Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹42.2 L | L1 | Accepted-AOC AWARD |
| 2 | L2₹44.8 L+₹2.7 L (6.34%)Rejected-Finance 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | ₹44.8 L+₹2.7 L (6.34%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹46.3 L+₹4.1 L (9.84%)Rejected-Finance SADAR BAZAR DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | ₹46.3 L+₹4.1 L (9.84%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹46.8 L+₹4.7 L (11.1%)Rejected-Finance | ₹46.8 L+₹4.7 L (11.1%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹46.9 L+₹4.7 L (11.1%)Rejected-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹46.9 L+₹4.7 L (11.1%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹41.8 L
EMD Value
₹83,600
Closing Date
14 Dec 2022, 6:00 pmClosed
GE
GE DANAPUR CANTT PIN 801503
PROVN OF OPEN SHED FOR STATION STORES AT HQ J AND B SUB AREA CHAIN LINK FENCING AND WICKET GATE NEAR GAS AGENCY OFFICE AT OLD SUP DEPOT ASC PARKING SHED FOR LT VEH AT NO 5 PS SEC CCIB 2 X HIGH MAST SECURITY LIGHT 12.5 MTR POLE FOR J AND B SUB AREA SI
2022_MES_564738_1
GE/DNR/T-61 OF 2022-23 / 8637/E8
Open Tender
Civil Works
Item Rate
180 days
DANAPUR CANTT
AS PER NIT
8 documents required · 8 mandatory
₹500
GE DANAPUR
₹83,600
Yes
1 Mar 2023
23 Nov 2022
17 Dec 2022
23 Nov 2022
14 Dec 2022
8 Dec 2022
Amount
Excavation of post hole (or similar holes)each not exc0.50 cum in soft /loose soil ,getting out ,returing filling in and raming earth or broken ruble mixed with earth around in layers not exceeding 25 cm ,watering,and removing surpl soil to adistence n. exc50 m and making good suraface complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate), as in filling of post holes complete all as specified and directed
S&F mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections confirming to Fe 410W grade E250 complete all as specified.
S&F110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with brackets etc complete all as specified and directed.
S&F PVC (SWR) bends any radius With access door of 110 mm dia complete all as specified and directed.
M & L for 20 - 25 mm thick machine cut Kota stone slab as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including incl Screed bed or bedding layer of Cement Mortar (1:4), 15 mm thick for laying floor finishes, necessary grinding, rubbing, rounding to exposed edges and polishing in grinding finish complete all as specified and directed.
M & L for brick work with sub class `B' brick (Old size) straight or curved on plan exc 6m mean radius in cement mortar (1:6) complete all as specified & directed.
M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer and finished the surfaces even and fair without using extra cement complete all as specified & directed.
M&L for prepartion new plastered surface of wall and applying two coat of cement base paint over a coat primer complete all as specified & directed.
M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
ditto but not exc. 10 cm girth or width.
M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M&L for vitrified heavy duty (dura stone) tiles 300x300x9 to 10 mm thick in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Machine Pressed precast glazed colour reflective PCC interlocking paver block 60 mm thick mixed with grey cement and pigment, laid dry and bedded on sand cushion complete all as specified and as directed. The pattern of paver block shall be approved by GE. Note: Payment of sand cushion shall be measured and paid separately.
Cutting holes into or through brick walls built in cement mortar and making good the same in cement concrete 1:2:4 type B-0 or cement mortar 1:3 as required, superficial area of cutting not exc. 150 Sqcm complete all as specified and directed
M&L for PCC 1:2:4 type B-0 (Using 12.50 mm graded stone aggregate) in roof padding/kerbs finished even & fair etc complete all as spd and directed,
S & F for steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 complete all as specified and directed.
S&F for Mild Steel angle Iron as in fencing posts and struts in fencing including cutting tops to shape as directed, driling holes, notching for wire, etc conforming to Fe 410-O or Fe 310-O complete all as specified and directed.
S&F for mild steel work conforming to Fe 310-O as in FI fillets for securing chain link fencing, angle iron horns, posts, etc cut to length bent to shapoe with necessary cuts, drilling holes etc all as specified.
Supply and fixing for chain link fencing of MS GI wire mesh, 3 mm dia of GI wire mesh upto into mattresses or cages lapped wired incl staple etc complete all as speified and directed. Note : Weight of chain link fencing shall not be more than 4 kg/sqm.
Supply & fiding for mild steel round bar 10mm dia conforming to Fe 290 Gde E-165 as line wire for chain link fencing. Note : Cutting to length, bent to shape required including binding with MS wire is included in item No 22
S&F mild steel, screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut, exc 5 cm but not exceeding 10cm long and dia of shank 05 to 10mm all as specified and directed.
M & L for plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, wather troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necesssary form work as required complete all as specified and directed.
M&L for hard core of broken bricks gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick watered and well rammed to a true surface complete as specified and directed.
S&F for galvanised concerntina coil 610mm dia, 30mm wide strips, & 2.5mm dia core wire complete all as specified and directed.
S&F for mild steel framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc complete drilled for fiding of steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings for (other covering, running rails and guides) and hanging also fasterning and fixing complete incl pintel hinges, stops hand made sliding bolts etc conforming to Fe (Gde-E-250) quality-A, including taking down old steel gates.
M&L for Pre painted galvalume sheet aluminium zinc coating GI based corrugated steel sheet with curved type 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /ridge/cladding to wall fixed with self tapping screws as specified. complete all as specified and directed.
M&L for Pre painted galvalume sheet aluminium zinc coating GI based plain sheet with curved type 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /ridge/cladding to wall fixed with self tapping screws as specified. complete all as specified and directed.
M & L for chequered cement concrete tiles of size 20cm X 200cm X 25 mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
Supply, installation and testing of electric water heater storage vertical type, BEE 4/5 star rated, 25 tr capacity 240 volts 50 Hz comprising of high wattage heating element for instant heating. extra Mild steel with Glass lined coated inner tank, rust & shock proof ABS outer body, non-ferrous pressure plate with & including provn of 04 Nos grouting bolts & nuts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable/ flexible chord and one no 15 amps 3 pin plug top complete all as specified and as directed. Make Havells/Bajaj CG/Racold
M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade 2 core having multi stranded copper conductor of size 25 Samm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in surface conduit wiring system and making good disturbed surface of wall & 25 sqm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including galvanised mild steel 1.6 mm thick box & 3 mm thick plastic laminated sheet top cover for mounting switches, sockets of 15 Amps Maks of cable Polycab/Havells/Finciex and Make of PVC conduit Plaza Harsh/Kalinga Premium/AKG
Supply and fixing for switch piano flush button single pole one way 15 amps, 230 Volts complete all as specified and as directed
Supply and fixing for socket outlet flush type multipurpose 2 in 1,3 pin 5 and 15 Amp, 230 volts complete all as specified and as directed.
Supply and fixing for CPVC SDR 13.50 pipes & plain CPVC SDR 11 with outer dia of 16 mm fitings on wall/celling or laying in floors including all connecting accessories complete all as specified and directed Make: TATA Jindal/Bansal/SFMC
Supply and fixing for PVC connection pipe hot and cold type. 15 mm dia, 450 mm long with brass adopter & washer on both sides complete all as specified and directed Make Essco/Sona/Prayag
Supply and fixing for 15 mm bore bib tap cast copper alloy, fancy type with crutch or butterfly handle screwed down for iron pipe or brass ferrule and fixed complete all as specified & directed.
Supply and fixing for 15mm bore stop valves cast copper alloy, screwed Each down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed Make Essco/Sona/Prayag
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, FRLS screened, PVC bedded, galvanised steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 25 sqmm 4.0 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid seperately under relevant items of this BoQ).
Excavation in trenches not exc 1.50 metre wide and not exc 1.50 metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
M & L clean dry river sand in trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified. Note:- Punned thickness shall be measured and paid.
