Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical 106 GREEN AVANUE NAGAR AJMER ROAD GAJSINGHPURA JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | Rejected-Technical Technically Non - Responsive |
Tender Value
₹3.2 Cr
EMD Value
₹3.2 L
Closing Date
30 Mar 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Project Director (Technical)
JUIDCO Bhawan, Kutchery Chowk, Ranchi - 834001
Development of Roundabout of Hinoo Chowk Softscaped and Hardscaped work
2026_UDD_111076_1
JUIDCO/NIT/Hinoo Chowk/RNC/686
Open Tender
Civil Works
Works
120 days
Ranchi
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
₹3.2 L
18 Apr 2026
10 Mar 2026
1 Apr 2026
10 Mar 2026
30 Mar 2026
10 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. | 76.2 | CUM | - | - |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B). | 19.05 | CUM | - | - |
| 3 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
25 % of Total earth Excavated For Fdn. | 19.05 | CUM | - | - |
| 4 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume). | 7.5 | CUM | - | - |
| 5 | Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I. | 254 | SQM | - | - |
| 6 | Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. | 36 | CUM | - | - |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand ) : 8 graded stone aggregate 40 mm nominal size ) | 25.4 | CUM | - | - |
| 8 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting In position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. | 2.57 | CUM | - | - |
| 9 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). | - | CUM | - | - |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete | 179 | SQM | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
cancelled_1.pdf
pdf • 1.88 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.02 MB
SBDHinoochowk.pdf
Tender Documents • 9.70 MB
BOQ_150109.xls
BOQ • 0.37 MB
TECHSPECIFICATION.pdf
Additional Documents • 4.37 MB
SampleDwg.pdf
Additional Documents • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .