Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-Finance | ₹31.0 L | L1 | Accepted-Finance Responsive |
| 2 | L2₹31.6 LAccepted-Finance | ₹31.6 L | L2 | Accepted-Finance Responsive |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹57.8 L
EMD Value
₹1.2 L
Closing Date
5 Mar 2026, 6:55 pmClosed
Executive Engineer
Shalimar
Internal/External Electrification Works, CCTV, Diversion of 11 KV line etc for Establishment of DNA Finger printing, Seed Testing and Food Processing Training Centre (CAPEX) at Main Campus Shalimar, SKUAST-Kashmir.
2026_SKUST_304677_1
E-NIT-97 of 2025-26
Open Tender
Electrical Works
180 days
main campus shalimar, SKUAST-K
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,500
Assistant comptroller
₹1.2 L
10 Apr 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
5 Mar 2026
27 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Group B
Group C
Wiring for Light / Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/ Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire 3 Phase wiring
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supply,Installation,Testing and Commissioning ing and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.
25mm PVC Conduit
40 mm PVC Conduit
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, Unit connections etc. as required
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supply,Installation,Testing and Commissioning and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200-300 A tinned copper bus bar, common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer ) as required . (for Three phase supply distribution suitable for 3 pole & 4 pole DU250, DU250C & DN1 MCCB as incomer
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5-32A Single Pole
16-32 Amps - DP
63 Amps MCB DP
Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32 A F.P MCB 10 Ka "C" Curve
63 A F.P MCB 10 Ka "C" Curve
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required.
200 A,36KA,FPMCCB
S/I of high bay light 150 Watt LED Cool White , with 2 year warrranty . Complete in mountage and installation works. Preferable Make Havells /Philips /Sysyka /Equivalent
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). 50Watt
Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser andconstruction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard
Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. Make USHA /CG/Havells/
1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supply,Installation,Testing and Commissioning ing and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin)
SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 36 WATT
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 metre lonQ etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.l strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G. I. nut bolt & spring washer spaced at 50mml
Supply,Installation,Testing and Commissioning of AC 230/250 Volts, 50 Hz exhaust fan with louveres of Following Sizes including connection etc. complete as required .
Supply and laying of folowing size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground 75mm below level including excavation and refilling the trench but excluding sand cushioning and protective covering etc , complete as required.
63 mm dia nominal)
90 mm dia nominal)
Supplying and fixing 25 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 32A A C" curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 240 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 32A A C" curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
Supply,Installation,Testing and Commissioning ing and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.
3.5 C X 50 Sq.mm A2XFY armoured
3.5 C X 185 Sq.mm A2XFY armoured
Supply,Installation,Testing and Commissioning and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)
3½ X 150 sq. mm (45mm)
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
1 run of cable
2 run of cable
Supply,Installation,Testing and Commissioning , Installation, Testing and Commissioning of Semi managed 16 port POE , complete as per specification and as desired by EIC.
Supply,Installation,Testing and Commissioning & Erection of lockable 9/12 U rack Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm.
Supply,Installation,Testing and Commissioning & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC.
S/ I of geyser 50 Ltr 5 Star Make Jaguar /Havells/Venus/ Jupiton Equivalent
Supplying and fixing recess of USB Charger socket
LED Tubelight Batten 300mm / Warm White / 18-22W
FIRE DETECTION & ALARM SYSTEM
Two Loop Panel.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator adressable complete with base as required
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying & laying of 3x1.5 sqmm fire survival unarmoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, complete as required.
Supply, Installation, Testing & Commissioning of Indoor Dome Camera IP CCTV Monitoring, Recording & Streaming Systemas per the Following Specifications:- Minimum 5 megapixel progressive scan HD CMOS with SD Card Feature.Lens :- 3-6 mm or Better , DC‐Iris/Auto Iris Field of view:-100˚to 45˚ (horizontal) 72-34 ° (vertical) Day/night operation:-The camera should provide day/night functionality automatically switches to night mode in low‐light scenes Wide dynamic range:- True WDR 100dB or equivalent or better Minimum illumination /light sensitivity :- Color mode: @0.2 lux black and white mode: @0.03 lux Video compression:- H.265 motion JPEG Resolutions and frame rates (H.265):- At 2304x1728, the frame rate shall be 30 FPS or better for viewing. All the streams shall be user configurable (with respect to resolution, frame rate & compression standard). All the cameras (sensors) shall have minimum 5 streams. PoE:- It should be PoE enabled and with IK08 enclosure and in built 20m IR Certification:- It should be FCC, CE, UL certified ONVIF:- ONVIF 2.0 Support Supported protocol:- DHCP, HTTP, HTTPS, NTP, RTP, RTSP, SMTP, SSL/TLS,TCP/IP, Secure Real Time Transport Protocol (SRTP) Bonjour, SNMP, and Secure Shell (SSH)
Supply & Erection of Cat-6, 3Mtr Patch Cords complete as per specification and as desired by EIC.
Supplying and drawing of 12 Pair Single Mode Optical Fibre Cables in the existing surface/ recessed Steel/ PVC conduit as required.
Supply & Erection of Media Convertor complete as per specification and as desired by EIC.
Supply & Erection of Termination Box complete as per specification and as desired by EIC.
Supply & Erection of CAT 6, 16 port Jack panel for termination of CAT6 cable,Testing & certification of the network with Omni/Penta Scanner of each Cable.
Supply, installation, testing and commissioning of Junction Boxes/DB-20 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC
Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC.
Supplying,Installation,Testing and Commissioning of 55 Inches Ultra H.D LED Display Monitor as per the Specifications attached.
Supplying of 16 Channel Network Video Recoder(NVR) as per the Specifications Enclosed with a Hard Disk Memory of 4 TB Capacity.
Supply, Installation, Testing and Commissioning of 10/100/1000 Mbps Unmanaged Switches with Provision of 16 10/100/1000 Mbps ports as per specification and as desired by the Engineer Incharge.
Supply of Dell/ HP Inspiron 3530 Laptop, 13th Generation Intel Core i7-1355U Processor, 16GB, 512GB, 15.6"
Supplying and fixing of CO2 type fire extinguisher ISI marked confirming to IS: 15683 capacity 4.5 Kg complete with delivery hose horn, squeeze grip release valve , locking arrangement, operation manual, bracket with two screw and sleeve including transportation cartage upto various post in Kashmir region of SIB as per Anexure attached etc complete as required. (Make : Life Guard/Minimax/Safeguard)
Providing and fixing ABC type (Dry Power Type ) Extinguisher as per IS: 15683 consisting of welded MS cylindrical body, with discharge hose, discharge valve, suspension bracket, initial filling, pressure gauge including transportation cartage upto various post in Kashmir region of SIB as per Anexureattached.etc complete as required. (Make : Life Guard/Minimax/Safeguard)
a) Capacity 6 Kg.
Supply,Installation,Testing and Commissioninging of LT Panel Enclosure made out of 2mm thick CRC sheet duly powder coated with Stand 12"(h) comprising of: Incomers:L&T /Legrand Make MCCB 250 A 4P 36kA HID Frame with Spreader Links - 1No. Busbar 600A TPN Alm. -1Set Metering: Digital VAF, PF meter Class 1.0 with CT's and RYB Lamps -1Set Outgoings: MCCB 125A 4P 27kA HID Frame with Spreader Links - 4 No. MCCB 63A 4P 27kA HID Frame with Spreader Links - 1No. Panel Shall have Space for 12 Modules of MCB Wiring and Other Panel Accessories -As Required
11 KV Part
Supply of Steel tabular poles as per 410 SP 33 with base plate of size 1.5’x1.5’ x 8 mm with GI rod for earthing , painting , Earthing rod and spirla earthing etc .
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Above 8.0 metre and upto 10.0 metre
Supply , laying and erection of ACSR Rabbit conductor 0.05 with jumpering and termination works.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps,bolts and nuts including drilling holes for insulator pins, bolts, F-top,nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
S/I of GI Ch iron 75x40x6mm x 8 ft with nuts bolts and clamps
S/l of Guy with turn buckler and Guy insulator etc, 8 SWg twisted GI wire laid in cement concrete . Complete job in all respects.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required Set of 3 pieces with fittings and nuts and bolts.
11 kV link set Heavy duty complete with all accessories ISI standard Heavy duty 600 Amp
Supply, carriage, loading, un-loadign installation, testing, commissioning etc. of Danger Plates with clamps
Supply, carriage, loading, un-loadign installation, testing, commissioning etc. of GI Barbed Wire for Anti Climbing
Supply, carriage, loading, un-loadign installation, testing, commissioning etc of Painting of Poles Red Oxide
Supply, carriage, loading, un-loadign installation, testing, commissioning etc. of Painting of Poles Aluminium Paint
Supply, carriage, loading, un-loadign installation, testing, commissioning of Sundry items like aluminium lugs, Thimbles, Jumpers, binding Tape
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
S/I of detachable 11 KV link rod Polymer ISI
Street lighting Part
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surgeprotection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,
CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)
100 Watt Make Philips /Havells/Wipro/Avavaya Warranty 2 years On site replacement with auto on /off night sensor and dimmable 50 %
P/L of 4 MM round copper cable multi stranded 3 core cable Make Havells/ Gloster/ Finolex/ Khaitan /Equivalent
Providing & fixing of Hot dip galvanized octagonal pole 8 mtr long with following dimensions :Length of pole 08 mtrs.Bottom Dia 150 MM Top dia. 76 MM Sheet thickness : 3 MM With base plate 240 x 240 x 16mm Bolt size = 20 MM x 600 MM x 4 No’s Make Philips/Bajaj/Equivalent
P/f of detachable type single arm bracket fabricated out of 40 MM dia MS Pipe 1500MM long duly bended C curve (Hot galvanised)
P/f of MCB DP Box SSK with MCB DP 40 A Legrand with connector 40 A 4 Way with clamp nuts and bolts & washers etc
Providing fixing of concrete block M-15 mix 20mm nominal aggregate size 4 Nos. holding down bolts of size 20 MM x 600 MM x 4 No’s each bolt having 2 Nos.nuts below washers to be adjusted with plate level for hosting of octagonal pole under sight of concrete all nuts and bolts exposed to be applied with grease with block dia 1’.x9’’ 3.5 feet deep for steel pole. The finishing work includes painting with bitumen as required
P/f of 3x 1.5 Sq MM PVC Multi stranded copper wire from connection box to luminary
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm OD ID 51
NOTE:- Cost of existing conduit as laid earlier shall be deducted @ Rs 168 per meter in the subsequent running billls.
Note:- The rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site work and all extra charges including dewatering if any during the execution of work till complete in all respects.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_989708.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
BOQ_989708.xls
BOQ • 0.97 MB
Download all tender documents and submit your bid