Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.0 CrAdmitted-Finance 2 284 JANKIPURAM VISTAR LUCKNOW UTTAR PRADESH 226021 UDYAM UP 50 0011144 | LUCKNOW | UTTAR PRADESH | 226021 | -16.30% | ₹6.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.4 CrAdmitted-Finance | -11.10% | ₹6.4 Cr | L2 | Admitted-Finance |
| 3 | L3₹6.5 CrAdmitted-Finance 560 SADAR BAZAR JHANSI UTTAR PRADESH 284001 UDYAM UP 39 0009380 09AACFT8755H1ZP R M | JHANSI | UTTAR PRADESH | 284001 | -9.14% | ₹6.5 Cr | L3 | Admitted-Finance |
Tender Value
₹7.2 Cr
EMD Value
₹14.4 L
Closing Date
12 Mar 2026, 10:30 amClosed
Superintending Engineer, Electrical Circle, UPAVP,
Office of the Superintending Engineer, Electrical Circle UPAVP, Lucknow Office Complex, Vrindavan Yojna-2, Lucknow.
External Electrification Work H.T., L.T., Transformation and Street Light Work at Sector-20, Vrindavan Yojna No 4, Lucknow.
2026_UPHDB_1120784_1
183/M-6 ED-I/36 Dated 26.02.2026
Open Tender
Electrical Works
180 days
Vrindavan Yojna No 4, Sector-20
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,850
Executive Engineer, ED-I, U.P.A.V.P., Lucknow
₹14.4 L
Yes
17 Mar 2026
27 Feb 2026
12 Mar 2026
27 Feb 2026
12 Mar 2026
27 Feb 2026
H.T. Works
S/Erection of 11 KV section Double pole structure (Riser) made of following types of supports duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) Plinthed, Plastered and painted in the same manner as already specified for respective supports with one nos. channels of size 100x50mm and 75x40mm M.S. channel and 2 Nos. bracing of angle iron size 65x65x6mm 3M length fixed with packing piece and bolt and nuts as required including cost of material, labour and T & P required for proper completion of work as per direction of E/I.
11 Mts. long 410 SP-55
Supply of following size 3 Core 11 KV H.T. cable standered compacted circular Al. conductor screen with Extruded Semi conducting compound, XLPE insulated in copper Tape, cores laid up to innersheath of PVC, Galvanised Steel Strip Armoured & overall sheathed cable confirming to IS 7098 (Part-2) 2011 with upto date Ammendments complete in all respect as per Direction of E/I. Make (Polycab/ Gloster/KEI/Finolex /Universal/ Havells)
120 Sqmm 3 Core
300 Sqmm 3 Core
Supply and jointing of 11 KV jointing kit (Heat Sink) per XLPE cable including cost of all material Labour and T & P as per proper completion of work as per direction of E/I. Make (Raychem/3M /Densons) as per DSR 2022 S.No. 10.5.4
120 Sqmm 3core Outdoor
300 Sqmm 3core Outdoor
Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 110 mm 6.50 mm thickness complete in all respect as per relevants I.S. Technicals specification.
Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 160 mm 9.50 mm thickness complete in all respect as per relevants I.S. Technicals specification.
Digging & Refilling of Same Trench Parallel to Road at a depth of 1.5 Mtr. as required & laying charges of cable & different size HDPE Pipe (PN-6 PE 80 Grade) complete with all material, labour and T&P etc. required for proper completion of work as per Direction of E/I.
S/F of following type of G.I. pipe "B" class for cable clamped with supports by 3 Nos. clamps made of 20x3mm M.S. flat and suitable size of nut bolt and washer required for proper completion of work as per direction of E/I. Make(TATA/SAIL/JINDAL)
80 mm dia
100 mm dia
Making suitable earthing of ST poles with 2.5Mts. long 20mm dia M.S. rod with 7/16 SWG G.S. wire in 15mm dia 2Mtr. long G.I. pipe duly clamped with 3 nos clampes and binding on poles including cost of labour & T & P etc. required for proper completion of work.
S/F of danger board (H.T.) size 200x250 mm at suitable height of pole as per direction of E/I
S/F of barbed wire (1.5kg) duly clamped with 20x3mm M.S. flats at both ends on steel poles at suitable height as per direction of E/I.
S/F of cable route marker made of 1:2:4 R.C.C. Block size 1000x400x10 mm grouted with 1:3:6 cement stone grit coarse sand 30cm below G.L. with painting numbering & marking etc. complete with all required material T&P etc. complete in all respects as per direction of E/I.
L.T. Transformation
Supply and Erection of Double Pole Structure made of following types of support duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) plinthed, plastered & painted in the same manner as already specified for respective supports sutable for plinth mounted type substation with different types of M.S. Channel and angle iron duly fabricated for disc fittings D.O. fuse set, TPMO ladder stand projecting outside dropper and bracings , including cost of all material, labour and T & P required for proper completion of work as per drawing and direction of E/I.
With 11 Mts. long 410 SP 55 S.T. Pole
Supply and Erection of 11 KV TPMO set complete in all respects ( as per Specification No. 21)
Supply and Erection of 11 KV D.O. fuse set complete in all respects. ( as per Specification No. 22)
Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole, lightning arrestor and transformer. The rates include the cost of all materials, labour and T & P etc. required for proper completion work.
Supply Installation, Testing and commissioning of 11 /0.433 KV Transformer of following capacity as per BIS 1180-2014 Standard. The rates also including loading unloading local carriage and T & P charges etc.
250 KVA, 11/0.433KV (Level-1)
400 KVA, 11/0.433KV (Level-1)
Supply, installation, testing and commissioning of Outdoor Type,dust and vermin proof weather proof with rain canopy on four sides with locking arrangement, 630A/800A ACB L.T Panel Fabricated out of 2.0mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. All indicating lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The panel shall be completed in all respect and shall consist of following material. Incomer: 630A/800A F.P Manual Fixed type A.C.B with Metering (ie Ameter with ASS, Voltmeter with VSS) along with, Phase Indicating Lights, CT,Control MCB etc. -1 Set Panel will have suitable rating (1Amp/Sqmm) of Aluminium Bas bar for Proper Temination of Cables. ( minimum 400 sqmm6 nos ) All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports.
S/F of lightening arrestor set (3 Nos.) suitable for mounting on steel supports complete with all materials, labour and T & P required of proper completion of work as per direction of E/I. Page No.
Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henley's Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I.
Incoming : Two (2) Nos. 300 Amp. Fuse unit
Outgoing : Four (4) Nos. 300 Amp. Fuse unit
Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henley's Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I.
Incoming : Two (2) Nos. 500 Amp. Fuse unit
Outgoing : Six (6) Nos. 300 Amp. Fuse unit
Design, Supply & Testing of 630A Outdoor type LT Outdoor Feeder Pillar rabricated out of 2.0mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Busbar of Panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation of continuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit as fault level require. The Feeder Pillar shall be completed in all respect and shall consist of following material.
Incoming : Two (2) Nos. 500 Amp. Fuse unit
Outgoing : Six (6) Nos. 300 Amp. Fuse unit
Supply Intallation testing and commissioning of 300A sub Feeder Pillar. The Feeder Pillar shall be fabricated outof 2.0mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of EngineerIn?Charge after proper sheet treatment process of sheet steel. The Busbar of Panel shall be of High gradeElectrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation ofcontinuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure bear the jerks of shortCircuit as fault level require. The Fault level of Panel shall be 50kA for 1sec. The Feeder Pillar shall be dust & Vermin Proof ,weather proof , rain canopy all four sides ,locking arrangements with Degree pf Protection IP : 55. The Feeder Pillar shall be completed in all respect and shall consist of following material. Incomer : 300A Kit Kat type Fuse Unit – 3 Set with Neutral Bus Bar Outgoing: Suitable Bus Bar only with Provision to connect atleast 30 Nos. Outgoing Cables . up to 3.5 core 35sqmm size
Construction of fencing plinth of following sizes in Ist class brick work including plaster and providing flat bricks soling and pointing the same with 1:2 cement and fine sand mortar over 75mm thick cement concreting in the ratio 1:6:12 in open space of the cage as per direction of E/I and drawing.
6x4x0.23m for Substation
2X3X0.23m for feeder Pillar
2x3x0.23m for Subfeeder Pillar
Supply of fixing of 2.45M. High cage fabricated with 3.0mm thick expanded metal/wire mesh of equivalent weight fixed on 50x50x6mm angle iron frame having vertical members spaced at 1.0M to 1.25M. and horizontal members spaced at 1.20M the vetical members shall be grouted in ground and horizontal members in the wall to a depth of 300mm with ends folded. The cage shall have 1000x2000mm size single leaf door with locking arrangement having door frame fabricated with 35x35x5mm angle iron and 3mm expanded metal wire mesh of equivalent weight duly fixed with the cage member. The cage shall have nut bolt arrangement for opening the sides by providing tees 45x20cm of angle iron size 50x50x6mm as per direction of E/I. It shall be painted with red oxide primer and synthetic enamelled paint as per direction of E/I. including all materials, labour and T & P for proper completion of work.PWD SOR 2018 SI No. 1142
Supply and burring of Safe Earthing Electrode T-39 ( Hot Dip Galvanized) Length up to 3000mm, outer Dia 76 mm inner 38 mm, terminal Dia 12mm, outer G.I. Pipe of 16 SWG & Inner G.I. Pipe 12 SWG with Hot Dip Galvanization upto 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm Square C.I. Frame with hinged cover & masonry housing.( from Electrode Terminal to switch board, cost of 25 x 3 G.I. Strip will be extra) As per PWD SOR-2018 S.I. No.-725 (D) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified
Construction of plinth for Transformer size 2.0x1.25x1.0 Complete With all materials, labour and T & P required for proper completion of work as per specification drawing and direction of E/I.
Supply of following size of Al. conductor XLPE Insulated, Cores Laid up, PVC Innersheathed, Armoured with Galvanised Al. Strip Extruded PVC Type ST2 Outer Sheathed, 650V/1100 Volt Grade as per IS 7098 (Part I) 1988 With up to date Ammendments Make Polycab/Gloster /Finolex /Universal /KEI /Havells
240 Sqmm 3½ core
120 Sqmm 3½ core
Supply & Laying of following Size of Al. Conductor PVC Insulated armoured served sheathed cable 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S Clamps etc. of suitable size or as directed by the E/I. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps as per PWD SOR 2024 S.No. (20a1.18) & (20a1.20)
240 Sqmm 3½ core
400 Sqmm 3½ core
Supply and fixing of palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as per PWD SOR 2018 SI No. 504 (h), (j), (m) & ( o)
Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouribg of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. as per PWD SOR 2018 S.No. 503 (o) (r) & (t)
120 Sqmm 3½ core
240 Sqmm 3½ core
400 Sqmm 3½ core
Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 110 mm 6.50 mm thickness complete in all respect as per relevants I.S. Technicals specification.
Digging & Refilling of Same Trench Parallel to Road at a depth of 1.5 Mtr. as required & laying charges of cable & different size HDPE Pipe (PN-6 PE 80 Grade) complete with all material, labour and T&P etc. required for proper completion of work as per Direction of E/I.
S/F of cable route marker made of 1:2:4 R.C.C. Block size 1000x400x10 mm grouted with 1:3:6 cement stone grit coarse sand 30cm below G.L. with painting numbering & marking etc. complete with all required material T&P etc. complete in all respects as per direction of E/I.
S/F of danger board (H.T.) size 200x250 mm at suitable height of pole as per direction of E/I As Page No.
Construction of brick masonary service chamber with cover in cement mortar (1 cement: 4 coarse sand) R.C.C top slamb with 1:2:4 mix(1 cement:2 coarse sand: 4 graded stone aggregate 20mm, nominal size) foundation concrete in 1:6:12 (1 cement:6 coarse sand and 12 graded stone aggregate 40 mm nominal size) inside blastering 12mm thick with 1:4 cement & Coarse sand) finished with floating coat of neat cement complete inside size 0.45x0.45x0.60m with class 150 Brick. Page No.
Street Light Works
Supply & fixing of 9 mtr. GI Octagonal Pole of approved make (top dia 70 mm, Bottom dia 155 mm and base plate 16 mm thick) having 3 mm thickness with single arm bracket length of 1 mtr length in 1:2:4 RCC Foundation bolt including the cost of foundation, excavation & back filling and Required T&P complete in all respect. UP PWD SOR 2024 SI No-21.2.4 Make Bajaj/Vallmont/RRISPAT CONSOUL (Without GST Rate 30046.00x0.8475=25464.00)
Supply and fixing of LED Street Light Fitting with mandatory driver set having die cast aluminium body with toughend glass/UV stabilized PC Cover and lenses suitable for 75 Watt to 90 Watt and Confirming to IP 66, and IK07 and above protection having company LOGO Engraved complete in all respect including Labour. 9000-10800 system lumens, High Power LED with lenses, 120 Lm/W, PF>0.95, THD<10% at full load, CRI>70, Potted driver set in Metal housing (Not Circuitory) phase to phase protection at 440V & >300V auto cut and re-start feature, 4 KV internal surge protection with 5 years warrantee.CAT-AAA PWD SOR 2024 SI No-23.16 Make Havells/Polycab/Philips/Jaquar (Without GST Rate 10124.00x0.8475=8580.00)
S/F of following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect UPPWDSOR 2018 SI No-807
Making suitable earthing of PCC/ST poles with 2.5Mts. long 20mm dia M.S. rod with 7/16 SWG G.S. wire in 15mm dia 2Mtr. long G.I. pipe duly clamped with 3 nos clampes and binding on poles including cost of labour & T & P etc. required for proper completion of work.
Supply and Burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length 3000 mm, outer pipe 76.30 mm x 3.2 mm inner pipe 42.40 mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing UPPWD SOR-2018 item no. 726 (D) Make as approved in UPPWD & CPRI Certified
Supply and laying of following size of Al. conductor PVC insulated armoured, served sheathed cable 1100V grade at a depth of 75cm. below ground level over a cushion of 75mm thick sand alround and protected with brick on sides And Top. On surface the cable run shall be fixed on M.S. clamp etc. on suitable size and crossing the road, cable should run through 140mm dia hume pipe and in case of air like catenary it shall be hanged with the help of G.I. wire, clipped at several places as per direction of E/I for proper completion of work. The armouring of cable shall be properly connected with earth conductor by clamp etc.as per PWD SOR 2018 SI No. 501 (i) & (k) Make Polycab/Gloster/Finolex /Universal /KEI /Havells
16 Sqmm 4 Core
35 Sqmm 3.5 Core
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.74 MB
BOQ_2084944.xls
BOQ • 0.38 MB
biddocument.pdf
Tender Documents • 16.87 MB
Download all tender documents and submit your bid