Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.8 L+₹2.6 L (19.8%)Rejected-Finance 207 B KRISHANA DPATH AJMER ROAD JAIPUR | JAIPUR | RAJASTHAN | 302001 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹19.9 L+₹6.7 L (50.5%)Rejected-Finance VILLAGE SATOJ TEHSIL SUNAM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹22.0 L+₹8.8 L (66.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Aug 2019, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Military Station Bikaner
Repair to External water pipeline and DG Set at MFFR under GE (N) Bikaner
2019_MES_269892_1
GE (N) BKN/Token-33/19-20
Open Tender
Miscellaneous Works
Item Rate
330 days
under AGE MFFR
Class E category a (ii)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹40,000
Yes
13 Sept 2021
25 Jul 2019
23 Aug 2019
25 Jul 2019
22 Aug 2019
9 Aug 2019
Amount
Excavation in trenches in soft/loose soil not exc 1.5mtr wide and not exc 1.5mtr in depth for taking out old pipe and laying new pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and as directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Supplying, laying, jointing and testing ductile iron pipe spigot & socketed size 150mm dia, class K-9 suitable for rubber tyton joints duly ISI marked complete all as specified and directed by Engr-in-Charge. Note:- Excavation and earth work and joints shall be measured and paid separately.
Dismantling and taking out exisitng rusted/corroded DI pipe of size 150mm bore spigot and socketed ends of any length & type including burning of lead/rubber joints and bailing out water if necessary all as directed.
Rrubber tyton push on gasket joints in spigot and socketed DI pipes and fittings of 150 mm dia bore complete all as specified and directed.
Supply and fixing in replacement of existing pipe any type and size in any condition at various location including GI pipe medium grade 150 mm bore (ISI marked) laid in trenches/ road crossings/along walls/ path /drain/floors with and including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement to connect existing branch pipe of any type and size including all necessary fittings required at site and testing complete all as specified and as directed by the Engineer-in-Charge. (Note:- Earth work shall be measured and paid for separately.)
All as per item No 7above but size 100 mm dia.
All as per item No 7 above but size 80 mm dia.
All as per item No 7above but size 50 mm dia.
All as per item No 7 above but size 25 mm dia.
All as per item No 7 above but size 20mm dia.
Supplying, laying, jointing UPVC bore of pipe 160mm class-3 suitable for working pressure 6kg/Square centimeter confirming to IS-4985-2000 duly ISI marked complete with all fitting such as sockets, elbows, tees and PVC flanged sockets including testing and commessioning complete all as specified and directed (Excavation & earth work shall be measured seperately) Make: - Kissan/Prakash/ M/s Reliance industries.
All as per item ser No. 13 but bore of pipe 110mm
All as per item ser No 13 but bore of pipe 90mm
All as per item ser No. 13 but bore of pipe 75/80mm
Supply and Fixing of Bulk Water Meter size 150 mm dia in existing GI/PVC/DI pipe including all necessary arrangement i.e. cutting,drilling,threading etc in pipe required at site & testing including taking out old unserviceable meter any type any size and in any condition complete all as specified & directed by the Engineer-in-Charge.
All as per item No 17 above but size 100mm dia.
S&F in replacement of pressure guage of 0 to 10.0 Kg/sqcm with all accessories including all necessary arrangement i.e. cutting,drilling,threading etc in existing pipe required at site & testing complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing in replacement of Air Release Valve (ARV) size 50 mm Dia with two air outlet for fixing up in DI/GI/HDPE water supply pipe line including all necessary arrangement i.e. cutting,drilling,threading of 2.5 mtr long GI pipe 50 mm bore ISI mark medium grade as required at site & testing complete all as specified & directed.
Taking up or down the existing rusted/damage GI / UPVCpipe of 150/160 mm dia including all fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
Taking out u/s rusted / corroded GI / PVC pipe of size 100/110 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under road etc complete all as specified and directed.
Taking up or down the existing rusted/damage GI/PVC pipe of75/80 /90 MMmm dia including all fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
Taking out u/s rusted corroded GI pipe of size 50 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under road etc complete all as specified and directed.
Taking up or down the existing rusted/damage GI pipe of25 mm dia including all fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
Taking out u/s rusted corroded GI pipe of size 20 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under road etc complete all as specified and directed.
CI special fitting in replacement of existing pipe line any type and size and in any condition CI spigot and socket end pipe like bends (any type radius and angle bend incresing,decreasing or double socket,double flansed,tee pieces single branch Y,T junction any size,double branch,cross,coller,Tapers,Tail pieces,caps,and plugs etc. sutaible for 50 to 150mm bore of pipe complete all as specified.
Repairing the leakage of CI/DI pipe line 150 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run lead joint all as directed by Eng-in-Charge.
Repairing the leakage of CI/DI pipe line 100 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run lead joint all as directed by Eng-in-Charge.
Repairing the leakage of CI/DI pipe line 80 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run lead joint all as directed by Eng-in-Charge.
Repairing the leakage of GI/ pvc pipe line 50 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s fittings from the joint/ leakage point and making new joint/repair with neccessary GI/PVC fiitins and testing or all as directed by Eng-in-Charge.
Ditto all as per serial item No. 31 here in before but suitable for 40mm bore.
Ditto all as per serial item No. 31 here in before but suitable for 25mm bore.
Supply and fixing in replacement of cast iron sluice valve 80 mm, heavy duty class PN 1:6 ISI marked (IS-14846-2000), long body, both ends flanged, complete with high tensile stainless steel spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3mm thick rubber gasket joints, suitable for 80 mm bore GI/PVC pipe any type any size and also including testing and commissioning complete all as specified and as directed. Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 34 here in before but suitable for 100mm bore.Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 34 here in before but suitable for 150mm bore.Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 34 here in before but suitable for 200mm bore.Make - Leader/Sant/Kirlosker
Supply and fixing in replacement of existing flexible hose pipe of 80 mm dia suiatable for lorry filling point all as specified & directed by the Engineer-in-Charge.
Supply and Fixing in replacement of Reflex Valve/NRV/Dual plate check valve, PN 1.6 rating of size 80 mm dia with all necessary accessories and testing complete all as specified & directed. Make - Leader/Sant/Kirlosker
Supply and Fixing in repair foot valve of any type & in any condition CI Foot Valve size 80 mm dia conforming to IS suitable for 80mm bore pipe any type i.e thread/flanged type complete all as required at site. Make - Leader/Sant/Kirlosker
Supply and Fixing in replacement of Reflex Valve/NRV/Dual plate check valve, PN 1.6 rating of size 100 mm dia with all necessary accessories and testing complete all as specified & directed. Make - Leader/Sant/Kirlosker
Supply & fixing in replacement of Gun metal gate valve with iron wheel head screwed both ends with iron pipe & fixed ISI marked of size 50mm dia bore including taking out old unserviceable valve any type any size and in any condition complete all as specified & directed.
All as per item No. 42 but of size 25mm dia bore.
All as per item No. 42 but of size 20mm dia bore.
S&F in replacement of cast iron ditechable joints suitable for 150mm dia DI/GI pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and as directed.(Note:- Excavation and Earthwork shall be measured and paid for separately)
All as per item No 45 above but size 100mm suitable for 100mm dia GI/DI pipe line
All as per item No 45 above but size 75/80mm suitable for 75/80mm dia GI/DI pipe line
S&F in replacement of PVC ditechable joints suitable for 160mm dia HDPE/PVC pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and as directed.(Note:- Excavation shall be measured and paid for separately)
All as per item No 48 above but size 100mm suitable for 100mm dia HDPE/PVC pipe line
All as per item No 48 above but size 75/80mm suitable for 75/80mm dia HDPE/PVC pipe line
All as per item No 48 above but size 75/80mm suitable for 40/50mm dia HDPE/PVC pipe line
Dismantling and opening the gland tap and head of unserviceable sluice valve of size 200mm bore and taking out the unserviceable and refixing new spindle with nut and grinding the material cutting the threads by lathe machine and fabrication of new locknut with cutting the threads inside the locknut according the spindle threads and refixing in the same position complete all as specified and directed by Engineer-in- charge.