M & L for old size sub class ‘B’ bricks, laid in trenches as cable covers / protection complete all as specified and directed .
Supply, installation and commissioning of 12.5 Mtrs high mast system with its accessories. Mast shaft shall be in two sections,hot dip galvanised and suitable forwind velocity as per IS 875 and including head frame, steel wire rope 6 mm dia (7/19 construction), trailing cable, double drum winch, Galvanised Lantern carriage drum at least winch arrangement suitable for 4 (four) luminaires symmetrically and lightning finial. The mast shall have an integral power tool installed inside the base compartment for its operation with siutable size electric motor, foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates. The high mast lighting system supplied with the following accessories.Make : Bajaj/Crompton Greaves/Havells/Surya
(a) LED flood light luminaires 200 Watts IP 66 type with lens incl standard fittings pressure die cast aluminium housing with heat reistant toughened front glass housing with epoxy powder coated finsh and , complete with control gear box and all accessories duly prewired.- 04 Nos. Make: Bajaj/ Crompton Greaves/Havells/Surya
(b) Low intensity twin type aviation obstruction lamp of GLS type with super bright red LED 300 Nos per lamp of IP – 65 protection aviation obstruction light complete all as directed. Make – CG , Cat No – GLS – 704 – CDL / 60 OR equivalent Make to Havells / Bajaj / Surya .
(c) Supply, installation, testing and commissioning, factory made and tested, LT feeder pillar box ,outdoor type of size as per directed by EIC and platform mounted. The panel shall be dust and vermin proof, IP65 class protection and made out of 3.15mm thick CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry and locking arrangement including internal wiring with PVC insulated, stranded copper conductor FRLS cable, IS-694 marked of adequate size but not less than 10 Sqmm. The following items accommodated with this feeder pillar including 01 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English complete all as specified and directed. The scope of work includes the following items accommodate the same panel.
(d) (i) Stag type, 4 way terminal (I/P) 63 Amps – 01 No (PCB 150 ACBC) (ii) MCCB 4 Pole, 415 volts AC grade, 40 Amps 25 KA Icu=100%Ics.(Make: Legrand/L&T/ SIEMENS) - 01 No (iii) Contactor 3 pole 32 Amps – 01 No (Legrand/L&T/SIEMENS) (iv) Toggle switch 6 Amps – 01 No (v) Timer (analogue) with battery backup – 01 No (Legrand/L&T/SIEMENS) (vi) Stage type, 4 way terminal (O/P) 63 Amps-01 No (PCB 150 ACBC) (vii) Over load relay 2/3.5A – 01 No (Legrand/L&T/SIEMENS) (viii) F. contractor 9 A – 01 No (Legrand/L&T/SIEMENS) (ix) R. contractor 9A – 01 No (Legrand/L&T/SIEMENS) (x) Motor terminal 32 Amps – 01 No (Legrand/L&T/HPL) (xi) Push switch terminal (STD) – 01 No (Legrand/L&T/SIEMENS) (xii) Push switch (F/R) (STD) – 01 No (Legrand/L&T/SIEMENS) (xiii) MCCB-3 Pole, 415 volts, AC grade, 16-40 Amps, 18 KA, ICU = 100% ICS(Make: Legrand/L&T/ SIEMENS) - 01 No
(d) Pole drawing and RCC/PCC foundation work for errection of pole shall be carried out as per manufacturers approved drawings.
(e) PCC foundation work for LT control Panel as per manufacturers approved drawings.
(f) Work to be executed by the manufacturer or their authhorized rep and MOU undertaking of the same from the manufacturer be submittedto Engineer in charge prior to excution of work .
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant incl standard fittings pressure die cast aluminium housing with heat reistant toughened front glass housing with epoxy powder coated finshed and complete accessories as per specified
Material and labour for boring hole under the road/pavment/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified & directed by Engineer-in-charge at site. Note:- The cost of HDPE pipe shall be deemed to be included in this quoted rate.
Material and labour for LT Cable rout indicator made out of PCC Post of 1:2:4 type B-1 using 20 mm graded stone aggregate of size not less than 20 cm x 15 cm and one meter height with making embossing the following letters of size 100 mm in the PCC Post " LT CABLE with ARROW" including necessary excavation and PCC 1:2:4 (30cm X 30cm x 30 CM ) for embeding in the ground complete all as specified and directed.
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
M & L for Earthing to High Mast and Panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009 GI earth strip 32 x 6 mm protected by GI pipe 40mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling PVC conduit on surface will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including galvanised MS boxes 1.6mm thick ,33mmthick plastic laminated sheet for mounting switches, sockets, fan regulators etc for one light/fan point controlled by one switch complete all as specified and as directed. Make of cable: Polycab/Havell's/Finolex and Make of PVC conduit: Plaza/Harsh/Kalinga Premium/AKG.
All as per item no 51 above but one 5 Amps socket out let point controlled by one switch on same board with other switches.
All as per item no 51 above but one 5 Amps socket out let point on independent board controlled by one switch.
All as per item no 51 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. Make of cable: Polycab/Havell's/Finolex and Make of PVC conduit: Plaza/Harsh/Kalinga Premium/AKG.
Supply and fixing switch piano flush button single pole one way 5 amps, 240 Volts complete all as specified and directed.
Supply and fixing socket outlet flush type 5 Amps, 5 pin, 240 Volts complete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and directed.
Supply and fixing socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 240 volts complete all as specified and directed.
Supply and fixing Ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
Supply and fixing for batten/angular fittings complete all as specified and directed.
Supply and fixing for electronic Fan regulator 450 watt step type complete all as specified and directed.
Supply and fixing double door SPN DBs eight way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral as per existing finishing complete all as specified and directed . Make: LEGRAND/ L&T/ SCHNEIDER/ABB
Supply and fixing with MCB SPN 5 to 40 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed . Make: LEGRAND/ L&T/ SCHNEIDER/ABB
Supply and fixing MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .Make: LEGRAND/ L&T/ SCHNEIDER/ABB
Supply and fixing LED tube light batten box type suitable single tube 1x 18/20 watt T8 lamps type complete with both end bi-pin holder with single tube rod of 18/20 watt and all accessories internally pre wired and fixed to wall/ceiling incl fittings accessories and connecting up with twin core twisted flexible copper conductor cable upto ceiling rose/connetor suitable size all as specified. Make- Havells/Bajaj/Philips/Crompton/Surya.
Supply and fixing LED bulk head 10 watt fittings environmental friendly ultra modern energy saving surface mounted decorataive bulk head fitting with electronic driver and prewired and necessary electric connection with PVC insulated twin twisted flexible copper wire of size 0.75 Sqmm complete all as specified and as directed. Make: Havells/ CG/ Bajaj/Surya.
Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, BEE 5 star rating, ISI marked complete with down rod, canopy, blades, BLDC motor etc and connecting up complete including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint complete all as specified and as directed. Make- Bajaj/Crompton Greaves/Havell's.
Supply and fixing LED light fitting for bldg security lighting energy saving & environmental friendly long life versatile pressure die-cast housing with individual high power LED as light source and lens embedded PC cover of capacity 25 watt 240 volts AC 50 Hz , IK 07 and IP 66 protection suitable for 40/25 mm dia GI pipe bracket including three years on site warranty from manufacturer complete all as specified and directed. Make: Havells Cat No: ENDURAPEARLSL25WLED757SASYTOPCMP /Bajaj, / Crompton Greaves,
M & L for security wall light bracket made out of GI pipe light grade 25 mm dia 1.2 metre length bent to shape and reduced to required size at top upto 1.5 metre length by cutting, welding and well finishing including MS clamp of flat iron of size 40x6 suitable length 2 sets complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete
M/s KUMAR ENTERPRISES
RC GUPTA AND SONS
MS JODHI PRASAD SINGH SONS
L G BUILDERS
M/S SHEO KUMAR SINGH AND SONS
LAXMI GROUP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .