Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.6 L+₹50,445 (3.57%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹14.8 L+₹64,855 (4.59%)Rejected-Finance 91 B LAXMI NAGAR AIRPORT ROAD INDORE INDORE MADHYA PRADESH 452005 UDYAM MP 23 0000211 | INDORE | MADHYA PRADESH | 452005 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹14.8 L+₹70,880 (5.02%)Rejected-Finance SUBAN BAZAAR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹15.4 L+₹1.2 L (8.83%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
25 May 2022, 6:00 pmClosed
GARRISON ENGINEER SOUTH DIGLIPUR
Garrison Engineer (South) Military Engineer Services, RK Gram, Diglipur North Andaman - 744 202
PROVISION OF COVER SHED FOR DIESEL GENERATOR (100 KVA) AND GENERATOR OPERATOR DUTY/ REST ROOM NEAR OTM BUILDING AT MAYABUNDER
2022_MES_522301_1
8868/E8
Open Tender
Civil Works
Item Rate
180 days
Diglipur
ALL BIDDERS ENLISTED WITH MES IN CLASS E AND CAT ai AND UNENLISTED BIDDERS MEET MES
ENLISTMENT CRETERIA OF CLASS E AND CAT ai REFER NIT
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SOUTH DIGLIPUR
₹29,000
Yes
20 Jul 2022
6 May 2022
27 May 2022
6 May 2022
25 May 2022
20 May 2022
7 May 2022 - 12 May 2022
Amount
Rough excavation not exceeding 1.5 m deep and getting out in any type of soil.
Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out in hard/ dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface.
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/ loose soil or hard/ dense soil.
M&L for PCC Type D2, 1:4:8 (using 40mm graded granite stone aggregate) as in foundations, filling and mass concrete.
M&L for RCC M-30 (design mix) (using 20mm graded crushed granite stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete.
M&L for RCC M-30 (design mix) (using 20mm graded crushed granite stone aggregate) as in columns, pillars, piers, posts and struts.
M&L for RCC M-30 (design mix) (using 20mm graded crushed granite stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span
M&L for providing steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for flat rough finished surfaces of concrete all as specified.
M&L for providing steel formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, for flat fair finished surfaces of concrete all as specified.
M&L for providing steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for flat rough finished surfaces of concrete all as specified.
M&L for high yield strength deformed TMT steel bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L for high yield strength deformed TMT steel bars 6 mm to 8 mm dia as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L Pre-cast cement concrete Type C1, 1:3:6 (using 20mm graded crushed granite stone aggregate), block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4 complete.
M&L for broken stone hardcore of guage exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/ rammed to a true surface.
M&L 40 mm thick PCC Type B0, 1:2:4 (using 12.50 mm graded crushed granite stone aggregate) laid in flooring and pavings, etc. finishing surfaces of concrete even and fair (without using extra cement) complete all as specified.
M&L for non - skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15 mm thick in CM 1:4 complete.
M&L for glazed coloured ceramic tiles (best quality) 350x250x7 mm or 450x350x7 mm thick on vertical surface as in dado/ skirting, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including back coat of 10 mm thick in CM 1:4 complete.
M&L for rendering 10 mm thick in two coats (5 mm + 5 mm) in cement mortar 1:6 with adding water proofing compound and 12 mm long synthetic fibre on fair faces of brick work or concrete surfaces like RCC wall, slab surfaces, finishing the surface fair and even complete all as specified. (Water proofing compound shall be measured and paid separately).
M&L for rendering 15 mm thick in two coats (10 mm + 5 mm) in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finishing the surface as sand face finish complete all as specified.
M&L for preparing new plastered surfaces of walls and applying two coats of distemper oil emulsion paint over a coat of alkali resistant priming paint.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete.
S&F Anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frames and shutters including sliding tracks etc. for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. fittings like hinges, handles and locks etc complete all as specified.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, in opening as per specification & drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed.
S&F 75 mm long butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type E-12.
S&F 125 mm long extruded aluminium alloy handles, fabricated type, anodised.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, as per manufacturer instructions as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, as per manufacturer instructions as specified.
S&F ERW or Induction butt weld M.S. tube black conforming to IS 1161-1979 grade Yst 240 and rolled mild steel sections as main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410 -W (Gde- E- 250) quality- A.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
M&L for wash basins, vitreous china (flat back or angle back type) 580x450 mm size, including cutting for and pinning in ends of brackets or erecting stand inclusive of fixing of supply and waste pipe.
S&F 15 mm bore Pillar taps, cast copper alloy, chromium plated, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
M&L for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests, including flushing cistern and flush pipe, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including trap set in and including concrete making good to floor.
M&L for Vitreous China urinals, bowl type of 465 x 355 x 265 mm white (minimum) (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Inclusive of fixing supply pipe to flushing cistern, trap and waste pipe).
S&F 15mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F 15 mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors
S&F false ceiling 4 mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium frame work with screws fixed in ceiling flat or sloping.
Excavating over areas, not exceeding 1.5 m deep and getting out in any type of soil.
M&L for PCC Type C2, 1:3:6 (using 40mm graded granite stone aggregate) as in concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in 150 mm bore CI pipe.
M&L precast RCC Type B1, 1:2:4 (using 20 mm graded granite stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in CM 1:4, including necessary formwork complete. Note: Reinforcement shall be measured and paid separately.
S&F 150 mm bore cast iron (sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints in 1:1 laid in trenches or in floors.
Supply only Integral waterproofing compound.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose soil.
Removing excavated soil material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No. in and including PVC casing and caping with all fittings such as internal bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories, with GI pressed steel / PVC box suitable for modular switches sunken boxes (with earth dolly) covered with logic modular PVC sheet cover for fixing of switches, sockets etc including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- NOTE: - Switch and socket to be measured and paid for separately. (a) One light point controlled by one 5/ 6 Amps one way switch.
All as per item No. 46 here-in-before, but for One ceiling fan/ exhaust fan point controlled by one 5/ 6 Amps one way switch.
Description all as per item No. 46 herein before, but for One socket out let 5/ 6 Amps point on the same board.
Description all as per item No. 46 herein before, but for One socket out let 5/ 6 Amps point on the independent board.
Description all as per item No. 46 herein before, but for wiring with 2.50 Sq mm single core copper conductor for one socket out let 15/ 16 Amps point on the independent board.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqdcomplete all as specified
S&F modular switch flush type single pole, one way 5/ 6 Amp complete.
S&F modular switch socket combination 3 pin, 5/ 6 Amp flush type universal.
S&F modular socket outlet 2 in 1, 5 pin, 5/ 6 Amp, flush type.
S&F modular switch socket combination 2 in 1, 5 pin, 5/ 6 and 15/ 16 Amp flush type universal.
S&F ceiling rose, bakelite, surface type, 220/ 240 volts, three terminals complete all as specified and directed.
S&F lamp holder, insulated body, with back plate suitable for batten/ angle fittings.
S&F sheet metal enclosure for 8 way Distribution Board (DB), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates complete all as specified and as directed.
S&F MCB, single pole and neutral, 32 Amps, 240 volts, 'C' curve, 10 KA complete all as specified and as directed.
S&F MCB, single pole, 6 to 32 Amps, 240 volts, 'C' curve, 10 KA complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth wire 4mm dia and 7.50 mtrs connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exceeding 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No. 3 of schedule Part-I (2009).
S&F energy efficient surface and wall mounted LED batten 20 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours complete all as specified and as directed.
S&F LED Lamp 1 x 09 Watts retrofit type. Make: C&S Cat No. LTHPLEDLAMP9W/B22 / Surya or equivalent
S&F GI bracket suitable for fixing of street light fitting by fabricating the size of 32 mm dia. light grade GI pipe of length 1.50 mtr with suitable bend complete all as specified and directed.
S&F new generation energy saving and environmental friendly 35 watts building LED light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver complete all as specified and directed.
S&F exhaust fan AC single phase heavy duty steel body 300 mm sweep 1400 RPM complete with louvers including fixing/ grouting of frame in wall opening complete and connecting with including 3 single core PVC insulated copper conductor flexible cable of size 23/0.0076 (or equivalent, size in mm).
S&F ceiling fan complete with blades, down rods and accessories, 230 V, 1200 mm sweep, with squirrel cage induction motor and connecting up including provision of 2 core flexible PVC cable with stranded copper conductor of size 0.75 mm from ceiling rose to connector of ceiling fan all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm.
Supply and spreading clean, fine, dry river sand in trenches for cushioning of under ground cable/ inside transformer yard complete all as specified and directed. Note: Only punned thickness shall be measured for payment purpose.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheated, armoured with aluminium strip, galvanised wire, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 2 core 10 Sqmm.
M&L for 40 mm bore GI pipe light grade with necessary fittings in trenches/ floor/ pillar/ fixed on pole etc for cable protection complete all as specified and directed.
Supply and lay 25 mm outer diameter 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, floors including fittings.
Supply and fix 25 mm outer diameter PP-R Gate valves (brass insert) as per requirement of the site.
RMS Construction
M/s Sharma Trading Company
MOHAMMED SAFIQUE
M/s Kamal Electrical
M/s Mohammed Shamim
RPG AND COMPANY
P Babu
S K ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .