Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹6.1 L
EMD Value
₹12,170
Closing Date
17 Oct 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer MU.
MU Canchipur
Construction of RO (Drinking Water) Plant station at MU Campus, Manipur University.
2024_MU_830091_1
MU/8(47)/2023-UE/827
Open Tender
Civil Works
Works
60 days
As Per Tender Document
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
The Register MU.
₹12,170
MU Canchipur
18 Oct 2024
9 Oct 2024
18 Oct 2024
9 Oct 2024
17 Oct 2024
9 Oct 2024
16 Oct 2024
Amount
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres Loose/Soft Soil
Filling in plinth with sandy soil under floors including watering ramming, consolidating and dressing complete.
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering
a) 1:4:8(1 cement : 4 coarse sand :8 graded stone aggregate 40 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up to floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Reinforcement for R.C.C. work i/c bending ,binding and placing complete. Tor Steel
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement: 4 coarse sand)
Half brick masonry 2nd class (local 1st class) in cement mortar 1:4 (1 cement: 4 coarse sand) in superstructure.
Steel work welded in built up sections, framed work in cutting, hoisting, fitting in position & priming coat of red lead paint . In gratings, framed guard bars, ladders, railings, brackets and similar works.
Supplying and fixing welded steel wire fabric to wood or steel members in partition etc. a) Weight exceeding 2 kg/sqm but not exceeding 3 kg/sqm
12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
Painting (two or more coats) with synthetic enamel paint of approved quality of black or chocolate colour on wood work to give an even shade.
Distempering (two or more coats) with oil bound washable distemper of approved quality on new work i/c priming coat to give an even shade.
White glazed tiles 10 mm in flooring, treads or steps & landing laid on a bed of 12 mm thick cement mortar 1:3 (1 cement:3 coarse sand) finished with flush pointing in white cement.
Providing and fixing Water Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. 1000 litres net capacity storage tanks
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes
Th. Jeevan Singh
M/S Y SOMORJIT SINGH
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .