| Sl No | Description | Qty | Unit | BRITE INDUSTRIES L4 | Indepth solutions L3 | Patson Technological Solutions Pvt. Ltd. L1 | V S Engineering L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | VRF Outdoor Units:
Supply, Installation, testing and commissioning of Modulating outdoor units, with multi scroll compressors having Invertor Based Compressor based on Unit Configuration.
The Unit should have, Condenser fan, Electrical Accesories & Microprocessor Based Control panel, isolating valves, and all the necessary accessories for proper functioning of the Condensing units along with respective indoor units.
Unit shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply. Each outdoor unit shall be provided with its own isolator with required accessories. Required power cabling.
The unit to be shipped with full charge of Refrigerant and oil, refrigeration-piping controls etc.
The unit should comply with Min C.O.P of 3.5.
The Refrigerant used shall be CFC free gas either R407C/ R410A.
Make: TRANE/ Mitsubishi/ Hisense
VRF ODU: 18 HP | 1 | Nos. | 5,42,087 ₹5,42,087 | 4,15,000 ₹4,15,000 Lowest | 4,29,990 ₹4,29,990 | 4,50,000 ₹4,50,000 |
| 2.00VRF Indoor Units: Supply, testing and Commissioning of variable refrigerant flow modular type indoor units with wired/wireless remote suitable for R410a refrigerant comprising of all accessories as per the specifications. The indoor units shall be suitable to work on cooling mode. Unit shall be include with three step speed control regulator, tubular type centrifugal fan, electronic expansion valave, anti bacterial treatment & decorative panel with dirt replent coating &Unit shall be include with three step speed control regulator. The minimum Energy Efficiency Ratio shall be as per ASHRAE STANDARDS 90.1 -2001 table 6.2.1B. The indoor units shall be suitable for operation on 220 ±10% volts, 50Hz, 1 phase AC power supply with. dx ductable. Units capacity shall be selected based on actual return air & fresh air conditions with deration factors as applicable by OEM & refrigerant piping length losses. The indoor unit shall be complete with pre filter, remote controls, Drain hose, Metal clamp, Washer for hanger bracket, rod, anchor fastener, Clamp, Paper pattern Screw, Washer, fixing plate, Insulation for fitting Sealing pad, for installation as per requirement The indoor units shall be of following capacities: Make: TRANE/ Mitsubishi/ Hisense | |||||||
| 2.01 | 3 TR 4 Way Cassette Unit | 2 | Nos. | 50,098 ₹1,00,196 | 48,500 ₹97,000 | 44,772 ₹89,544 Lowest | 50,000 ₹1,00,000 |
| 2.02 | 2 TR 4 Way Cassette Unit | 2 | Nos. | 41,994 ₹83,988 | 41,500 ₹83,000 | 37,355 ₹74,710 Lowest | 40,000 ₹80,000 |
| 2.03 | 1 TR 4 Way Cassette Unit | 4 | Nos. | 34,252 ₹1,37,008 | 39,250 ₹1,57,000 | 30,269 ₹1,21,076 Lowest | 35,000 ₹1,40,000 |
| 3.00 | Supply, Installation, Testing & Commissioning of Treated Fresh Air of 600 CFM. SISW Direct Drive Plug
SP (mm wg) for Blower : 25mm, DX Type.
Make: Edgetech | 1 | Nos. | 97,701.8 ₹97,701.8 Lowest | 2,15,000 ₹2,15,000 | 1,49,900 ₹1,49,900 | 2,25,000 ₹2,25,000 |
| 4.00Installation, testing and commissioning of Modulating outdoor units, with multi scroll compressors having Invertor Based Compressor based on Unit Configuration. The Unit should have, Condenser fan, Electrical Accesories & Microprocessor Based Control panel, isolating valves, and all the necessary accessories for proper functioning of the Condensing units along with respective indoor units. Unit shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply. Each outdoor unit shall be provided with its own isolator with required accessories. Required power cabling. The unit to be shipped with full charge of Refrigerant and oil, refrigeration-piping controls etc. The unit should comply with Min C.O.P of 3.5. The Refrigerant used shall be CFC free gas either R407C/ R410A | |||||||
| 4.01 | Installation, Testing & Commissioning Of VRF Outdoor Unit With N2 Testing, Vaccumising & Testing (18 HP) | 1 | Nos. | 54,000 ₹54,000 | 38,500 ₹38,500 Lowest | 41,000 ₹41,000 | 40,000 ₹40,000 |
| 4.02 | Installation, Testing & Commissioning Of VRF Indoor Unit 4 Way Cassette (3TR) | 2 | Nos. | 3,000 ₹6,000 | 5,400 ₹10,800 | 5,500 ₹11,000 | 1,500 ₹3,000 Lowest |
| 4.03 | Installation, Testing & Commissioning Of VRF Indoor Unit 4 Way Cassette (2TR) | 2 | Nos. | 3,000 ₹6,000 | 5,400 ₹10,800 | 5,000 ₹10,000 | 1,500 ₹3,000 Lowest |
Tender Value
₹15.9 L
EMD Value
₹31,760
Closing Date
25 Apr 2026, 6:55 pmClosed
OIC, Engineering, TMC on behalf of Director, TMC
Engineering Department, 6th Floor, Service Block, TMH, Parel
Proposed HVAC Renovation work of staff clinic and HRD office at 2nd floor of Service Block Bldg, TMH
2026_TMC_905021_1
TMC/ENG/HVAC/HRD/2026 27/01
Open Tender
Machineries/ Mechanical Engg Items
Works
60 days
TMH, Parel
As per tender documents
5 documents required · 5 mandatory
₹0
₹31,760
TMH, Parel
17 Jun 2026
9 Apr 2026
27 Apr 2026
9 Apr 2026
25 Apr 2026
17 Apr 2026
9 Apr 2026 - 14 Apr 2026
15 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1VRF Outdoor Units: Supply, Installation, testing and commissioning of Modulating outdoor units, with multi scroll compressors having Invertor Based Compressor based on Unit Configuration. The Unit should have, Condenser fan, Electrical Accesories & Microprocessor Based Control panel, isolating valves, and all the necessary accessories for proper functioning of the Condensing units along with respective indoor units. Unit shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply. Each outdoor unit shall be provided with its own isolator with required accessories. Required power cabling. The unit to be shipped with full charge of Refrigerant and oil, refrigeration-piping controls etc. The unit should comply with Min C.O.P of 3.5. The Refrigerant used shall be CFC free gas either R407C/ R410A. Make: TRANE/ Mitsubishi/ Hisense VRF ODU: 18 HP | |||||
| 2VRF Indoor Units: Supply, testing and Commissioning of variable refrigerant flow modular type indoor units with wired/wireless remote suitable for R410a refrigerant comprising of all accessories as per the specifications. The indoor units shall be suitable to work on cooling mode. Unit shall be include with three step speed control regulator, tubular type centrifugal fan, electronic expansion valave, anti bacterial treatment & decorative panel with dirt replent coating &Unit shall be include with three step speed control regulator. The minimum Energy Efficiency Ratio shall be as per ASHRAE STANDARDS 90.1 -2001 table 6.2.1B. The indoor units shall be suitable for operation on 220 ±10% volts, 50Hz, 1 phase AC power supply with. dx ductable. Units capacity shall be selected based on actual return air & fresh air conditions with deration factors as applicable by OEM & refrigerant piping length losses. The indoor unit shall be complete with pre filter, remote controls, Drain hose, Metal clamp, Washer for hanger bracket, rod, anchor fastener, Clamp, Paper pattern Screw, Washer, fixing plate, Insulation for fitting Sealing pad, for installation as per requirement The indoor units shall be of following capacities: Make: TRANE/ Mitsubishi/ Hisense | |||||
| 2.01 | 3 TR 4 Way Cassette Unit | - | Nos. | - | - |
| 2.02 | 2 TR 4 Way Cassette Unit | - | Nos. | - | - |
| 2.03 | 1 TR 4 Way Cassette Unit | - | Nos. | - | - |
| 3Supply, Installation, Testing & Commissioning of Treated Fresh Air of 600 CFM. SISW Direct Drive Plug SP (mm wg) for Blower : 25mm, DX Type. Make: Edgetech | |||||
| 4Installation, testing and commissioning of Modulating outdoor units, with multi scroll compressors having Invertor Based Compressor based on Unit Configuration. The Unit should have, Condenser fan, Electrical Accesories & Microprocessor Based Control panel, isolating valves, and all the necessary accessories for proper functioning of the Condensing units along with respective indoor units. Unit shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase AC supply. Each outdoor unit shall be provided with its own isolator with required accessories. Required power cabling. The unit to be shipped with full charge of Refrigerant and oil, refrigeration-piping controls etc. The unit should comply with Min C.O.P of 3.5. The Refrigerant used shall be CFC free gas either R407C/ R410A | |||||
| 4.01 | Installation, Testing & Commissioning Of VRF Outdoor Unit With N2 Testing, Vaccumising & Testing (18 HP) | - | Nos. | - | - |
| 4.02 | Installation, Testing & Commissioning Of VRF Indoor Unit 4 Way Cassette (3TR) | - | Nos. | - | - |
| 4.03 | Installation, Testing & Commissioning Of VRF Indoor Unit 4 Way Cassette (2TR) | - | Nos. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.84 MB
techdocumentchecklist.xls
Tender Documents • 0.03 MB
BOQ_951260.xls
BOQ • 0.26 MB
corrigendum01.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].