Ditto all as per item No. 52 but size150mm bore
Ditto all as per item No. 52 but size100mm bore
Ditto all as per item No. 52 but size 80mm bore
Suuply and Fixing in replacement of automatic starter Oil Immersed type suitable for 40HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic starter Oil Immersed type any size suitable for 20HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic starter Oil Immersed type any size suitable for 15 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic starterOil Immersed any size suitable for 10 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic starter Oil Immersed type any size suitable for 7.5 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic DOL starter Oil Immersed type any size suitable for upto 5 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic DOL starter Oil Immersed type any size suitable for upto 3 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
S&F in replacement of four pole offload changeover switch 200 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
S&F in replacement of four pole offload changeover switch 100 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
S&F in replacement of four pole offload changeover switch 63mps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
Dismantling of existing defective induction motor of the following size and make from the foundation, disconnecting the electric connecting coupling pulley and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on induction motor complete all as specified and as directed by Engineer-in-Charge. 40 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item No 66 above but 20 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item No 66 above but 15 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item No 66 above but 10/12.5 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item No 66 above but 7.5 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item No 66 above but 5 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item No 66 above but 3 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening & transport to workshop & re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 20 HP Make :- any make and replacement of worn out spare parts as mentioned under resective item No-73 here in after.
Supply only the following spare parts for cetrifugal pump of 20 HP capacity make :- kirlosker/CG /Kalsi Inter stage ring
Gland cap CI with Nut bolt
Wear ring
Shaft sleeve bronze
Shaft sleeve nut bronze
Set of gasket
Dismantling opening and reassembling after repair/replacement of U/S spare parts of mono block pumping set capacity 15/12.5/10 HP spare parts required shall be measured and paid for under respective item Sr No-38 of this schedule. Job includes disconnecting from base foundation frame disconnecting electrically, reconnection, re-fixing in position transportation to work shop & back make of pump : any make, any size
Supply only the following spare parts for mono block pump of 15/12.5./10 HP capacity make :- Kriloskar Gland bush,shaft sleeve,bronze nuts & impeller etc
Gasket
Supply and fixed in replacement following items suitable for 40 HP motor pumping set Ball bearing as per existing for motor (SKF/NBC)
Ball bearing as per existing for Pump (SKF/NBC)
CI Impeller with locking screw & Nut
Supply and fixed in replacement following items suitable for 20 HP motor pumping set CI Impeller with locking screw & Nut
Ball bearing for motor (SKF/NBC)
Ball bearing as per existing for Pump (SKF/NBC)
Supply and fixed in replacement following items suitable for 15/12.5/10 HP motor pumping set Ball bearing as per existing for Motor 10/12.5 HP (SKF/NBC)
Ball bearing as per existing for Pump 3/5 HP (SKF/NBC)
Supply & Fix in replacement of the following parts of mono-block capacity 7.5 to 10HP, Make-Kirloskar, Discharge 540 LPM at head 2980 RPM CI Impeller with locking screw & Nut
Ball bearing as per existing for pump/motor
Spacer as per existing
Set of Mechanical real as per existing
Supply & fix in replacement of the following parts of mono-block capacity 3/5 HP, Make-Kirloskar, Discharge 540 LRM at 16 head 2840 RPM CI Impeller with locking screw & Nut
Ball bearing as per existing for pump/motor
Spacer as per existing
Set of Mechanical real as per existing
Supply and fixing in replacement of motor/pump protection relay model SPGD2 for phase failure,phase sequence,overloading etc, 380 to 440VAC complete with internal wiring connection in panel including all necessory arrangement and testing Make - Minilec/L&T/Siemens
Supply and fixing MCCB 4 pole 415 volt cap 200 Amp with rupturing capacity 35 KA Cat conf to IS 13947 Part-II Make L&T/LEGRAND/BCH -
Supply and fixing MCCB 4 pole 415 volt cap 100 Amp with rupturing capacity 35 KA Cat conf to IS 13947 Part-II Make L&T/LEGRAND/BCH -
Supply and fixing MCCB 4 pole 415 volt cap 63 Amp with rupturing capacity 35 KA Cat conf to IS 13947 Part-II Make L&T/LEGRAND/BCH -
Supply and fixing in replacement of three phase terminal box suitable for three phase motor as per sample, any type any size with all necessary arrangement (i.e. cable lugs, nut bolts etc) complete all as required at site.
Supply and Fixing in replacement of Electronic contactor Mnx-18 or equilant suitable for 5 to 10 HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 5 to 10HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor Mnx-22 or equilant suitable suitable for 15HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 20HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor Mnx-25 or equilant suitable suitable for 20 HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 20 HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and fixing in replacement of star coupling of rubber for motor pumpset of capacity 03 to 40 HP complete all as specified & as directed by Engr-in-charge.
Supply and fixing in replacement of MS Housing for star coupling for motor pumpset of capacity 03 to 40 HP complete all as specified & as directed by Engr-in-charge.
S&F in replacement of foundation frame made out of MS angles/channels etc including drilling holes & welding suitable for 3 to 20 HP monoblock/centrifugal pump set with nut bolts etc as per sample including all necessary arrangements with grouting of foundation bolt in PCC making good damaged foundation complete all as required at site.
Rotational moulded polyethylene water storage tanks of capacity 10000 litres, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed by Engineer-in-Charge. (Notes : (i) The water storage tanks shall be 3 layers, HDPE tanks moulded to seem-less perfection of rotational moulding process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. (ii) The tanks shall be white coloured with three layered wall and shall be ISI marked. Also refer paras 18.60 and 18.60 A of MES Schedule Part-I. (iii) Payment for inlet, outlet and over flow pipes and ball valve shall be made separately. However cost of providing necessary GI fittings such as nipples with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30 cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per actual requirements and as directed by the Engineer-in-Charge shall be deemed to be included in the unit rate of this item.(iv) HDPE storage tanks shall be procured from the manufacturers as per Appendix “D”.)
Rotational moulded polyethylene water storage tanks of capacity 5000 litres, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed by Engineer-in-Charge. (Notes : (i) The water storage tanks shall be 3 layers, HDPE tanks moulded to seem-less perfection of rotational moulding process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. (ii) The tanks shall be white coloured with three layered wall and shall be ISI marked. Also refer paras 18.60 and 18.60 A of MES Schedule Part-I. (iii) Payment for inlet, outlet and over flow pipes and ball valve shall be made separately. However cost of providing necessary GI fittings such as nipples with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30 cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per actual requirements and as directed by the Engineer-in-Charge shall be deemed to be included in the unit rate of this item.(iv) HDPE storage tanks shall be procured from the manufacturers as per Appendix “D”.)
Material and labour for 12 Volt, 180 Amp maintanance free battery suitable for DG set including trolley stand made out of MS angle iron complete all as specified and directed by Eng-in-Charge. Make: AMCO/EXIDE/STANDARD /AMRON/SUKAM/APC
Supply and fixing of existing complete system wiring set of 25 KVA Capacity DG Set with AVAR (Auto voltage Auto regulator) Circuit complete with new internal wiring set connection in panel including all necessary arrangement & testing etc including removing of old unserviceable wiring set, circuit set etc any type any size and in any condition complete all as required at site and directed.Make- Kirlosker/CG etc
All as per item no 97 but cap 45 KVA
All as per item no 97 but cap 62.5 KVA
M/S Amar construction Co.
M/S SIDHU CONSTRUCTION COMPANY
MAHAVIR CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .