Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.3 LAccepted-Finance ASSOTECH BUSINESS CRESTERRA UNIT NO 301 TO 318 FLOOR 3RD TOWER 2 PLOT NO 22 SECTOR 135 NOIDA UTTAR PRADESH 201304 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201304 | 1 | Accepted-Finance L1 LOWEST BIDDER | |
| 2 | 2₹3.8 L+₹42,393.20 (12.7%)Rejected-Finance B 6 3 RAJOURI GARDEN RAJOURI GARDEN WEST DELHI DELHI 110027 UDYAM DL 11 0004310 07AAFCK3293B1ZQ B R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110027 | 2 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 3 | Rejected-Technical GURGAON | GURUGRAM | HARYANA | 122001 | - | Rejected-Technical EXPERIENCE NOT PROPER |
Tender Value
₹6.2 L
EMD Value
₹2,000
Closing Date
6 Feb 2023, 5:00 pmClosed
SE ETC AZAMGARH
220KV S/S COLONY HAFIZPUR AZAMGARH
PATROLLING AND CONDITION MONITORING (VISUAL AND THERMAL) BY DRONE FOR 132 KV T/S LINES UNDER ETD, MAU
2023_UPTCL_767534_2
70/AETC/2022-23
Open Tender
Electrical Works
Item Rate
90 days
MAU
UTR SLIP OF EMD TENDER FEE PAN CARD GST CERTIFICATE WORK EXPERIENCE etc.
2 documents required · 2 mandatory
₹590
SE ETC UPPCL AZAMGARH
₹2,000
17 Feb 2023
27 Jan 2023
7 Feb 2023
27 Jan 2023
6 Feb 2023
27 Jan 2023
27 Jan 2023 - 6 Feb 2023
Amount
Patrolling and Condition Monitoring (Visual & Thermal) of Over Head EHV Transmission Line by Drone for 132 KV Kasara (400) - Mau Old Line as per Technical Specifications & Direction of the Supervising Engineer: To conduct aerial videography of 132 KV Transmission line conductor and provide annotated Video along with report in PDF & Excel sheet. [Service: S0684]
To conduct aerial thermography of 132 KV Transmission line conductor and provide following output: a Aerial thermal video b Hotspots and temperature difference in pdf/excel if any hotspot detected c:- Annomally location in PDF & Excel sheet. [Service: S0684]
To conduct visual and thermal inspection of 132 KV Transmission Line towers (details provided in SOW) and provide following outputs: - I.) Detailed inspection report in pdf format. ii.) Tower wise Images (Visual & Thermal) with annotation of the damage or anomaly (if any) III.) Patrolling excel sheet [Service: S0684]
Patrolling and Condition Monitoring (Visual & Thermal) of Over Head EHV Transmission Line by Drone for 132 KV Kasara-Mau New DC Ckt as per Technical Specifications & Direction of the Supervising Engineer: To conduct aerial videography of 132 KV Transmission line conductor and provide annotated Video along with report in PDF & Excel sheet. [Service: S0684]
To conduct aerial thermography of 132 KV Transmission line conductor and provide following output: a Aerial thermal video b Hotspots and temperature difference in pdf/excel if any hotspot detected c:- Annomally location in PDF & Excel sheet. [Service: S0684]
To conduct visual and thermal inspection of 132 KV Transmission Line towers (details provided in SOW) and provide following outputs: - I.) Detailed inspection report in pdf format. ii.) Tower wise Images (Visual & Thermal) with annotation of the damage or anomaly (if any) III.) Patrolling excel sheet [Service: S0684]
Patrolling and Condition Monitoring (Visual & Thermal) of Over Head EHV Transmission Line by Drone for 132 KV Mau Old-Mau New Line as per Technical Specifications & Direction of the Supervising Engineer: To conduct aerial videography of 132 KV Transmission line conductor and provide annotated Video along with report in PDF & Excel sheet. [Service: S0684]
To conduct aerial thermography of 132 KV Transmission line conductor and provide following output: a Aerial thermal video b Hotspots and temperature difference in pdf/excel if any hotspot detected c:- Annomally location in PDF & Excel sheet. [Service: S0684]
To conduct visual and thermal inspection of 132 KV Transmission Line towers (details provided in SOW) and provide following outputs: - I.) Detailed inspection report in pdf format. ii.) Tower wise Images (Visual & Thermal) with annotation of the damage or anomaly (if any) III.) Patrolling excel sheet [Service: S0684]
Patrolling and Condition Monitoring (Visual & Thermal) of Over Head EHV Transmission Line by Drone for 132 KV Kasara (400 KV)-Semari Old Line as per Technical Specifications & Direction of the Supervising Engineer: To conduct aerial videography of 132 KV Transmission line conductor and provide annotated Video along with report in PDF & Excel sheet. [Service: S0684]
To conduct aerial thermography of 132 KV Transmission line conductor and provide following output: a Aerial thermal video b Hotspots and temperature difference in pdf/excel if any hotspot detected c:- Annomally location in PDF & Excel sheet. [Service: S0684]
To conduct visual and thermal inspection of 132 KV Transmission Line towers (details provided in SOW) and provide following outputs: - I.) Detailed inspection report in pdf format. ii.) Tower wise Images (Visual & Thermal) with annotation of the damage or anomaly (if any) III.) Patrolling excel sheet [Service: S0684]
Kambill Systems
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .