Executive Engineer (E )BM-II
BM-II (E) Division, Gyan Mandir Office, Tees January Lane, New Delhi-110011
Replacement of old copper wiring , Old fittings fixtures, distribution board at laxmi bai nagar Barat Ghar and Moti bagh Barat Ghar and community Centre at Moti bagh ,New Delhi under BM-II division
2026_NDMC_299107_1
54/EE (BM-II) E/26-27
Open Tender
Electrical Works
Percentage
120 days
Laxmi Bai Nagar Barat Ghar and Moti bagh BaratGhar
As per NIT
2 documents required · 2 mandatory
₹0
₹63,112
28 Sept 2026
28 Sept 2026
7 Oct 2026
28 Sept 2026
7 Oct 2026
28 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core
cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C | 70 | Point | 2,101 | ₹1,47,070 |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor,
single core cable in surface/ recessed steel conduit as required.
(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 800 | Mtr. | 414 | ₹3,31,200 |
| 2.01 | (b)2 X 10 sq. mm + 1 X 6 sq. mm earth wire | 100 | Mtr. | 778 | ₹77,800 |
| 2.02 | (c) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire | 30 | Mtr. | 1,760 | ₹52,800 |
| 3 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed
steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 600 | Mtr. | 480 | ₹2,88,000 |
| 4 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 24 | Each | 1,806 | ₹43,344 |
| 5 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 24 | Each | 1,258 | ₹30,192 |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete
with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double Door | 5 | Each | 2,773 | ₹13,865 |
| 7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete
with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double Door | 6 | Each | 2,871 | ₹17,226 |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following
poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole | 774 | Each | 285 | ₹2,20,590 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.91 MB
BOQ_399139.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .