177L1ZP) BID ID -3286186
M/S Jindal Electricals (GSTN-08AEJPJ5458A1ZL) BID ID -3286218
VISHAL ENGINEERING COMPANY (GSTN-NA) BID ID -3279087
KHUSHI ELECTRIAL SOLUTIONS (GSTN-NA) BID ID -3279140
ELECTECH SWITCHGEAR PRIVATE LIMITED (GSTN-NA) BID ID -3278756
ELECTECH SWITCHGEAR PRIVATE LIMITED (BID ID -3278756)
Puri Engineering Electricals (BID ID -3277395)
KHUSHI ELECTRIAL SOLUTIONS (BID ID -3279140)
VISHAL ENGINEERING COMPANY (BID ID -3279087)
Shanti Enterprises (BID ID -3278820)
GANPATI COMMUNICATION SERVICES (BID ID -3286186)
GANPATI COMMUNICATION SERVICES (BID ID -3286186)
Puri Engineering Electricals (BID ID -3277395)
M/S Jindal Electricals (BID ID -3286218)
Shanti Enterprises (BID ID -3278820)
KHUSHI ELECTRIAL SOLUTIONS (BID ID -3279140)
ELECTECH SWITCHGEAR PRIVATE LIMITED (BID ID -3278756)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .