Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.0 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹29.6 L+₹58,810.20 (2.03%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹35.4 L+₹6.4 L (21.9%)Rejected-Finance WARD NO 11 HOUSE NO 305 JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Rejected-Finance other than L-1 |
Tender Value
₹27.9 L
EMD Value
₹56,000
Closing Date
19 Mar 2022, 6:00 pmClosed
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
ADDN/ ALTN AND REPAIR OF ROOF, FALSE CEILING AND OTHER ALLIED WORKS TO BLDG NO NP-22 OF WKS EME (SIG GP) UNDER GE (SOUTH) UDHAMPUR
2022_MES_506779_1
CA NO CWE/U(S)-101/2021-22
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) UDHAMPUR
₹56,000
Yes
29 Apr 2022
9 Feb 2022
21 Mar 2022
9 Feb 2022
19 Mar 2022
7 Mar 2022
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and as directed by Engr-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and as directed by Engr-in-Charge.
Dismantling wall ceiling board ( fibre, pulp,insulation etc ) or insulation board / slab/ blankets any thickness including cover fillets, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Mild steel Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails guides for sliding doors, and vertical posts of pipes sections fixed with angle cleats or other connecting plates, Fe-410-W (Gde - E -250) complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
4mm thick Cement fibre board (designer ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including GI frame work with size of grid 605mm x 605mm including all accessories and GI suspensions, the fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Vitrified Ceramic tiles (Square/rectangle) of 10mm thick coloured (area of each tile n exceeding 0.36 sqm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 10 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
All as per serial item No. 15.00 here in before but on vertical surfaces as in skirting/dado over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Dura stone tiles of size 305 x 305 x 10mm thick as in floors and including 20mm thick screed bed or bedding layer in cement mortar 1:4, including jointed with neat cement slurry and pointed in coloured cement to match the surface of tiles, complete all as specified and directed by Engineer-in-Charge. Note : (Shade/Colour as approved by GE)
75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in plinth protection, complete all as specified and as directed by Engr-in-Charge.
Applying of one coat (1mm thick) birla wall care putty on new surfaces of walls including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading with oil greasy spot complete all as specified and as directed by Engr-in-Charge
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Applying two coat (1mm thick) wall care putty on new surfaces of walls including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading with oil greasy spot complete all as specified and as directed by Engr-in-Charge.
Applying two coats of distemper oil emulsion over a coat of primer including preparation of new plstered surfaces of wall complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of suitable primer, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 26 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and as directed by Engr-in-Charge.
Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, complete all as specified and as directed by Engr-in-Charge.
4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed by Engr-in-Charge.
3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed by Engr-in-Charge.
S&F Aluminium body heavy duty double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other part made of mild steel heavy duly and fixed repair including taking down aluminium shutter and refixing in replacement of pivat complete all as specified and as directed by Engr-in-Charge.
Powder coated (15 micron) aluminium frames for door/ windows/ ventilators of approved design with one or more rebated including jointing cleats with all fixing arrangement in repair, complete all as specified and directed by Engr-in-Charge.
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engr in Charge.
Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete, all as specified and directed by Engr in Charge.
12mm thick Prelaminated particle board, termite proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15 ) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P brass/ stainless steel screws @ 200 mm centre to centre, including cutting to grill to proper opening size of fixing and operation of handles and fixing approved anodised aluminium standard section around the opening , all complete as per requirement and directed by Engr-in-Charge.
S&F for brass mortice lock of 4 levers 100 mm thick vertical type, complete all as specified and as directed by Engr-in-Charge.
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Plain Cement concrete 1:2:4 type B-I using 20mm graded aggregated stone aggregates as in lintels upto 1.50 metre clear span,cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form works complete all as specified and as directed by Engr-in-Charge.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beam; plinth beams; bases of columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engr-in-Charge. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed by Engr-in-Charge. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engr-in-Charge. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to obtain rough finished flat surfaces of concrete complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished flat surface of concrete complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to sides and sofits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc to obtain rough finished flat surface of concrete complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed by Engr-in-Charge.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed by Engineer-in-Charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound, complete all as specified & directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 300x450mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Shingle filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering, complete all as specified and as direceted by Engr-in-Charge.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Broken stone hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge
Providing 50 mm thick cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed by Engr-in-Charge
Preparing plastered or unplastered new surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling complete all as specified & directed by Engr-in-Charge.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified & directed by Engr-in-Charge. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Factory made mild steel ventilators (box type) with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all as specified & directed by Engr-in-Charge. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
4mm thick Sheet glass, ordinary quality and glazing with oil putty in square or rectangle, area n exc 0.5 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified and as directed by Engr-in-Charge.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
150 mm aluminium handles, cast type anodised complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
Mild steel cold rolled butt hinges medium weight 100 mm long fixed to steel /angle iron frame by welding, if required complete all as specified and as directed by Engr-in-Charge.
15 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
20 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair complete all as specified.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed by Engr-in-Charge.
Angle valves, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm with adjustable flanges, complete all as specified and as directed by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, complete all as specified and as directed by Engr-in-Charge
Vitreous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 incl PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware complete, all as specified and as directed by Engr-in-Charge.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, complete all as specified and as direceted by Engr-in-Charge.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs complete all as specified and as direceted by Engr-in-Charge.
Soap dish fancy type chromium plated fixed with brass screws and wooden/plastic cleats complete all as specified and as direceted by Engr-in-Charge.
100mm cast iron sanitary connections - short connections pipe of length upto 300 mm, for 100mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints, fixed to wall, of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, all as specified and as directed by Engr-in-Charge.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 75mm bore pipe, all as specified and as directed by Engr-in-Charge.
Cast iron vent cowl for 75mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed by Engr-in-Charge.
Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof 75 mm bore of pipe complete all as specified and as directed by Engr-in-Charge.
Vitreous china urinal, bowl type (back or corner wall type) white incl CP Spray Nozzale including PVC waste pipe , providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement , flush pipe, grating and union for discharge pipe. fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Vitreous china urinal partition white of size 310x700 mm about 40 cm above floor line., complete all as specified and as directed by Engr-in-Charge.
Supply and fixing stainless steel wall mounted cloth hanger with 6 peg set, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material exc. 250m and depositing where directed at a level n exc. 500 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in surface channel and drain including all necessary form work, complete all as specified and as directed by Engr-in-Charge.
150mm bore salt-glazed stoneware drain pipes of grade 'A' laid in trenches and jointed as specified, complete, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified and as directed by Engr-in-Charge.
Pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab, chullah hoods and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, roof padding, kerbs not provided for including weathering, slightly rounded or chamfered angles including necessary formwork complete all as directed and specified.
TMT mild steel bars, 6-8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified & directed by Engr-in-Charge. Note: Modular metal flush boxes & cover plates deemed to be included inquoted rate.
Description all as per item No 110 above but one 3/5 pin 6 Amp socket outlet on independent board .
Description all as per item No 110 above but one 3/5 pin 6 Amp socket outlet on the same board with other switch.
All as per description of Serial item No 110 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,6 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Switch piano , single pole,1 module, one way ,16 Amp (modular type) , complete all as specified and as directed by Engr-in-Charge.
Modular Socket outlet, 2 module, 3 pin, 6 Amp flush type , complete all as specified and as directed by Engr-in-Charge.
Modular Socket combined, 2 module, 2 in 1, 6/16 Amp flush type , complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCCBs to be used TPN 4 way vertical type 415V with 400 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
MCCB 4 pole, 415 volts, 100 Amps with breaking capacity 16KA complete, therminal adjustable type, fixed in repairs, complete all as specified and directed by Engr-in-Charge.
MCB SPN, 32 to 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 10 to 40 Amps,240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
M&L for sub main wiring with copper conductor cable (2 runs of cable) multistranded 1.5 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC rigid concealed conduit not less than 25 mm dia and 2 mm wall thickness ISI marked medium grade , with all conduit accessories for power pint snad single phase ACs such that GI shadle, GI screw, rowl plug etc. including cutting chasing and 1X1.5 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire, fixed in repair, connected to common earth and earth duly complete all as specified and directed by Engr-in-Charge. Note:- 3 runs of 1.5 Sqmm (3x1.5sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 129 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Taking down ceiling fan/ exhaust fan and cable etc. and refixing/hanging the same after repair/replacement of damaged/worn out parts like canopy 02 Nos, down rod, clamps with nuts, bolts and washers, rubber bush, greasing, oiling and provn of cable from ceiling rose to fan, etc. including painting with two coats of synthetic enamel white paint and writting Ser No/Mes No with black paint complete, all as specified and as directed by Engr-in-Charge. Note:- (i) The spares like condensor, ball bearing , cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/ damage deemed to be replaced and make the ceiling fans functional. No extra pavements will be done on this account.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
LED wall mounted mirror lighting fixture 10 Watt LED, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting , fixed in repair , complete all as per the directions of Engr-in-Charge.
LED decorative down light fitting/ recess mounted panel (2' x 2') surface mounted lighting fixture 36 Watt LED, with diffuser, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting, fixed in repair, complete all as per the directions of Engr-in-Charge.
S&F in replacement of decorative wall mounting 1x15 Watt nickle finish fixture with forsted glass along with 15 watt warm white bulb GLS lamp luminaire, complete all as specified and directed by Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 32mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, fixed in repair, complete all as per the direction of Engg-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles , fixed in repair, complete all as specified and as directed by Engr-in-Charge.
M/s LAL DAYAL CONSTRUCTION CO
PARDEEP SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .