| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC NEAR SOLAPOKHARI PO INS CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹16.8 L+₹20,468 (1.23%)Rejected-Finance 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹18.4 L+₹1.8 L (10.8%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹20.6 L+₹4.0 L (23.8%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L4 | Rejected-Finance Being L4 bidder |
Tender Value
₹18.8 L
EMD Value
₹37,640
Closing Date
12 Jun 2024, 6:00 pmClosed
Shri Himanshu IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
PROVISION OF VRF TYPE AIR CONDITIONING IN DORNIER SQUARDON 743 SQN (CG) AT CGAE (BSR) UNDER GE (I) (CG) BHUBANESWAR
2024_MES_654090_1
8475/BBSR/05/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
Bhubaneswar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) (CG) Bhubaneswar
₹37,640
Yes
24 Jul 2024
15 May 2024
18 Jun 2024
15 May 2024
12 Jun 2024
29 May 2024
Amount
M & L for point wiring (concealed) complete with FR PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic heavy grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls/floors/ceilings by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes,modular switch plates and 1.5 sqmm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed. 1.5 sqmm cable size and 2.5 sqmm earth continuity wire for one 3 pin socket outlet, 6 amps on Independent board complete all as specified and directed.
Supply & fixing modular Switch socket combination 2 in 1,5 pin 5/6 amps 3 modules complete all as specified and directed.
Supply and fixing white modular cover plate with frame including metal flush box 3 Module complete all as specified and directed. (Make : .Crabtree/Cona/Roma/ Indoasian)
M & L for sub main wiring (concealed) complete with Two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit and conduit accessories including one single run of 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface complete all as specified and directed. Note – 2 Nos of single core cable along with earth wire and PVC conduit shall be measured as one length.
S&F MCB DB made of sheet steel enclosures, powder coated double door with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified and directed.
S & F MCB SPN 32 Amps breaking capacity 10 kA, B series single phase 240 volts including making connection complete all as specified and directed.
S & F MCB SP 20 Amps breaking capacity 10 kA, B series single phase 240 volts including making connection complete all as specified and directed.
Design, Supply , Installation, testing and commissioning of air cooled variable refrigerant flow ( VRF ) modular type condensing units, each comprising of all inverter driven scroll compressors , the out door shall be full charge of green refrigerant gas (R-410a/R-407), lubricating oil and all accessories as per the specifications.The system shall have refrigerant cooled PCB , all necessary safety devices shall be provided to ensure safe operation of the system, unit should be equiped with a highly efficient oil seperation system to ensure stable operation with long refrigerant piping . The condensing units shall be suitable to work upto 53°C on cooling mode ONLY. Quoted price shall be inclusive of factory provided anti corrosion coating for aircooled condensers. The condensing units shall be suitable for smooth operation on 415 ± 10% volts, 50Hz, 3 phase AC power supply, Minimum COP should be 3.4 at 100 % load and 6.86 at 50% load condition for cooling in standard AHRI test condition, outdoor unit system should not have any duration in cooling capacity upto 39°C ambient temperature complete with mounting arrangement as per manufactuer standards and the condensing units shall be VRF Outdoor unit 22 HP capacity. Note: The cost deemed to inclusive of preparation of schematic layout of copper pipe line & cables from Outdoor unit to Indoor Unit as per site condition complete all as specified and directed. Make:- LG/DAIKIN/VOLTAS/ CARRIER
Design, Supply , Installation, testing and commissioning of Variable refrigerant flow( VRF) modular type indoor units comprising of all accessories as per the specifications. The indoor unit Hi-wall with evaporator coil,fan with motor, drain pump shall be suitable to work on cooling mode.The indoor units shall be suitable for operation on 220 ±6% /415± 10% volts, 50Hz, 3 phase AC power supply.The indoor units shall be of following capacities. VRF INDOOR UNITS : Indoor units of types mentioned below complete with cordless remote controller, mounting arrangements, drain pump etc complete all as specified and directed.Make:- LG/DAIKIN/VOLTAS/ CARRIER HIWALL SPLIT AC's VRF Indoor Units :
Wall Mounted Unit 2.0 TR
Wall Mounted Unit 2.5 TR
Supply & Fixing of Refrigerant Joints type Y or T as per manufacturer STD. material suitable for site for RF units only complete all as specified and directed.
S & F LOW SIDE Works for all Indoor Units ( 2.0 TR -04 Nos, 2.5 TR -04 Nos.) Including copper piping for supply and return line, insulation, cable tray, drain piping, communication cable of suitable size for indoor and outdoor unit and gas charging as required for sufficient cooling upto 16°C etc, complete necessary civil work i.e. making holes in wall, making good to disturbed surface to match with existing all as required as per site ( hanger bldg ( G+4 ) located inside Airport Area) requirement complete all as specified and directed.
Supply fixing, connecting and testing XLPE insulated screened PVC bedded galvanized steel strip or wire armoured heavy duty electric power cable with aluminum conductor 1100 volt grade cross sectional area 25 Sq mm 4 Core including necessary saddles to fix in wall/floor complete all as specified and directed.
S&F MCCB with fixed thermal & magnetic release of breaking capacity 30 kA, 415 Volts, 63 Amps 4 poles along with enclosure near ODU unit complete all as specified and directed.
S&F MCB, 415 Volt 63 A TPN, of breaking capacity 10KA to be fixed at existing Bldg Panel complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised iron strip 25×4mm as earthing lead by means of check nuts and washer of galvanized iron or steel including 40 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcoal dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
S&F GI strip 32 mm x 6 mm complete laid in trenches / ducts / wall fixed on with proper insulating material (in extn of earthings) complete all as specified and directed.
Shree Mahavir Associates
M/S SOMANATH ENTERPRISES
cooltech engineering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .