Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 LAccepted-AOC | ₹6.7 L Quoted ₹6.8 L | 1 | Accepted-AOC The quoted price are lower than other bidders |
| 2 | 1₹8.3 LAccepted-AOC 27A 3RD CROSS 14TH LINK ROAD NEHRU NAGAR INDUSTRIAL ESTATE KOTTIVAKKAM CHENNAI 600 041 | CHENNAI | CHENNAI | TAMIL NADU | 600041 | ₹8.3 L | 1 | Accepted-AOC The quoted price are lower than other bidders |
| 3 | 2₹7.0 LRejected-Finance C 2 290 RUSSELL TECHNOLOGIES C 2 290 SECTOR F JANKIPURAM 226021 U P JANKIPURAM LUCKNOW UTTAR PRADESH 226021 | LUCKNOW | UTTAR PRADESH | 226021 | ₹7.0 L | 2 | Rejected-Finance The quoted price are higher than qulaitech |
| 4 | 2₹12.9 LRejected-Finance | ₹12.9 L | 2 | Rejected-Finance The quoted price are higher than VB Ceramic limited |
| 5 | 3₹7.7 LRejected-Finance SOUTH PHASE 100A AMBATTURINDUSTRIALESTATE AMBATTUR INDUSTRIAL ESTATE CHENNAI TAMILNADU 600058 | CHENNAI | TAMIL NADU | 600058 | ₹7.7 L | 3 | Rejected-Finance The quoted price are higher than qulaitech |
Tender Value
₹14 L
EMD Value
₹42,000
Closing Date
30 Sept 2020, 6:00 pmClosed
Dr Amit Bansal
Mechanical Department IKGPTU
Supply Installation Commissioning Maintenance of Laboratory Instruments for Department of Mechanical Engineering I K Gujral Punjab Technical University Main Campus Kapurthala Punjab
2020_DTE_52054_1
IKGPTU/MC/2020-21/023
Open Tender
Mechanical Tools and Equipment
Item Wise
45 days
Kapurthala
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
TIA
₹42,000
Yes
IKGPTU Kapurthala
8 Feb 2021
17 Aug 2020
5 Oct 2020
17 Aug 2020
30 Sept 2020
7 Sept 2020
31 Aug 2020
Mechnical Engineering Laboratory
Digital Micro Vicker Hardness Tester: Specifications: Testing Force: 10g (0.098N), 25g (0.245N), 50g (0.49N), 100g (0.98N), 200g (1.96N), 300g (2.94N), 500g (4.9N), 1000g (9.8N). Scale: HV0.01、HV0.025、HV0.05、HV0.1、HV0.2、HV0.3、HV0.5、HV1 Min. Measuring Unit: 0.01μm Hardness Value Rang: 8HV-2900HV Hardness Value of Reading: 8 inch Digital Touch Screen Hardness Conversion: HRA, HRB, HRC, HBW, HRD, HRF, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HK. Total Magnification of Microscope: 100X(For Observation)、400X(For Measurement) Loading Method: Automatically(Load, dwell and unload the testing force) Duration Time: 1-99s Switch Type of Objective lens and Indenter: Auto Turret Specimen Allowing Maximum Height: 100mm Throat Depth: 130mm Overall Dimension: 540*190*595mm or better Net Weight: Approximately 50Kg Light Source: LED Cold light source (can be continuous use for 24 hours, no heat generated, servicing life can reach 100,000 hours) Power Supply: 110V/220V + 5%, 50/60 Hz Digital X-Y Testing Table: Dim.:100×100 mm, Max. Travel Range: 25×25mm, Moving Resolution Ratio:0.001mm (Digtal XY micrometer). Executed Standard: GB/T4340, ASTM E384 & E92, EN-ISO 6507, JIS B-7734 Standard Accessories: 1 piece: 10X digital micro eyepiece; 10X and 40X objective lens; Vickers indenter; Digital X-Y Testing Table; Power line; Dust cover; Instruction Book; Hardness Conversion Tables; Accessory case; 2 pieces: Standard block of hardness; 4 pieces: horizontal adjusting screw The most advanced High transmission ratio high precision worm gear rod, can achieve stable continuous lifting of XY table. Camera & Auto Measurement Software: Inbuilt USB camera with Auto measurement and manual function software. Auto report generation with case depth graph. PC, UPS: PC with i3 or better Processor, 2 to 4 GB RAM, ITB-HDD, USB, Serial Port, Optical mouse, Keyboard, 19” LED Monitor, Preloaded with Window XP or better. UPS: Suitable online UPS with 20-30 minutes backup Warranty: 3 Years Comprehensive warranty followed by 2 years AMC Except computer and UPS, all components should be from original Equipment Manufacturer
Microwave furnace : Specifications: FURNACE STRUCTURE 1. Furnace outer Shell: 500 x 500 x 1200 mm 2. Shell Construction: High quality fabrication of M.S.Body and M.S. Angle’s structure with proper stiffeners and neat powder coat painting and main chamber made out of Stainless steel (316 grade) 3. Furnace panel box : Control panel box coupled with furnace bottom 4. Insulation : Insulation board imported from Zircar, USA 5. Number of susceptor : Ten numbers 6. SS Chamber size : 300 x 300 x 300 mm 6. Susceptor cavity size : 75 x 75 x 75 mm 7. Size of the sample : Less than 50 mm in all dimensions (maximum) HEATING SYSTEM 1. Heating system :Microwave by magnetron 2. Power rating : 2.45GHz with 1.1KW each x 4 numbers 3. Operation : Single phase / AC 4. Power out put : two magnetrons with total 2.2Kw x 2 set (one set sill work at time and using timer automatically shifted to another set for continuous operation) 5. Maximum temperature : 1600C (Max) 6 Normal working temp : 1500C 7. Rate of heating : 10 to 25C/ minute (Max) (programmable) CONTROL SYSTEM: 1. Temperature control : Eurotherm (Model 3216) Micro processor based PID programmer cum Digit Temperature Indicator 2. Temperature sensor : Imported non contact infrared sensor 3. Temperature accuracy : ±1C at soaking 4. Control switches : Mains on, out put on 5. Safety : Input, out put fuses Note: Quartz Chamber with control atmosphere suitable for 20mm Dia sample (Extra attachment) along with consumable kit for performing the experiment.
RUSSELL TECHNOLOGIES INDIA PVT. LTD.
VB CERAMIC CONSULTANTS
Chennai Metco PVT LTD
Ashian Engineers Company India
Radical Scientific Equipments Pvt Ltd
Medilab Enterprises
Qualitech Systems
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .