| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹149.2 CrAccepted-AOC | ₹149.2 Cr Quoted ₹1.5 Cr | I | Accepted-AOC accepted |
| 2 | II₹1.5 CrRejected-Finance SF NO 454 RAGHUPATHYNAICKENPALAYAM RAILWAY COLONY POONDURAI MAIN ROAD ERODE | ERODE | ERODE | TAMIL NADU | ₹1.5 Cr | II | Rejected-Finance REJECTED |
Tender Value
₹149.2 Cr
EMD Value
₹1.5 Cr
Closing Date
7 Mar 2024, 3:00 pmClosed
Commissioner kancheepuram Corporation
Kancheepuram Corporation Annai Indira gandhi Salai Kancheepuram
Improvements to Existing water supply scheme for Kancheepuram City Municipal Corporation - Package 2
2024_MAWS_415456_3
9327/2023/E1
Open Tender
Civil Works - Water Works
365 days
kancheepram corporation
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.5 Cr
Yes
14 Nov 2024
14 Feb 2024
7 Mar 2024
14 Feb 2024
7 Mar 2024
14 Feb 2024
14 Feb 2024 - 7 Mar 2024
Amount
Supply and delivery of following sizes of DI K7 Class s/s pipes as per IS: 8329 / 2000, at the site of work etc., complete and as directed by Engineer in charge. DI Pipes 350mm
Supply and delivery of following sizes of DI K7 Class s/s pipes as per IS: 8329 / 2000, at the site of work etc., complete and as directed by Engineer in charge. DI Pipes 300mm
Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical Specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge 280mm
Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical Specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge 250mm
Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical Specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge 200mm
Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical Specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge 180mm
Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical Specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge 160mm
Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical Specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge 140mm
Supplying and conveying to site, the following sizes of HDPE pipes of class PN6 (PE-100) confirming to IS:4984/1995, as specified in Technical Specifications in standard lengths including labour charges for loading, unloading and stacking at site and transportation charges etc., complete as per standard specifications and as directed by the Engineer in Charge 110mm
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge 350mm
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge 300mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Tees 280mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Tees 250mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Tees 200mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Tees 180mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Tees 160mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Tees 140mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Tees 110mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Bends 280mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Bends 250mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Bends 200mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Bends 180mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Bends 160mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Bends 140mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. Bends 110mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. End caps 280mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. End caps 250mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. End caps 200mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. End caps 180mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. End caps 160mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. End caps 140mm
Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.. End caps 110mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B DI Pipes 350mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B DI Pipes 300mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B HDPE Pipes 200mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B HDPE Pipes 180mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B HDPE Pipes 160 mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B HDPE Pipes 140 mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B HDPE Pipes 110 mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil.SS20B HDPE Pipes 280mm
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil.SS20B HDPE Pipes 250mm
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers. DI Pipes 350mm
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers. DI Pipes 300mm
Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. HDPE Pipes 280mm
Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. HDPE Pipes 250mm
Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. HDPE Pipes 200mm
Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. HDPE Pipes 180mm
Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. HDPE Pipes 160mm
Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. HDPE Pipes 140mm
Lowering the following pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. HDPE Pipes 110mm
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. DI Pipes 350mm
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. DI Pipes 300mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. HDPE Pipe 280mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. HDPE Pipe 250mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. HDPE Pipe 200mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. HDPE Pipe 180mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. HDPE Pipe 160mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. HDPE Pipe 140mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by Department Officers. HDPE Pipe 110mm
Barricading work (Where the lines are in narrow width of municipality area, busy streets like Market, Bus-stand and in the Highways etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia. and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by Department Official. Over All Length
Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by Department official. Over All Length
Disposal of surplus earth including loading, conveyance within a distance of 5 km and spreading as directed by the Engineer in charge. Over All Length
Labour charges for cutting of B.T road or WBM roads for laying of mains and as directed by Engineer in charge. Over All Length
Labour charges for cutting of C.C road or WBM roads for laying of mains and as directed by Engineer in charge. Over All Length
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge DI Pipes 350mm
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge DI Pipes 300mm
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge HDPE Pipes 280
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge HDPE Pipes 250
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge HDPE Pipes200
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge HDPE Pipes 180
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge HDPE Pipes 160
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge HDPE Pipes 140
Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge HDPE Pipes 110
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. 350mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. 300mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. 250mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. 200mm/180mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. 160mm/140mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. 110mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 350mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 300mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 280mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 250mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 200mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 180mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 160mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 140mm
Testing of pipes for water supply with hydraulictesting equipment by filling with water (includingcost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including otherincidential and operational charges etc., complete for the following diametres of pipes. 110mm
DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing. For 350 mm Dia - 350mm
DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing. For 300 mm Dia - 300mm
DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing. For 250Dia - 250mm
DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing. For 200 mm Dia - 200mm
DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing. For 140, 160 mm Dia - 150mm
DI Pressure Reducing and Flow Limit Control Valve (PN10/16) with the function to reduce higher upstream pressure into a preset lower downstream pressure and to not allow flow rate in the line to exceed beyond the defined set point. The flow orifice diameter is designed based on the set point as per the design requirement. The set point can be changed to a maximum of +10%. “Manufacture supply and delivery of DI D/F Diaphragm type own medium controlled Pressure Reducing and flow limit control valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. 2 pressure gauges for operator-friendly control to determine the actual inlet and outlet pressure connected directly to the valve. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.” Pilot valve system having Stainless Steel / Brass fittings with spring of stainless steel 304 as per standard parts according to DIN EN 12 266-1 and Stainless steel 316 orifice plate shall be as per the set point of flow rate, all the external control tubing of SS 304 / Copper/ reinforced plastic rated PN16, Tightness to DIN EN 12 266-1, leakage rate A (or) equivalent and the needle valve/ speed control device should be provided to vary opening speed of the main diaphragm with self- cleaning filter to avoid possibility of dirt build up inside the control tubing. For 110 mm Dia - 100mm
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. For 350mm Dia - 350mm
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. For 300 mm Dia - 300mm
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. For 250 mm Dia - 250mm
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. For 200 mm Dia - 200mm
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. For 140, 160 mm Dia - 150mm
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. For 110 mm Dia - 100mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. For 350 mm Dia - 350mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. For 300 mm Dia - 300mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. For 250 mm Dia - 250mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. For 200 mm Dia - 200mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. For 140, 160 mm Dia - 150mm
Supply, delivery to site, fixing & Commisioning of CI sluice valve to pressure rating PN1.0 with ISI mark with 5 Years warranty, for isolation confirming to IS 14846/2000 with necessary rubber insertions, bolts & nuts including loading & unloading ,transporting charges taxes & duties etc. complete at site as per standard specification and as directed by engineers of the following sizes. For 110 mm Dia - 100mm
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 350 mm Dia DI
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 300 mm Dia DI
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 280 mm Dia HDPE
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 250 mm Dia HDPE
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 200 mm Dia HDPE
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 180 mm Dia HDPE
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 160 mm Dia HDPE
Supply , delivery and fixing of D.I. specials as per IS 9523/2000 at site etc., complete as directed by Engineer in charge. Flange & Socket Tail Piece - PN10 For 110 mm Dia HDPE
D.I. D/F Piece-PN10 As per IS 8329/2000 For 350 mm Dia DI
D.I. D/F Piece-PN10 As per IS 8329/2000 For 300 mm Dia DI
D.I. D/F Piece-PN10 As per IS 8329/2000 For 280 mm Dia HDPE
D.I. D/F Piece-PN10 As per IS 8329/2000 For 250 mm Dia HDPE
D.I. D/F Piece-PN10 As per IS 8329/2000 For 200 mm Dia HDPE
D.I. D/F Piece-PN10 As per IS 8329/2000 For 180 mm Dia HDPE
D.I. D/F Piece-PN10 As per IS 8329/2000 For 160 mm Dia HDPE
D.I. D/F Piece-PN10 As per IS 8329/2000 For 110 mm Dia HDPE
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers For 350 mm Dia HDPE
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers For 300 mm Dia HDPE
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers For 250 mm Dia HDPE
Lowering of HDPE Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers For 200 mm Dia HDPE
Lowering of HDPE Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers For 160 mm Dia HDPE
Lowering of HDPE Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the Department Officers For 110 mm Dia HDPE
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. For 350 mm Dia HDPE
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. For 300 mm Dia HDPE
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. For 250 mm Dia HDPE
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. For 200 mm Dia HDPE
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. For 160 mm Dia HDPE
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. For 110 mm Dia HDPE
Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) For 350 mm Dia DI
Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) For 300 mm Dia DI
Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) For 250 mm Dia HDPE
Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) For 200 mm Dia HDPE
Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) For 160 mm Dia HDPE
Jointing the C.I/ D.I-S/S pipes and specials with neat cement or cement mortar and spun yarn including caulking the joints, curing. (including cost of jointing materials) For 110 mm Dia HDPE
HSC for HDPE Mains 1)Labour for cutting open road for laying water mains or sewer.B.T. Roads (or) Maccadam road 2)Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil. 3)HSC Connection in HDPE Mains for Water Supply Scheme , delivery of the following Electrofusion tapping saddle PE 80 blue, PN 12.5 with female threaded metal insert of SS 304 as per standards BS EN 12201 tested as per BS 6920 for drinking water in WRCNSF ltd, UK. (Non Wrap with top loading type). Sizes:63mm to 315mm dia distribution HDPE pipes. shall as detailed in a drawing furnished. 4)Supply, delivery of Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS :554 BSPT, ISO:7- 1 to suit the corresponding bore sizes of 15mm dia size ( 1/2", ) in the saddle Connection .as per IS :554 BSPT, ISO:7-1 5)Supply, delivery of Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRCNSF LTD, UK suitable for 20mm, OD MDPE pipes 6)Supply, delivery of Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mmOD MDPE pipes 7)Supply, delivery Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 20mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm respectively. 8)Supply, delivery of MDPE PE 80 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK 9)UPVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRCNSF LTD, UK,size : 20mm ODx1/2"ID, 25mm ODX1/2"ID and 32mm OD X 3/4" ID 10)Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the Department Official11)Supply and delivery of multi jet water meter with removal mechanism water merers confirming to ISO 4064 Class B or IS 779 standards with type test certificates for Routine Test, IP 68 Test certificates issued by FCRI/NABL Accredited Lab. The water meter shall have magnetic or mechanical drivers or shall ber versatile for installation in horizontal position. The meters shall be hydrodynamically or hydrostatically balanced. The runner, runner chamber, pointers of the meter shall be as per ISO 4064 Class B Specification. Dry dial excavated counter housing fully protected against floodings ensuring easy reading in all climatic conditions. The meters shall be inferntial, Dry-Dial Type, Class B with Straight reading Cyclometer with inbuild filter basket, meter body shall be of Brass body confirming to DCB2 material specification and suitable for drinking water applications 12)Lowering MDPE pipes and specials to the trench and laying to proper grade and alignment, jointing with couplers with cement past etc complete for the pipes size upto 40mm dia OD MDPE Pipes 13)Jointing MDPE Pipes and Specials by butt fusion weldiEng / electro fusion welding joints using fusion equipment as per ISO 21307- 2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per HDPErected by Department Officers. 14)Supply, delivery and fixing of GI pipes for encasing in open drain including handling charges. etc complete as per standard specifications and as HDPE erected by the Department Officers 15)Refilling with excavated soil (other than sand complying with the standard specification for filling in foundation and basement (total earth work quantity - volume of the pipe) 20mm
Earth work excavation -Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth SS 20 B
P.C.C 1:4:8 (one cement, four sand and Eight coarse aggregate) using cement and 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the Corporation Engineers.
P.C.C 1:2:4 (one cement, two sand and four coarse aggregate) using Sulphate Resistant cement and 20 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the Corporation Engineers.
Earthwork excavation and depositing on bank for foundation, with an initial lead of 10m and initial lift of 2m including shoring, strutting and all other incidental works, as directed by the departmental Officers in the following classification of soil. Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders. All soil (First depth of 2M)
Earthwork excavation and depositing on bank for foundation, with an initial lead of 10m and initial lift of 2m including shoring, strutting and all other incidental works, as directed by the departmental Officers in the following classification of soil. Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders. Soft Disintegrated Rock
Earthwork excavation and depositing on bank for foundation, with an initial lead of 10m and initial lift of 2m including shoring, strutting and all other incidental works, as directed by the departmental Officers in the following classification of soil. Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders. (Second depth of 2M)
Earthwork excavation and depositing on bank for foundation, with an initial lead of 10m and initial lift of 2m including shoring, strutting and all other incidental works, as directed by the departmental Officers in the following classification of soil. Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders. Medium Dense Rock (First depth of 2M)
Earthwork excavation and depositing on bank for foundation, with an initial lead of 10m and initial lift of 2m including shoring, strutting and all other incidental works, as directed by the departmental Officers in the following classification of soil. Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders. Medium Dense Rock (Second depth of 2M)
Removing hard Rock by wedging,chiseling and trimning to proper shape where blasting is prohibited. Second Depth
Stone Dust filling for foundation with river sand including consolidation ramming etc. complete as per standard specifications and as directed by the Engineer-incharge
Plain Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification 1.5m to 4.5m below GL
Plain Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification Upto 1.5m below GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). Upto 1.5m below GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). From 1.5m to 4.5m below GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). upto 4.5m above GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 4.5m to 7.32m above GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 7.32m to 10.98m above GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 10.98m to 14.64m above GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 14.64m to 18.3 m above GL
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 18.3 to 21.96 m above GL
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL Curved Surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL 3.30 - 4.30M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL 3.30 - 4.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL 3.30 - 4.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL 3.30 - 4.30M above GL Curved Surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& aboveGL 4.30 - 5.30M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& aboveGL 4.30 - 5.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& aboveGL 4.30 - 5.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL 5.30 - 6.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& above GL 5.30 - 6.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& GL 6.30 - 7.30M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& GL 6.30 - 7.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& GL 6.30 - 7.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& GL7.30 - 8.30M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& GL7.30 - 8.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& GL7.30 - 8.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 8.30 - 9.30M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 8.30 - 9.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 8.30 - 9.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 9.30 - 10.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 9.30 - 10.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 10.30 - 11.30M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 10.30 - 11.30M above GL Plane surface Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 10.30 - 11.30M above GL Plane surface Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 11.30 - 12.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 11.30 - 12.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 12.30 - 13.30M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 12.30 - 13.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 12.30 - 13.30M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 13.30 - 14.30M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 13.30 - 14.30M above GLCircular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 14.30 - 15.3 M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 14.30 - 15.3 M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 14.30 - 15.3 M above GL Curved Surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 15.3 - 16.3 M above GL Plane surface
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 15.3 - 16.3 M above GL Square column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 15.3 - 16.3 M above GL Circular column
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) Upto 3.30 M Below GL& 15.3 - 16.3 M above GLCurved Surface
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) Rods for reinforcement
Brick work in CM 1:5 (one cement and five sand) using country bricks of size 8.75" X 4.25" X 2.00" including cost of all materials, labour charges, curing etc., complete and as directed by the Engineer incharge.
Plastering with CM 1:5(one cement and five sand) 12mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed by the Engineer incharge.
Ceiling Plastering for RCC slab and beams in CM 1:3 - 10 mm thick including hacking and curing etc complete.
Granolithic Flooring 25 mm thick with cement concrete 1:2:4 using 3 to 10 mm chips and top surface rendered smooth with cement including thread lining curing etc. complete
White wasing one coat over new surface with approved quality of lime including cost of cleaning surface thoroughly scaffolding and taxes etc. all complete as per specification and direction of Engineer
Colour washing two coats with approved colour and quality over two coats of white washing for outside including the cost of materials, labour charges, cleaning and preparation of the surface and curing etc., complete and as directed by the Engineer incharge.
Painting the Grill works
Supplying,fabricating and fixing of MS Grill gate in front side(3 mx 1.50) two sleeves including all costs for fixing etc.complete-490 kg
Painting two coats of newly plastered wall surface with ready mixed Cement paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification.
Labour charges for Painting Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables, one coat of base paint, scaffolding charges including painting NRDWP Logo on the Service Reservoirs.
Providing Cut stone set in CM 1:3 (one cement and three sand) using well dressed cut stone supporting inlet pipe of size 0.30 x 0.30 x 0.15m for service reservoir etc., complete as per standard specifications and as directed by Engineer-in-charge
Providing and fixing RCC inside access ladder of approved pattern and design in RCC 1:1.5:3 design mix of ISS gauge 0.40m width, 0.10m thickness, 0.12m breadth for side post, 0.05m thickness 0.12m breadth for steps with suitable inclination including cost of cement, reinforcement centering, finishing, curing etc., complete and as directed by TWAD Board Officers.
Supply,delivery and fixing in position of CI Manhole frame with cover of size 0.60m x 0.60 (heavy duty) etc.complete and as directed by Department Board Officers.
Supply and fixing in position ventilator of reinforcement cement concrete RCC M20 design mix 50 CM wide/diametre of approved pattern and design including cost of cement, reinforcement centering, shuttering, strutting, curing and fixing in position on the roof slab with mosquito proof net arrangement etc., complete. and as directed by the TWAD Board Officers.
Providing pipe connection by lifting pipes and specials in vertical direction and placing the same for required alignment including lifting the pipes and specials in various heights of inlet, outlet, overflow and scour including earthwork excavation conveying the pipe and specials into the trenches, laying to proper grade and alignment cutting, threading and jointing with jointing materials with required specification including labour charges and supply of valves pipes, specials MS Clamps to fix the pipes with the columns including all taxes duties and connected charges etc. complete and taxes duties and connected charges etc. complete and as directed by Engineer in charge. 2.00 LL
Providing pipe connection by lifting pipes and specials in vertical direction and placing the same for required alignment including lifting the pipes and specials in various heights of inlet, outlet, overflow and scour including earthwork excavation conveying the pipe and specials into the trenches, laying to proper grade and alignment cutting, threading and jointing with jointing materials with required specification including labour charges and supply of valves pipes, specials MS Clamps to fix the pipes with the columns including all taxes duties and connected charges etc. complete and taxes duties and connected charges etc. complete and as directed by Engineer in charge. 5.00 LL
Providing pipe connection by lifting pipes and specials in vertical direction and placing the same for required alignment including lifting the pipes and specials in various heights of inlet, outlet, overflow and scour including earthwork excavation conveying the pipe and specials into the trenches, laying to proper grade and alignment cutting, threading and jointing with jointing materials with required specification including labour charges and supply of valves pipes, specials MS Clamps to fix the pipes with the columns including all taxes duties and connected charges etc. complete and taxes duties and connected charges etc. complete and as directed by Engineer in charge. 7.00 LL
a) Construction of RCC Spiral stair case in RCC M20 design mix concrete of 2.30m dia of required height for approach to the roof of Service Reservoir with RCC hand rails as per type design No.Sanitary Engineer/PH(M) NO.18/64 - 65 Sanitary Engineer(PH) 3/64 including necessary earth work excavation in various classification of soils met with at the site of work for providing foundation concrete in CC 1:4:8 mix, RCC footing M30 mix, GL platform etc., including cost of steel reinforcement, fabrication charges, scaffolding, centering precasting charges, cement painting the surfaces etc.,complete and as directed by the TWAD Board Officers. The staircase shall be braced to the column of Service Reservoir at suitable interval 2.00LL
a) Construction of RCC Spiral stair case in RCC M20 design mix concrete of 2.30m dia of required height for approach to the roof of Service Reservoir with RCC hand rails as per type design No.Sanitary Engineer/PH(M) NO.18/64 - 65 Sanitary Engineer(PH) 3/64 including necessary earth work excavation in various classification of soils met with at the site of work for providing foundation concrete in CC 1:4:8 mix, RCC footing M30 mix, GL platform etc., including cost of steel reinforcement, fabrication charges, scaffolding, centering precasting charges, cement painting the surfaces etc.,complete and as directed by the TWAD Board Officers. The staircase shall be braced to the column of Service Reservoir at suitable interval 5.00 LL
a) Construction of RCC Spiral stair case in RCC M20 design mix concrete of 2.30m dia of required height for approach to the roof of Service Reservoir with RCC hand rails as per type design No.Sanitary Engineer/PH(M) NO.18/64 - 65 Sanitary Engineer(PH) 3/64 including necessary earth work excavation in various classification of soils met with at the site of work for providing foundation concrete in CC 1:4:8 mix, RCC footing M30 mix, GL platform etc., including cost of steel reinforcement, fabrication charges, scaffolding, centering precasting charges, cement painting the surfaces etc.,complete and as directed by the TWAD Board Officers. The staircase shall be braced to the column of Service Reservoir at suitable interval 7.00 LL
Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Disposal of surplus earth including loading & unloading, conveyance within a distance of 3 Km and spreading as directed by the Engineer-In-Charge.
Supply and fixing of M20 design mix RCC hand rails of 0.9 m height over the top of the roof slab of approved pattern and design including the cost of cement, reinforcement, centering, precasting, finishing, curing cement painting the surfaces etc., complete and as directed by the TWAD Board Officers. 2.00LL
Supply and fixing of M20 design mix RCC hand rails of 0.9 m height over the top of the roof slab of approved pattern and design including the cost of cement, reinforcement, centering, precasting, finishing, curing cement painting the surfaces etc., complete and as directed by the TWAD Board Officers. 5.00LL
Supply and fixing of M20 design mix RCC hand rails of 0.9 m height over the top of the roof slab of approved pattern and design including the cost of cement, reinforcement, centering, precasting, finishing, curing cement painting the surfaces etc., complete and as directed by the TWAD Board Officers. 7.00LL
Supply, delivery and fixing in position of enamel coated "water level indicator" with all accessories of approved pattern and design, in the outer surface of the side wall of Sump to read the water level of the required height and as directed by TWAD Board Officers.
Description of Work / Item(s)
Amount
Total cost of operation and maintenanceof the distribution system including manpower, spares, consumables, repair and maintenance work, preventive maintenance, etc. For First Year
Total cost of operation and maintenanceof the distribution system including manpower, spares, consumables, repair and maintenance work, preventive maintenance, etc. For Second Year
Total cost of operation and maintenanceof the distribution system including manpower, spares, consumables, repair and maintenance work, preventive maintenance, etc. For Third Year
Total cost of operation and maintenanceof the distribution system including manpower, spares, consumables, repair and maintenance work, preventive maintenance, etc. For Fourth Year
Total cost of operation and maintenanceof the distribution system including manpower, spares, consumables, repair and maintenance work, preventive maintenance, etc. For Fifth Year
Description of Work / Item(s)
Amount
Organize meetings with line departments.
Workshop on E&S safeguards and on-job training as identified.
Use of IEC material and use of media channel to create public awareness on waste management
Consultations with stakeholders regularly
Meetings of GRC
Air quality monitoring
Surface water quality monitoring
Ground water quality monitoring
Soil quality monitoring
Noise quality monitoring
Wind speed and direction
Tree Plantation/ Greenbelt Development at project sites
RPP INFRA PROJECTS LIMITED (BID ID -1013351)
RPP INFRA PROJECTS LIMITED (BID ID -1013351)
RPP INFRA PROJECTS LIMITED (BID ID -1013351)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid