| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.3 L+₹71,598.40 (2.69%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹28.1 L+₹1.5 L (5.57%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹37.4 L+₹10.8 L (40.7%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹38.5 L+₹11.9 L (44.7%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
2 Dec 2024, 6:00 pmClosed
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
REPAIR AND MAINTENANCE OF LT CABLE EARTHING FENCING AND CONNECTED WORKS AT KARAM VIHAR MAP 285 FD WKSP 261 AB TIGRISH ROAD MAP SUMARAN LINE NPG LINE MAUDE LINE SANYAT LINE PANCHWATI DAD NSB 3 20 PUNJAB 147 FD WKSP 15 GRENADIER 218 MED
2024_MES_682884_1
GE ELECT/D-63/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY DELHI CANTT
₹92,000
Yes
20 Jan 2025
7 Nov 2024
4 Dec 2024
7 Nov 2024
2 Dec 2024
21 Nov 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
Returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
Removing excavated material (i.e. soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer- in- Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engr-in-charge.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
All as per srl item No 5 here-in-before but using old bricks complete all as specified and directed by Engineer- in- Charge.
M&L for Demolition of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and as directed by Engineer-in-Charge.
M&L for providing plain cement concrete 1:2:4 type B-2 (using 40 mm grade crushed stone aggregate) complete all as specified and as directed by Engr in charge.
Supplying, laying, jointing, testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by Engineer- in- Charge, of the following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
10 Sqmm 2 core
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 80 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by Engineer- in- Charge, of the following bore sizes :-
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
Supply, fixing and testing Straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminum conductor 1100 Volts grade complete all as directed for the following sizes :-
16 -25 sqmm, 4 core
35-50 sqmm, 3.5 core
70-95 sqmm, 3.5 core
120-150 Sqmm, 3.5 core
185-240 Sqmm, 3.5 core
300-400 Sqmm, 3.5 core
M&L for disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work, suitable size of thimble LT tap, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed by Engineer- in- Charge.
S&F in replacement MCB DP, 63 Amps, 50 Hz, 10 KA, 240 Volts complete all as specified and directed by Engineer- in- Charge.
S&F in replacement MCB SP, 6 to 32 Amps, 50 Hz,10 KA, 240 Volts complete all as specified and directed by Engineer- in- Charge.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as specified and directed by Engineer- in- Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
S&F in replacement outdoor type wall mounted Busbar chamber having 04 pole busbar of rating 200 amps fitted with MCCB 100 Amp, 4 pole , 25 KA, 50 Hz as incomer including suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fastner complete all as specified and directed by Engineer- in- Charge.
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 400mm x 400mm x 300mm with 4 Nos 400 Amps aluminum bus bar and with 250 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded stone aggregate, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply and Installation in replacement of LT CT operated Trivector Meter with the following specifications:- (a) Meter Type: LT 3 Phase 4 Wire Electronic Tri vector Meter (b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5 (d) Voltage and Current rating:- (i) Reference Voltage - 3x240 V (ii) Basic Current (Ib) - 5 A (iii) Maximum continuous current (Imax) - 10 A (e) Rated Frequency (variation) - 50Hz (±5%) (f) Power consumption:- (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (h) Display in the event of Power Failure: Internal battery back-up for LCD display (j)Communication port: (i) Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is provided (ii) RS 485 for DLMS protocol (iii) Energy recording - Unidirectional
Supply, drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs complete all as specified and directed by Engineer- in- Charge.
M&L for carrying out balance distribution of load on LT Lines by checking the existing load on the feeder (3 phase,4wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load. submit feeder wise report for before load balancing and after load balancing as per format given including maintenance of LT panel i.e. tinting of all nuts, bolts, washers, cleaning of LT panel dust etc complete all as specified and directed by Engr-in-Charge.
Supply, drawing, connecting and testing of 3 core, 2.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs complete all as specified and directed by Engineer- in- Charge.
S&F in replacement of galvanized iron strip 32 X 6 mm for additional earthing lead beyond 7.5 meter complete all as specified and directed by Engineer- in- Charge.
M&L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by Engineer- in- Charge.
S&F stranded aluminium conductor cable PVC sheathed unarmoured, 1100 Volts, flat twin core of following sizes:-
M&L in replacement of Retro Reflective installation sign boards of size 12 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 9.00 meter above ground level on stainless steel heavy duty pipe of size 80mm bore embaded 75 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx75cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter will be in English language on both sides with reflective adhesive painter tapes complete all as specified and directed by Engineer- in- Charge.
M&L for re-painting of LT Steel tubular poles of any sizes by applying 2 coats of aluminum paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engineer- in- Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3174898)
Ridhi engineers and builders (BID ID -3176243)
M/s JAIMAA ASSOCIATES (BID ID -3178594)
Rajindera Enterprises (BID ID -3179157)
MV Engineers And Contractors (BID ID -3178662)
mayur enterprises (BID ID -3176961)
DS CONSTRUCTION (BID ID -3178785)
Vijay Electricals (BID ID -3176178)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .