EXECUTIVE ENGINEER
Room no 602 BSNL Bhavan Adarsh Nagar Hyderabad
Replacement of Accessories for DTR, Repair of meter panels, laying of cables, EI and Fans and Pump set repairs at Staff Quarters compound Tirumalgiri.
2024_BSNL_199265_1
09/BEDH-II/2024-25 Dated 24-06-2024
Open Tender
Electrical Works
Item Rate
30 days
HYDERABAD
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO CASH MAIN BSNL HYDERABAD
₹11,156
2 Jul 2024
24 Jun 2024
1 Jul 2024
24 Jun 2024
29 Jun 2024
24 Jun 2024
Amount
SH-I: DTR misc items Supplying and fixing of the following electrical Spares for the existing DTR including interconnections, testing etc., as required. (a) HG fuse set
(b) AB switch along with connecting pipe, handle
(c) Kit Kat Fuse for distribution of LT power supply in a suitable MS box
(d) Providing Earthing with G.I. earth plate of 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
(e) Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
(f) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
SH-II: EI Fans Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(b) 2 X 6 sq. mm + 1 X 2.5 sq. mm earth wire
(c) 4 X 6 sq. mm + 2 X 2.5 sq. mm earth wire
Providing repairs to Electrical Installation / point wiring / circuit wiring / power plug wiring etc., by replacing the following accessories i/c removing of faulty items, including interconnections, etc., as required. (a) 20 W LED fittings
(b) 2Way 5 A Switches
(c) 6A - 32 A SP MCBs
(d) 32A SPN Isolators (inside the panel)
(e) PVC angle holders
SH-III: Cable Supplying of 3 ½ x 35 sq. mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade etc., as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, protective covering and refilling the trench etc as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Supplying and laying of 40mm dia GI pipe of medium class by cutting CC road including making good the same after installation of GI pipe etc., as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3½ X 35 sq. mm (32mm)
SH-IV: Energy meter panel Cleaning the existing energy meter panel by removing the faulty / broken hylam sheets / clearing the mud / debris from the panel etc., as required
Providing wiring with 6 sq mm copper wire / lugs for the single phase energy meter / Bus bar / double pole isolators inside the energy meter panel by removing the old faulty wiring inlcuding replacing minor spares inside the panel etc., as required.
Providing repairs to the energy meter panel by replacing the faulty / missing hinges / enegy meter glass covers / panel covers / nuts & bolts / din channels / broken bus bars / hylam sheets etc., as required.
Providing painting to the existing energy meter panel by removing rust / dust with emry paper with engineer in charge approved colour etc., as required
SH-V: Pumpset Supplying, Installing, Testing and Commissioning of following rating mono submersible type pump, suitable for operation on 3 phase, 415volts, 50Hz AC supply etc., as required (a) 3HP, 3 phase. M/s Kirloskar JOS-335
Supplying and fixing of the following accessories etc.,as required. (a) 40mm dia CPVC pipe
40mm dia brass NRV
40mm dia CPVC MABT
40mm dia CPVC Bend
40mm dia CPVC Union
25mm dia CPVC ball valve
40/25mm dia CPVC 'T'
40 mm dia CPVC coupling
Supplying and fixing of electronic starter with controls viz., time delay, dry run protection, overload relay, MCB, display of voltage and current etc, suitable for following rating motors etc, as required. (make: GELCO DCP 3.4 DAF / OCLEG / SS) (a) 3HP, 3phase.
Supplying and Laying of 3C 2.5 sq mm Flat submercible Pump copper Conductor cable etc. as required.
SH-VI: Compound Lights Providing repairs to compound lights by replacing the following accessories i/c removing of faulty, including interconnections etc., as required. (a) 30W LED street light fitting (Make: CG / SS)
Supplying and laying of 2 core 6 sq.mm, PVC sheathed PVC insulated weather proof service wire, along with earth wire 14 SWG GI wire from fitting to timer etc., as required
weather proof pole box along with 6A connector and 6A SP MCB (Make: syntex or SS)
Supplying and fixing of 25mm dia GI bracket, of length 1.0mtrs bent at suitable angle for mounting the LED type fitting including fixing the bracket on the surface of wall, etc as required.
Supplying and fixing of 3 kW Timer for switch "ON" & "OFF" of the compound lighting (2 circuits) i/c interconnections, testing etc., as required.
P KISHAN RAO
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .